• Title/Summary/Keyword: Blood Stream

Search Result 111, Processing Time 0.029 seconds

The Experimental Study of the End-to-side Microarterial Anastomosis with the Longitudinal Slit and the Triangular Flap (고전적 및 삼각조각 기법을 이용한 단-측면 미세동맥 접합술의 실험적 연구)

  • Lee, Jun-Mo;Lee, Gang-Wook;Lee, Dong-Geun
    • Archives of Reconstructive Microsurgery
    • /
    • v.1 no.1
    • /
    • pp.51-55
    • /
    • 1992
  • Problems of composite tissue transfer commonly arise when a single indispensable recipient vessel receives the graft vssel, and the graft vessel must be sutured in end-to-side fashion so as not todisturb the vascularity of the recipient vessel. The triangular flap in the recipient vessel wall gives an intact endothelial surface when the flow of blood stream is presented and may reduce the chance of anastomosis. We selected mature Wistar rats weighing over 450 grams to compare the conventional longitudinal slit from the triangular flap in the recipient carotid artery over bloood pressure and blood flow when the donor carotid artery was anastomosed in end-to-side fashion. In 30 minutes after anastomosis, maximum blood pressure measured in the donor carotid arterial side when the recipient arterial wall was fasioned with the longitudinal slit was recorded 114 mmHg and with the triangular flap 100mmHg. Minimum blood pressure with the longitudinal slit was 98mmHg and with the triangular flap 88mmHg. The amount of blood collected for 30 seconds in the conventional longitudinal slit was 1.18mg and in the triangular flap 0.78mg. Histology study in 30 minutes, the conventional longitudinal slit demonstrated the more hemorrhagic features around the suture material compared to that of the triangular. flap and, in the 7th day, the conventional longitudinal slit demonstrated the more prominent granulomatous reactions and vascular proliferations around the suture material compared to that of the triangular flap.

  • PDF

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Inhibition of Cholesterolesterase by Porphyrin Complexes (포르피린 화합물을 이용한 콜레스테롤에스테르 가수분해효소 억제반응)

  • Lee, Bong Ho;Lee, Chang Yeol;Yu, Jong Wan;Yu, Byung Soo
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.3
    • /
    • pp.302-305
    • /
    • 1998
  • The high cholesterol level in the blood stream is the main cause for cardiovascular diseases. Despite considerable worldwide effort to reduce the blood cholesterol level, we still need a remarkable drug. For this reason, the inhibition of cholesterolesterase by synthetic porphyrin complexes was investigated. Some of the phenyl substituted porphyrins inhibited the enzyme and the inhibition constant was in the range of ${\mu}M$. The substituents on the phenyl group of tetraphenylporphyrin did not affect much on the inhibition constant.

  • PDF

A Literature Review about Application of an Auricular Acupuncture Therapy for Independent Oriental Medical Nursing Intervention Development (한방간호중재개발을 위한 이침요법(耳鍼療法)적용에 대한 문헌연구)

  • Moon, Hee-Ja;Kim, Kwuy-Bun;Sok, So-Hyune;Hong, Kyung-Hwa
    • Journal of East-West Nursing Research
    • /
    • v.4 no.1
    • /
    • pp.66-76
    • /
    • 1999
  • The auricular acupuncture therapy is stimulus treat method that acupuncts or moxibusts at the reaction blood vessel point of various diseases in the upper portion of ear. And this effects from the reaction blood vessel point of an ear to the meridian of whole body system through blood stream. The auricular acupuncture has cured and cared signs and symptoms of many diseases and pathologic problems. And this treatment heels abnormal reactions, nursing focuses so it was examined through literature review that nurses use many portions of the auricular acupuncture in their clinical cares of oriental medicine. This study was proved that the Mae-Chim acupuncture method among various methods of the auricular acupuncture is easy and simple so this method can be used by nurses. And the ear acupuncture site which controls diarrhea, insomnia, migraine, stress vomiting, dyspepsia, high fever, insufficient lactation, bowel dysfunction, menoxenia, anxiety, pruritus and can be found easily and is few the number of acupuncture so the oriental medicine nurses can apply easily to their clients. Therefore the independent oriental medicine nursing intervention can be developed by application of the auricular acupuncture therapy on the oriental medicine clinical nursing and home care in our community.

  • PDF

Complicated Wound Infection Following Transvenous Endocardial Pacemaker (경정맥(經靜脈) 내적(內的) Pacemaker 이식후(移植後) 발생(發生)한 복잡한 감염합병증(感染合?症)의 1치험례(治驗例))

  • Lee, D.Y.;Yoon, Y.J.;Cho, B.K.;Hong, S.N.
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.265-270
    • /
    • 1976
  • Implantation of a permanent pacemaker is a widely accepted procedure for the patient with complete heart block.As a result of these device, the prognosis for patients with Adams-Stokes syndrome caused by complete A-V block and other cardiac arrhythmia have become much more optimistic. Permanent pacemaker implantation by means of a transvenous approach has made the operative risk much less and the procedure simpler. However, a number of complications have been reported in the literature regarding transvenous endocardial pacemaker implantation during the last a decade. The patient presented in this paper is a 26-year old girl who was implanted with a permanent pacemaker at 14 years of age because of a congenital A-V block. Following first exchange of pulse generator, the electrode (lead) was fractured, so that by the pulse generator, a change to the transvenous technique of implantation was made, After this, there were episodes of recurrent wound infection on three occasions, even though the site of pulse generator implantation was exchanged to the contralateral side of chest wall, massive doses of antibiotics were administered and sensitivity tests for coagulase positive staphylococcal infection were performed. Though there was no definite evidence of blood stream infection by blood culture, we decided not to use the transvenous technique and not to implant the pulse generator in the chest wall because the venous system and the entire anterior chest wall appeared to be diseased or contaminated by virulent pyogenic organisms. Finally this intractable systemic and local wound infection was successfully controlled by myocardial lead implantation via a subxiphoid approach and implantation of the pulse generator far down in the abdominal wall. The causes and routes of recurrent wound infection and possible blood born infection in this particular patient are still obscure. We strongly believe that myocardial pacemaker implantation is much safer than transvenous endocardial pacemaker implantation & myocardial pacemaker implantation is a definite method for controlling such an intractable wound infection. following transvenous pacemaker implantation.

  • PDF

A Study on a Multichannel(128) Ultrasound Pulsed Doppler System with Serial Data Processing for Sensing the Blood Flow (혈류 진단을 위하여 직렬데이터 처리를 하는 다중(128) 채널 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Young-Kil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.3
    • /
    • pp.389-396
    • /
    • 1986
  • A pulsed ultrasonic doppler flowmeter for mesurements of velocity profils in man is described. The device projects a beam of ultrasound in burst of 570 ns duration at 3.5 MHz. The back-scattered signals are processed to produce a signal oxrresponding to the mean velocity over a small region of the flowing stream. The observation range of 112mm is divided into 128 depth channels. The size of this sample volume determines the flowmeter sensitivity and accuracy. The device uses a quadrature detector to detect the direction of the moving target(hemoglobin). The main feature of the novel instrumnet is its simple hardware structure due to sequential signal processing.

  • PDF

Effect of Radiation on mRNA Expression of Ceruloplasmin Gene (방사선 조사에 따른 U-937 세포의 Ceruloplasmin 유전자에서 mRNA 발현 변화)

  • 오연경;임희영;김종수;윤충효;김인규;윤병수
    • Toxicological Research
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 2004
  • Against environmental stress, ceruloplasmin which is a plasma protein, are believed to play central roles in antioxidant- or peroxidase-activity in blood stream to remove free radicals, which may be caused by exposing of $\gamma$-irradiation. In human U-937 cells exposed to $\gamma$-irradiation, the levels of mRNA in ceruloplasmin gene were measured on 0, 4, 12, 24 hr after exposing by using comparative RT-PCR (Reverse transcriptase-polymerase chain reaction) which was achieved to compare with house keeping genes such as $\beta$-actin and hprt. After $\gamma$-irradiation of 100 rads or 200 rads, the total quantities of RNA were increased as dose and time dependent manner. On the contrary, the variation of mRNA expression in ceruloplasmin was not found until 4 hr after irradiation. After 12 hr and 24 hr of irradiation, the levels of mRNA in ceruloplasmin were significantly increased as dose and time dependent manner than un-exposed cells.

Left ventricular-right atrial communication (One case report) (좌심실-우심방 단락 치험 1례)

  • 오세웅
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.683-687
    • /
    • 1986
  • A direct communication between the left ventricle and right atrium is a relatively uncommon defect. Familiarity with this anomaly has become increasingly important, however, since the preoperative findings may be identical with those of an atrial septal defect. The left ventricle is directly related to the right atrium over. an area of the membranous ventricular septum which extends superior to the septal attachment of the right atrioventricular valve in the LV-RA communication. The clinical triad of a ventricular septal defect murmur, cardiac enlargement, and an arteriovenous shunt at atrial level is characteristic of the malformation. A 2-year-old boy with left ventriculo-right atrial communication has operated at the Maryknoll Hospital. Under the cardiopulmonary bypass, the atrium was opened, there was a jet-blood stream just above the atria-ventricular portion adjacent to the septal leaflet of the tricuspid valve.

  • PDF

Anti-inflammatory and Anti-bacterial Effects of Aloe vera MAP against Multidrug-resistant Bacteria

  • Choi, Sang Hwa;Shin, Hea Soon
    • Natural Product Sciences
    • /
    • v.23 no.4
    • /
    • pp.286-290
    • /
    • 2017
  • Multidrug-resistant Acinetobacter baumannii and Pseudomonas aeruginosa are highly dangerous nosocomial pathogens, cause the symptoms of skin infections, pressure sores, sepsis, blood stream and wound infections. Unfortunately, these pathogens are immune to the most common antibiotics, such as, carbapenem, aminoglycoside and fluoroquinolone. Therefore, it is imperative that new and effective antibiotics be developed. In the present study, the antimicrobial effects of Aloe vera MAP (modified Aloe polysaccharide) on Staphylococcus aureus and Bacillus subtilis, Escherichia coli and Enterobacter aerogenes, and clinical Pseudomonas aeruginosa and clinical Acinetobacter baumannii were comprehensibly investigated. Prior to the growth inhibition effect measurement and antibiotic disc diffusion assay on gram-positive and gram-negative bacteria and selected multidrug-resistant Pseudomonas aeruginosa and Acinetobacter baumannii, antimicrobial resistance screening was performed for the multidrug-resistant bacteria obtained from clinical isolates. The results for showed the Aloe vera MAP had a concentration-dependent effect on all of examined bacteria, particularly on Pseudomonas aeruginosa. Anti-inflammatory and anti-oxidant experiments were also performed dose dependently effects to confirm the beneficial physiological effects of Aloe vera MAP.