• 제목/요약/키워드: Blood Pump

검색결과 215건 처리시간 0.027초

Wireless Magnetic Pump: Characteristics of Magnetic Impellers and Medical Application

  • Song, Moon Kyou;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.344-351
    • /
    • 2017
  • Wireless magnet pumps are used in medical applications and are particularly useful as artificial heart ventricular assist devices (VADs). To investigate wireless operation of magnetic pumps, we fabricated three types of magnetic impellers using bonded magnets by blending magnetic powders of SmFeN, NdFeB, and Sr-ferrite. We investigated the magnetic properties of the fabricated magnetic impellers, which are driven by the application of magnetic coupling with an external driving magnet or external coil system, without a driving motor, shaft, or mechanical bearings. The use of wireless magnetic pumps is therefore not complicated by critical issues of size, heat, and vibration, which are very important issues for blood pumps. The magnetic properties of the impellers, such as their rotational speed, driving torque and hydrodynamic performance, determine their wireless driving ranges. We conducted performance evaluations of the impeller's magnetic wireless manipulation, heat, and vibration. In addition, we carried out an animal test to confirm the suitability of the wireless magnetic pumps for use as biventricular assist devices (BiVADs).

원심 혈액 펌프에서의 혈액의 흐름 평가 (Estimation of Blood Flow in a Double Output Centrifugal Blood Pump)

  • 신동춘;앤디 탄;최병근;김원철
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.153-158
    • /
    • 2006
  • 최근 임상용 LVAD의 계속된 발전으로 인해 환자들의 삶이 연장되었다. 그러나 LVAD가 환자의 삶을 연장하였지만, 우심실 심부전증을 야기 시켰고, 결론적으로 환자들은 RVAD가 필요하게 되었다. 이러한 이유로 장시간 사용할 수 있는 BVAD의 도입이 요구 되어졌다. 최근 BVAD에 관련된 연구들을 보면 장시간 사용을 위한 원심 BVAD의 디자인과 BVAD에서의 누수 정도를 파악하는데 목적을 두고 있다. 따라서 본 논문에서는 BVAD의 누수를 파악하기 위한 속도 데이터와 용적당 흐름 비율의 계산을 CFD를 사용하여 해석적으로 조사하고자 하였다. CFD의 해석 결과 틈새부위의 회전수가 증가 할수록 혈액의 흐름을 방해하는 역류가 증가하고 유량도 줄어들어, 틈새부위의 누수량이 회전속도의 변화에 의존된다는 것을 확인 할 수 있었다.

  • PDF

Experimental Flow Visualisation of an Artificial Heart Pump

  • Tan, A.C.C.;Timms, D.L.;Pearcy, M.J.;McNeil, K.;Galbraith, A.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.210-216
    • /
    • 2004
  • Flow visualization techniques were employed to qualitatively visualize the flow patterns through a 400% scaled up centrifugal blood pump. The apparatus comprised of a scaled up centrifugal pump. high speed video camera. Argon Ion Laser Light Sheet and custom coded particle tracking software. Reynolds similarity laws are applied in order to reduce the rotational speed of the pump. The outlet (cutwater) region was identified as a site of high turbulence and thus a likely source of haemolysis. The region underneath the impeller was identified as a region of lower flow.

소아용 좌심실 보조장치(VICT)의 개발 및 in-vivo 실험 (Development of Pediatric VAD(VICT) and its in-vivo Test)

  • 이상훈;박이태;김삼현;이관우;이계한;안혁
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.207-212
    • /
    • 1996
  • We developed pneumatic blood pump and its driving system as a pediatric ventricular assist device. The blood pump is diaphragm type system and its blood contacting area is coated with Bio-Span. The driving unit Is consists of dual pumps, valves for the reliable blood pumping and its controller uses 80C196(Intel) as a main processor. The acute animal experiment was performed with dogs and its body weight is about 20 kg. The maximum cardiac output is about 2.1 l/min and the pressure and flow curves showed reliable operation as assist device.

  • PDF

수치해석을 통한 ECMO용 원심형 혈액 펌프 설계 (DESIGN OF A CENTRIFUGAL BLOOD PUMP FOR ECMO DEVICE THROUGH NUMERICAL ANALYSES)

  • 최신화;허남건;;강성원;김원정;강신형
    • 한국전산유체공학회지
    • /
    • 제21권1호
    • /
    • pp.103-109
    • /
    • 2016
  • With the rapid increase in the number of patients with cardiopulmonary diseases, more cardiopulmonary circulatory assist devices are also needed. These devices can be employed when heart and/or lung function poorly. Due to the critical role they take, these devices have to be designed optimally from both mechanical and biomechanical aspects. This paper presents the CFD results of a baseline model of a centrifugal blood pump for the ECMO condition. The details of flow characteristics of the baseline model together with the performance curves and the modified index of hemolysis(MIH) are investigated. Then, the geometry of baseline impeller and the volute are modified in order to improve the biomechanical performance and reduce the MIH value. The numerical simulations of two cases represent that when impeller radius and prime volume decrease the MIH value also decreases. In addition, the modified geometry shows more uniform pressure distribution inside the volute. The findings provide valuable information for further modification and improvement of centrifugal blood pumps from both mechanical and biomechanical aspects.

인공심장용 무축(無軸) 원판형 자기 부상 모터 (Shaftless Disk - type Self-bearing Motor for Artificial Heart)

  • 김승종
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.559-564
    • /
    • 2001
  • In order to apply into a compact and reliable centrifugal blood pump, this paper introduces a self-bearing motor in which a rotor is rotated without contact. The rotor is actively controlled in only radial directions, while the axial and tilting motions are passively stable owing to the disk-shape structure of the rotor. A prototype was made in outer-rotor type that is far better in the compactness than inner-rotor type. The prototype could be driven up to 8000 rpm with the rotor vibration under 0.12mm. The maximum cardiac output and pressure head were 9 L/min and over 200 mmHg, respectively. These experimental results show that the proposed self-bearing motor has sufficient performance for application to a real blood pump.

  • PDF

냉혈 K 심정지액의 임상적 이용 (Clinical use of cold blood potassium cardioplegia)

  • 오봉석;김상형;이동준
    • Journal of Chest Surgery
    • /
    • 제15권1호
    • /
    • pp.35-39
    • /
    • 1982
  • Cold blood potassium cardioplegia, by two types of the infusion systems, was used in 45 patients who were undergone the open cardiac operation. Method A [in 25 patients] was the syringe infusion system and method B [in 20 patients] was the pump infusion system. Cold blood potassium cardioplegic solution was used less amount on method B than method A. Serum potassium was often increased significantly on method A as a result of excessive infusion of cold blood potassium cardioplegic solution. But method B, excessive infusion of cold blood potassium cardioplegic solution was prevented by reperfusion of the previous infused cold blood potassium cardioplegic solution through the recirculation system. Alteration of infused rate and concentration of potassium in cold blood potassium cardioplegic solution during infusion [which might be suggested on the method A] could be controlled on method B.

  • PDF

심장내 이식형 축류 혈액펌프 용혈특성에 관한 연구 (A Study on Hemolysis Characteristics of Intra-Cardiac Axial Flow Blood Pump)

  • 김동욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.353-362
    • /
    • 2000
  • 축류형 혈액펌프에서 발생하는 용혈이 이 펌프의 성공여부를 결정짓는 주요한 요인의 하나이다. 지금까지는 용혈을 알아내기 위해서는 in-vitro 적인 실험에 의하여 용혈량을 추정하였으나, 수치유체해석에 의한 용혈량의 추정이 가능하다고 생각된다. 따라서, 본 연구에서는 다양한 형태의 임펠러에 대하여, 난류모델은 k-$\varepsilon$모델을 사용하여 3차원 수치유체역학 해석을 시도하였다. 수치유체해석에 있어서는 펌프 유입측에 입자를 흘려 넣어 이 입자가 매일 10ms마다 받는 난류에너지를 구하여 전단응력으로 환산하였다. 해석결과 전단응력은 주로 임펠러의 후방에서 나타나는 것을 알 수 있었다. 수치유체해석결과의 신뢰성을 확인하기 위하여 임펠러의 in-vitro 실험에 의한 용혈시험 결과를 비교하였으나, 양자 사이에 상관도는 높은 것을 알 수 있었다. 상기한바와 같이 유체 해석에 의한 용혈 예측은 물론 용혈이 발생하는 주요 부위의 예측이 가능함을 시사하고 있어, 축류형 혈액펌프 개발시 용혈 특성 개선을 위한 설계도구로써의 유용함을 확인하였다.

  • PDF

공압식 심실보조장치의 개발 및 평가 (Development and Evaluation of Pneumatic Ventricular Assist Device)

  • 이상훈;박이태;김삼현;한동선;이학중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.247-250
    • /
    • 1995
  • The purpose of this paper is to develop diaphragm-type pneumatic ventricular assist device(VAD) for clinical application and to evaluate its performance through the mock circulation system. The blood housing and diaphragm are made by coating pellethane on the metallic mold and the back plate is made by machining process. The relations of cardiac output(CO) vs. beat rate and CO vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. As a result, the volume of blood pump is 70 ml, maximum CO is 5 L/min and CO has a close relation to the input resistance of blood pump. The hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

술 전 항혈소판제 복합투여가 무심폐기하 관상동맥우회술 후 출혈에 미치는 영향 (Effects of Combined Antiplatelets on Bleeding in Off-Pump Coronary-Artery Bypass Surgery)

  • 이수경;김태진;송윤석;정선호;양경호;최강주;김용복
    • Journal of Yeungnam Medical Science
    • /
    • 제28권2호
    • /
    • pp.124-132
    • /
    • 2011
  • Background: Antiplatelet agent administration is critical in managing coronary-artery disease, but there is a concern regarding operation-related bleeding and an increase in blood transfusion in such, especially when delivering combined antiplatelet agents. This study was conducted to evaluate the effect of the administration of antiplatelet agents on off-pump coronary-artery bypass surgery (OPCAB). Methods: From March 2003 to December 2009, 49 patients who had undergone OPCAB were collected retrospectively. The patients were divided into three groups according to the administration of antiplatelet agents before the OPCAB operation: 21 patients were given an aspirin agent (group 1), 19 patients were given combined agents (aspirin+clopidogrel) (group 2), and nine patients were not given any antiplatelet agent (group 3). The three groups' perioperative hematologic and coagulation profiles, including their platelet counts, hemoglobin levels, hematocrit, prothrombin times, and aPTTs (activated partial thromboplastin times), and their postoperative bleeding, related complications, transfusion requirements, and operation times, were compared. Results: The operation time in group 2 was 4.3 hours, longer than those in the two other groups, and urgent operation was significantly most frequent in group 2 (63%). The amount of blood loss and the number of patients who received blood transfusion were not different in the three groups. The perioperative hemoglobin level, hematocrit, platelet count, prothrombin time, and aPTT were also not significantly different among the three groups. Conclusion: The continuous administration of antiplatelet agents to the patients in this study did not increase their postoperative bleeding or operation-related complications. Therefore, OPCAB may well be considered even if combined antiplatelet agents are being administered.

  • PDF