• 제목/요약/키워드: Blood Pressure Point

검색결과 148건 처리시간 0.023초

소규모 사업장 보건관리대행기관의 간호업무 운영관리 지원체계 (Management and Supporting System on the Occupational Health Nursing Services Provided in Group Occupational Health Agencies of Korea)

  • 유경혜
    • 한국직업건강간호학회지
    • /
    • 제8권2호
    • /
    • pp.193-211
    • /
    • 1999
  • This study was carried out to investigate the management and support system affecting to the occupational health nursing services(OHNS) provided in group occupational health agencies(GOHA). Questionnaire was developed and distributed to 82 nurses who were working in GOHA and who agreed to participate in the survey. The results were as follow: 1. OH nurses responded were mostly in the age of twenty to thirties(89%), married(73.7%), technical college graduates(88.9%), worked in hospital(85.4%) and participated more than 1 year in group occupational health services (96.3%). 2. Fifty eight point four percent of the OH nurses worked in number of workplace more than 30 to less than 60 in the OHNS form. The figure of workplaces undertaken by nurses was ranged greatly from 9 to more than 100. Number of employees who cared by nurses were mostly under 5,000 peoples in 93.3%. The types of industry was mostly manufacturing and located in the order of factory complex area, suburban, urban and others. 3. Most OH nurses(87.8%) were fully involved in the OHNS for the SSE. Their working days to visit SSE was 5 days per week(77.8%) and one day in the GOHA at 41.3%. 4. The OH documents using by nurses were found in more than 23 different types. However, they were largely summarized in the types of 'Workplace Health Management Card', 'Personal Health Counselling Card', 'Daily Health Management Report', 'Visiting List of Workplace' and 'Sick Employee List'. 5. The items of laboratory test provided by GOHA were mostly achieved in the purpose of basic health examination. They were used to be the blood pressure check(98.8%), blood sugar test (98.8%), urine sugar and protein(91.4%), SGOT and SGPT(85.3% each), cholesterol (82.9%), hepa vaccine immunization(82.9%), r-GPT(81.7%), hemoglobin(79.3%) and triglyceride(75.5%). 6. The OH nurses(92.7%) followed the work pattern to visit the GOHA before and after small-scale enterprises(SSE) visit by car driven by nurses in 74.3%. They were payed by GOHA for transportation fees in certain amounts. However, nurse is the main person(75.0%) who covers up in case of traffic accident. If the GOHA has no transportation regulation for the formal workplace visit, data showed that nurses had been responsible to take charge(31.7%). 7. The personnel manager who takes in charge for nursing services was 'nurse' in 61.7% and 41.2% worked as the final decision maker related to nursing work. The OH nurses' opinions about factors affecting to the management were classified in the four areas such as 'Nature(Quality) of health professional'. 'Content of OHNS', 'Delivery system of the GOHS', and 'Others'. The factors were indicated highly in 'Authority as health professional', 'Level of perception of director on the OH' and 'Physical work condition for OHNS'. The things that this study suggests in the recommendation would be summarized in such as the management and supporting system working for SSE in the OHNS is necessary to reform thoroughly. The reconsidered aspects might be in the matters of number of workplaces undertaken by nurses, development of effectively practical health documents, preparation for guideline of the laboratory test in the workpleces, establishment of convenient and encouraging support system and cooperation between other health professionals with respect and skill.

  • PDF

나트륨 섭취량 추정을 위한 음식섭취빈도조사지와 Na Index를 이용한 간이음식섭취빈도조사지의 개발 및 타당성 검증에 관한 연구 (Development and Evaluation of Validity of Dish Frequency Questionnaire (DFQ) and Short DFQ Using Na Index for Estimation of Habitual Sodium Intake)

  • 손숙미;허귀엽;이홍섭
    • 대한지역사회영양학회지
    • /
    • 제10권5호
    • /
    • pp.677-692
    • /
    • 2005
  • The assessment of sodium intake is complex because of the variety and nature of dietary sodium. This study intended to develop a dish frequency questionnaire (DFQ) for estimating the habitual sodium intake and a short DFQ for screening subjects with high or low sodium intake. For DFQ112, one hundred and twelve dish items were selected based on the information of sodium content of the one serving size and consumption frequency. Frequency of consumption was determined through nine categories ranging from more than 3 times a day to almost never to indicate how often the specified amount of each food item was consumed during the past 6 months. One hundred seventy one adults (male: 78, female: 93) who visited hypertension or health examination clinic participated in the validation study. DFQ55 was developed from DFQ112 by omitting the food items not frequently consumed, selecting the dish items that showed higher sodium content per one portion size and higher consumption frequency. To develop a short DFQs for classifying subjects with low or high sodium intakes, the weighed score according to the sodium content of one protion size was given to each dish item of DFQ25 or DFQ14 and multiplied with the consumption frequency score. A sum index of all the dish items was formed and called sodium index (Na index). For validation study the DFQ112, 2-day diet record and one 24-hour urine collection were analyzed to estimate sodium intakes. The sodium intakes estimated with DFQ112 and 24-h urine analysis showed $65\%$ agreement to be classified into the same quartile and showed significant correlation (r=0.563 p<0.05). However, the actual amount of sodium intake estimated with DFQ112 (male: 6221.9mg, female: 6127.6mg) showed substantial difference with that of 24-h urine analysis (male: 4556.9mg, female: 5107.4mg). The sodium intake estimated with DFQ55 (male: 4848.5mg, female: 4884.3mg) showed small difference from that estimated with 24-h urine analysis, higher proportion to be classfied into the same quartile and higher correlation with the sodium intakes estimated with 24-h urine analysis and systolic blood pressure. It seems DFQ55 can be used as a tool for quantitative estimation of sodium intake. Na index25 or Na index14 showed $39\~50\%$ agreement to be classified into the same quartile, substantial correlations with the sodium intake estimated with DFQ55 and significant correlations with the sodium intake estimated with 24-h urine analysis. When point 119 for Na index25 was used as a criterion of low sodium intake, sensitivity, specificity and positive predictive value was $62.5\%,\;81.8\%\;and\;53.2\%$, respectively. When point 102 for Na index14 was used as a criterion of high sodium intake, sensitivity, specificity and positive predictive value were $73.8\%,\;84.0\%,\;62.0\%$, respectively. It seems the short DFQs using Na index 14 or Na index25 are simple, easy and proper instruments to classify the low or high sodium intake group.

안동주변 농촌지역 50세 이상 주민의 신체계측치 및 생화학적 영양상태에 관한 연구 (2) (Anthropometric Measurements and Biochemical Nutritional Status of the Older Residents (50 years and over) in Andong Area (2))

  • 이혜상;권인숙;권정숙
    • 한국식품영양과학회지
    • /
    • 제37권12호
    • /
    • pp.1599-1608
    • /
    • 2008
  • 본 연구는 농촌지역 노인들의 만성질환 예방을 위한 건강증진사업에 기초 자료를 제공하고자 안동시 읍면지역 농촌의 50세 이상 주민 1,384명을 대상으로 신체계측과 생화학적 영양상태를 측정하고 평가하였으며, 이들의 관련성을 분석하였다. 평균 연령은 62.7세(남자 63.8세, 여자 62.0세)였고, 연령별 분포는 $50{\sim}59$세가 33.0%, $60{\sim}69$세가 50.0%, 70세 이상이 17.0%이었다. 평균 신장은 남녀 각각 163.7과 151.5 cm, 평균 체중은 각각 63.3과 57.3 kg, 허리둘레 평균은 각각 82.5와 86.8 cm로 신장과 체중은 국민건강영양조사보다 작았지만 여자의 허리둘레는 더 큰 것으로 나타났다. 체질량지수는 남녀 각각 23.6과 $24.9kg/m^2$로 국민건강영양조사보다 높았으며, 체지방율은 각각 21.8%와 31.8%였다. 비만 유병율이 체질량지수로는 남자 28.7%, 여자 47.3%였고, 50대 여자의 비만 유병율이 전국 평균(39.8%)보다 매우 높았다. 체지방율에 의한 비만 유병율은 남녀 각각 25.8%, 50.8%였으며, 남녀 모두 70세 이상에서 가장 높아 각각 37.5%와 58.5% 를 나타내었다. 허리둘레에 의한 복부비만은 남녀 각각 15.6%, 80.0%였으며, 50대 여자의 복부비만이 84.7%로서 전국 평균($50{\sim}54$세 60.7%, $55{\sim}59$세 69.6%)보다 매우 높았다. 수축기 혈압은 남녀 각각 136.9와 133.6 mmHg, 이완기 혈압은 각각 83.8과 82.5 mmHg로, 국민건강영양조사보다 수축기 혈압은 남자는 다소 높고 여자는 비슷하였으며, 이완기 혈압은 남녀 모두 다소 높은 것으로 나타났다. 혈색소치는 남자 14.3 g/dL, 여자 13.0 g/dL로 국민건강영양조사와 비슷하였으나, 헤마토크리트치는 남자 44.7%, 여자 39.8%로 전국 평균보다 높았다. 혈액의 지질 양상을 보면, 중성지방은 남녀 각각 98.5와 101.7 mg/dL로서 남녀 간에 유의적인 차이가 없었으나, 총 콜레스테롤치는 각각 170.0과 183.1 mg/dL, LDL-콜레스테롤치는 각각 106.8과 119.9 mg/dL로서 여자가 남자보다 더 높았으며, HDL-콜레스테롤은 각각 43.3과 42.7 mg/dL로서 성별 차이가 없었다. 국민건강영양조사보 다 중성지방, 총 콜레스테롤 및 HDL-콜레스테롤이 모두 낮았으며 낮은 총 콜레스테롤치는 낮은 HDL-콜레스테롤치에 기인한 것으로 분석되었다. 공복 혈당은 남녀 각각 96.7과 93.0 mg/dL로 여자의 공복 혈당이 국민건강영양조사에 비해 매우 낮았다. 혈액의 과산화지질 농도는 남녀 각각 4.50과 4.32 nmole/mL였으며, 정상범위에 속하기는 하지만 정상범 위에서 다소 높은 수치인 것으로 나타났다. 고혈압 유병율은 남녀 각각 58.0%와 47.2%였고, 남자는 60대(61.9%), 여자는 70세 이상 (60.2%)에서 가장 높았다. 철결핍성 빈혈은 혈색소치에 따라 남녀 각각 19.3%와 20.6%, 헤마토크리트치에 따라 각각 7.2%와 11.9%였으며, 70세 이상의 빈혈 유병율 매우 높아(혈색소 기준 남녀 각각 27.4%와 33.3%) 이들에 대한 특별한 관심이 요구된다. 저알부민혈증이 남녀 각각 9.8%와 11.7%로 단백질-열량 섭취 불량이 반영된 것으로 나타났다. 당뇨 유병율이 남자 12.0%, 여자 10.2%였으며, 70세 이상 남자의 당뇨병 유병율이 17.9%로 매우 높았다. 중성지방 이상자 비율은 남녀 각각 7.3%와 6.2%로 전국 평균보다 낮았으며, 고콜레스테롤혈증(남자 19.5%, 여자 30.5%)과 HDL-콜레스테롤 이상자 비율(남자 39.5%, 여자 42.7%)은 전국 평균보다 높았다. 이상 안동시 읍면 지역 농촌의 50세 이상 주민을 대상으로 신체계측과 생화학적 영양상태를 측정하여 분석한 결과, 고혈압 및 고콜레스테롤혈증 유병율이 높았으며, 단백질-열량 불량 상태를 말해 주는 저알부민혈증이 많은 것으로 나타났다. 그리고 70세 이상 노인들에서 철 결핍성 빈혈이 많았고, 50대 여자에서는 비만, 특히 복부 비만이 매우 심각하였으며, 70세 이상 남자에서는 당뇨병 유병율이 매우 높은 것으로 나타났다. 따라서 이 지역 50세 이상 주민을 대상으로 혈압과 혈당을 규칙적으로 측정하도록 유도하며, 소금섭취 저감화와 균형 있는 영양섭취 및 다양한 운동프로그램을 통해 체중을 줄이고 혈압을 낮출 수있는 영양중재프로그램의 운영 필요성이 매우 높은 것으로 사료된다.

허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study (One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study)

  • 김경목;이병욱;이동욱;김정수;장영도;방찬석;백종훈;이인수
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.33-37
    • /
    • 2010
  • 관상동맥질환의 진단 및 평가에 있어서 myocardial perfusion SPECT검사와 FDG를 이용한 myocardial PET검사 그리고 PET/CT에 장착된 64-slice CT를 이용한 coronary CT angiography를 동시에 실행함으로 검사의 신뢰도와 편의성을 한층 더 높이고자 한다. 먼저 약물부하 myocardial perfusion SPECT검사를 먼저 시행한다. 환자의 피폭경감을 위해서 $^{99m}Tc$-MIBI 10 mCi 로 주사하며 myocardial PET검사를 위해서 지방식을 먹지 않고 ursodeoxcholic acid 100 mg을 생수와 함께 복용하게 하여 1시간 후에 SPECT 영상을 얻는다. 이어서 myocardial FDG PET검사를 시행한다. 혈중의 지방산 농도를 낮추고 심장의 FDG섭취율을 증가시키기 위해 혈중 포도당 농도치에 따라 insulin과 Acipimox를 함께 사용하는 독창적인 경구 당 부하법을 사용하였으며, 환자의 피폭 경감을 위해서 $^{18}F$-FDG 5 mCi를 주사하고 1시간 후에 10분간 gated 영상을 얻으며 필요시 delay 영상을 얻는다. PET검사가 끝남과 동시에 환자는 동일한 position을 하고 연속해서 coronary CTA를 시행한다. 이 검사에서 가장 중요한 것은 심박동수 조절과 환자의 호흡협조이다. 심박동수를 65회 이하로 낮추기 위해 beta blocker 50 mg~200 mg을 의사와 상의하여 복용케 하고 호흡법을 충분히 연습을 시키다. 검사 직전에 isosorbide dinitrate를 3~5회 분무하여 혈관벽의 긴장을 낮추고 혈관을 확장시켜서 coronary artery의 해부학적 형태를 더욱 잘 나타낼 수 있게 한다. 촬영 시 CT 조영제를 4.0~5.0 mL/sec의 압력으로 주입하며 촬영을 한다. Coronary CTA를 이용하면 coronary artery stenosis가 잘 보이며, 약물부하 myocardial perfusion SPECT로 coronary CTA에서 보인 stenosis와 perfusion저하의 상관관계를 검토(culprit vessel 확인)할 수 있으며, FDG PET으로 hibernating myocardium 또는 infarction site의 viability를 확인할 수 있다. 한 가지 검사로 lesion site와 severity 및 치료에 대한 반응 예측이 가능함으로 약물치료, PCI, CABG 등 치료방향을 설정할 수 있다. 또한 모든 검사 과정들이 연속적으로 동시에 이루어지기 때문에 짧은 시간(3시간) 내에 one-stop으로 검사를 종료할 수 있는 큰 장점을 가지게 된다. 그러므로 이 검사법은 ischemic heart disease의 one-stop evaluation에 있어서 유용한 protocol로 보여진다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

5령유충의 배맥관운동에 대한 양이온의 영향에 관한 연구 (Studies on the Effect of Cation on the Activity at the 5th Instar Larvae of Bombyx mori)

  • 윤종관;사기언
    • 한국잠사곤충학회지
    • /
    • 제18권2호
    • /
    • pp.89-93
    • /
    • 1976
  • 동물에 대한 생리적 염류용액은 소위 링가씨액으로서 냉혈척추동물의 신경근육 심장등을 비교적 정상에 가까운 상태로 지속시키기 위한 용액으로 개구리 (Frog)의 심장의 관수실험을 하기 위하여 처방한 최초의 생리적 염류용액에 지나지 않았지만 현실에 있어서는 몇몇 동물은 물론 사람에 이르기까지 거의 완전한 생리적 용액으로 되어 있는데 가잠에 있어서는 몇가지 처방이 발표된 바는 있어도 아직 그 결과가 만족할 만한 정도에까지는 이르지 못하고 있다. 일반적으로 생리적 염류용액은 전술한 바와 같이 적출한 기관과 조직에 대하여 장시간에 걸친 정상적 기능을 유지시키기 위한 용액으로 사용되는 염류의 혼합용액이기 때문에 적당한 Ion조성 삼투압 PH를 갖도록 조제된다. 대개 생기내에서 이들의 기관과 조직을 적시는 혈청등 체액성분에 근사한 것을 사용한다. 용액의 Ion성분은 $Na^{+}$을 비롯하여 $K^{+}$, $Ca^{++}$, $Mg^{++}$ 등을 가하고 여기에 NaHCO$_3$, NaH$_2$PO$_4$등의 연형제를 첨가하므로서 PH를 조절한다. 생리적 염류용액중에 포함하여야 할 Cation의 최적농도 2종 이상의 Cation의 최적혼합비율등에 대하여 가잠유충의 배맥관 운동을 지표로 하여 이를 검토하였다. 각 Cation의 최적농도는 영점미만의 NaCl의 함유액을 기본으로 하고 여기에 각각 농도를 달리한 KCl, CaCl$_2$및 MgCl$_2$등을 조합하여 이들의 액체를 적하하므로서 5령유충의 배맥관 운동의 지속시간과 맥박수를 지표로 하여 이들 시험액의 효과를 검토한 바에 의하면 NaCl 단독일 경우에는 해부후 일시적으로 맥박수는 증가하지만 점차 정지되고 만다(일시간정도). 여기에 대하여 KCI를 가하면 일반적으로 박동시간이 연장되고 맥박수의 저하도 늦어지는 경향을 나타내고 있으며 여기에 다시 KCl와 CaCl$_2$를 가하면 그 지속시간은 더 한층 연장되었다. KCI와 CaC1$_2$의 가용은 효과가 있지만 이들의 농도와 배맥관의 활동에 있어서는 일정한 경향이 인정되지 않았고 $Ca^{++}$ 또는 $K^{+}$의 박동에 대한 작용은 이것을 분명히 할 수 없었고 $Mg^{++}$의 작용에 있어서는 배맥관에 이를 가하면 박동 지속시간에는 영향을 끼치지 않지만 맥박수는 크게 저하됨을 인정할 수 있었다.

  • PDF

급성(急性) Ethyl 알콜 중독(中毒) 흰쥐의 폐용압률(肺容壓率)과 폐포활성물질(肺胞活性物質)의 변화(變化) (Effect of Acute Ethanol Intoxication on the Pulmonary Compliance and Surfactant in Rats)

  • 이승정;주영은
    • The Korean Journal of Physiology
    • /
    • 제15권1호
    • /
    • pp.27-36
    • /
    • 1981
  • Alcohol 의 급성중독(急性中毒)으로서 폐기능중(肺機能中) 특(特)히 폐용압률(肺容壓率)과 폐포활성물질(肺胞活性物質)(surfactant)의 변화(變化)를 살펴봄으로써 alcohol 이 폐기능(肺機能) 또는 폐대사(肺代謝)에 미치고 효과(效果)의 일단(一端)을 알기 위(爲)하여 흰쥐를 재료(材料)로 하여 50% alcohol 을 체중(體重) 100 gm 당(當) 1.5 ml 씩 경구적(經口的)으로 단회투여(單回投與)하여 급성(急性) Ethyl alcohol 중독(中毒)을 일으켰다. Alcohol 중독과정(中毒過程)에서 24 시간(時間)까지 경시적(經時的)으로 혈중(血中) alcohol 농도(濃度)와 hematocrit(Hct)치(値)를 측정(測定)하고, 폐용압률(肺容壓率) 및 surfactant 중(中)의 단백량(蛋白量)과 무기인(無機燐)(Pi)를 측정(測定)하여, 정상군(正常群)과 비교(比較)하여 다음과 같은 결과(結果)를 얻었다. Alcohol 혈중농도(血中濃度)는 정상치(正常値)인 $0.17{\pm}0.01\;gm%$(평균(平均)${\pm}$표준오차(標準誤差) 이하동일(以下同一))에 비(比)하여 중독(中毒) 1시간(時間)에서 $0.71{\pm}0.02\;gm%$로 최고치(最高値)에 달(達)하고, 그후(後) 차차(次次) 낮아져서 24 시간(時間)에서는 $0.36{\pm}0.02\;gm%$이었으나, 전실험치(全實驗値)는 정상(正常)에 비(比)해서는 유의(有意)하게 높았다. Hct 치(値)는 1시간(時間)에서 $64.86{\pm}2.45%$로서 최고치(最高値)를 나타내었고, 그후(後) 계속(繼續) 정상치(正常値)인 $48.87{\pm}0.28%$에 비(比)하여 유의(有意)하게 높은 값을 유지(維持)하였다. 폐중량대(肺重量對) 체중비(體重比)(L/B 비(比))는 중독(中毒) 3시간(時間)부터 $5.49{\pm}0.61$로서 정상치(正常値)인 $7.57{\pm}0.56$에 비(比)하여 유의(有意)하게 낮아지고, 24시간(時間)까지 유의(有意)한 감소(減少)를 나타내었다. 폐용압률(肺容壓率)은 확대(擴大)(inflation)와 축소(縮小)(deflation)에서 모두 3시간(時間)까지 정상(正常)과 큰 차이(差異)가 없었으나, 6및 12 시간(時間)에서는 증가(增加)된 값을 나타내었고, 특(特)히 12 시간(時間)에서는 유의(有意)하게 높은 값을 나타내었다가, 24시간(時間)에는 정상(正常)에 가까워지는 경향(傾向)을 나타내었다. 폐세척액(肺洗滌液)의 단백량(蛋白量)은 정상(正常)의 $10.65{\pm}0.62\;mg/gm$에 비(比)하여 3시간(時間)에서 $12.36{\pm}0.35\;mg/gm$, 12시간(時間)에서 $12.70{\pm}0.74\;mg/gm$ 및 24시간(時間)에서는 $12.65{\pm}0.88\;mg/gm$로서 유의(有意)하게 높은 값을 나타내었고, Pi치(値)도 중독(中毒) 6시간(時間)부터는 높은 값을 나타내었으며, 특(特)히 12 시간(時間)에서는 $7.65{\pm}0.63\;{\mu}mol/gm$, 24시간(時間)에서는 $6.70{\pm}0.36\;{\mu}mol/gm$로서, 정상(正常)의 $5.32{\pm}0.20\;{\mu}mol/gm$에 비(比)하여 유의(有意)하게 높은 값을 나타내었다. 한편, 폐추출액(肺抽出液)의 단백량(蛋白量)은 1및 3시간(時間)에서 낮은 값을 나타내었으나, 대체(大體)로 정상(正常)과 비슷한 경향(傾向)을 나타내었고, Pi 치(値)는 대체(大體)로 높은 양상(樣相)을 나타내었으며, 특(特)히 중독(中毒) 6, 12 및 24 시간(時間)에서는 각각(各各) $17.77{\pm}1.54\;{\mu}mol/gm$, $13.92{\pm}0.78\;{\mu}mol/gm$$14.57{\pm}5.53\;{\mu}mol/gm$로서, 정상(正常)의 $10.34{\pm}0.37\;{\mu}mol/gm$에 비(比)하여, 모두 유의(有意)하게 높은 값을 나타내었다. 이상(以上)의 결과(結果)로서 alcohol 급성중독(急性中毒)에서는, surfactant 의 활성도(活性度)나 폐용압률(肺容壓率)이 증가(增加)되어 폐기능(肺機能)에 변화(變化)가 초래(招來)된다고 하겠다.

  • PDF