• Title/Summary/Keyword: Blood Pressure

Search Result 4,639, Processing Time 0.036 seconds

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Weaning Following a 60 Minutes Spontaneous Breathing Trial (1시간 자가호흡관찰에 의한 기계적 호흡치료로부터의 이탈)

  • Park, Keon-Uk;Won, Kyoung-Sook;Koh, Young-Min;Baik, Jae-Jung;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.361-369
    • /
    • 1995
  • Background: A number of different weaning techniques can be employed such as spontaneous breathing trial, Intermittent mandatory ventilation(IMV) or Pressure support ventilation(PSV). However, the conclusive data indicating the superiority of one technique over another have not been published. Usually, a conventional spontaneous breathing trial is undertaken by supplying humidified $O_2$ through T-shaped adaptor connected to endotracheal tube or tracheostomy tube. In Korea, T-tube trial is not popular because the high-flow oxygen system is not always available. Also, the timing of extubation is not conclusive and depends on clinical experiences. It is known that to withdraw the endotracheal tube after weaning is far better than to go through any period. The tube produces varying degrees of resistance depending on its internal diameter and the flow rates encountered. The purpose of present study is to evaluate the effectiveness of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotracheal tube. Methods: We analyzed the result of weaning and extubation following a 60 minutes spontaneous breathing trial with simple oxygen supply through the endotracheal tube in 18 subjects from June, 1993 to June, 1994. They consisted of 9 males and 9 females. The duration of mechanical ventilation was from 38 hours to 341 hours(mean: $105.9{\pm}83.4$ hours). In all cases, the cause of ventilator dependency should be identified and precipitating factors should be corrected. The weaning trial was done when the patient became alert and arterial $O_2$ tension was adequate($PaO_2$ > 55mmHg) with an inspired oxygen fraction of 40%. We conducted a careful physical examination when the patient was breathing spontaneously through the endotracheal tube. Failure of weaning trial was signaled by cyanosis, sweating, paradoxical respiration, intercostal recession. Weaning failure was defined as the need for mechanical ventilation within 48 hours. Results: In 19 weaning trials of 18 patients, successful weaning and extubation was possible in 16/19(84.2 %). During the trial of spontaneous breathing for 60 minutes through the endotracheal tube, the patients who could wean developed slight increase in respiratory rates but significant changes of arterial blood gas values were not noted. But, the patients who failed weaning trial showed the marked increase in respiratory rates without significant changes of arterial blood gas values. Conclusion: The result of present study indicates that weaning from mechanical ventilation following a 60 minutes spontaneous breathing with $O_2$ supply through the endotracheal tube is a simple and effective method. Extubation can be done at the same time of successful weaning except for endobronchial toilet or airway protection.

  • PDF

Effects of NG-monomethyl-L-arginine and L-arginine on cerebral hemodynamics and energy metabolism during reoxygenation-reperfusion after cerebral hypoxia-ischemia in newborn piglets (급성 저산소성 허혈성 뇌손상이 유발된 신생자돈에서 재산소-재관류기 동안 NG-monomethyl-L-arginine과 L-arginine이 뇌의 혈역학 및 에너지 대사에 미치는 영향)

  • Ko, Sun Young;Kang, Saem;Chang, Yun Sil;Park, Eun Ae;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.3
    • /
    • pp.317-325
    • /
    • 2006
  • Purpose : This study was carried out to elucidate the effects of nitric oxide synthase(NOS) inhibitor, NG-monomethyl-L-arginine(L-NMMA) and nitric oxide precursor, L-arginine(L-Arg) on cerebral hemodynamics and energy metabolism during reoxygenation-reperfusion(RR) after hypoxia-ischemia(HI) in newborn piglets. Methods : Twenty-eight newborn piglets were divided into 4 groups; Sham normal control(NC), experimental control(EC), L-NMMA(HI & RR with L-NMMA), and L-Arg(HI & RR with L-Arg) groups. HI was induced by occlusion of bilateral common carotid arteries and simultaneously breathing with 8 percent oxygen for 30 mins, and followed RR by release of carotid occlusion and normoxic ventilation for one hour. All groups were monitored with cerebral hemodynamics and cytochrome $aa_3$ (Cyt $aa_3$) using near infrared spectroscopy(NIRS). $Na^+$, $K^+$-ATPase activity, lipid peroxidation products, and tissue high energy phosphate levels were determined biochemically in the cerebral cortex. Results : In experimental groups, mean arterial blood pressure, $PaO_2$, and pH decreased, and base excess and blood lactate level increased after HI compared to NC group(P<0.05). These variables subsequently returned to baseline after RR except pH. There were no differences among the experimental groups. In NIRS, oxidized hemoglobin($HbO_2$) decreased and hemoglobin(Hb) increased during HI(P<0.05) but returned to base line immediately after RR; 40 min after RR, the $HbO_2$ had decreased significantly compared to NC group(P<0.05). Changes of Cyt $aa_3$ decreased significantly compared to NC after HI and recovered at the end of the experiment. Significantly reduced cerebral cortical cell membrane $Na^+$, $K^+$-ATPase activity and increased lipid peroxidation products(P<0.05) were not improved with L-NMMA or L-Arg. Conclusion : These findings suggest that NO is not involved in the mechanism of HI and RR brain damage during the early acute phase of RR.

The Change of The Effect on The Subcutaneous Fat Area and Visceral Fat Area by The Functional Electrical Stimulation and Aerobic Exercise (기능적 전기 자극과 유산소 운동이 복부비만의 피하지방과 내장지방에 미치는 효과)

  • Oh Sung-tae;Lee Mun-hwan;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.85-123
    • /
    • 2004
  • Back ground : Subcutaneous fat area is the main factor involved in replacement disease and arteriosclerosis. Simple weight control is the appropriate medical treatment. It's understood that weight reduction does not only reduce the fat concentrations in blood but also reduces blood pressure, improves glucose levels in diabetes patients and reduces incidents of heart disease. there are several methods for reducing fat in the abdominal region but their effectiveness is not folly understood. one method is electrical stimulation of the problem areas. Method : From May 1st 2002 to October 31st. The 15 subjects who received medical examination were aged between 25 and 53 and were of mixed gender. The subjects were divided into two groups one to received functional electrical stimulation and the other a control group. Using Broca's criterion for judging fat grades. I analysed the differences between the two groups before and after the treatment. Subjects received functional electrical stimulation on the abdominal muscle intensity 50Hz. They received this treatment 4 days a week for 40 minutes a day. In the case of aerobic exercise, at the Treadmill, we used it with the intensity of $75\%$ maximum heart rate (220-age). Result 1)After functional electrical stimulation in the case of male subjects, the weight was reduced 1.93kg, obesity $2.60\%$, fat mass 2.73kg, Percent body fat $4.40\%$, waist circumference 6.53cm, circumference of hips 5.53cm. On the other side, the quality of muscle was increased at the rate of 1.03kg, but it's not attentional level. The subcutaneous fat area was reduced by $26.63cm^2$, the visceral fat area was reduced by $43.00cm^2$, In the female subjects, we can see the reduction of fat grade by $26.63cm^2$, the quantity of body fat by 1.5kg, percent body fat by $1.77\%$, circumference of waist by 4.02cm, circumference of hips by 3.67cm, weight by 1.40kg but was increased 0.72kg at the quantity of muscles. We can see the reduction also in the subcutaneous fat area $24.03cm^2$, the visceral fat area by $25.36cm^2$. 2)After aerobic exercise, on the male subjects, we can see reduction of weight by 3.36kg, obesity by $4.00\%$, fat mass by 2.83kg and we can see increase at the soft lean mass by 2.96kg, but we can see reduction, the percent body fat by $3.03\%$, fat distribution by $0.023\%$, circumference of waist by 3.10cm, circumference of hips by 2.23cm. The female subjects show a reduction in the weight by 2.48kg, percent body fat by $2.20\%$, show an increase in the soft lean mass by 1.54kg. We can see a reduction in the quantity of fat mass by 2.32kg, the percent body fat by $2.80\%$, the circumference of waist by 2.16cm, the circumference of hips by 2.68cm, the fat distribution by $0.016\%$, the subcutaneous fat area by $15.25cm^2$ the visceral fat area by $11.52cm^2$. After aerobic exercise, we can't see the attentional change at the total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. 3)After the application of functional electrical stimulation and aerobic exercise, in result of measurement on the body ingredient, we could see the weight reduction and increase the quantity of muscle with the male group who exercised aerobic. We can see the attentional rate on the electrical stimulation about abdominal fat rate, circumference of waist, circumference of hips. The other hand, I couldn't see the attentional differences between the two groups in the rate of fatness and quantity of body fat and the rate of body fat. There isn't any attentional difference in the area of fat under skin, on the contrary, There is attentional difference in the fat in the internal organs area at the electrical stimulation site. We can't see the attentional change of total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol between electrical stimulation and aerobic exercise. 4)After execution of functional electrical stimulation and aerobic exercise, in result of measurement on change of body ingredient among female objects, We could see weight reduction, increase at muscle quantity in the aerobic exercise group. We could see the attentional differences in the rate of fatness, the rate of abdominal region, the circumference which received electrical stimulation. But, we couldn't see the attentional differences between two groups in the quantity of body fatness, the circumference of hips. The subcutaneous fat area doesn't show the attentional differences. On the Contrary, we could see lots of differences in the visceral fat area of the electrical stimulation group. Conclusion The results show that functional electrical stimulation and aerobic exercise have insignificant differences when if comes to total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. Though there is affirmative change in body ingredient after both electrical stimulation and aerobic exercise. Functional electrical stimulation is more effective on the subcutaneous fat area and in changing visceral fat area. There fore. It is concluded that the physical therapy is more effective in the treatment of abdominal fatness.

  • PDF

Variation of Vital Sign according to Time in Full Immersion of Hot and Cool Bath (온.냉욕 전신침수욕시 기간에 따른 vital sign의 변화)

  • Yi, Seung-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.3
    • /
    • pp.35-49
    • /
    • 1996
  • This study was conducted to see variation of vital sign of hot and cool bath according to time, a questionnair survey and measurement was carried out for 32 students(sophomore) of department of physical therapy Andong Junior College on the 27th of June, 1995. The result were as follows: The average systolic blood pressure(SBP) of stability for 32 college students who were measured was 105.3mmHg, the average diastolic blood pressure(DBP) was 67.3mmHg, the average pulse frequency(PF) was 70.7(frequency/min), the average respiratory frequency (RF) was 15.6 (frequency/min), and the body temperature(BT) was $36.6^{\circ}C$. As time went on, SBP for 32 students who were measured in hot bath according to stability, 3 min, 6 min, 9 min, and 12 min was decreased(105.15 mmHg, 104.69mmHg, 104.24 mmHg, 103.03 mmHg, and 96.69 mmHg)(P=0.3006). SBP was decreased in cool bath, too(105.15 mmHg, 103.33 mmHg, 103.33 mmHg, and 100.91 mmHg), but it at 12 min was a little higher(l03.09 mmHg)(P=0.7566). As time went on, DBP according to stability, 3 min, 6 min, 9 min, and 12 minutes was decreased in hot bath(66.82 mmHg, 65.45 mmHg, 64.54 mmHg, 63.03 mmHg, and 59.39 mmHg)(P=0.0906). It was similar in cool bath(66.82 mmHg, 67.87 mmHg, 68.48 mmHg, 67.87 mmHg, and 68.78)(P=0.9654). As time went on, PF was significantly increased in hot bath(70.42 times, 86.96 times, 93.57 times, 99.30 times, and 101.78 times)(P=0.0001). It was a little increased in cool bath, too (70.42 times, 70.85 times, 71.63 times, 71.06 times, and 71.45 times)(P=0.9803). As time went on, RF was significantly increased in hot bath(15.75 times, 19.09 times, 22.09 times, 24.94 times, and 26.48 times)(P=0.0001). I t in cool bath of stability, 3 min, and 6 min was a little increased(15.75 times, 19.30 times, 19.39 times), but it in 9 min(18.67 times), and 12 min(18.09 times) was a little decreased(P=0.0176). As time went on, BT was significantly increased in hot bath($36.63^{\circ}C,\;37.45^{\circ}C,\;37.81^{\circ}C,\;38.12^{\circ}C,\;38.33^{\circ}C$)(P=0.0001). It was a little increased in cool bath of stability and 3 min($36.63^{\circ}C,\;37.40^{\circ}C$), but others are similar($37.33^{\circ}C,\;37.37^{\circ}C$, and $37.36^{\circ}C$)(P=0.0001). It was revealed by this study, SBP and DBP according to time in hot and cool bath were decreased. PF, RF, and BT in hot bath were higher, RF and BT in cool bath were higher too. but PF was similar.

  • PDF

Effect of Acute Ethanol Intoxication on the Pulmonary Compliance and Surfactant in Rats (급성(急性) Ethyl 알콜 중독(中毒) 흰쥐의 폐용압률(肺容壓率)과 폐포활성물질(肺胞活性物質)의 변화(變化))

  • Lee, Seung-Jung;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.27-36
    • /
    • 1981
  • Relatively little has been done on the metabolic changes of the lung produced by the excessive alcohol ingestion to the point of the acute alcohol intoxication. In the present study, an effort was made to clarify the possible changes of the pulmonary surfactant system by the acute alcohol ingestion. The dynamic pulmonary compliance and the levels of protein and inorganic phosphorus (Pi) of both lung lavage and extract were chosen as the parameters of the pulmonary surfactant activities. The albino rats of both sexes were used, and 1.5 ml of 50% ethanol per 100 g body weight was given by oral intubation, and the experiment was performed at 1, 3, 6, 12, and 24 hours after the alcohol ingestion. The rat was sacrificed by cutting the carotid arteries, and blood sample for the determination of hematocrit(Hct) and the blood alcohol concentration was obtained. Both lungs were completely removed without dammage to the lung tissue, and the pulmonary compliance was measured by the changes of pressure-volume(P-V) curves by inflating or deflating the lung with air. Immediately after the P-V curves were recorded, the lung lavage was obtained by washing the lobes with 15ml of isotonic saline 3 times with a syringe. Next, total lungs were homogenized and filtered to obtain the lung extract. The protein and Pi levels were measured using the lung lavage and extract as the samples, and the lung/body weight ratio(L/B ratio) was also calculated. The results thus obtained were compared with the normal values and summarized as follows. The blood alcohol concentration reached the highest level of $0.71{\pm}0.02\;g\;%$ at 1 hr and gradually decreased until 24 hrs$(0.36{\pm}0.02\;g%)$ after the alcohol ingestion, but all the experimental groups showed significant increase comparing with the normal. The highest Hct value was obtained at 1hr$(64.86{\pm}2.45%)$ and significantly elevated value was continued throughout the experiment. The L/B ratio was significantly lowered from 3hrs until 24hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The pulmonary compliance at inflation and deflation did not change appreciablly from the normal until 3 hrs after the alcohol ingestion but from 6 th hr on, a generally elevated value was observed with a significant value at 12 hrs and gradual recovery to the normal value at 24 hrs after the alcohol ingestion. The protein level of the lung lavage stowed a significantly increased value of $12.36{\pm}0.35\;mg/gm(3rd hr)$, $12.70{\pm}0.74\;mg/gm(12 th hr)$, and $12.65{\pm}0.88\;mg/gm(24 th hr)$, respectively, comparing with the normal value of $10.65{\pm}0.62\;mg/gm$, and the Pi level also showed a similar tendency of significant increase at 12th hr $(7.65{\pm}0.63\;{\mu}mol/gm)$ and 24 th hr$(6.70{\pm}0.36\;{\mu}mol/gm)$ comparing with the normal value of $5.32{\pm}0.20\;{\mu}mol/gm$. The protein level of the lung extract in the alcohol group was generally similar to the normal value with a slight decrease at 1st and 3 rd hr, tut the Pi level of the lung extract was generally increased in the alcohol group, and a significant increase was observed at 6 th hr$(17.77{\pm}1.54\;{\mu}mol/gm)$, 12 th hr$(13.92{\pm}0.78\;{\mu}mol/gm)$ and 24 th hr$(14.57{\pm}0.53\;{\mu}mol/gm)$ of the alcohol ingestion comparing with the normal value of $10.34{\pm}0.37\;{\mu}mol/gm$. From the above, it may be concluded that the acute alcohol intoxication produces the metabolic changes of the lungs by the increased surfactant activities and elevated pulmonary compliance.

  • PDF

A Study of the Health Promoting Life Style in Rural Area (일부 농촌주민의 건강증진 생활양식 수행정도)

  • Jung, Young-Ok;Kim, Sang-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.133-148
    • /
    • 1995
  • This study was to identify the factors affecting the performance in health promoting lifestyle and measuring health promoting lifestyle. The subjects for this study were all adult in rural area, Kakbuk Nyun, Chung-do Gun, Kyungpook, Korea. The data were collected during the period from April 1 to April 30, 1995. The instruments used for this study were the health promoting lifestyle by Park(1995). The results of this study are as follows. Health condition felt by the subjects was worse in female group and was getting worse according as the age increase. According to health promoting life style implementation questionnaire, more than half of the subjects responded "never" in deep breathing 3 times a day item and non-smoking item; more than half of the subjects responded "yes" in 3 meal a day item, home-cooked meals item, never to omit breakfast item and frequent wearing of cotton underwear item. Health promoting life style implementation by health condition is higher in healthy group and frequency of consulting a specialist is higher in unhealthy group. Health promoting life style implementation by sex is higher in male group. Frequency, of consulting a specialist and non-excessive drinking are higher in female group. Health promoting life style implementation by age showed that the implementation of never omitting breakfast, keeping early hours and proper sleeping is higher in old age group ; that of enjoying hobby, pastime, cleaning as well as reading health books is higher in young age group. Health promoting life style implementation by religion showed that the implementation of deep breathing 3 times more a day, regular checking of blood pressure, never having non-healthful food and keeping right posture in sitting and standing is higher in religion group. Health promoting life style implementation by education is higher in highly-educated group ; the implementation of keeping early hours is higher in low-educated group. Health promoting life style implementation by marriage state showed that the implementation of deep breathing 3 times more a day, twenty minutes of brisk physical movement three or four times a week, enjoying his or her own time, relaxation to relieve from tension and pressure and equalized movement of each part of body is higher in unmarred group ; that of having elaborately cooked food, never omitting three meals a day and keeping early hours is higher in married group. Health promoting life style implementation by the number of family members showed that more-member-group has more plans and objectives for their future. Health promoting life style implementation by family type showed that the implementation of reading health books and articles, living with positive way of thinking and enjoying favorite hobby in pastime is higher in nuclear families ; that of having three meals a day never omitting breakfast is higher in large families.

  • PDF

Relationship of Compliance and Oxygen Transport in Experimental Acute Respiratory Failure during Positive End-Expiratory Pressure Ventilation (실험적 급성호흡부전에서 호기말양압에 의한 폐유순도와 산소운반의 변화 및 상관관계 - 호흡부전의 기전에 따른 차이 -)

  • Lee, Sang-Do;Yoon, Se-Jin;Lee, Bok-Hee;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 1993
  • Background: Positive end, expiratory pressure (PEEP) has become one of the standard therapies for adult respiratory distress syndrome (ARDS). Total static compliance has been proposed as a guide to determine the size of PEEP ('best PEEP') which is of unproven clinical benefit and remains controversial. Besides increasing functional residual capacity and thus improving oxygenation, PEEP stimulate prostacyclin secretion and was proposed for the treatment of acute pulmonary embolism. But little is known about the effect of PEEP on hemodynamic and gas exchange disturbances in acute pulmonary embolism. Methods: To study the validity of total static compliance as a predictor of 'best PEEP' in ARDS and acute pulmonary embolism, experimental ARDS was induced in mongrel dog with oleic acid and acute pulmonary embolism with autologous blood clot. Then hemodynamic and gas exchange parameters were measured with serial increment of PEEP. Results:In ARDS group, total static compliance and oxygen transport were maximal at 5 cm$H_2O$, and decreased thereafter (p<0.05). With increment of PEEP, arterial oxygen tension ($PaO_2$) and arterial carbon dioxide tension ($PaCO_2$) increased and cardiac output and physiological shunt decreased. In pulmonary embolism group, total static compliance, oxygen transport, physiological shunt and cardiac output decreased and $PaO_2$ and $PaCO_2$ increased with increment of PEEP (p<0.05). Comparing the change induced by increment of PEEP by 1 cm$H_2O$ in ARDS group with that in pulmonary embolism group, there was no significant difference between two groups except cardiac output which decreased more in pulmonary embolism group (p<0.05). In ARDS group, oxygen transport and total static compliance increased after PEEP application, and total static compliance was maximal at the PEEP level where oxygen transport was maximal. However in pulmonary embolism group, oxygen transport and total static compliance decreased after application of PEEP. There was significant correlation between change of total static compliance and change of oxygen transport in both groups. Conclusion: In both ARDS and acute pulmonary embolism, it can be concluded that total static compliance is useful as a predictor of 'best PEEP'.

  • PDF

The Experimental Study for Myocardial Preservation Effect of Ischemic Preconditioning (허혈성 전조건화 유발이 심근보호에 미치는 영향에 관한 실험적 연구)

  • 이종국;박일환;이상헌
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.119-130
    • /
    • 2004
  • Decrease in cardiac function after open heart surgery is due to an ischemia induced myocardial damage during surgery, and ischemic preconditioning, a condition in which the myocardial damage does not accumulate after repeated episodes of ischemia but protects itself from damage after prolonged ischemia due to myocytes tolerating the ischemia, is known to diminish myocardial damage, which also helps the recovery of myocardium after reperfusion, and decreases incidences of arrythmia. Our study is performed to display the ischemic preconditioning and show the myocardial protective effect by applying cardioplegic solution to the heart removed from rat. Material and Method: Sprague-Dawley male rats were used, They were fixed on a modified isolated working heart model after cannulation. The reperfusion process was according to non-working and working heart methods and the working method was executed for 20 minutes in which the heart rate, aortic pressure, aortic flow and coronary flow were measured and recorded. The control group is the group which the extracted heart was fixed on the isolated working heart model, recovered by reperfusion 60 minutes after infusion and preserved in the cardioplegic solution 20 minutes after the working heart perfusion and aortic cross clamp, The thesis groups were divided into group I, which ischemic hearts that were hypoxia induced were perfused by cardioplegic solution and preserved for 60 minutes; group II, the cardioplegic solution was infused 45 seconds (II-1), 1 minutes (II-2), 3 minutes (II-3), after the ischemia induction, 20 minutes after working heart perfusion and aortic cross clamp; and group III, hearts were executed on working heart perfusion for 20 minutes and aortic cross clamp was performed for 45 seconds (III-1), 1minute (III-2), 3 minutes (III-3), reperfused for 2 minutes to recover the heart, and then aortic cross clamping was repeated for reperfusion, all the groups were compared based on hemodynamic performance after reperfusion of the heart after preservation for 60 minutes. Result: The recovery time until spontaneous heart beat was longer in groups I, II-3, III-2 and III-3 to control group (p<0.01). Group III-1 (p<0.05) had better results in terms of recovery in number of heart rates compared to control group, and recovered better compared to II-1 (p<0.05). The recovery of aortic blood pressure favored group III-1 (p<0.05) and had better outcomes compared with II-1 (p<0.01). Group III-1 also showed best results in terms of cardiac output (p<0.05) and group III-2 was better compared to II-2 (p<0.05). Group I (p<0.01) and II-3 (p<0.05) showed more cardiac edema than control group. Conclusion: When the effects of other organs are dismissed, protecting the heart by infusion of cardioplegic solution after enforcing ischemia for a short period of time before the onset of abnormal heart beats for preconditioning has a better recovery effect in the cardioplegic group with preconditioning compared to the cardioplegic solution itself. we believe that further study is needed to find a more effective method of preconditioning.