• Title/Summary/Keyword: Blood Circulation

Search Result 782, Processing Time 0.033 seconds

Improvement of a sensor unit for wrist blood pressure monitor (손목형 혈압계의 센서부 개선에 대한 연구)

  • Koo, Sang-Jun;Kwon, Jang-Wan;Park, Yong-Man;Ayuznara, Odgerel;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.380-382
    • /
    • 2007
  • As the society changes more to the aging society in future, many healthcare product are developed and distributed more on the market. The digital wrist band tye blood pressure device for home use are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially. It is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement accuracy of blood pressure is not enough compared to the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design fa capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  • PDF

Numerical Study on Blood Flow Characteristics in a Arteriovenous Graft with Delivered dose During Hemodialysis (혈액 투석 시 주사침에서의 투석량에 따른 인조혈관 내부 유동 특성에 관한 수치해석 연구)

  • Kim, J.Y.;Ro, K.C.;Ryou, H.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.469-476
    • /
    • 2011
  • Hemodialysis is essential for patients with end stage renal failure. It is important to improve the patency rate and to minimize occurrence of the stenosis. Also, the blood flow to the artificial kidney can affect the blood flow characteristics though arteriovenous graft. Thus, the delivered dose are important factors for analyzing hemodynamic characteristics during hemodialysis access. In this study, the numerical analysis was performed for the effect of the delivered dose during hemodialysis access on the blood flow through the graft. As a result, The adverse pressure gradient occurred in case of a larger delivered dose through a catheter than standard dose and the flow instability increased. Also the circulation flow appeared largely at anastomotic site of the vein when the delivered dose was exceeded about half blood flow of inlet blood flow.

  • PDF

A Multi-scale Simulation Model of Circulation Combining Cardiovascular Hemodynamics with Cardiac Cell Mechanism (심근세포-심혈관계 혈류역학이 결합된 복합적 순환계 모델에 관한 연구)

  • Ko Hyung Jong;Leem Chae Hun;Shim Eun Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.12
    • /
    • pp.1164-1171
    • /
    • 2004
  • A new multi-scale simulation model is proposed to analyze heart mechanics. Electrophysiology of a cardiac cell is numerically approximated using the previous model of human ventricular myocyte. The ion transports across cell membrane initiated by action potential induce an excitation-contraction mechanism in the cell via cross bridge dynamics. Negroni and Lascano model (NL model) is employed to calculate the tension of cross bridge which is closely related to the ion dynamics in cytoplasm. To convert the tension on cell level into contraction force of cardiac muscle, we introduce a simple geometric model of ventricle with a thin-walled hemispheric shape. It is assumed that cardiac tissue is composed of a set of cardiac myocytes and its orientation on the hemispheric surface of ventricle remains constant everywhere in the domain. Application of Laplace law to the ventricle model enables us to determine the ventricular pressure that induces blood circulation in a body. A lumped parameter model with 7 compartments is utilized to describe the systemic circulation interacting with the cardiac cell mechanism via NL model and Laplace law. Numerical simulation shows that the ion transports in cell level eventually generate blood hemodynamics on system level via cross bridge dynamics and Laplace law. Computational results using the present multi-scale model are well compared with the existing ones. Especially it is shown that the typical characteristics of heart mechanics, such as pressure volume relation, stroke volume and ejection fraction, can be generated by the present multi-scale cardiovascular model, covering from cardiac cells to circulation system.

A Case Report on Posterior Circulation Cerebral Infarction with Early Neurological Deterioration in an Elderly Patient with Chronic Kidney Disease (고령의 만성콩팥병 환자에서 발생한 초기 신경학적 악화가 동반된 후방순환뇌경색 치험 1례)

  • Kim, Jun-seok;Lee, Yoo-na;An, Yu-min;Baek, Kyung-min
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.5
    • /
    • pp.727-737
    • /
    • 2021
  • Objectives: This study investigated the effect of Korean medicine on an elderly patient with posterior circulation cerebral infarction, chronic kidney disease (CKD), and early neurological deterioration (END). Methods: The patient, who already had CKD, was treated with Korean medicine, comprising herbal medicine, acupuncture, moxa, and cupping combined with Western medicine (antiplatelet, diabetes) and physical therapy. A manual muscle test (MMT) and a modified Barthel index (MBI) were used to observe the treatment effects, and blood tests were performed to check estimated glomerular filtration rate (eGFR), creatinine and blood urea nitrogen (BUN), which represent renal function. Results: After the treatment, MMT, MBI, and renal function scores had increased. Conclusions: This study suggests that Korean medicine can effectively treat posterior circulation cerebral infarction with END in CKD, but further studies should be conducted.

Comparison of normal and replantation digital blood flow using photo-plethysmography (Photo-Plethysmography를 이용한 정상과 재접합 수지 혈류량의 비교)

  • Nam, Ki-Chang;Kim, Sung-Woo;Rah, Dong-Kyun;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.322-324
    • /
    • 2004
  • Up to the present, digital replantation patients has appealed different symptoms due to blood circulatory failure. But, the level of blood circulatory failure has been evaluated only by clinical symptoms, or angiography. According to the cases of digit replantation is increasing, then objective evaluation methods of the level of blood circulation failure is needed other than patient's subjective symptoms and complaints. Although angiography, doppler, electromagnetic flowmeter, laser blood flowmeter, mechanical blood flowmeter has been used for the evaluation of the blood circulatory failure, the result was affected by time, place, surrounding temperature, patient's body temperature, and even emotion. Therefore, it is pointed out with lack of availability, feasibility and reproducibility. Thus, we compared digital blood flow of dominant hand to non dominant hand, and replanted fingers to opposite normal fingers from developed photo-plethysmography. The average digital blood flow showed no difference in normal digits each other, but, replanted digits showed average of 53% (9 - 100 %) compare to opposit normal digits. As it measure relative blood flow for circulatory failure of tissue such as fingers and toes more sensitively, reliably. In conclusion, it is expected that photo- plethysmography will be very useful for diagnosis, curative effect, prognosis of blood circulatory failure in digital replantation patient.

  • PDF

Effects of Acai Berry Ethanolic Extracts on Production of Nitric Oxide and Activity of Angiotensin Converting Enzyme Related to Blood Circulation (혈액순환과 관련하여 nitric oxide 생성과 angiotensin converting enzyme 활성에 미치는 Acai berry 에탄올 추출물의 영향)

  • Nam, Hyang;Lee, Su-Gyeong;Kim, Deok Won;Kim, Joo Wan;Kim, Ki Young;Kim, Sung Goo;Kim, Moon-Moo;Chung, Kyung Tae
    • Journal of Life Science
    • /
    • v.23 no.6
    • /
    • pp.743-750
    • /
    • 2013
  • The aim of this study is to develop a supplementary therapeutic agent capable of promoting vascular circulation. The effects of Acai berry ethanolic extracts (ABEE) on activity of angiotensin converting enzyme from rabbit lung, production of nitro oxide in both murine macrophage cells and vascular endothelial cells as well as antioxidant effects were investigated in this study. First of all, it was observed the direct effects of ABEE on reducing power and antioxidant effect lipid peroxidation. In addition, ABEE showed a protective effect on DNA oxidation induced by hydroxyl radical. Furthermore, ABEE at 0.01% exerted approximately 50% inhibition on activity of angiotensin converting enzyme. ABEE increased the production of nitric oxide in endothelial cells, but decreased the induction of nitric oxide stimulated by lipopolysaccharide in microphage. The expression levels of superoxide dismutase (SOD)-2 and -3 were enhanced by ABEE treatment, however, the expression level of SOD-1 remained constant. Moreover, the expression level of nitric oxide synthases-1 (NOS-1), a constitutive enzyme, was increased by ABEE, but that of NOS-2, a inducible enzyme, was constant. It was also found that the level of Nrf-2, a transcription factor of SOD, was increased by ABEE. Therefore, these results demonstrate that ABEE could promote blood circulation via above actions, suggesting that may be helpful for health of blood vessel.

Chitosan Nanoparticle System for Improving Blood Circulation (혈행개선을 위한 키토산 나노입자화)

  • Lee, Ji-Soo;Yoon, Hyun-Sook;Kim, Eun Suh;Nam, Hee Sop;Lee, Hyeon Gyu
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.153-158
    • /
    • 2016
  • The principal objective of this study was to produce a chitosan nanoparticle (NP) system for improving blood circulation. Chitosan NPs were prepared using fucoidan and $poly-{\gamma}-glutamic$ acid (PGA), denoted as CS/Fu and CS/Fu/PGA NPs, respectively. As the chitosan concentration was increased, the activated partial thromboplastin time (APTT) of the NPs significantly increased (p<0.05). When the concentration of fucoidan and ${\gamma}-PGA$ was 5-20 and $1-10{\mu}g/mL$, respectively, the size of the CS/Fu and CS/Fu/PGA NPs was approximately 200 and 100 nm, respectively. With an increase in the fucoidan and PGA concentration, the APTT of CS/Fu and CS/Fu/PGA NPs significantly increased (p<0.05). These results suggest that CS/Fu and CS/Fu/PGA NPs could be used as a potent NP system for improving blood circulation.

Effects of Hibiscus syriacus Extracts on Antioxidant Activities and Blood Circulation Improvement (무궁화 추출물의 항산화 활성 및 혈액 순환 개선에 미치는 효과)

  • Shin, Yu-Bin;Ha, Bae-Jin
    • Journal of Life Science
    • /
    • v.26 no.12
    • /
    • pp.1415-1421
    • /
    • 2016
  • This study was worked to investigate the antioxidant activity and the blood circulation improvement effect of two Hibiscus syriacus extracts divided into fermented H. syriacus extract and non-fermented H. syriacus extract. As the results of in vitro experiment, both of fermented H. syriacus extract and non-fermented H. syriacus extract had the DPPH free radical scavenging effect and the high contents of polyphenol and flavonoid known as antioxidant components in dose-dependent manner. Six weeks female C57BL/6 mice were divide into four groups and fed high diets for 28 days. Also fermented H. syriacus extract and non-fermented H. syriacus extract was daily intraperitoneal administration for 28 days at 2 mg/kg of body weight of mice. In vivo C57BL/6 mice experiment of normal diet group (NOR), high-fat diet group (CON), high-fat diet plus fermented H. syriacus extract group (FHS) and high-fat diet plus non-fermented H. syriacus extract group (NFHS), each of total cholesterol, triglyceride and low density lipoprotein (LDL) was decreased in both of FHS and NFHS groups, meanwhile high density lipoprotein (HDL) was increased (p<0.01). Conclusion, the results confirmed that H. syriacus containing the high contents of the antioxidant activity components had the significant effects of blood circulation improvement.

In-vitro study on the hemorheological characteristics of chicken blood in microcirculation

  • Ji, Ho-Seong;Lee, Jung-Yeop;Lee, Sang-Joon
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.89-95
    • /
    • 2007
  • The flow characteristics of chicken blood in a micro-tube with a $100{\mu}m$ diameter are investigated using a micro-Particle Image Velocimetry (PIV) technique. Chicken blood with 40% hematocrit is supplied into the micro-tube using a syringe pump. For comparison, the same experiments are repeated for human blood with 40% hematocrit. Chicken blood flow has a cell-free layer near the tube wall, and this layer's thickness increases with the increased flow speed due to radial migration. As a hemorheological feature, the aggregation index of chicken blood is about 50% less than that of human blood. Therefore, the non-Newtonian fluid features of chicken blood are not very remarkable compared with those of human blood. As the flow rate increases, the blunt velocity profile in the central region of the micro-tube sharpens, and the parabolicshaped shear stress distribution becomes to have a linear profile. The viscosity of both blood samples in a low shear rate condition is overestimated, while the viscosity in a high shear rate range is underestimated due to radial migration and the presence of a cell-depleted layer.

Effect of 10 Weeks Smart Machine Circulation Exercise on Body Composition, Lung Function, Blood Lipids and Insulin Resistance in Obesity Middle-aged Women (10주간 스마트머신 순환운동이 비만 중년여성의 체조성, 폐기능, 혈중지질 및 인슐린 저항성에 미치는 영향)

  • Kim, Min-Chan;Ha, Soo-Min;Koh, Su-Han;Kim, Jong-Won;Kim, Do-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.951-962
    • /
    • 2021
  • The purpose of this study was to analyze the effects of smart machine circulation exercise on body composition, lung function, blood lipid and insulin resistance in obesity middle-aged women among 40-60 years by dividing them into a smart machine circulation exercise group(n=8), and control group(n=6). The smart machine circulation exercise program included 55-minutes sessions thrice each week at the following intensities: The strength of aerobic exercise is applied to smart machines by linking the smart machine with the POLAR T31; the 1-4 week is 40-50%HRR, 5-8 week is 50-60%HRR, and 9-10 week is 60-70%HRR. The strength of the resistance exercise was tested using a smart machine based on the constant velocity motion, and then, using the 1-RM data value, applied 40% 1-RM for 1-4 weeks, 60% 1-RM for 5-8 weeks, and 80% 1-RM for 9-10 week. As a results, body composition indicated that weight, BMI, %BF, WHR had a significant interaction effect. Lung function indicated that FVC levels significantly changes in the exercise group and the between groups difference in changes at 10week was significant. Also, FVC and FEV1 significantly showed interaction effect. TC, TG and HDL-C levels significantly changes in smart machine circulation exercise group and the between-group difference in changes after 10 weeks was significant. TC, TG and HDL-C significantly showed interaction effect. Insulin resistance demonstrated that Insulin, Glucose and HOMA-IR levels significantly showed difference over 10 weeks between group. Therefore, the 10 weeks smart machine circulation exercise positively effects on the body composition, lung function, blood lipids, and insulin resistance in obesity middle-aged women and this smart machine circulation exercise can improve their obesity and prevent obesity.