• Title/Summary/Keyword: Blood Chemical Analysis

Search Result 180, Processing Time 0.039 seconds

Four-week Repeated Dose Toxicity Test for Myelophil in SD Rats

  • Jung, Jong-Mi;Shin, Jang-Woo;Son, Jin-Young;Seong, Nak-Won;Seo, Dong-Seok;Cho, Jung-Hyo;Cho, Chong-Kwan;Son, Chang-Gue
    • The Journal of Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2009
  • Aim : To evaluate the pharmaceutical safety of the herbal formula Myelophil, composed of Astragali Radix and Salviae Radix, via systemic subacute toxicological study using SD rats. Methods : Forty male and 40 female SD rats were fed with Myelophil (5000, 2500 or 1250 mg/10 mL/kg) or distilled water for four weeks. Adverse effects were examined intensively by comparing the differences between normal and drug-administered groups using clinical signs, necropsies, histopathologic findings, hematology, urinalysis, and blood biochemical analysis. Results : No altered clinical symptoms including body weight, diarrhea, anorexia, death, and abnormal necropsy of major organs were observed in male or female rats. No drug-induced abnormalities in histopathological finding, hematological values, urinalysis, and blood biochemical values were found at any doses of Myelophil. Conclusion : Myelophil should be very safe when used in a clinical application with a wide therapeutic index.

  • PDF

ISFET Urea Sensor Using PVA-SbQ Polymer (PVA-SbQ 고분자 물질을 이용한 ISFET 尿素센서)

  • Sung Moon Choi;Chang-Soo Kim;Dong-Hyun Nam;Byung-Ki Sohn;Ui-Rak Kim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.4
    • /
    • pp.496-503
    • /
    • 1992
  • An ISFET urea sensor was fabricated by immobilizing the urease using photosensitive polymer, poly(vinyl alcohol)-SbQ on the H$^+$ sensing $Si_3$$N_4$ thin film of pH-ISFET. The sensor could determine the urea concentration in the range of 1∼50 mg/dl with fast response and good repeatability. For its application to clinical analysis, the interferences of the various materials which cause inhibition in urease catalytic reactions in blood was investigated. The results of the urea measurements in blood plasma using the ISFET urea sensor were compared with these of conventional spectrophotometric method.

  • PDF

Separation and Determination of Cadmium in Blood Serum by Solvent Extraction and Atomic Absorption Spectrophotometry (용매추출과 원자흡수분광법에 의한 혈청시료중 카드뮴의 분리 및 정량)

  • Lee, Seok Ki;Joung, Chang Ung
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.401-406
    • /
    • 1999
  • Trace amount of cadmium was quantitatively extracted with 1% Aliquat 336-MIBK from 0.2M KSCN and 0.01M-HCl. Test tubes with a screw cap stopper were used for extraction in place of conventional separating funnels and organic solvents used were less dense than water. In this analysis, 22 times concentration effect was achieved with higher selectivity without interference. The detection limit of cadmium was 0.7ppb, therefore trace cadmium was easily analyzed by this method. The proposed method was applied to the determination of cadmium in blood serum and extraction mechanism was elucidated.

  • PDF

The Neuroprotective Effects of Carnosine in Early Stage of Focal Ischemia Rodent Model

  • Park, Hui-Seung;Han, Kyung-Hoon;Shin, Jeoung-A;Park, Joo-Hyun;Song, Kwan-Young;Kim, Doh-Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.125-130
    • /
    • 2014
  • Objective : This study was conducted to elucidate neuroprotective effect of carnosine in early stage of stroke. Methods : Early stage of rodent stroke model and neuroblastoma chemical hypoxia model was established by middle cerebral artery occlusion and antimycin A. Neuroprotective effect of carnosine was investigated with 100, 250, and 500 mg of carnosine treatment. And antioxidant expression was analyzed by enzyme linked immunosorbent assay (ELISA) and western blot in brain and blood. Results : Intraperitoneal injection of 500 mg carnosine induced significant decrease of infarct volume and expansion of penumbra (p<0.05). The expression of superoxide dismutase (SOD) showed significant increase than in saline group in blood and brain (p<0.05). In the analysis of chemical hypoxia, carnosine induced increase of neuronal cell viability and decrease of reactive oxygen species (ROS) production. Conclusion : Carnosine has neuroprotective property which was related to antioxidant capacity in early stage of stroke. And, the oxidative stress should be considered one of major factor in early ischemic stroke.

Analysis of the Accuracy about Abdominal Ultrasonography and Clinical Chemical Test with Fatty Liver Patients on the Medical Examination (종합검진 후 지방간 환자의 복부 초음파 검사와 임상화학적 검사결과의 정확성 분석)

  • Kim, Young-Jae;Song, Jong-Nam;Kim, Min-Eui
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.183-189
    • /
    • 2012
  • Ultrasonography is one of the fields on the imaging studies within intra-abdominal organs. A blood test is a typical method of clinical chemical examination on the in vivo test of clinical symptoms. Fatty liver is performed simultaneously two kinds of diagnostics methods, intra-abdominal ultrasound and blood tests. At an implementing this, the standard of blood tests value was the TBIL, TC, AST, ALT, ALP, GGT, TG, HDL-C, GLU. In this study analyzing the accuracy of the two kinds of test, ultrasonography and blood test, on patients with fatty liver. From January to March 2012, patients 459 determined fatty liver within 1350, who received health examination simultaneously on the intra-abdominal ultrasonography and blood tests. Same result of ultrasonography and blood test's patients were 459 ie, 60.8%. and different result of those examinations was 280 ie, 39.2%. Consequently diagnostic accuracy was 60.8%. It presumably caused by differences in the diagnostic performance of ultrasound professionals(Radiologist or Radiological Technologist). In order to overcome this, ongoing educational and study will be needed.

Determination of Methylmercury in Biological Samples Using Dithizone Extraction Method Followed by Purge & Trap GC-MS

  • Lee, Jung-Sub;Ryu, Yoon-Jung;Park, Jae-Sung;Jeon, Sung-Hwan;Kim, Sam-Cwan;Kim, Young-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2293-2298
    • /
    • 2007
  • In this study, a dithizone extraction technique involving purge & trap GC-MS was developed for the determination of methylmercury in biological samples, especially blood and fish. After alkaline digestion, methylmercury in biological samples was extracted into dithizone and back-extracted into aqueous sulfide solution. The extracted methylmercury was converted to the volatile ethyl derivative, purged and trapped onto a solid-phase collection medium, and then introduced into the GC-MS system. The determined MDLs of the established method were 0.9 ng·g?1 for biological samples and its accuracy and precision were found to be 93% and 3.8%, respectively. The method was validated by analysis of CRMs such as SRM 966, BCR 463 and IAEA 407 and all analytical results were within certified ranges with average RSDs of less than 6%. The analytical results of field-sampled fish also showed that the method can be successfully used as an alternative for commonly used distillation method followed by GC-CVAFS detection.

Safety Evaluation of LB10522, a New Cephalosporin Antibiotic

  • Kim, Seong-Il;Raffi Mikaelian;Kwak, Jin-Hwan;Kim, In-Chull;Lee, Chang-Ho
    • Biomolecules & Therapeutics
    • /
    • v.3 no.4
    • /
    • pp.316-321
    • /
    • 1995
  • All the pharmacological studies of LB17522 described here were carried out with high doses (fifteen to sixty times of the therapeutic dose) to determine an indication of potential side effects in clinical use in terms of the acute clinical signs, cardiovascular and central nervous system. LB10522 does not produce any observable clinical signs except for the symptoms such as moist eye, skin rash, slight salivation, vomitting, and slightly reduced activity. The effects of LB10522 on the hemodynamics and cardiac function of anesthetized beagle dogs are as follows; heart rates and mean arterial blood pressure had a tendency to increase mildly, which is a normal finding in anesthetized dogs. All the animals except for one showed relatively stable respiratory rates throughout the observation period. Each animal treated with LB10522 showed slight increase in the left cardiac work and left ventricular stroke work which are mainly related to corresponding increases in cardiac output. Femoral blood flow were shown to be increased in some animals treated with LB10522. The epileptogenic activities of various cephalosporins were assessed by a direct intracerebral injection of appropriate concentration of test articles. The CD$_{50}$ values (nmol) obtained from the analysis of the dose-response data are as follows; 78.2, 175.3, 156.3, and 53.5 for cefazolin, cephaloridine, ceftazidime, and LB 10522, respectively. LB10522 seems to be equipotent with cefazolin or to be three times more potent than cephaloridine and ceftazidime in causing adverse CNS stimulation. Taken into consideration all the information obtained, LB10522 is not supposed to induce much changes in the functions examined in these studies in man at therapeutic doses.s.

  • PDF

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

Microfluidic Components and Bio-reactors for Miniaturized Bio-chip Applications

  • Euisik Yoon;Yun, Kwang-Seok
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.86-92
    • /
    • 2004
  • In this paper miniaturized disposable micro/nanofluidic components applicable to bio chip, chemical analyzer and biomedical monitoring system, such as blood analysis, micro dosing system and cell experiment, etc are reported. This system includes various microfluidic components including a micropump, micromixer, DNA purification chip and single-cell assay chip. For low voltage and low power operation, a surface tension-driven micropump is presented, as well as a micromixer, which was implemented using MEMS technology, for efficient liquid mixing is also introduced. As bio-reactors, DNA purification and single-cell assay devices, for the extraction of pure DNA from liquid mixture or blood and for cellular engineering or high-throughput screening, respectively, are presented.