• Title/Summary/Keyword: Blocking ratio

Search Result 216, Processing Time 0.027 seconds

Regional Contrast Enhancement for Local Dimming Backlight on Small-sized Mobile Display

  • Chung, Jin-Young;Kim, Ki-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.972-974
    • /
    • 2009
  • This paper presents smart regional contrast enhancement technique of partitioned image for local dimming backlight on small-sized mobile display to reach two goals. One is to save the power consumption, and the other to improve contrast ratio of display image. Recently new advanced method is proposed, named local dimming method, that backlight LED is positioned on backside of the display panel. So it is important to partition an image by sub blocks and then post-processing independantly. This means regional contrast enhancement. After partitioning, we compare the mean luminance(Y) value of each sub-block image with the one of original whole image. If some blocks have the mean value lower than the one of whole image, they are processed with the proposed method and others are bypassed. Simultaneously the information of the processed blocks are transferred to BLC(Backlight LED Controller). And then the supply current of each backlight LED is reduced to realize the contrast ratio enhancement and at the same time to power consumption reduction. In addition, we verify this proposed method is free from blocking artifacts.

  • PDF

Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions (무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.338-348
    • /
    • 2005
  • The permeate flux decline on microfiltration capillary membrane operation was investigated with inorganic colloidal solutions. The permeate flux of the alumina solution is two times higher in average than that of the bentonite solution. The flux decline with increase in operation time was less in the alumina solution than in the bentonite solution. The rate of initial flux decline until 10 min was higher on the bentonite solution over the alumina solution. The decline in permeate flux was due to both the cake formation and the pore blocking. The latter effect was higher in the operation of the bentonite solution. In comparing the ratio of each fouling component to the total fouling fur the $1.0\;kg_f/cm^2$ TMP condition, complete blocking was $9.35\%$, standard blocking was about $6.82\%$ and cake filtration was $83.83\%$, respectively. With the increase in cross flow velocity, the permeate flux increased by $6.0\%$ for the alumina solution and by 14.0 for the bentonite solution. With the increase in average pore size fromm $0.24\;{\mu}m\;to\;0.34\;{\mu}m$, the permeate flux increases 1.61 times for the alumina solution and 1.76 times far the bentonite solution.

A Novel Fabrication Method of the High-Aspect-Ratio Nano Structure (HAR-Nano Structure) Using a Nano X-Ray Shadow Mask (나노 X-선 쉐도우 마스크를 이용한 고폭비의 나노 구조물 제작)

  • Kim Jong-Hyun;Lee Seung-S.;Kim Yong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.10 s.253
    • /
    • pp.1314-1319
    • /
    • 2006
  • This paper describes the novel fabrication method of the high-aspect-ratio nano structure which is impossible by conventional method using a shadow mask and a Deep X-ray Lithography (DXRL). The shadow mask with $1{\mu}m-sized$ apertures is fabricated on the silicon membrane using a conventional UV-lithography. The size of aperture is reduced to 200nm by accumulated low stress silicon nitride using a LPCVD (low pressure chemical vapor deposition) process. The X-ray mask is fabricated by depositing absorber layer (Au, $3{\mu}m$) on the back side of nano shadow mask. The thickness of an absorber layer must deposit dozens micrometers to obtain contrast more than 100 for a conventional DXRL process. The thickness of $3{\mu}m-absorber$ layer can get sufficient contrast using a central beam stop method, blocking high energy X-rays. The nano circle and nano line, 200nm in diameter in width, respectively, were demonstrated 700nm in height with a negative photoresist of SU-8.

Effect of solids retention time on membrane fouling in membrane bioreactors at a constant mixed liquor suspended solids concentration

  • Hao, L.;Liss, S.N.;Liao, B.Q.
    • Membrane and Water Treatment
    • /
    • v.8 no.4
    • /
    • pp.337-353
    • /
    • 2017
  • Membrane fouling at different solids retention times (SRT) (7, 12 and 20 days) was studied under well-controlled conditions in a laboratory-scale aerobic submerged membrane bioreactor under constant biomass concentration using a synthetic high strength wastewater. An increase in SRT was found to improve membrane performance and this correlated to changes in the total production of bound extracellular polymeric substances (EPS), and the composition and properties of bound EPS using X-ray photoelectron spectroscopy (XPS) and Fourier transform-infrared spectroscopy (FTIR) and floc sizes. A larger amount of total bound EPS was found at the lowest SRT (7 days) tested but the ratio of proteins (PN) to carbohydrates (CH) in bound EPS increased with an increase in SRT. Similarly, the quantity of soluble microbial products (SMP) decreased with an increase in SRT and the SMP PN/CH ratio increased with an increase in SRT. SMP concentrations positively correlated to the percentage of membrane pore blocking resistance. The quantity of total bound EPS and total SMP positively corresponded to the membrane fouling rate, while the PN/CH ratio in the bound EPS and SMP negatively correlated to the membrane fouling rate. The results show that both the quantity and composition of bound EPS and SMP and floc sizes are important in controlling membrane fouling.

A study on the development of the fin-tube heat exchanger pollution ratio evaluation algorithm using Image Processing and Affine Transformation (영상처리 및 어파인변환을 이용한 핀튜브 열교환기 오염율 평가 알고리즘 개발에 관한 연구)

  • Park, Sungmin;Jung, Myungin;Whang, Kwangil;Cho, Gyeongrae
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • Among the various factors that cause the performance decrease of heat exchangers used in many industries, flow path blocking is one of the important and serious factor. In order to solve this problem, proper maintenance and management of the heat exchanger is important and emphasized. In this study, we developed and algorithm that can quantitatively determine and diagnose the normal and blocked areas of fin-tube heat exchanger using pattern analysis, Gaussian Edge Detection, Image Processing and Affine Transformation techniques. The developed algorithms was applied to the actual heat exchanger and the performance was evaluated by comparing with the manual results. From these results, it was proved that the developed algorithm is effective in evaluating the pollution ratio of the fin-tube heat exchanger.

Clinical and Radiological Outcomes of 'Blocking Kirschner Wire Technique' in Displaced Intra-Articular Calcaneal Fractures via the Extended Sinus Tarsi Approach (전위된 관절 내 종골 골절에서 확장된 족근동 접근법을 통한 Kirschner Wire 강선 지지대 고정술의 임상 및 영상학적 결과)

  • Lee, Jeong-Kil;Kang, Chan;Kim, Sang-Bum;Lee, Gi-Soo;Hwang, Jung-Mo;An, Byung-Kuk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.224-233
    • /
    • 2021
  • Purpose: The purpose of this study was to retrospectively evaluate the effect of 'Blocking Kirschner Wire (K-Wire) Technique', which has been developed to reduce protrusion of the lateral wall, in maintaining the level of reduction through clinical and radiological outcomes. Materials and Methods: Twenty-two patients with displaced intra-articular calcaneal fractures who used the blocking K-wire to maintain reduction (group A) and 44 patients that did not use blocking K-wire and were paired in 1:2 ratio with those Group A patients (group B), between January 2015 and December 2017 were enrolled in the study. All surgical procedures were performed via the extended sinus tarsi approach, and internal fixation using cannulated screws, Steinmann pins and K-wires was performed. American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot scale and postoperative recovery of exercise ability were compared for postoperative clinical outcomes. The radiological results were compared the Böhler angle, Gissane angle, calcaneal height and width, step off of posterior calcaneal joint, and the degree of protrusion of the lateral wall. Moreover, postoperative complications in both groups were compared. Results: There were no significant differences in the clinical outcomes of the two groups (p=0.924, p=0.961). The amount of Böhler angle, Gissane angle, calcaneal height and width, and step off of posterior calcaneal joint from the radiological results was not significantly different between the two groups (p=0.170, p=0.441, p=0.230, p=0.266, and p=0.400). However, the degree of protrusion of the lateral wall was 1.78 mm and 4.95 mm in group A and group B, respectively, and the difference between the two groups was significant (p=0.017). Although sural nerve entrapment and painful exostosis were more frequent in group B, they were occurred in a non-significant manner (p=0.293, p=0.655). Conclusion: Most of the clinical and radiological results as well as the complications were not significantly different between the two groups. However, the degree of protrusion of the calcaneus lateral wall in group A was promising. The 'Blocking K-Wires Technique' established by the authors may be an effective surgical option for maintaining the reduction of the lateral wall protrusion in displaced intraarticular calcaneal fractures.

Analysis of GPS signal environment at DGNSS stations (DGNSS 기준국 관측환경 분석)

  • Sohn, Dong-Hyo;Park, Kwan-Dong;Won, Ji-Hye;Choi, Yong-Kwon;Kee, Chang-Don
    • Journal of Navigation and Port Research
    • /
    • v.35 no.8
    • /
    • pp.625-629
    • /
    • 2011
  • In this study, we analyzed the signal environment of 17 DGNSS stations operated by DGPS Central Office through TEQC quality checking, visibility analysis and site visits. With TEQC, we produced times series of four indices of TEQC quality checking: observation ratio, L1 pseudorange multipath, L2 pseudorange multipath, and the frequency of cycle slip events. From visibility analysis, the directions where missing observations are happening were identified and the result was verified through onsite investigation. Without considering TEQC indices at the six sites(Palmido, Eochungdo, Geomundo, Pyeongchang, Seongju, and Chungju), the average TEQC indices were: 98% observation ratio, 0.19m of L1 pseudorange multipath, 0.71m of L2 pseudorange multipath, and 1.3 cycle slips per 1000 observations. The observation ratios at Palmido and Eochungdo were low. It was found that receiver settings were incorrect so that they could track the P2 signal of GPS satellites with L2C capability. No signal-blocking obstacles were found around the Geomundo station except the lighthouse. Thus, we guess that the poor TEQC indices at the site are believed to be caused by problems in the GPS hardware or cables. The low observation ratio at Pyeongchang is being caused by the surrounding hills blocking the satellite view from the south to the northwest directions. Even though all of four TEQC indices were bad at Seongju and Chungju stations, we found that the signal reception environment at the two sites is in good condition. We think that the quality indices got poor probably because of malfunctioning equipment. So, further investigation is needed for the Seongju and Chungju sites.

Enhancement of Nitrendipine Bioavailability in Rats by its Solid Dispersion with $Hydroxypropyl-{\beta}-Cyclodextrin$ after Oral Administration (흰쥐에 경구 투여시 히드록시프로필-베타-시클로덱스트린과 니트렌디핀 고체분산에 의한 생체이용률 증가)

  • Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.27 no.4
    • /
    • pp.295-301
    • /
    • 1997
  • Nitrendipine, a slightly soluble calcium channel blocking agent forms a solid dispersion system with $hydroxypropyl-{\beta}-cyclodextrin$, which exhibits better dissolution characteristics than the uncomplexed drug. The dissolution rate of nitrendipine was markedly increased in solid dispersion system in pharmacopeial disintegration media at pH 1.2 and pH 6.8. Four different dosage forms of nitrendipine were administered to rats: (a) nitrendipine in the solution of PEG 400; (b) nitrendipine solid dispersion system with $hydroxypropyl-{\beta}-cyclodextrin$ in a molar ratio of 1:2 by solvent evaporation method and administered in capsule form; (c) physical mixture of nitrendipine with $hydroxypropyl-{\beta}-cyclodextrin$ in a molar ratio of 1:2 and administered in capsule form; (d) nitrendipine alone administered in capsule form. Relative bioavailability after the oral administration of various dosage forms to rats with a dose of 10 mg/kg equivalent to nitrendipine was compared with that of nitrendipine in the solution of PEG 400. The AUC of solid dispersion was significantly bigger than that of nitrendipine powder. $T_{max}$ of solid dispersion was significantly shorter and $C_{max}$ was higher than that of nitrendipine powder. These results indicate that the bioavailability of nitrendipine could be improved markedly by inclusion complexation. An interesting correlation also appears to exist between the in vitro dissolution data and the area under the plasma concentration-time curves.

  • PDF

Efficiency of TLDs with bottom-mounted baffles in suppression of structural responses when subjected to harmonic excitations

  • Shad, Hossein;Adnan, Azlan;Behbahani, Hamid Pesaran;Vafaei, Mohammadreza
    • Structural Engineering and Mechanics
    • /
    • v.60 no.1
    • /
    • pp.131-148
    • /
    • 2016
  • Tuned Liquid Dampers (TLDs) provide low damping when it comes to deep water condition, and that not all water depth is mobilized in energy dissipation. This research focussed on a method to improve the efficiency of TLDs with deep water condition. Several bottom-mounted baffles were installed inside a TLD and the dynamic characteristics of modified TLDs together with their effect on the vibration control of a SDOF structure were studied experimentally. A series of free vibration and harmonic forced vibration tests were carried out. The controlling parameter in the conducted tests was the Vertical Blocking Ratio (VBR) of baffles. Results indicated that increase in VBR decreases the natural frequency of TLD and increases its damping ratio. It was found that the VBR range of 10% to 30% reduced response of the structure significantly. The modified TLD with the VBR of 30% showed the best performance when reduction in structural responses under harmonic excitations were compared.

A Wavelet CODEC that is with JPEG (JPEG와 호환 가능한 Wavelet CODEC)

  • Kim, Yong-Gyu;Kim, Dok-Gyu;Jo, Seok-Pal
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.1
    • /
    • pp.43-53
    • /
    • 2001
  • WT(Wavelet Transform) is used to avoid blocking effect that is the disadvantage of JPEG using DCT(Discrete Cosine Transform). Because the proposed coding scheme is the same as JPEG, the proposed algorithm is compatible with that of JPEG. To achieve the goal, WT'ed image is reconstructed into 8$\times$8 coding block. Each coding block is quantized with the proposed weighting matrix that is derived from human visual characteristic and error analysis in WT'ed domain. By experiments, the proposed algorithm is superior to JPEG, in terms of PSNR(Peak Signal to Noise Ratio) and WMSE(Weighted Mean Square Error).

  • PDF