• 제목/요약/키워드: Blockage analysis

검색결과 143건 처리시간 0.033초

차폐유형과 차폐도를 달리한 패럴랙스(Parallax) 공간의 시각 선호도 (An Analysis of the Visual Preference on Parallax Space by Blockage Pattern and Ratio)

  • 노재현
    • 한국조경학회지
    • /
    • 제35권2호통권121호
    • /
    • pp.55-63
    • /
    • 2007
  • The purpose of this study is to create a planting design for progressive realization. For this, visual preferences as measured via questionnaire were evaluated by the Scenic Beauty Estimation(SBE) and paired comparison methods. The results can be summarized as follows. Through photo observation, the average visual blockage ratio was 38% and the range of degree of the visual blockage ratio was $30{\sim}50%$. The sketch simulation and filtered pattern received the highest preference score and fumed out to be the most practical pattern out of all the patterns evaluated. Also, in the sketch simulation, the high preference values were observed for a distance of 9 to 12m from the view point to the blockage tree with a D/H ratio of 2. The preference score significantly decreased with the increase of the visual blockage ratio having a turning point at $30{\sim}35%$ of the visual blockage ratio, even though the distance parameters were more important than the visual blockage ratio in the scores. An outstanding view must be handled properly to be preserved or accentuated. Framed, open, enclosed, screened or filtered pattern views should be completely revealed only from their best vantage point, not given away at first glimpse. It this sense, parallax spatial beauty with trees could be improved through the visual aspects of plan arrangements and seems to be an effective design technique for landscape planning and planting design.

Subsea X-mas Tree에서의 Blockage 처리 실패에 대한 위험도 저감 방안 분석 (Analysis of Risk Control Options for Blockage Treatment)

  • 유원우;박민선;양영순
    • 한국해양공학회지
    • /
    • 제27권2호
    • /
    • pp.47-52
    • /
    • 2013
  • A subsea chemical injection system treats blockage problems in a subsea production system. It is important to treat problems quickly, because production delays cause fatal profit losses in a subsea production system. Therefore, the subsea industry requires a relatively higher reliability level for a production system compared to other industries. In this study, a subsea chemical injection system (linked to a control system) to inject chemicals into a subsea X-mas tree was analyzed. By using FSA (Formal Safety Assessment), the risk factors were defined and a quantitative risk analysis utilizing FTA (Fault Tree Analysis) and ETA (Event Tree Analysis) was performed. As a result, the effectiveness of a risk reduction option was evaluated.

Wire-wrap Models for Subchannel Blockage Analysis

  • Ha K.S.;Jeong H.Y.;Chang W.P.;Kwon Y.M.;Lee Y.B.
    • Nuclear Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.165-174
    • /
    • 2004
  • The distributed resistance model has been recently implemented into the MATRA-LMR code in order to improve its prediction capability over the wire-wrap model for a flow blockage analysis in the LMR. The code capability has been investigated using experimental data observed in the FFM (Fuel Failure Mock-up)-2A and 5B for two typical flow conditions in a blocked channel. The predicted results by the MATRA-LMR with a distributed resistance model agreed well with the experimental data for wire-wrapped subchannels. However, it is suggested that the parameter n in the distributed resistance model needs to be calibrated accurately for a reasonable prediction of the temperature field under a low flow condition. Finally, the analyses of a blockage for the assembly of the KALIMER design are performed. Satisfactory results by the MATRA-LMR code were obtained through and rerified a comparison with results of the SABRE code.

CFD investigation of a JAEA 7-pin fuel assembly experiment with local blockage for SFR

  • Jeong, Jae-Ho;Song, Min-Seop
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3207-3216
    • /
    • 2021
  • Three-dimensional structures of a vortical flow field and heat transfer characteristics in a partially blocked 7-pin fuel assembly mock-up of sodium-cooled fast reactor have been investigated through a numerical analysis using a commercial computational fluid dynamics code, ANSYS CFX. The simulation with the SST turbulence model agrees well with the experimental data of outlet and cladding wall temperatures. From the analysis on the limiting streamline at the wall, multi-scale vortexes developed in axial direction were found around the blockage. The vortex core has a high cladding wall temperature, and the attachment line has a low cladding wall temperature. The small-scale vortex structures significantly enhance the convective heat transfer because it increases the turbulent mixing and the turbulence kinetic energy. The large-scale vortex structures supply thermal energy near the heated cladding wall surface. It is expected that control of the vortex structures in the fuel assembly plays a significant role in the convective heat transfer enhancement. Furthermore, the blockage plate and grid spacer increase the pressure drop to about 36% compared to the bare case.

볼 여과기 스크린 모듈의 단면 폐쇄효과에 관한 수치해석적 연구 (Numerical Analysis of Ball Strainer Screen Module Blockage Effects)

  • 정경철;이해수;이치우
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.83-89
    • /
    • 2015
  • A ball strainer screen module, which is used for a condenser tube cleaning system, is a critical mechanical component for maintaining condenser cleanliness. Despite of this importance, not many research have been focused on this module because of its relatively low usage. Employing CFD, this study examines the implication of fluid velocity change and blockage ratio on the ball strainer screen velocity and the static pressure distribution. Through this study, the impact of blockage in the space between ball strainer screen modules is verified. Also, it is found that the ranges of non-dimensional velocity distribution and static pressure distribution decrease as blockage ratio becomes smaller.

원심압축기 임펠러의 Blockage와 Slip 특성에 관한 수치연구 (Numerical Study on Blockage and Slip Characteristics of Centrifugal Compressor Impellers)

  • 오종식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.236-244
    • /
    • 2000
  • As the second part of the author's study, the aerodynamic blockage and the slip factor of 8 centrifugal compressor impellers are investigated, when the flow rate is changed from numerical stall to choke, using three-dimensional Navier-Stokes analysis results. Based on all the exit blockage distributions, an improved model equation with two adjusting coefficients is developed for the use in design processes with the agile engineering purpose. A popular expression of constant slip factors, the Wiesner's equation, cannot be applied in design processes when more accurate prediction is strongly required at design and off-design points. Slip factor variation is found to be also influenced by the blade loadings at midspan. When the flow rate is changed, a pattern of the slip factor variations is assumed to be a simple form which can be explained using midspan blade loading distributions.

  • PDF

삼차원 유동해석을 통한 침전조의 침전효율 예측 및 형상설계 (Shape Design and Prediction of Efficiency of Sedimentation Bed using Three-Dimensional Flow Analysis)

  • 최상철;김홍민;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.95-98
    • /
    • 2002
  • Three-dimensional flow analyses for two different ratios of radius to height of sedimentation bed are implemented to evaluate the effect of blockage ratio of center feed wall and angle of distributor on sedimentation efficiency, and to find the optimal value of those parameters. Sedimentation efficiencies for three different shapes are compared with and without rotation speed. And then, five different combinations of blockage ratio of center feed wall and angle of distributor are compared It reveals that the effect of blockage ratio of center fled wall and angle of distributor is considerable to sedimentation efficiency while rotation effect can be neglected and $0.55 and 33^{\circ}$for blockage ratio of center food wall and angle of distributor, respectively, ive the best sedimentation efficiency.

  • PDF

옵셋 스트립 휜의 막음비에 따른 열 및 유동 분석 (Thermo-Flow Analysis of Offset-Strip Fins according to Blockage Ratio)

  • 김민수;유승환;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1084-1089
    • /
    • 2009
  • A numerical study of thermo-flow characteristics is presented to determine correlations of pressure drop and heat transfer for offset-strip fins. As a blockage ratio increased, previous correlations underestimate f values in laminar and turbulent regimes, and overestimate j values in laminar regime. Therefore, new correlations, which are applicable to fins with blockage ratios more than 15%, are presented.

  • PDF

제주시 해안일주도로의 경관보전을 위한 건축물의 입면차폐도 분석에 관한 연구 (A Study on the Analysis of the Elevation Blockage Ratio in the Conservation of the Coastal Landscape of Jeju)

  • 박철민;김성훈
    • 한국농촌건축학회논문집
    • /
    • 제6권2호
    • /
    • pp.31-42
    • /
    • 2004
  • Although the coastal area of Jeju has already been developed, it has high pressure and demands for development continually increasing due to the increase of tourism and leisure activities. Therefore, the purpose of this study is to present objective guidance for the planning of the buildings on the seaside road with a view which have the largest impact on coastal landscape in order to enhance its visual quality. The results of this study are as follows : 1) It is chief element to make guidance for the use and planning of buildings in the conservation of the coastal landscape. 2) The D/H ratios which immediately influence an angle of elevation are different one another for the whole street. To ensure a sense of openness for the landscape, it is needed to maintain under $27^{\circ}$ angle of elevation, which demands 1~3 D/H ratio. 3) It is important to make 2.4 visual blockage ratio for whole street, but the actual condition is 4.48 ratio on average. To bring down the visual blockage ratio, the W/D ratio needs to be regulated. 4) Various techniques are also needed for lively building styles going with coastal landscape.

  • PDF