• 제목/요약/키워드: Block-filling

검색결과 74건 처리시간 0.031초

A study on the seismic performance of reinforced concrete frames with dry stack masonry wall using concrete block

  • Joong-Won Lee;Kwang-Ho Choi
    • Earthquakes and Structures
    • /
    • 제24권3호
    • /
    • pp.205-215
    • /
    • 2023
  • Currently, many studies are underway at home and abroad on the seismic performance evaluation and dry construction method of the masonry structure. In this study, a dry stack masonry wall system without mortar using concrete blocks is proposed, and investigate the seismic performance of dry filling wall frames through experimental studies. First, two types of standard blocks and key blocks were designed to assemble dry walls of concrete blocks. And then, three types of experiments were manufactured, including pure frame, 1/2 height filling wall frame, and full height filling wall frame, and cyclic load experiments in horizontal direction were performed to analyze crack patterns, load displacement history, rebar deformation yield, effective stiffness change, displacement ductility, and energy dissipation capacity. According to the experimental results, the full height filling wall frame had the largest horizontal resistance against the earthquake load and showed a high energy dissipation capacity. However, the 1/2 height filling wall frame requires attention because the filling wall constrains the effective span of the column, limiting the horizontal displacement of the frame. In addition, the concrete block was firmly assembled in the vertical direction of the wall as the horizontal movement between the concrete blocks was allowed within installation margin, and there was no dropping of the assembled concrete block.

사출금형에서 균형충전을 위한 새로운 러너시스템 멜트버퍼 (A New Runner System Melt-Buffer for Filling Balance in Injection Mold)

  • 정영득;장민규
    • 소성∙가공
    • /
    • 제18권2호
    • /
    • pp.122-127
    • /
    • 2009
  • The injection mold with multi-cavity is essential for mass production of plastic products. Multi-cavity molds are designed to geometrically balanced runner system to uniformly fill to each cavity. However, despite geometrical balanced runner system, filling imbalances between cavity to cavity have always been observed in injection molding. To solve these problems, many studies such as Melt Flipper, RC Pin, and others have been presented. The results of these studies have been an effect on filling balances in multi-cavity molds. But, those have had a limitation that additional insert parts must have existed in the mold. In this study, a new runner system is suggested for filling balance between cavity to cavity using "Melt-Buffer" with simple change of runner shape. A series of simulation to confirm feasibility of Melt-Buffer's effects was conducted using injection molding CAE program. Also, a series of injection molding experiment was conducted using plastic materials such as ABS and PP. As results of this study, feasibilities of filling balances by Melt-Buffer were confirmed.

녹화용 다공질 식재 블럭의 개발 (Development in Planting Porous Block for Revegetation)

  • 안영희;최경영
    • 한국환경복원기술학회지
    • /
    • 제5권4호
    • /
    • pp.1-9
    • /
    • 2002
  • This study is carried out to make the environmentally affinitive porous planting block for revegetation and to make a effective program for greening plans. The summary is shown below. 1. In order to get stronger intensity and distribute proper porosity in the block for planting, the cements mixed with fine soil were used and the finer in soil grains gives the stronger in intensity of the cements. Use of the furnace slag cements instead of the portland cements showed relatively stronger in intensity of the block. The intensity of the block became stronger when the mixed ratio of the cements to soil is 5 : 1, but the pore space ratio was lower. The percolate pH of the portland cements after one month of treatment was 13.1 but the percolate pH of the furnace slag cements was shown lower. To mold proper porous planting blocks, the proper combination of additives such as the dehydrating agent, elastic agent and adhesives into the mixture of cements and soil gives better effectives. 2. After molding the porous planting blocks, it gave a better result when the grains of the filler made of peat moss, upland soil and compound fertilizer were smaller than 2 mm in size. Shaking of the filling materials also gave the better result, but it took more time and cost much more. Therefore, it was better when the filling materials were mixed with water first then flew down for stuffing. 3. It was necessary to cover with soil after seeding or planting on the porous planting blocks. The proper thickness of the soil to help root development and keep moisture is about 3~5 cm. 4. The plants for planting on the porous planting block were required stronger in the growth condition of their roots and their environmental adaptability. The average germination percentage and rate of Platycodon grandiflorum on the porous planting block were 88.8% and 85% accordingly and their rate is very uniform. The germination rates of Dianthus superbus var. longicalycinus and Taraxacum officinale were more than 50%. These grass species, Chelidonium majus var. asiaticum, Lysimachia mauritiana and Scabiosa mansenensis were the suggested biennial grasses in the planting area where exchanging of the seedling or nursery plants was not necessary because their germination rates were 59.3, 45.6 and 40.3% accordingly. Viola kapsanensis, Chrysanthemum sp., Taraxacum sp. and Iris ensata var. spontanea are the grass species that could be used by seeding for greening. However, the germination rate of Solidago virga-aurea var. asiatica, Aster scaber and Lythrum anceps were lower than 10%. The coverage ratio of Ixeris stolonifera is more than 80% after 60 days seeding and the root length of most of species are more than 10 cm except Iris ensata var. spontanea and Platycodon grandiflorum because their root developed thicker than other species.

하수슬러지를 이용한 Bio-block의 비점오염물질 제거 가능성 평가 (Evaluation of the Feasibility of Eliminating Non-point Source Pollution Using Waste Sewage Sludge Bio-blocks)

  • 한상무;김도형;정병곤
    • 한국물환경학회지
    • /
    • 제37권5호
    • /
    • pp.363-368
    • /
    • 2021
  • On the assessment results of the non-point source pollutant removability of bio-block using waste sewage sludge, at the reactor's initial operation stage, the removal efficiency of COD was slightly unstable. However, after the reactor was stabilized, the COD removal efficiency was higher in the reactor filled with bio-blocks compared to the reactor filled with broken stones. In terms of nitrogen and phosphorus, their removal efficiency was unstable at the initial stage of the reactor operation. This phenomenon was investigated through the bio-block elution experiments. Results indicated that nitrogen and phosphorus were eluted from the bio-blocks affecting their removal at the initial operation. Furthermore, based on elution tests conducted after the dry ashing of the waste sewage sludge, part of the nitrogen and phosphorus was eluted similar to the bio-block elution test results, although considerable amounts of nitrogen and phosphorus were reduced compared to the sludge cake. Prior to the use of the waste sewage sludge bio-blocks as a filter medium to remove non-point source pollutants, a stabilization period of 10 days was required. After the stabilization process, results showed similar characteristics as general aggregates. Moreover, to use the bio-block as a filter medium for the non-point pollutant removal, the filling ratio of 75% was the most suitable as it resulted in the highest nitrogen removal efficiency after the stabilization. The results of this study suggested that waste sewage sludge can be suitably recycled as a mixed raw material for the bio-blocks, with satisfactory application as a filter medium in artificial wetlands, stormwater runoff problems, stream water pollutants to eliminate non-point source pollutants.

Video Quality for DTV Essential Hidden Area Utilization

  • Han, Chan-Ho
    • Journal of Multimedia Information System
    • /
    • 제4권1호
    • /
    • pp.19-26
    • /
    • 2017
  • The compression of video for both full HD and UHD requires the inclusion of extra vertical lines to every video frame, named as the DTV essential hidden area (DEHA), for the effective functioning of the MPEG-2/4/H encoder, stream, and decoder. However, while the encoding/decoding process is dependent on the DEHA, the DEHA is conventionally viewed as a redundancy in terms of channel utilization or storage efficiency. This paper proposes a block mode DEHA method to more effectively utilize the DEHA. Partitioning video block images and then evenly filling the representative DEHA macroblocks with the average DC coefficient of the active video macroblock can minimize the amount of DEHA data entering the compressed video stream. Theoretically, this process results in smaller DEHA data entering the video stream. Experimental testing of the proposed block mode DEHA method revealed a slight improvement in the quality of the active video. Outside of this technological improvement to video quality, the attractiveness of the proposed DEHA method is also heightened by the ease that it can be implemented with existing video encoders.

산모에서 요부 경막외 차단후 발생한 편측 호너 증후군과 상지마비 -증례 보고- (Unilateral Horner's Syndrome and Upper Extremity Paralysis following Lumbar Epidural Block in a Obstetric Patient)

  • 장연;조은정;김정태;박수석;이재희
    • The Korean Journal of Pain
    • /
    • 제10권2호
    • /
    • pp.285-290
    • /
    • 1997
  • Horner's syndrome is a well-recognized complication of regional analgesia of neck and shoulder region, and not often a complication of lumbar or low thoracic epidural block. Recently we experienced right Horner's syndrome accompanying paralysis of right upper extremity following lumbar epidural block in for an obstetric patient. Epidurography and MRI was performed to clarify the cause of unilateral high epidural block and cervical sympathetic block. Radiologic study demonstrated a loop formation of the epidural catheter and tip of catheter was located in right anterior epidural spaced(L1-2). The initial epidurogram revealed unilateral spreading of dye in the cervical region in right epidural space. A second epidurogram, 10 minutes following, showed dye filling in left epidural space, however spread of dye in left side was limited to lumbar and low thoracic region. We concluded the most probable cause of this unilateral high epidural block was due to misplacement of the catheter into the anterior epidural space.

  • PDF

Spreader의 종류와 Accessory cone의 접합성에 따른 근단폐쇄성에 관한 실험적 연구 (EVALUATION OF APICAL SEAL ACCORDING TO TYPES OF SPREADER AND COMPATIBILITY OF ACCESSORY CONE USED IN LATERAL CONDENSATION METHOD WITHOUT SEALER)

  • 안영미;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.461-472
    • /
    • 1994
  • The purpose of this study was to evaluate the sealing ability according to types of spreader and compatibility of accessory cone used in lateral condensation method. 120 plastic blocks with canal preformed were instrumented with K-,H-files and Gates-Gllidden bur. Shaped plastic blocks were divided into six experimental groups according to spreader and accessory cone used in lateral condensation. Then they were obturated by lateral condensation method without -sealer. Six experimental groups were as follows: Group 1 : Filling with #30 spreader & #25 gutta-percha cone Group 2 : Filling with #30 spreader & Fine accessory cone Group 3 : Filling with #3 spreader & #25 gutta-percha cone Group 4 : Filling with #3 spreader & Fine accessory cone Group 5 : Filling with #20,#30 spreader & #25 gutta-percha cone Group 6 : Filling with #2, #3 spreader & Fine accessory cone All the blocks were stored in 100% humidor at room temperature for 2 days. Each block was placed in centrifuged for 20 minutes at 3,000 rpm. Apical leakage was mesured from the apical foramen to the most coronal level of- dye leakage in millimeter under a stereoscope. The data were analysed by ANOVA. The obtained results were as follows; 1. In groups using two spreaders(Group 5,6), the linear leakage was less than one spreader using groups(Group 1-4). 2. Tn groups using two spreaders(Group 5,6), there was no significant difference in linear leakage between standardized -spreader group and non standardized group (p>0.01). 3. When one spreader was used(Group 1-4), standardized-spreader groups showed less linear leakage than nonstandardized spreader groups(P<0.01). 4. In case of using same spreader(Groupl,2 & Group 3,4), there was no significant difference in linear leakage according to accessory cone type. 5. It needs to use one more spreaders to increase apical sealability.

  • PDF

사이질방광염에서 요부 교감신경차단술의 효과 -증례 보고- (The Effect of Lumbar Sympathetic Block in Interstitial Cystitis -A case report-)

  • 정재윤;정지원;김용익
    • The Korean Journal of Pain
    • /
    • 제18권2호
    • /
    • pp.208-209
    • /
    • 2005
  • Interstitial cystitis is an extremely painful and distressing condition, characterized by severe suprapubic pain, which increases with bladder filling and is relieved by voiding. The daily frequency of micturition may approach 100 times, but no incontinence is observed. The symptoms persist throughout the night, which consequently affects sleep. The etiology of this condition is still unknown, but includes infection, autoimmune response, allergic reaction, neurogenic inflammation, epithelial dysfunction and inherited susceptibility. Herein, a case of interstitial cystitis, with severe symptoms, which was successfully treated with lumbar sympathetic block, is reported.

한국형발사체 발사대시스템 산화제공급설비 상세설계 (Critical Design Result of Liquid Oxygen Filling System for Korea Space Launch Vehicle-II Launch Complex)

  • 서만수;고민호;선정운;서현민;이재준;강선일
    • 한국추진공학회지
    • /
    • 제21권2호
    • /
    • pp.102-110
    • /
    • 2017
  • 발사대시스템의 산화제공급계(Liquid Oxygen Filling System)는 발사체의 추진제(Propellant) 중 연료의 연소를 위한 산화제(Oxidizer)로 사용되는 액체산소(Liquid Oxygen)를 저장하고, 발사체 요구조건에 맞게 공급하는 하는 설비이다. 본 논문에서는 한국형발사체(KSLV-II) 발사대시스템 상세설계(Critical Design, 2015년 8월에서 2016년 4월, 8개월) 동안 수행된 한국형발사체 발사대시스템 추진제 공급설비의 산화제공급계 설계 내용을 주요 설비 구성에 대하여 구조적 관점으로 소개한다.