• Title/Summary/Keyword: Block scan

Search Result 103, Processing Time 0.024 seconds

Radiotherapy Treatment Planning with Computed Tomography in Malignant Tumors of the Chest-Comparison of various techniques (흉부악성종양(胸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관한 연구(硏究))

  • Lee, Joo Hyuk;Koh, Kyoung Hwan;Ha, Sung Whan;Han, Man Chung
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.55-60
    • /
    • 1983
  • To evaluate the usefulness of computed tomography (CT) in radiotherapy treatment planning in malignant tumors of thoracic cage, the computer generated dose distributions were compared between plans based on conventional studies and those based on CT scan. 22 cases of thoracic malignancies, 15 lung cancers and 7 esophageal cancers, diagnosed and treated in Department of Therapeutic Radiology of Seoul National University Hospital from September, 1982 to April, 1983, were analyzed. In lung cancers, dose distribution in plans using AP, PA parallel opposing ports with posterior spinal cord block and in plans using box technique both based on conventional studies were compared with dose distribution using AP, PA and two oblique ports based on CT scan. In esophageal cancers, dose distribution in plans based on conventional studies and those based on CT scans, both using 3 port technique were compared. The results are as follows: 1. Parallel opposing field technique were inadequate in all cases of lung cancers, as portion of primary tumor in 13 of 15 cases and portion of mediastinum in all were out of high dose volume. 2. Box technique was inadequate in 5 of 15 lung cancers as portion of primary tumor was not covered and in every case the irradiated normal lung volume was quite large. 3. Plans based on CT scan were superior to those based on conventional studies as tumor was demarcated better with CT and so complete coverage of tumor and preservation of more normal lung volume could be made. 4. In 1 case of lung cancer, tumor localization was nearly impossible with conventional studies, but after CT scan tumor was more clearly defined and localized. 5. In 1 of 7 esophageal cancers, the radiation volume should be increased for marginal coverage after CT scan. 6. Depth dose correction for tissue inhomogeneity is possible with CT, and exact tumor dose can be calculated. As a result radiotherapy treatment planning based on CT scan has a pteat advantage over that based on conventional studies.

  • PDF

Automatic Hand Measurement System from 2D Hand Image for Customized Glove Production

  • Han, Hyun Sook;Park, Chang Kyu
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.468-476
    • /
    • 2016
  • Recent advancements in optics technology enable us to realize fast scans of hands using two-dimensional (2D) image scanners. In this paper, we propose an automatic hand measurement system using 2D image scanners for customized glove production. To develop the automatic hand measurement system, firstly hand scanning devices has been constructed. The devices are designed to block external lights and have user interface to guide hand posture during scanning. After hands are scanned, hand contour is extracted using binary image processing, noise elimination and outline tracing. And then, 19 hand landmarks are automatically detected using an automatic hand landmark detection algorithm based on geometric feature analysis. Then, automatic hand measurement program is executed based on the automatically extracted landmarks and measurement algorithms. The automatic hand measurement algorithms have been developed for 18 hand measurements required for custom-made glove pattern making. The program has been coded using the C++ programming language. We have implemented experiments to demonstrate the validity of the system using 11 subjects (8 males, 3 females) by comparing automatic 2D scan measurements with manual measurements. The result shows that the automatic 2D scan measurements are acceptable in the customized glove making industry. Our evaluation results confirm its effectiveness and robustness.

A New Driving Method for Gray-scale Expression in an AC Plasma Display Panel (교류형 플라즈마 디스플레이 패널에서 계조표현을 위한 새로운 구동방식)

  • 김재성;황현태;서정현;이석현
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.407-414
    • /
    • 2004
  • In this paper, a new gray scale expression method that divides the scan lines into multiple blocks is suggested. The proposed method can drive 16 sub-fields per 1 TV field in the panel with XGA ($1366{\times}768$) resolution. The on and off states of even subfields depend on the condition of odd subfields. The write address mode is used in the odd subfields, while the erase address mode is used in the even subfields. Because the ramp reset pulse is applied every 2 sub-fields, both the contrast ratio and the dynamic voltage margin are sufficiently obtained in comparison with previous AWD (Address While Display) methods. In realizing 16 subfields, shortening the scan time in the erase address period was important. The X bias voltage in the erase address period affected the minimum address voltage but did not the delay time of the address discharge. The delay time of the address discharge was affected by the address voltage and the time interval between the last sustain discharge and the scanning time. We also evaluated the dynamic false contour. New method shows an improved image quality in horizontal moving, but discontinuous lines were observed at the boundaries of each block in vertical moving

A Study on the Defect Classification and Evaluation in Weld Zone of Austenitic Stainless Steel 304 Using Neural Network (신경회로망을 이용한 오스테나이트계 스테인리스강 304 용접부의 결함 분류 및 평가에 관한 연구)

  • Lee, Won;Yoon, In-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.7
    • /
    • pp.149-159
    • /
    • 1998
  • The importance of soundness and safety evaluation in weld zone using by the ultrasonic wave has been recently increased rapidly because of the collapses of huge structures and safety accidents. Especially, the ultrasonic method that has been often used for a major non-destructive testing(NDT) technique in many engineering fields plays an important role as a volume test method. Hence, the defecting any defects of weld Bone in austenitic stainless steel type 304 using by ultrasonic wave and neural network is explored in this paper. In order to detect defects, a distance amplitude curve on standard scan sensitivity and preliminary scan sensitivity represented of the relation between ultrasonic probe, instrument, and materials was drawn based on a quantitative standard. Also, a total of 93% of defect types by testing 30 defect patterns after organizing neural network system, which is learned with an accuracy of 99%, based on ultrasonic evaluation is distinguished in order to classify defects such as holes or notches in experimental results. Thus, the proposed ultrasonic wave and neural network is useful for defect detection and Ultrasonic Non-Destructive Evaluation(UNDE) of weld zone in austenitic stainless steel 304.

  • PDF

A study of Developing Torso Master Pattern Using 3D body Measurement Data - Focusing on Women in their thirties proper Body Types - (3차원 인체형상자료를 활용한 토르소 마스터패턴 개발 - 30대 바른 체형 여성을 대상으로 -)

  • Shin, Ju-Young Annie;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.17 no.3
    • /
    • pp.447-461
    • /
    • 2015
  • The purpose of this study is to develop a torso pattern that is highly representative for the proper body shape of women in their thirties. Size data of the women with age of 30 through 39 from the database of Size Korea 2004 were used for the study. In order to develop a master pattern which will be used as the benchmark for grading of research group, 4 existing torso block drafting methods were compared based on the data gathered and the block with the highest evaluation score was utilized as a reference point. For the analysis, data was divided into four types, only the data of 138 subjects which were evaluated at least by four or more experts as valid were used for the study. The major results can be summarized as follow. The women of bust girth of 91cm and height of 160cm which was turned out to be representative type of research group were used as standard measurement for the purpose of reflecting not only curve length of the 3D analysis measurement but also the difference between front and back thickness to the pattern. Dart locations were set based on front and back torso ease, shoulder area revisions, front sagging length 1.5cm and cross section crevice length analysis. According to the experts' appearance evaluation of the pattern was found to be better than the control pattern which was regarded as the best among 4 patterns created based on existing torso block drafting methods.

Digital Watermarking Algorithm for Copyright Protection of JPEG Image (JPEG 영상의 저작권 보호를 위한 Digital Watermarking 알고리즘)

  • Park, Eun-Suk;Woo, Jong-Won;Lee, Seok-Hee;Heo, Yoon-Seok;Cho, Ki-Hyung
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.1
    • /
    • pp.296-305
    • /
    • 2000
  • In this paper, we propose the method of embedding the encrypted digital watermark in quantization coefficient when we encode the image data in the process of JPEC. The proposed method is as following. After a DCT coefficient of each block is quantized, we arrange the quantization coefficient as on dimension with a zigzag scan and replace each block. By applying even-odd feature of frequency of the encrypted watermark to a quantization coefficient of some fixed domain of replaced each block and embedding it, we obtain the compressed image data by encoding after placing it in the order prior to replacement. The advantages of the proposed method here are as follows: We can embed many information keeping a secret as much as possible by using the algorithm of block replacement. We can control the amount of embedding of each use, as we embed the encrypted information by selecting some fixed domain of a quantization coefficient, we can fix the embedding data regardless of the image and the value of quantization. We verified the results by experiments and analyzed the efficiency of them in comparison with the former study.

  • PDF

Bacterial Meningitis during Continuous Epidural Block (지속적 경막외 차단중 발생한 세균성 뇌막염)

  • Lee, Jung-Koo;Chung, Jung-Gil
    • The Korean Journal of Pain
    • /
    • v.7 no.1
    • /
    • pp.113-115
    • /
    • 1994
  • Bacterial meningitis is a rare complication of epidural block. As epidural abscess, subarachnoid infection associated with epidural catheters are related to the treatment of pain in diabetic patient whose immune responses have been impaired. A 51-year-old male with non-insulin dependent diabetes came to the pain clinic with neuropathic gain on right thigh and amputated stump of right leg. Treatment consisted of continuous epidural block and subcutaneous tunnelling and epidural morphine with bupivacaine was given on an outpatient basis. Two months later, the patient noted a diffuse frontal headache, projectile vomiting and stiffness neck. These symptoms became more aggrevated over the following 24 h and temperature went up to $38.4^{\circ}C$. A diagnostic lumbar puncture revealed CSF total protein of 747 mg/dl, glucose of 43 mg/dl, and $4320\;WBC/mm^3$. Cultures of epidural catheter tip grew hemolytic staphylococcus epidermidis. A chest x-ray and brain CT scan were negative. Antibiotic therapy with penicillin G and chloramphenicol was given for 15 days. Recovery was uneventful.

  • PDF

A New Low Power LFSR Architecture using a Transition Monitoring Window (천이 감시 윈도우를 이용한 새로운 저전력 LFSR 구조)

  • Kim Youbean;Yang Myung-Hoon;Lee Yong;Park Hyuntae;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.8 s.338
    • /
    • pp.7-14
    • /
    • 2005
  • This paper presents a new low power BIST TPG scheme. It uses a transition monitoring window (TMW) that is comprised of a transition monitoring window block and a MUX. When random test patterns are generated by an LFSR, transitions of those patterns satisfy pseudo-random gaussian distribution. The Proposed technique represses transitions of patterns using a k-value which is a standard that is obtained from the distribution of U to observe over transitive patterns causing high power dissipation in a scan chain. Experimental results show that the Proposed BIST TPG schemes can reduce scan transition by about $60\%$ without performance loss in ISCAS'89 benchmark circuits that have large number scan inputs.

Drafting Method of Upper Bodice Pattern using 3-D Anthropometric Data for Elderly Women (노년 여성 3-D 입체형상 데이터를 활용한 상반신 원형 설계방법 연구)

  • Suh, Chu-Yeon;Park, Soon-Jee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.5
    • /
    • pp.846-858
    • /
    • 2008
  • This study was designed to propose a method to draft bodice block pattern from 3D body scan data. Subjects were ten elderly women in their 60's, who wear basic size(B: 94cm, W: 82cm) garment. Scanning was done using 3D whole body scanner(WB4, Cyberware). Measurements for 3D data and cross section were attained using Auto CAD, by which a upper bodice pattern for elderly women was drawn on the basis of short measured method. The results are as following: As for most items, no significant differences were shown between measurements from Martin's anthropometry and those from 3D scan data, suggesting measurement from 3D scan data could be used to draft a pattern. The drafting equations acquired were as follows; width of pattern=B/2+5.5, width of waist=W/2+3.5cm, dart amount=8cm. Dart distributions were 23%(B.P.) : 20%(front armpit) : 17%(side seam) : 18%(back armpit) : 15%(back protruded point) : 7% (center back line). Through wearing test using 5-point Likert scale, resultant pattern was evaluated as appropriate for elderly women's pattern to get over 4 point. As a result, it might be said that 3D scanning application is effective for elderly women in that it doesn't take time so much as Martin's anthropometry and that their body shape vary compared with those of young women.

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.