• Title/Summary/Keyword: Blind test

Search Result 415, Processing Time 0.029 seconds

Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination (족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구)

  • Moon, Joo-Wan;Han, Jae-Bok;Choi, Nam-Gil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • The purpose of this study was to determine suitable angle of Tibia-foot and the X-ray tube for scaphoid in foot X-ray examination. A total of twenty patients(mean age $32.12{\pm}years)$ are participated in this study. In the positions of Foot AP, internal and external oblique, tibia-foot angle was defined as $90^{\circ}$ and $135^{\circ}$, and x-ray tube angle was defined as $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$ respectively. The image quality was evaluated with blind test yielding scores ranging from 0 to 5 by the evaluation team consisted of 2 radiogical technologists, 2 radiologists, and 2 orthopedic surgeons. In case of Foot AP position, the degree of overlap between cuneiform and navicular was 3% and the blind test result was 4.89 at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle. When the tibia-foot angle is $135^{\circ}$, the degree of overlap was 5%, also the blind test result was 4.30 at $15^{\circ}$ X-ray tube angle. The degree of overlap and blind test result were 30% and 3.75 respectively at $0^{\circ}$ X-ray tube angle. In case of internal oblique position, at tibia-foot angle of $90^{\circ}$ and $0^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test result was 4.70. The 5% overlapping and highest score as 4.55 were obtained on tibia-foot angle of $135^{\circ}$ and $0^{\circ}$ X-ray tube angle. In case of external oblique position, at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test score was 4.85. The 5% overlapping and highest score as 4.75 were obtained on tibia-foot angle of $135^{\circ}$ and $15^{\circ}$ X-ray tube angle. In conclusion, we confirmed suitable angle of tibia-foot and X-ray tube for scaph46oid in foot X-ray examination in this study. These findings will be helpful for us to reading for navicular fracture.

Effects of a mouthwash containing potassium nitrate, sodium fluoride, and cetylpyridinium chloride on dentin hypersensitivity: a randomized, double-blind, placebo-controlled study

  • Hong, Ji-Youn;Lim, Hyun-Chang;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.1
    • /
    • pp.46-56
    • /
    • 2016
  • Purpose: We evaluated the efficacy of a mouthwash containing potassium nitrate ($KNO_3$) as its main component, along with sodium fluoride (NaF) and cetylpyridinium chloride (CPC). The primary endpoint was the relief of dentin hypersensitivity (DH) against the cold stimuli. The effects on other DH tests and periodontal inflammation were also evaluated. Methods: We used a single-center, double-blind, placebo-controlled, randomized design. A total of 82 patients with DH (40 in the test group, 42 placebo controls) were analyzed using visual analog scales (VASs) for a cold test, a tactile test, a compressive air test, and self-reported pain during daily activities, as well as clinical parameters including plaque index, gingival index, modified sulcular bleeding index (mSBI), gingival recession, and probing depth, which were collected at baseline and after four and six weeks of mouthwash use. Results: VAS scores for cold sensations, tactile sensations, the compressive air test, and self-reported pain significantly decreased from baseline during the six weeks in both groups (P<0.01), and no significant differences between the groups were found. In male patients (10 in the test group and 7 in the control group), both groups showed significant reductions in VAS scores for the cold test over the six weeks, and greater reductions were found in the test group than in the control group between four and six weeks (P=0.01) and between baseline and six weeks (P<0.01). In addition, the mSBI in the test group significantly decreased from baseline during the six weeks (P<0.01), and the changes at four and six weeks from baseline were significantly greater in the test group compared to the control group (P=0.03 and P=0.02, respectively). Conclusions: A mouthwash containing a mixture of $KNO_3$, NaF, and CPC reduced DH and gingival inflammation, however, the efficacy was comparable to the control group.

The Flame and Distributed Temperature Restraint Properties of Fire Venetian Blind Louver in Buildings (차양식 방화루버의 화염 및 온도 전파 억제 특성)

  • Chae, Young-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.120-127
    • /
    • 2015
  • The purpose of this study is to improve the fire prevention performance using the fire venetian blind louver subjected to burning by fire flame. The investigation is based on testing 2 full scale specimens, which is $3m{\times}3m$ module, $850mm{\times}1,500mm$ open, and $900mm{\times}900mm{\times}175mm$ venetian blind louver. Two louver thickness (1.5 and 2.0mm) were adopted. The specimens were exposed to fire flame temperature levels of ISO834 at the lower surface of the fire venetian blind louver specimens with exposure duration of one hour in Korea Institute of Construction Technology (KICT). It was found from the test results that the values of distributed temperature, decreased for all specimens for protecting to fire flame by venetian blind louver. The results of tests were a good fire prevention performance between in initial to 6 mins. At 60 minutes around ISO 834 fire loading, the percentages of distributed temperature in 500mm and 800mm height ranged between 11 and 10% respectively, regardless of louver thickness. This study, therefore, will improve the fire venetian blind louver for fire protection and prevention performance.

A Study of Developing the Ubiquitous Library for the Improvement of Information Accessability of the Blind (시각 장애인의 정보접근성 향상을 위한 유비쿼터스 도서관 구축에 관한 연구)

  • Bae Kyung-Jae;Kwak Seung-Jin
    • Journal of Korean Library and Information Science Society
    • /
    • v.37 no.2
    • /
    • pp.273-290
    • /
    • 2006
  • Recently, a digital divide has gotten worse in the information age. So LG Sangnam library developed the ubiquitous library for the improvement of information accessability of the blind. It utilizes a mobile phone applied with NFC (Near Field Communication) technology and automates a user's identification process and serve library services at anytime from anywhere. Users can use three access points of a web service, a mobile service and a telephone library service. As a conclusion of this paper. Several recommendations were proposed. For the development of ubiquitous library, various instruments should be considered to diversify user's access points and a usability test and analysis about user's environmental context should be done simultaneously.

  • PDF

Understanding Smartphone-based Online Shopping Experiences and Behaviors of Blind Users

  • Park, Jihyuk;Han, Yeji;Oh, Uran
    • International journal of advanced smart convergence
    • /
    • v.9 no.3
    • /
    • pp.260-271
    • /
    • 2020
  • Smartphones provide blind users with screenreader as an accessibility tool. However, blind users often experience difficulties accessing online shopping malls via smartphones due to their inconsistent and image-based layouts. To enable screenreader users to get access to the detailed information about products while they are shopping online, we have developed BarrierFreeShop, an accessible mobile shopping application for people with visual impairments. BarrierFreeShop has three accessibility features: (1) layout automation, (2) review summarization, and (3) optical character recognition. We conducted a user study with 80 participants with visual impairments where they were asked to use BarrierFreeShop for a month. The findings revealed the effectiveness of our app in terms of speed and post interview feedback. We have also discovered typical shopping experiences that participants had during the test. This research suggests that computer vision technologies can improve accessibility issues in online shopping malls. In addition, we have confirmed that extracting contents from images help people with visual impairments to get better access to product information.

Anchored blind bolted composite connection to a concrete filled steel tubular column

  • Agheshlui, Hossein;Goldsworthy, Helen;Gad, Emad;Mirza, Olivia
    • Steel and Composite Structures
    • /
    • v.23 no.1
    • /
    • pp.115-130
    • /
    • 2017
  • A new type of moment-resisting bolted connection was developed for use in composite steel- concrete construction to connect composite open section steel beams to concrete filled steel square tubular columns. The connection was made possible using anchored blind bolts along with two through bolts. It was designed to act compositely with the in-situ reinforced concrete slab to achieve an enhanced stiffness and strength. The developed connection was incorporated in the design of a medium rise (five storey) commercial building which was located in low to medium seismicity regions. The lateral load resisting system for the design building consisted of moment resisting frames in two directions. A major full scale test on a sub-assembly of a perimeter moment-resisting frame of the model building was conducted to study the system behaviour incorporating the proposed connection. The behaviour of the proposed connection and its interaction with the floor slab under cyclic loading representing the earthquake events with return periods of 500 years and 2500 years was investigated. The proposed connection was categorized as semi rigid for unbraced frames based on the classification method presented in Eurocode 3. Furthermore, the proposed connection, composite with the floor slab, successfully provided adequate lateral load resistance for the model building.

A New Robust Blind Crypto-Watermarking Method for Medical Images Security

  • Mohamed Boussif;Oussema Boufares;Aloui Noureddine;Adnene Cherif
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.3
    • /
    • pp.93-100
    • /
    • 2024
  • In this paper, we propose a novel robust blind crypto-watermarking method for medical images security based on hiding of DICOM patient information (patient name, age...) in the medical imaging. The DICOM patient information is encrypted using the AES standard algorithm before its insertion in the medical image. The cover image is divided in blocks of 8x8, in each we insert 1-bit of the encrypted watermark in the hybrid transform domain by applying respectively the 2D-LWT (Lifting wavelet transforms), the 2D-DCT (discrete cosine transforms), and the SVD (singular value decomposition). The scheme is tested by applying various attacks such as noise, filtering and compression. Experimental results show that no visible difference between the watermarked images and the original images and the test against attack shows the good robustness of the proposed algorithm.

A Study on the Optimization of Exposure condition at Lumbar projection Using Blind Test (블라인드 테스트를 통한 요추 검사 시 조사 조건의 최적화 연구)

  • Park, Jikoon;Kim, Kyotae;Yoon, Inchan;Choi, Ilhong;Jung, Hyungjin;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.389-395
    • /
    • 2013
  • This study intended to investigate the optimum conditions for lumbar test that has the highest level of irradiation conditions among general test sites. To to this, the most widely used irradiation conditions in terms of statistics were set as standards; test groups applied with DMF were selected; tests groups suitable for clinical trials were selected by using suggested patient dose. Blind tests were conducted by 10 specialists and radiologists. The results suggested that under the optimum conditions, the radiation dose reduction of 2.09 mGy, 4.42 mGy and 3.65 mGy can be achieved in forward-backward test, lateral test and 4-direction test, respectively. There is a need of further studies on the optimization of irradiation conditions in accordance with the conditions of patients.

A Randomized Study, Double-Blind, Placebo-Controled Study to Herbal Shampoo & Essence about Dandruff (한방 샴푸/에센스의 비듬에 대한 무작위배정, 이중맹검, 위약 대조군 연구)

  • Kim, Chagn-Hun;Hwang, Dong-Sung;Kim, Jung-Tae;Jung, Hyeon-A;Roh, Seok-Seon;Lim, Nam-Kyoo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.20 no.3
    • /
    • pp.222-235
    • /
    • 2007
  • Background : Dandruff is a chronic scalp condition characterized by scaling. The common causative agent is now accepted to be the lipophilic Pityrosporum ovale. Obstecive : We conducted a randomized, double-blind, parallel-group study to investigate the efficacy of Herbal Shampoo & Essense and placebo in patients with mild to moderate dandruff. Mathods : Forth-seven patients with dandruff were assigned to one of two treatment goups: Test (contaning the medication) or control (vehicle). After administering through randomizion, two groups were used with Negative sampoo for first two weeks, and used with test or control products for second two weeks. Results : 1. After 2 weeks of treatment, the numbers of P. ovale in test groups were decreased in a statistically meaningful way(p<0.01) compared with control groups. 2. After 2 weeks of treatment, average of sebum-amount in test groups were decreased from 117.55 to 92.88, in a statistically meaningful way(P<0.05, paired t-test) compared with control groups that were decreased from 115.53 to 112.46. 3. In clinical score, average of control groups is decreased from 2.82 to 1.09. on the other sides, average of test groups is decreased from 3.88 to 2.44. The change of test groups is bigger than that of control groups, both two groups was decreased in a statistically way(<0.01) Conclusion : The study demonstrated that Herbal Shampoo & Essense can be used by patients with scalf safely and effectively with almost no side-effect.

  • PDF