Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding (블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;La, Woon;Im, Ju Hyeuk;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content arc satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When, AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding (블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성)

  • Kim, Ki-Hoon;Hwang, Yin-Seong;La, Woon;Im, Ju-Hyeuk;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When. AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

Engineering Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for the Type of Bleeding Reduction (블리딩저감형 AE감수제를 사용한 콘크리트의 공학적 특성)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Lee, Seung-Hoon;Kim, Gyu-Dong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.133-140
    • /
    • 2004
  • This study is intended to investigate the properties of bleeding reduction of concrete using AE water reducing agent for the type of bleeding reduction with the replacement admixture. According to the results, when the adding ratio of AE water reducing agent for the type of bleeding reduction increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 50 min. When AE oater reducing agent for the type of bleeding reduction is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for the type of bleeding reduction. Synthetically, it proves that AE water reducing agent for the type of bleeding reduction satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

Motility and Absorptive Capacity of the Ileum in Acute Hemorrhage (급성실혈시의 회장운동과 흡수기능)

  • Hwang, Jeong-Woon
    • The Korean Journal of Physiology
    • /
    • v.7 no.2
    • /
    • pp.39-47
    • /
    • 1973
  • The influences of the acute hemorrhage on the intestinal functions were studied in the rabbits subjected to acute bleeding, amounting 1.5-2% of the body weight. The motility and the absorptive capacity of the ileum were compared before and after the bleeding. Transfusion of shed blood was also performed in order to see whether the deteriorations were reversible or not. The tension developed in the direction of the longitudinal axis of the ileum was recorded through an appropriate transducer, and the frequency of the rhythmic contraction was counted throughout the procedure. Test solution, 10ml in amount, was placed in the loop of the ileum, and the samples were drawn at zero time and at 20 minutes. Triplicated procedures were repeated on the same loop;namely, before and after bleeding and after transfusion. The test solution was composed of 200 mg% urea, 218 mEq/l of NaCl and 150 mg% of polyethylene glycol (PEG) No. 4,000 in distilled water. The latter substance was used as a marker substance for the volume change of the loop. The results obtained were as follows; 1. The motility of the ileum suffered little effects by acute hemorrhage. However, minor fluctuations were seen in the frequency of the rhythm, showing a slight tendency of decreasing rhythmicity, and it was reversed by transfusion. 2. Diminution of absorptive capacity of urea was noticed in acute hemorrhage and it was interpreted as the consequence of the secondary effect of the retardation of the active transport mechanism governing the sodium transport 3. Absorption rate of the sodium ion was dropped in the hemorrhage, suggesting the indispensable need of the blood supply. 4. Osmolarity of the luminal fluid remained higher in the case of acute hemorrhage. 5. There was a tendency of retaining more fluid in the intestinal lumen in acute hemorrhage, comparing with that observed prior to the bleeding. 6. The deteriorations in the absorptive capacity were restored by transfusion of shed blood.

  • PDF

The Experimental study on the property of concrete which used Blast furnace slag aggregate (고로슬래그 골재를 사용한 콘크리트 특성에 대한 실험적 연구)

  • 박정우;김상미;김광기;임남기;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.489-494
    • /
    • 2001
  • Several studies have reported that Granulated Blast-Furnace Slag improved the properties of concrete. The Granulated Blast-Furnace Slag could be a good alternative in the shortage of aggregate situation. Slag shows the possibility of influential aggregate and effect of environment preservation. This study presents that the basic properties of fresh concrete using Air-cooled Blast-furnace slag aggregate and Water-cooled Blast-furnace slag aggregate. Testing Factors of this study are concrete slump, slump loss, bleeding, and air contents. The result of this study is below. 1) In case of proportion slag and grave is 50 to 50, the biggest slump value is measured. 2) In the concrete using of air-cooled Blast-furnace slag aggregate, the bleeding capacity is a little. In the concrete using of Water-cooled Blast-furnace slag aggregate, the bleeding capacity goes up to 50% increase. 3) As substitution rate of the granulated blast-furnace slag goes up, air content is increased.

  • PDF

Research on the heating performance of SCW heat pump system for residential house (주거용 건물의 지하수 이용 지열 히트펌프 시스템의 난방성능 특성에 관한 연구)

  • Kim, Ju-Hwa;Kim, Ju-Young;Hong, Won-Hwa;Ahn, Chang-Hwan
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.431-435
    • /
    • 2008
  • Geothermal heat pump system using standing column wells as their ground heat exchanger can be used as a highly efficient source of heating and cooling in massive buildings. But there is no case of a small scale residential house. So this study estimated heating coefficient of performance(COP) of geothermal heat pump system using standing column well type which is excellent in heat recovery in the residential house. As a result of analysis, The COP of heat pump is over average 6 and is excellent. And in consequence of making a comparative study according to the bleeding, the cop is higher in the case of bleeding. Therefore, bleeding affects the performance of the system. This study has shown performance result that stands on actual data. Therefore, this study provides ground data that needs when a low capacity of system designs for a residence with confidence elevation.

  • PDF

An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data (열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석)

  • Chang, Keun-Sun;Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.512-520
    • /
    • 2020
  • Recently, the applications of the standing column well (SCW) ground heat exchanger (GHX) have increased significantly in Korea as a heat transfer mechanism of ground source heat pump systems (GSHP) because of its high heat capacity and efficiency. Among the various design and operating parameters, bleeding was found to be the most important parameter for improving the thermal performance, such as ground thermal conductivity and borehole thermal resistance. In this study, a bleeding analysis model was developed using the thermal response test data, and the effects of bleeding rates and bleeding locations on the thermal performance of anSCW were investigated. The results show that, when the ground water flows into the top of anSCW, the time variation of circulating water temperature decreased with increasing bleeding rate, and the ground thermal conductivity increases by as much as 179% with a 30% bleeding rate. When the ground water flows into the bottom of the SCW, the circulating water temperatures become almost constant after the increase in the beginning time because the circulating water exchanges heat with the ground structure before mixing with the ground water at the bottom.

A Study on the Heating Performance of SCW Type Geothermal Heat Pump System for Residential House (지하수 이용 지열 히트펌프 시스템의 주거용 건물 적용시 난방성능 특성에 관한 연구)

  • Kim, Ju-Hwa;Kim, Ju-Young;Hong, Won-Hwa;Ahn, Chang-Hwan
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.11-18
    • /
    • 2008
  • Geothermal heat pump system using sanding column well type with their ground heat exchanger can be used as a highly efficient source of heating and cooling in massive buildings. But there is no case of a small scale residential house. So in the residential house this study estimated heating coefficient of performance (COP) of geothermal heat pump system using sanding column well type which is excellent in heat recovery. As a result of analysis, The COP of heat pump is over average 6 and is excellent. And in consequence of making a comparative study according to the bleeding, the COP is higher in the case of bleeding. Therefore, bleeding affects the performance of the system. This study has shown performance result that stands on actual data. Therefore, this study provides ground data that needs when a low capacity of system designs for a residence with confidence elevation.

Effect of Bleeding Time on Meat Quality and Shelf-Life of Broiler (방혈 시간이 닭고기의 품질 및 저장성에 미치는 영향)

  • Chae H. S.;Ahn C. N.;Yoo Y. M.;Ham J. S.;Jeong S. G.;Lee J. M.;Choi Y. I.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.3
    • /
    • pp.187-193
    • /
    • 2005
  • This study was carried out to investigate the effect of the bleeding times(30sec., 90sec., 150sec.) at slaughtering process on meat quality and storage properties of broiler. The redness$(a^{\ast}\;value)$ of skin, wing, leg muscle decreased at high bleeding time(150sec.). However, there was no significant difference in breast muscle. WHC(water holding capacity) of breast muscle decreased from $63.64\%$ at low bleeding time(30sec.) to $61.06\%$ at high bleeding time. TBARS(thiobarbituric acid-reactive substance) values were 0.18 mgMA/kg at the low bleeding time, 0.16 mgMA/kg at the middle bleeding time(90sec.) and 0.21mgMA/kg high bleeding time on 3 days of storage. Total aerobic plate counts(TPC) were $6.25logCFU/cm^2$ at the low bleeding time, $6.25logCFU/cm^2$ at the middle bleeding time and $6.53logCFU/cm^2$ at the high bleeding time. The TPC was increased as the bleeding time increased. In conclusion, meat color of chicken were acceptable when the carcasses were slaughtered at the high bleeding time.

An Experimental Study on the Fundamental Properties of Zeolite Concrete (제올라이트 콘크리트의 기초 물성에 관한 실험적 연구)

  • Jo, Byung Wan;Choi, Ji Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Since the cement industry is expected to face serious setbacks in the near future associated with environmental concerns. With the advent of new technologies and increased public awareness about global environmental issues, the cement industry is actively seeking to adopt new technologies as part of an effort to diversity its resources. This study is designed to assess the fundamental properties of zeolite cement concrete which consists mainly of natural zeolite, which is known for removal of and harmful gas, ion exchange capacity removing cation contaminant including heavy metals and ammonia, absorptive capacity and molecular sieving effect together with excellent insulation capacity as a porous material, and recently draws much attention for its possibility as an alternative material to cement. The study was conducted to show the compressive strength of concrete, slump, bleeding and air volume according to the changes of natural zeolite and alkali activator(NaOH). As a result of measuring the compressive strength of natural zeolite concrete, it was almost 40MPa and displayed similar to general concrete in the tests of slump, bleeding and air volume, with which it was considered that it may be used as a future high performance, high performance construction material.