• 제목/요약/키워드: Blasting Noise

검색결과 152건 처리시간 0.023초

주거지역 터널공사에서의 발파진동 저감사례 (A Case of Blasting Vibration Reduction in the Tunnel Construction under a Residential Area)

  • 강진욱;이현구;이명철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.175-180
    • /
    • 2007
  • This paper presents a case study on blasting vibration reduction in NATM(New Australian Tunnelling Method) tunnel construction carried out under a congested residential area. In NATM tunnel constructions, blasting is an essential process, thus vibration phenomenon is inevitable. Therefore, the vibration reduction was tried to avoid expected complaints from the public living in the area. Test blastings were performed to get the constants for an estimation formula of vibration velocity. Then the influence area was approximated using the estimation formula, and construction methods for the vibration reduction were sought based on the results.

  • PDF

전자뇌관(HiTRONIC II™)을 이용한 수직구 시공 사례 (A Case Study on the Shaft Construction Using Electronic Detonators)

  • 황남순;진근우;여진혁;정동호;김연홍
    • 화약ㆍ발파
    • /
    • 제38권2호
    • /
    • pp.22-35
    • /
    • 2020
  • 최근 전자뇌관은 다양한 현장에서 폭넓게 사용되어지고 있다. 흔히 전자뇌관은 발파에 의해 발생되는 소음과 진동을 줄이기 위한 목적으로 사용된다. 또한 일반뇌관에 의한 발파작업이 불가능한 지역이나 보안물건이 근접하여 기계식굴착 공법이 적용된 현장에서 정밀한 발파작업을 위해 전자뇌관을 사용하고 있다. 발파현장에서는 전자뇌관을 이용하여 시공성을 높이고 생산원가를 낮추기 위한 다양한 기술이 시도되고 있다. 본 사례는 보안물건이 근접해 있는 지역에서 전자뇌관을 사용하여 보안물건에 대한 허용기준치를 충족시키면서 작업의 효율성을 높인 시공사례를 소개한다. 한화에서 생산하는 하이트로닉II(HiTRONIC II™)를 사용하여 국내 및 해외 수직구 현장에서 작업을 시행하였다. 일반적으로 수직구 현장에서는 발파에 따른 소음과 진동 영향 때문에 굴착면을 분할하여 발파를 시행한다. 그러나, 본 사례에서는 발파 굴착면을 1회에 전단면발파를 실시하였으며 이에 따른 공사기간을 단축시킬 수 있었다.

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 이연수;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.521-526
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, Z(perpendicularity) axis was the highest value in vibration level, but vertical axis was the highest value at 25m point and longitudinal axis was the highest value at 50m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, 2 axis was the highest value in vibration level, but in vibration velocity transverse axis was the highest value at ground, was vertical axis at 1st floor, was longitudinal axis at 3rd floor and was vertical and longitudinal axis at 5th floor. The vibration level and the vibration velocity of 50m point showed higher correlation value than 25m point at the ground, but those of 25m point showed higher correlation value than 50m point at the apartment.

  • PDF

도심지 발파공사장의 발파진동 특성 (The Characteristics of Blasting Vibration in the Construction of Apartment and Buildings in Urban Area)

  • 장서일;이연수
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.632-638
    • /
    • 2004
  • In order to evaluate the effect of blasting vibration in buildings and it's resident located around blasting construction field in urban area, blasting vibration characteristics were measured by the vibration level, vibration velocity. The 250g and 750g of charged powder were used at the apartment and at the ground, respectively. In the measurement of the ground, 2 (perpendicularity) axis was the highest value in vibration level, but vertical direction was the highest value at 25 m point and longitudinal direction was the highest value at 50 m point in vibration velocity. The amount of measurement was high value when measuring point is higher than blasting source, while that of measurement was low value when measuring point is lower than blasting source. In the measurement of the apartment, Z axis was the highest value in vibration level, but in vibration velocity transverse direction was the highest value at ground, was vertical direction at 1st floor, was longitudinal direction at 3rd floor and was vertical and longitudinal direction at 5th floor. The vibration level and the vibration velocity of 50 m point showed higher correlation value than 25 m point at the ground, but those of 25 m point showed higher correlation value than 50 m point at the apartment.

무진동 굴착구간에 대한 전자뇌관의 적용성 평가 사례 (A Case Study on the Applicability Evaluation of Electronic Detonator for Non-Vibration Excavation Section)

  • 정승원;송진혁;황남순;김남수;정민성
    • 화약ㆍ발파
    • /
    • 제40권4호
    • /
    • pp.47-56
    • /
    • 2022
  • 당 현장 주변에 보안물건이 위치하고 있어, 기존 설계상에 176m 구간이 무진동 기계식 굴착공법으로 설계되었으나, 시공성 및 경제성 향상을 위하여 전자뇌관 미진동 발파공법을 제안하였다. 검토 결과, 발파소음, 진동 모두 허용기준 이내의 안전성을 확보하여 해당 구간에 대하여 전자뇌관 미진동 발파공법 적용 가능성을 확인하였다. 아울러 검토 구간에서 무진동 굴착공법과 전자뇌관 미진동 발파공법을 비교한 결과, 공사 기간을 88일 단축하여 경제적으로 큰 이점이 있는 것으로 평가되었다.

터널 방음시설의 방음재질 종류에 따른 소음과 주파수의 크기 고찰 (A Study on the Magnitude of the Noise and Frequency According to Materials for Soundproof Facilities of Tunnel)

  • 원연호;조영동;정재형
    • 화약ㆍ발파
    • /
    • 제25권2호
    • /
    • pp.23-33
    • /
    • 2007
  • 터널발파작업에 따른 발생소음의 크기는 소음 계측기의 특성상 근거리의의 측정이 불가하며 방음재질의 종류에 따라 소음저감 효과는 매우 다양한 차이를 나타낸다. 본 연구에서는 터널발파작업에 따라 설치되는 방음시설의 방음재질과 종류에 따른 소음저감 효과와 근거리에서의 소음예측방법을 조사하였다. 방음재질과 종류에 의한 소음과 주파수의 크기를 비교 분석하기 위하여 콘크리트 흄관 내에서 화공품의 일종인 폭죽으로 소음을 발생시키고 약 20여 종류의 방음재질을 설치하여 근거리에서 소음과 주파수의 크기를 측정 고찰하였다.

서울지하철공사 8-6공구터널 발파작업으로 인한 진동, 소음이 지상주택가 구조물에 미치는 연구조사 (On the Influence Study to Building by Seoul Sub-way(8-6 site) Tunnel works)

  • 허진;전상백
    • 화약ㆍ발파
    • /
    • 제12권1호
    • /
    • pp.5-31
    • /
    • 1994
  • On the Seoul Sub-way Tunnel works (8-6 site ). Cautious blasting works were so effectivelly tarried out the vibration record were under 0.3cm /sec and blasting noise was under 75dB which was measured at the ground of house. As a result cautious blasting works under above allowable value was not influenced the structure of house and living. On the architectural survey, There were some hair crack on the wall and floors but this was not a crack from balsting work.

  • PDF