• Title/Summary/Keyword: Bladder volume

Search Result 117, Processing Time 0.026 seconds

A Comparison between Three Dimensional Radiation Therapy and Intensity Modulated Radiation Therapy on Prostate Cancer (전립샘암의 방사선 치료 시 입체조형치료법와 세기조절방사선 치료법의 비교)

  • Kim, YoungJae;Lee, JaeSub;Hong, Seongill;Ko, HyeJin
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.409-414
    • /
    • 2013
  • In this study, we evaluated to the superiority of treatment techniques on prostate cancer, apply to each other treatment techniques-3D conformal therapy versus IMRT-using dose distribution and dose coverages. Obtained 10 patients CT simulation, divided tumor volume and critical organs. Prescription dose was 80 Gy on tumor volume and Each of plans was set by two different plans. As a result, Dose coverage was superior to IMRT. The IMRT's tumor absorbed dose(100.2%) was close to prescription doses. Normal tissue(bladder, rectal, bowel Lt Rt fumoral head) absorbed dose rate was superior. In other words, the radiation therapy of prostate cancer with intensity modulated radiation therapy was better than conformal radiation therapy on dose.

Ontogenetic Development of the Digestive System in Chub Mackerel Scomber japonicus Larvae and Juveniles

  • Park, Su-Jin;Lee, So-Gwang;Gwak, Woo-Seok
    • Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.301-309
    • /
    • 2015
  • Chub mackerel, Scomber japonicus, larvae and juveniles were reared from hatching to 35 days after hatching (DAH), and the development of their digestive systems was histologically investigated. The larvae were initially fed on rotifers and Artemia nauplii starting around 19 DAH, and thereafter on Artemia nauplii, fish eggs, and a formulated feed mixture. The primitive digestive system differentiated at 3 DAH; the digestive tract was distinctively divided into the buccopharyngeal cavity, esophagus, stomach, air bladder, intestines, and rectum. The gastric gland and pyloric caeca first appeared at 5 and 7 DAH, respectively. The stomach was divided into cardiac, fundic, and pyloric regions in the preflexion phase. The number of gastric glands and pyloric caeca, as well as the volume of the gastric blind sac increased markedly, with development continuing into the juvenile stage. The precocious development of the digestive system during the larval period might be related to the early appearance of piscivory, which is able to support high growth potential. The organogenesis results obtained for this precocial species represent a useful tool to aid our understanding of the physiological requirements of larvae and juveniles to ensure optimal welfare and growth under aquaculture conditions, which will improve current rearing practices of this scombrid species.

Combination Treatment of Korean Medicine with Ohrim-san for Lower Urinary Tract Symptoms (LUTS) after Laparoscopic Myomectomy Patient : A Case Report (복강경하 근종적출술 후 발생한 하부요로증상에 대한 오림산을 포함하는 복합한의진료의 경과 : 증례보고)

  • Jeong, So-Mi;Jo, Hee-Geun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.3
    • /
    • pp.187-197
    • /
    • 2020
  • Objectives: This case report aims to report the clinical effectiveness of the combination treatment of Korean medicine on a post-laparoscopic myomectomy patient's lower urinary symptoms (LUTS). Methods: The patient who diagnosed with uterine myoma had Laparoscopic myomectomy. After the operation, the patient complained of dysuria, nocturia, frequent urination, urgent urination and urinary retention. The patient received combination treatment of Korean medicine during 14 days of hospitalization. The treatment included Ohrim-san, acupuncture, moxibustion, and pharmacoacupuncture. The effects were evaluated through the Numeric Rating Scale (NRS), Overactive Bladder Symptom Score (OABSS), Frequency-Volume chart, and 5-Level version of EuroQol-Five Dimension (EQ-5D-5L). Results: After the treatment, the clinical symptoms such as dysuria, nocturia, frequent urination, urgent urination, urinary retention were improved. Also, the quality of life was enhanced. Conclusions: This case report shows that the combination treatment of Korean Medicine with Ohrim-san may be effective for treating lower urinary tract symptoms (LUTS) after laparoscopic myomectomy.

Gene Therapy for Mice Sarcoma with Oncolytic Herpes Simplex Virus-1 Lacking the Apoptosis-inhibiting Gene, icp34.5

  • Lan, Ping;Dong, Changyuan;Qi, Yipeng;Xiao, Gengfu;Xue, Feng
    • BMB Reports
    • /
    • v.36 no.4
    • /
    • pp.379-386
    • /
    • 2003
  • A mutant herpes simplex virus 1, mtHSV, was constructed by inserting the E. coli beta-galactosidase gene into the loci of icp34.5, the apoptosis-inhibiting gene of HSV. The mtHSV replicated in and lysed U251 (human glioma cells), EJ (human bladder cells), and S-180 (mice sarcoma cells), but not Wish (human amnion cells) cells. With its intact tk (thymidine kinase) gene, mtHSV exhibited susceptibility to acyclovir (ACV), which provided an approach to control viral replication. An in vivo test with mtHSV was conducted in immune-competent mice bearing sarcoma S-180 tumors, which were treated with a single intratumoral injection of mtHSV or PBS. Tumor dimensions then were measured at serial time points, and the tumor volumes were calculated. Sarcoma growth was significantly inhibited with prolonged time and reduced tumor volume. There was microscopic evidence of necrosis of tumors in treated mice, whereas no damage was found in other organs. Immunohistochemical staining revealed that virus replication was exclusively confined to the treated tumor cells. HSV-1 DNA was detected in tumors, but not in the other organs by a polymerase chain reaction analysis. From these experiments, we concluded that mtHSV should be a safe and promising oncolytic agent for cancer treatment.

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT (체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Lee, Jeong-woo;Shin, Young-Joo;Kang, Dong-Jin;Jung, Jae-Yong
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

Comparison of Beam Transfer Methods between Tomo Therapy and Proton Therapy for Prostate Cancer Radiation Therapy (전립선암 방사선 치료 시 토모치료와 양성자치료 빔 전달방식 비교)

  • Park, Jung Min;Ko, Eun Seo;Lee, Jin Hee;Kim, Jin Won;Yang, Jin Ho;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Tomo therapy and Proton therapy treatment plans for the treatment of prostate cancer patients were established, and the characteristics of dose distribution according to beam delivery method using Tomo therapy IMRT method and Proton therapy PBS method to compare and analyze the treatment effect were sought. Materials and Methods: Tomo IMRT treatment plan and Proton PBS treatment plan were established using the Hi.art planning station 5.1.1.6 of Tomo therapy and Eclipse 13.7 of VARIAN for three prostate cancer patients who were treated with radiotherapy only for radical purposes without surgery. For the evaluation of two treatment plans, the average dose (Dmean) and maximum dose (Dmax) of PGTV were calculated from dose volume histogram (DVH) to confirm the coverage and calculate CI and HI. In OAR evaluation, the dose received from the rectal volume 25% and the dose received from the bladder were evaluated to compare the normal long-term protection effect. Results: The mean maximum doses of the three patients were 71.4Gy, 75.3Gy and the mean doses were 70.4Gy and 72.8Gy in the DVH of the Tomo IMRT and Proton PBS. The CI was 1.16 and 1.31, and the HI was 0.04 and 0.12 respectively, and the Tomo IMRT was superior to the Proton PBS in dose suitability. Conclusion: The mean dose of PGTV in prostate cancer patients was 3.4% higher in Proton PBS than in Tomo IMRT. This is because the Dose suitability of Tomo IMRT was better, but it is considered to be a small difference to be seen as a significant result. However, the results of the two methods were 51.2% in D 25% and 55.7% less in the average dose of bladder, which could reduce the side effects of patients in proton PBS.

Usability Assessment of Plan Transfer between TOMO HAD and Radixact : Planning Study (TOMO HDA와 Radixact 치료 계획 간 Transfer에 대한 유용성 평가 : Planning Study)

  • An, Ye Chan;Kim, Jong Sik;Kwon, Dong Yeol;Kim, Jin Man;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.117-128
    • /
    • 2018
  • Purpose : To evaluate the usability of plan transfer between TOMO HD and Radixact, we compared the differences of dose in transferred plans by evaluating the dose of normal organ and target. TOMO HDA and Radixact. The completed plans were transferred each other and we compared the differences of dose by evaluating the DVH of each plans. Materials and Methods : We planned 4 different plans assuming the treatment of 2 cases in Head and Neck Cancer and 2 cases Prostate cancer. Each plan was designed so that 95 % of the prescription dose was irradiated over 99 % of the target volume, and the normal organ constraints dose was based on the SMC tolerance dose protocol. Each plan was transferred to each equipment and DVH(dose volume histogram) analysis of the transferred plans was compared and evaluated. Results : The Mean dose of CTV and GTV was increased and decreased in the transferred plans, but there was no significant differences. The target coverage of CTV and GTV was decreased in all cases of transferred plans from TOMO HAD to Radixact, and the change of CI and HI in CTV was within 0.1. Normal organ dose was increased in most cases when transferring from HAD to Radixact in both treatment plans. Conclusion : According to the results of this experiment, the target coverage was above the standard and the normal organ dose was almost same or decreased when transferring the plans from Radixact to HDA equipment. However the target coverage was reduced when transferring the plans from HDA to Radixact and there was an increase in dose in normal organs that could cause sever side effects such as Optic Chiasm ($D_{max}$1.38 Gy), Bladder ($D_{max}$3.07 Gy), Penile Bulb ($D_{max}$1.14 Gy). Therefore, it is necessary to pay attention to the dose change when transferring the plan and one-time transfer due to equipment inspection will be useful for efficient radiation therapy, but if the transferred treatment plans continue for several consecutive days, the treatment plan should be resumed.

  • PDF

Dietary Sodium Effects on Responses of Atrial Natriuretic Peptide, Aldosterone and Renin Release to Acute Volume Expansion in SHR (장기간 고염 섭취한 SHR 고혈압 쥐에서, 급성 혈장량 증가에 대한 Atrial Natriuretic Peptide, Aldosterone 및 Renin 분비 반응의 비교)

  • Kim, Ae-Ra;Lee, Won-Jung;Choo, Young-Eun;Kim, Suhn-Hee;Cho, Kyung-Woo
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.253-261
    • /
    • 1989
  • Responses of atrial natriuretic peptide (ANP), aldosterone and renin release to acute volume expansion were compared in normotensive Wistar and spontaneously hypertensive rat (SHR) fed low or high-sodium diet (2 or 25 mmol Na/100 g diet). Experimental diets were fed for 6 weeks from 7-week-old and the growth rate was similar in all groups. In the morning of the experiment, catheters were inserted under ether anesthesia in femoral artery for pressure recording and blood collection, femoral vein for saline infusion, and bladder for urine collection. Then, the rats were placed in restraining cages. When the rats were recovered from anesthesia and the arterial pressure became stabilized, control urine and blood samples were collected. Then, 0.9% saline was infused for 30 min for volume expansion (3% BW). Arterial pressure was significantly higher in the high-sodium SHR but there was no difference between the two groups of Wistar rats. Control plasma levels of Na, K, ANP, renin activity, and hematocrit were not different among the 4 groups. However, plasma aldosterone level was significantly higher in the low-sodium groups. Wistar low-sodium rats showed approximately two times higher plasma aldosterone level than the SHR counterpart. Volume expansion produced a marked increase in plasma ANP level, especially in the high-sodium groups. The low-sodium groups of both strains showed approximately two-fold increase in plasma ANP level. Following a volume expansion plasma aldosterone level and renin activity decreased in all groups. There was a significant logarithmic positive correlation between plasma renin activity and aldosterone concentration. The low-sodium rats produced a greater increase in aldosterone release by small increase in plasma renin than did the high-sodium rats. The low- and high-sodium rats produced a similar degree of diuresis and natriuresis after volume expansion. However, SHR produced a greater natriuresis than did the Wistar rats. The above results indicate that regulatory mechanisms of ANP, aldosterone and renin release are different between the normotensive and hypertensive rats, and between the low- and high-sodium groups.

  • PDF