Error Recovery by the Classification of Candidate Motion Vectors for H.263 Video Communications (후보벡터 분류에 의한 영상 에러 복원)

  • Son, Nam-Rye;Lee, Guee-Sang
    • The KIPS Transactions:PartB
    • /
    • v.10B no.2
    • /
    • pp.163-168
    • /
    • 2003
  • In transmitting compressed video bit-stream over Internet, packet loss causes error propagation in both spatial and temporal domain, which in turn leads to severe degradation in image quality. In this paper, a new approach for the recovery of lost or erroneous Motion Vector(MV)s by classifying the movements of neighboring blocks by their homogeneity is proposed. MVs of neighboring blocks are classified according to the direction of MVs and a representative value for each class is determined to obtain the candidate MV set. By computing the distortion of the candidates, a MV with the minimum distortion is selected. Experimental results show that the proposed algorithm exhibits better performance in many cases than existing methods.

Web based 3-D Medical Image Visualization System on the PC (웹 기반 3차원 의료모델 시각화 시스템)

  • Kim, Nam-Kug;Lee, Dong-Hyuk;Kim, Jong-Hyo;Kang, Heung-Sik;Min, Byung-Goo;Kim, Young-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.201-205
    • /
    • 1997
  • With the recent advance of Web and its associated technologies, information sharing on distribute computing environments has gained a great amount of attention from many researchers in many application areas, such as medicine, engineering, and business. One basic requirement of distributed medical consultation systems is that geographically dispersed, disparate participants are allowed to exchange information readily with each other. Such software also needs to be supported on a broad range of computer platforms to increase the software's accessibility. In this paper, the development of world-wide-web based medical consultation system or radiology imaging is addressed to provide the platform independence and great accessibility. The system supports sharing of 3-dimensional objects. We use VRML (Virtual Reality Modeling Language), which is the de-facto standard in 3-D modeling on the Web. 3-D objects are reconstructed from CT or MRI volume data using a VRML format, which can be viewed and manipulated easily in Web-browsers with a VRML plug-in. A Marching cubes method is used in the transformation of scanned volume data set to polygonal surfaces of VRML. A decimation algorithm is adopted to reduce the number of meshes in the resulting VRML file. 3-D volume data are often very large-sized, and hence loading the data on PC level computers requires a significant reduction of the size of the data, while minimizing the loss of the original shape information. This is also important to decrease network delays. A prototype system has been implemented (http://netopia.snu.ac.kr/-cyber/). and several sessions of experiments are carried out.

  • PDF

Voice-based messenger using NXT touch-sensor input unit and the Bluetooth wireless communication for the blind (터치 센서 입력기와 블루투스 무선 통신을 이용한 시각 장애인용 음성 기반 메신저)

  • Lee, Jung-Il;Kim, Soon-Cheol;Won, Hui-Chul
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.5
    • /
    • pp.78-86
    • /
    • 2008
  • Many people have conveniently used various messengers to talk with remote friends or to send urgent files to remote co-workers. Recently, it is also possible to use messenger with user's image. However, these messenger technologies are of no use for the blind. In order to cope with this problem, we propose voice-based messenger with a Braille system for the blind. The proposed messenger enables the blind to listen to the received sentences from remote user. It also enables them to listen to the written sentences before sending to remote user for the purpose of checking that the sentences are correctly written. The Braille system for writing sentences can be implemented by using the programmable NXT system, which contains a 32-bit ARM-7 micro-controller, with 4 touch-sensors. Finally, we apply the Bluetooth technology for wireless communication between the Braille system and the proposed messenger.

  • PDF

A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports (DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF

A Study on Improvement about abnormal display of Multi Function Display for KUH (한국형 기동헬기 다기능시현기의 이상시현 개선에 관한 연구)

  • Kim, Young Mok;Chang, Joong Jin;Jun, Byung Kyu;Kim, Chang Young;Kim, Tae Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.4
    • /
    • pp.344-350
    • /
    • 2014
  • Multi Function Display(MFD) of Korean Utility Helicopter(KUH) is the component of mission management/display control system and displays image information(navigation, flight, survivability, digital map, maintenance) acquired from Mission Computer(MC) while the aircraft is operated. It is an essential equipment for pilots to perform flight mission and it has functions of display scene control, data display, built in test(BIT) and brightness control. In this paper, it is analyzed the cause of abnormal display(flickering) on MFD and summarized the design changes to solve the defect. It is also described system safety analysis and suggested verification results of flight/ground test.

Depth Map Based Distributed Multi-view Video Coding Scheme through an Efficient Side Information Generation (효율적인 보조 정보 생성을 통한 깊이지도 기반의 분산 다시점 비디오 코딩 기법)

  • Yoo, Ji-Hwan;Lee, Dong-Seok;Kim, Tae-June;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1093-1103
    • /
    • 2009
  • In this paper, we propose a new depth map based distributed multi-view video coding algorithm through an efficient side information generation. A distributed video coding scheme corrects errors between an original image and side information generated at a decoder by using channel coding techniques. Therefore, the more accurate side information is generated, the better performance of distributed video coding scheme is achieved. In the proposed algorithm, a distributed video coding scheme is applied to multi-view video coding based on depth map. Side information is also generated from images of adjacent views through 3D warping by using a depth map and is also combined with MCTI(motion compensated temporal interpolation) which uses images on a temporal axis, and 3D warping. Experimental results show that side information generated by using the proposed algorithm has 0.97dB better average PSNR compared with using MCTI and 3D warping separated. In addition, 8.01% of average bit-rate has been decreased while the same PSNR in R-D curves is kept.

A Study on Channel Decoder MAP Estimation Based on H.264 Syntax Rule (H-264 동영상 압축의 문법적 제한요소를 이용한 MAP기반의 Channel Decoder 성능 향상에 대한 연구)

  • Jeon, Yong-Jin;Seo, Dong-Wan;Choe, Yun-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.295-298
    • /
    • 2003
  • In this paper, a novel maximum a posterion (MAP) estimation for the channel decoding of H.264 codes in the presence of transmission error is presented. Arithmetic codes with a forbidden symbol and trellis search techniques are employed in order to estimate the best transmitted. And, there has been growing interest of communication, the research about transmission of exact data is increasing. Unlike the case of voice transmission, noise has a fatal effect on the image transmission. The reason is that video coding standards have used the variable length coding. So, only one bit error affects the all video data compressed before resynchronization. For reasons of that, channel needs the channel codec, which is robust to channel error. But, usual channel decoder corrects the error only by channel error probability. So, designing source codec and channel codec, Instead of separating them, it is tried to combine them jointly. And many researches used the information of source redundancy In received data. But, these methods do not match to the video coding standards, because video ceding standards use not only one symbol but also many symbols in same data sequence. In this thesis, We try to design combined source-channel codec that is compatible with video coding standards. This MAP decoder is proposed by adding semantic structure and semantic constraint of video coding standards to the method using redundancy of the MAP decoders proposed previously. Then, We get the better performance than usual channel coder's.

  • PDF

Novel optical representation of binary data to improve the beam intensity uniformity at the recording plane in the storage of Fourier holograms of digital data (디지털 데이터의 Fourier 홀로그램 저장에서 기록면의 빔세기 균일도 향상을 위한 2진 데이터의 새로운 광학적 표현)

  • 장주석;신동학;오용석
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.339-344
    • /
    • 2001
  • We propose a method to represent binary data by modulating both the intensity and the phase of uniform plane waves with a twisted-nematic liquid crystal display for holographic digital data storage especially in a disk-shaped recording medium. As far as intensity modulation is concerned, our method is not different from the conventional method, because binary bit values 0 and 1 are represented by the dark (off) and lit (on) states of the liquid crystal display pixels, respectively (or vice versa). With our method, however, the on pixels are also controlled so that the beams passing through them can have one of two different phase delays. If the difference of the two phase delays is close to 180 degrees, we can reduce the dc component of the data image and thus improve the beam intensity uniformity at the holographic recording plane when Fourier plane holograms are recorded. The feasibility of our method is experimentally demonstrated. rated.

  • PDF

Digital Image Watermarking Algorithm using Integer Block Transform (정수 블록 변환을 이용한 디지털 이미지 워터마킹 알고리즘)

  • Oh Kwan-Jung;Ho Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.5 s.311
    • /
    • pp.57-67
    • /
    • 2006
  • Intellectual property rights are gathering strength theses days. Because digital contents are easily reproduced and distributed by advanced computers and networks. Digital watermarking is one of the best solutions for this problem. Generally, frequency-domain watermarking algorithms are preferred since they are more robust than spatial-domain algorithms. However, coefficients in the frequency domain are floating-point numbers. Thus, it is not easy to manipulate those floating-point coefficients and frequency-domain watermarking algorithms have some limitations in their applications. In order to overcome this difficulty, we employ an integer transform in this paper. In addition, our proposed algerian can extract the watermark from both the spatial and frequency domains. We embed the watermark into a specific bit-plane of mid-frequency coefficients. This is equivalent to the differential energy watermarking (DEW) in the spatial domain. Our simulation results show that the proposed algorithm is imperceptible, good for the watermark payload, and robustness against various attacks. Moreover, it is more efficient than any other algorithm working in only one domain.

AN EXPERIMENTAL STUDY ON THE READABILITY OF THE DIGITAL IMAGES IN THE FURCAL BONE DEFECTS (디지털영상의 치근이개부 골손실 판독효과에 관한 실험적 연구)

  • Oh Bong-Hyeon;Hwang Eui-Hwan;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.363-373
    • /
    • 1995
  • The aim of this study was to evaluate and compare observer performance between conventional radiographs and their digitized images for the detection of bone loss in the bifurcation of mandiblar first molar. One dried human mandible with minimal periodontal bone loss around the first molar was selected and serially enlarged 17 step defects were prepared in the bifurcation area. The mandible was radiographed with exposure time of 0.12, 0.20, 0.25, 0.32, 0.40, 0.64 seconds, after each successive step in the preperation and all radiographs were digitized with IBM-PC/32 bit-Dx compatible, video camera (VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used. The obtained results were as follows: 1. In the conventional radiographs, the mean score of the readability was higher at the condition of exposure time with 0.32 second. Also, as the size of artificial lesion was increased, the readability of radiographs was elevated (P<0.05). 2. In the digital images, the mean score of the readability was higher at the condition of exposure time with 0.40 second. Also, as the size of artificial lesion was increased, the readability of digital images was elevated(P<0.05). 3. At the same exposure time, the mean scores of readibility were mostly higher in the digitized images. As the exposure time was increased, the digital images were superior to radiographs in readability. 4. As the size of lesion was changed, the digital images were superior to radiographs in detecting small lesion. 5. The coefficient of variation of mean score has no significant difference between digital images and radiographs.

  • PDF