• Title/Summary/Keyword: Bispectral Index

Search Result 34, Processing Time 0.034 seconds

THE USE OF BISPECTRAL ANALYSIS AND HEMODYNAMIC MONITORING IN PATIENTS UNDERGOING INTRAVENOUS SEDATION FOR MINOR ORAL SURGERY (구강악안면외과 소수술시 정맥 의식하 진정법에서의 Bispectral Index and Hemodynamics monitoring을 이용한 진정 깊이에 관한 연구)

  • Shin, Jung-Sub;Min, Hyun-Gi;Lee, Ju-Hyon;Lee, Dong-Hyun;Kim, Myung-Rae;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.567-571
    • /
    • 2008
  • Purpose: The purpose was to assess the usefulness of midazolam in patients undergoing minor oral surgery under conscious sedation. Materials and methods: Bispectral index was examined in 20 patients receiving oral minor surgery with conscious sedation supplemented with local anesthesia. All patients included were ASA I and had no contraindications to the study medications. The patients were escorted to the day surgery operation room where, before the commencement of the sedation and surgical procedures, routine monitoring was applied, including the noninvasive monitoring of arterial blood pressure, arterial oxygen saturation, and 3-lead electrocardiogram (Electrocardiogram). Bispectral index electrodes were applied on the frontotemporal region after cleansing the skin with alcohol. Bispectral index was calculated with the Electrocardiogram monitor (A-2000; Aspect Co.). Midazolam was then titrated (initially 3mg wait 2min and 2mg). Vital sign and Bispectral index checked every 5 minute until the end of the procedure. The results were then compared. Results: The Bispectral index index values throughout the sedation study period alter many level. The index was dropped at 5 minutes after administration, but raised at injection and odontomy procedure. During the operation, mean Bispectral index index was higher than conscious sedation index range($60{\sim}80$). The amnesic effect was shown 17 cases out of 20 cases(85%). Conclusion: Conscious sedation technique using midazolma is a safe and effective method of controlling behavior in oral and maxillofacial surgery.

Changes in bispectral index score and cardiorespiratory function under constant rate infusion with alfaxalone in dogs

  • Yun, Sungho;Kwon, Young-Sam
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.3
    • /
    • pp.133-137
    • /
    • 2016
  • Changes in the cardiovascular and bispectral index score were evaluated in dogs subjected to constant rate infusion (CRI) with alfaxalone. Fifteen dogs were assigned to three groups of 5. Groups and doses of alfaxalone were as follows: group 1, 3 mg/kg for induction and 6 mg/kg/h for CRI; group 2, 3 mg/kg for induction and 8 mg/kg/h for CRI; and group 3, 3 mg/kg for induction and 10 mg/kg/h for CRI. CRI was maintained for 1 h. Respiratory rates and blood pressures showed minimal changes; however, mild tachycardia and mild hypoxemia occurred, especially in group 3. There were some disparities between bispectral index score, electromyography and pedal withdrawal reflex test when measuring anesthetic depth. Additional premedications and/or analgesic agents would be helpful to avoid adverse effects of alfaxalone and provide improved cardiopulmonary functions.

Observed Data Oriented Bispectral Estimation of Stationary Non-Gaussian Random Signals - Automatic Determination of Smoothing Bandwidth of Bispectral Windows

  • Sasaki, K.;Shirakata, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.502-507
    • /
    • 2003
  • Toward the development of practical methods for observed data oriented bispectral estimation, an automatic means for determining the smoothing bandwidth of bispectral windows is proposed, that can also provide an associated optimum bispectral estimate of stationary non-Gaussian signals, systematically only from an observed time series datum of finite length. For the conventional non-parametric bispectral estimation, the MSE (mean squared error) of the normalized estimate is reviewed under a certain mixing condition and sufficient data length, mainly from the viewpoint of the inverse relation between its bias and variance with respect to the smoothing bandwidth. Based on the fundamental relation, a systematic method not only for determining the bandwidth, but also for obtaining the optimum bispectral estimate is presented by newly introducing a MSE evaluation index of the estimate only from an observed time series datum of finite length. The effectiveness and fundamental features of the proposed method are illustrated by the basic results of numerical experiments.

  • PDF

Relationship between Bispectral Index, Sedation Score and Plasma Concentration, during Midazolam Sedation (Midazolam을 이용한 진정법 시 Bispectral Index, 진정점수, 그리고 midazolam의 혈중 농도 사이의 관계)

  • Park, Eun-Jin;Park, Chang-Joo;Yum, Kwang-Won;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.1 no.1 s.1
    • /
    • pp.21-25
    • /
    • 2001
  • 연구배경: 임상적으로 진정법을 시행할 경우 뇌의 상태에 대한 접근은 매우 중요하다. 환자의 뇌에 대한 마취제의 영향을 측정하기 위해 개발된 Bispectral Index (BIS)는 환자의 진정을 방해하지 않고 객관적인 진정정도를 평가할 수 있다. 그러나 이는 항상 진정 깊이의 임상적인 척도와는 일치하지 않는다. 이번 연구에서는 진정법 시행시 환자의 진정 정도를 측정하기 위한 BIS의 유용성을 검증하기 위하여 BIS, 진정점수, 그리고 midazolam의 혈중 농도와의 관계를 연구하였다. 방법: 25명의 건강한 성인 지원자들을 대상으로 무의식을 유도하기 위하여 midazolam 0.08 mg/kg을 정맥으로 주입하였으며 환자의 의식 상태를 진정 회복 시까지 관하였다. BIS와 진정점수는 진정 전과, midazolam 투여 후 10, 20, 30분 간격으로 측정하였다. Midazolam의 혈중 농도는 주입 후 10분 경과 후에 정맥혈 채취 후 HPLC를 이용하여 측정하였다. BIS는 BISTM monitor (Aspect Medical Systems, USA)으로 측정하였으며 또한 진정 정도는 진정 점수로도 평가하였다. 결과: BIS 수치는 진정점수와 유의한 상관관계를 보였다(r = 0.676, p < 0.05). 혈중 midazolam 농도가 감소함에 따라 혈중 농도는 진정점수와 유의한 상관관계를 보였다(r = -0.656). Midazolam 투여 후 10분에서 BIS 수치와 midazolam의 혈중 농도는 유의한 상관관계를 보이지 않았지만(r =0.467) 진정 후 수치는 진정 전 수치와 명확히 구분되었다. 결론: BIS는 환자의 수면상태의 효과적인 척도로 알려져 있으며 진정점수와도 높은 상관관계를 보였다. 그러나 항상 진정 깊이를 나타내는 임상적인 척도와는 일치하지 않았다. 그러므로 진정법 시행동안 BIS 만을 사용하는 것은 더욱 많은 주의가 필요하며 매 주어진 시간마다 다양한 진정 점수 측정방법으로 환자의 의식을 감시하는 것이 추천된다.

  • PDF

RELATIONSHIP BETWEEN BISPECTRAL INDEX (BIS), SEDATION SCORE AND PLASMA CONCENTRATION FOR EVALUATION OF MONITORING EFFECT OF BISPECTRAL INDEX IN MIDAZOLAM SEDATION (Midazolam 진정요법 시 Bispectral index (BIS) Monitoring 효과의 평가를 위한 혈장농도, 진정지수(Sedation Score) 사이의 상관 관계 분석)

  • Park, Eun-Jin;Yum, Kwang-Won;Kim, Eun-Seok;Kim, Hyun-Jeong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.169-172
    • /
    • 2003
  • Purpose : We examined the relationship between BIS, sedation score and plasma midazolam concentration to verify the usefulness of BIS to assess the patient's consciousness during sedation. Patients and Methods : Twenty-five young, healthy adult volunteers participated in this clinical study. Midazolam was administered intravenously up to 0.08 mg/kg to induce unconsciousness and we monitored the patient's physiological and conscious status until complete recovery from sedation. BIS and sedation score were measured before sedation, 10, 20, 30 minutes after midazolam administration. Plasma midazolam concentration was measured 10 minutes after midazolam administration. BIS was measured using A-2000 BISTM monitor (Aspect Medical Systems, USA) and the degree of sedation was evaluated with the sedation score. Results : The BIS score correlated with the sedation score (r = 0.676; P < 0.05). With the decreased plasma midazolam concentration, the correlation was better with sedation score (r = -0.656). Although BIS values did not correlate with calculated plasma concentration of midazolam (r = 0.467) at 10 minutes after midazolam administration, values after sedation were well distinguished from those before sedation. Conclusions : BIS is known for an effective predictor of patient's hypnotic state, and it is correlated with the sedation score. But, it doesn't always coincide with the clinical parameters of depth of sedation. So more attention is needed using BIS only during sedation, and it is advisable that the patient's consciousness is monitored with variable sedation score systems every several minutes.

Effects of Bispectral Index Monitoring Based Sedative Administration on Conscious Sedation, Physiological Stability and Recovery Time in Patients Receiving Endoscopic Submucosal Dissection (이중분광계수 모니터기반 진정제 투여가 내시경 점막하 박리술 환자의 의식하 진정상태, 생리적 안정성 및 회복시간에 미치는 효과)

  • Lee, Mi Jeong;Hwang, Moon Sook;Lim, Hyun Sook;Park, Mi Ok;Huh, Ji Won;Kang, Ki Joo;Kim, Jae Jun;Cho, Myung Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.2
    • /
    • pp.284-295
    • /
    • 2012
  • Purpose: This study was done to clarify effects of bispectral index monitoring sedative administration, compared to MOAA/S (Modified Observer's Assessment of Alertness and Sedation), on conscious sedation, physiological stability and recovery time for patients undergoing endoscopic submucosal dissection. Methods: Participants In this study were patients who underwent endoscopic submucosal dissection because of early gastric cancer. Participants were assigned randomly to an experimental group receiving sedatives based on bispectral index monitoring or to a control group with the MOAA/S instrument. Movements, belching, memory, pain, discomfort, physiological stability (MBP, PR, $SpO_2$), and recovery time were measured during the treatment and recovery. Data were analyzed using Spearman partial correlation coefficient analysis, Mixed model and Wilcoxon rank sum test to determine differences in the parameters. Results: There were no statistically significant differences between the two groups for conscious sedation(movement, belching, memory, pain, or discomfort), physiological stability and recovery time. Conclusion: The results of this study indicate that no differences were found between the two types of monitoring. Thus, use of a bispectral index monitor in clinical practice enabling medical staff to readily assess the conscious sedation of for these patients is expected to be increasingly used as an objective assessment tool for conscious sedation for patient safety.

Comparison between cerebral state index and bispectral index during desflurane anesthesia

  • Cho, Sang-Hyeon;Kim, Sung-Su;Hyun, Dong-Min;Yoon, Hyeong-Suk;Han, Jung-Woo;Kim, Jin Sun
    • Korean Journal of Anesthesiology
    • /
    • v.71 no.6
    • /
    • pp.447-452
    • /
    • 2018
  • Background: Cerebral state index (CSI) is an anesthesia depth monitor alternative to bispectral index (BIS). Published comparative studies have used propofol or sevoflurane. However, studies using desflurane have not been reported yet. Different volatile anesthetics have different electroencephalography signatures. The performance of CSI may be different in desflurane anesthesia. Therefore, the objective of this study was to compare CSI and BIS during desflurane anesthesia. Methods: Thirty-three patients were recruited. Desflurane and remifentanil were used to maintain general anesthesia. BIS and CSI were recorded simultaneously every minute. End-tidal concentration of desflurane was maintained at 4% from the beginning of surgery for 5 minutes. Pairwise data of CSI and BIS were obtained five times at one-minute intervals. This process was repeated in the order of 6%, 8%, and 10%. Results: BIS and CSI were negatively correlated with the end-tidal concentration of desflurane with a similar degree of correlation (correlation coefficient BIS: -0.847, CSI: -0.844). The relationship between CSI and BIS had a good linearity with a slope close to 1 ($R^2=0.905$, slope = 1.01). For the relationship between CSI and BIS at each end-tidal concentration of desflurane, CSI and BIS showed good linearity in 4% and 10% ($R^2=0.559$, 0.540). However, the linearity and slope were decreased in 6% and 8% ($R^2=0.163$, 0.014). Conclusions: CSI showed an equivalent degree of overall performance compared to BIS in desflurane anesthesia. Accounting for previous literature, CSI can be used as a good substitute for BIS regardless of the kind of anesthetics used.

SEDATION EVALUATION USING BIS INDEX ASSESSMENT WITH AND WITHOUT THE ADDED SUBMUCOSAL MIDAZOLAM (점막하 Midazolam의 병용투여 시 BIS 분석을 이용한 진정 평가)

  • Lee, Young-Eun;Park, Mi-Kyung;Kim, So-Young;Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • The aim of this study was to examine the difference of the depth of sedation using the Bispectral index assessment with and without the added submucosal Midazolam to oral Chloral hydrate and Hydroxyzine for pediatric patients. Twenty seven sedation cases were performed in this study Selection criteria included good health(ASA I), 2 to 6 years of age, the need for sedation to receive dental treatment including anesthesia, and restorative procedure over at least two teeth. Patients were randomly classified into one group taking oral Chloral hydrate(60 mg/kg) and Hydroxyzine(1 mg/kg) and the other group recieving Chloral hydrate(60 mg/kg), Hydroxyzine(1 mg/kg) and submucosal Midazolam(0.1 mg/kg). Nitrous Oxide(50%) was used for both group during sedation. Patients were monitored using a pulse oximeter and a Bispectral monitor. A behavior scale was rated as quiet(Q), crying(C), movement(M), or struggling(S) every 2 minutes watching a recorded videotape. Analysis showed a significant difference in mean Bispectral index and SD during sedation across two groups(P<0.001). The group of patients injected with submucosal Midazolam in addition to oral Chloral hydrate and Hydroxyzine showed a lower mean Bispectral index and a narrower SD. PR and SpO2 for both groups remained within the normal values. Submucosal Midazolam improved the sedation quality by deepening sedation depth without compromising safety and enabled the sedation pattern to be kept more stable.

  • PDF