• Title/Summary/Keyword: Biopsy

Search Result 3,021, Processing Time 0.044 seconds

Effect of Route of Preoperative Biopsy on Endoscopic Submucosal Dissection for Patients with Early Gastric Cancer

  • Jiang, Hui;Tu, Hui-Ming;Qiao, Qiao;Xu, Ke-Bin;Li, Jie;Qi, Xiao-Wei;Ge, Xiao-Song
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8917-8921
    • /
    • 2014
  • Objective: To observe and compare the effects of multi-patch biopsy under conventional white light imaging endoscopy (C-WLI) and precise targeted biopsy under magnifying narrow-band imaging endoscopy (M-NBI) on the endoscopic submucosal dissection (ESD) of early gastric cancers and intraepithelial neoplasias. Methods: According to the way of selecting biopsy specimens, patients were divided into C-WLI and M-NBI groups, 20 cases. The ESD operations of the 2 groups were compared quantitively. Results: The mean frequency of biopsy in M-NBI group was ($1.00{\pm}0.00$), obviously lower than in the C-WLI group ($4.78{\pm}1.02$) (P<0.01).The average total number of selected biopsy specimens was also fewer ($1.45{\pm}0.12$ and $7.82{\pm}2.22$, respectively, P<0.01). There was no significant difference in the time of determining excision extension, marking time and the time of specimen excision of 2 groups during the ESD (P>0.05), whereas submucosal injection time, mucosal dissection time, stopping bleeding time, wound processing time in the M-NBI group were significantly shorter than in the C-WLI group (P<0.01). Conclusion: Precise targeted biopsy under M-NBI can obviously shorten the time of ESD operation, with small quantity of tissues but high pathological positive rate.

Comparison between Radiological and Invasive Diagnostic Modalities in Diagnosis of Breast Cancer

  • Onur, Gulcin Ozkan;Tarcan, Ercument;Onur, Asim;Can, Huseyin;Atahan, Murat Kemal;Yigit, Seyran Ceri;Cakalagaoglu, Fulya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.10
    • /
    • pp.4323-4328
    • /
    • 2015
  • Background: Breast cancer is the most common cause of deaths of cancer in women. Nowadays, following completion of imaging methods, mainly fine needle aspiration biopsy (FNAB) and core biopsy methods have been used for establishing cytopathological diagnosis although discussions regarding superiority continue. Materials and Methods: Those with a complaint of "mass in breast" along with those diagnosed to have a mass as a result of routine physical examination among all patients applying to our clinic between 01.01.2009 and 31.12.2011 were retrospectively assessed. Totals of 146 and 64 patients with complete radiological observation who had undergone FNAB and core biopsies, respectively, were evaluated. Postoperative pathological results of patients of both groups receiving surgery were also taken into consideration. All results were compared in terms of false positivity/negativity, sensitivity/specifity, surgery types and distribution of postoperative results with regard to diagnoses along with those of malignant/benign masses with regard to quadrants determined. Results: Diagnostic malignancy power of mammographic BIRADS classification was 87.3%. However, the value was 75% in the core biopsy group. Sensitivity and specifity following comparison of FNAB and postoperative pathology results of those receiving surgery were 85.4% and 92.9% while they were 93.5% and 100% in the core biopsy group. Diagnostic malignancy power, calculated by determining AUC in ROC analysis, of FNAB was 89.1% while that of core biopsy was 96.7%. Conclusions: It was shown that core biopsy is superior to FNAB in terms of sensitivity, specificity and accurate histopathological classification. However; quick, cheap and basic diagnosis by means of FNAB should not be ignored. Sensitivity of FNAB is rather high in experienced hands and furthermore it would be expected to be lower than with core biopsy.

Efficacy of Using Sequential Primary Circulating Prostate Cell Detection for Initial Prostate Biopsy in Men Suspected of Prostate Cancer

  • Murray, Nigel P;Reyes, Eduardo;Fuentealba, Cynthia;Jacob, Omar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3385-3390
    • /
    • 2016
  • Background: Sequential use of circulating prostate cell (CPC) detection has been reported to potentially decrease the number of unnecessary prostate biopsies in men suspected of prostate cancer. In order to determine the real world effectiveness of the test, we present a prospective study of men referred to two hospitals from primary care physicians, one using CPC detection to determine the necessity of prostate biopsy the other not doing so. Materials and Methods: Men with a suspicion of prostate cancer because of elevated PSA >4.0ng/ml or abnormal DRE were referred to Hospitals A or B. In Hospital A all underwent 12 core TRUS biopsy, in Hospital B only men CPC (+), with mononuclear cells obtained by differential gel centrifugation identified using double immunomarking with anti-PSA and anti-P504S, were recommended to undergo TRUS biopsy. Biopsies were classifed as cancer or no-cancer. Diagnostic yields were calculated, including the number of posible biopsies that could be avoided and the number of clinically significant cancers that would be missed. Results: Totals of 649 men attended Hospital A, and 552 men attended Hospital B; there were no significant differences in age or serum PSA levels. In Hospital A, 228 (35.1%) men had prostate cancer detected, CPC detection had a sensitivity of 80.7%, a specificity of 88.6%, and a negative predictive value of 89.5%. Some 39/44 men CPC negative with a positive biopsy had low grade small volume tumors. In Hospital B, 316 (57.2%) underwent biopsy. There were no significant differences between populations in terms of CPC and biopsy results. The reduction in the number of biopsies was 40%. Conclusions: The use of sequential CPC testing in the real world gives a clear decision structure for patient management and can reduce the number of biopsies considerably.

Performance Indices of Needle Biopsy Procedures for the Assessment of Screen Detected Abnormalities in Services Accredited by BreastScreen Australia

  • Farshid, Gelareh;Sullivan, Thomas;Jones, Simeon;Roder, David
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10665-10673
    • /
    • 2015
  • Background: We wished to analyse patterns of use of needle biopsy procedures by BreastScreen Australia (BSA) accredited programs to identify areas for improvement. Design: BSA services provided anonymous data regarding percutaneous needle biopsy of screen detected lesions assessed between 2005-2009. Results: 12 services, from 5 of 7 Australian states and territories provided data for 18212 lesions biopsied. Preoperative diagnosis rates were 96.84% for lesion other than microcalcification (LOTM) and 93.21% for microcalcifications. At surgery 97.9% impalpable lesions were removed at the first procedure. Of 11548 Microcalcification (LOTM) biopsied, 46.9% were malignant. The final diagnosis was reached by conventional core biopsy (CCB) in 72.46%, FNAB in 21.33%, VACB in 1.69% and open biopsy in 4.52% of lesions. FNA is being limited to LOTM with benign imaging After FNAB, core biopsy was required for 38% of LOTM. In LOTM the mean false positive rate (FPR) was 0.36% for FNAB, 0.06% for NCB and 0% for VACB. Diagnostic accuracy was 72.75% for FNAB and 92.1% for core biopsies combined. Of 6441 microcalcifications biopsied 2305 (35.8%) were malignant. Microcalcifications are being assessed primarily by NCB but 6.57% underwent FNAB, 45.6% of which required NCB. False positive diagnoses were rare. FNR was 5% for NCB and 1.53% for VACB. Diagnostic accuracy was 73.52% for FNAB, 86.29% for NCB and 88.63% for VACB. Only 8 of 12 services had access to VACB facilities. Conclusions: BSA services are selecting lesions effectively for biopsy and are achieving high preoperative diagnosis rates. Gaps in the present accreditation standards require further consideration.

The Diagnostic Accuracy of Endoscopic Biopsy for Gastric Dysplasia

  • Lee, Sung-Bae;Kang, Hye-Yun;Kim, Kwang-Il;Ahn, Dae-Ho
    • Journal of Gastric Cancer
    • /
    • v.10 no.4
    • /
    • pp.175-181
    • /
    • 2010
  • Purpose: There is controversy over the treatment for low grade dysplasia, while resection is recommended for high grade dysplasia. But the concordance of the grade of dysplasia between pre- and post-resection is low because of sampling errors with endoscopic biopsy. We attempted to establish a clearer direction for the treatment of dysplasia by clarifying the discrepancy between the pre- and postresection diagnoses. Materials and Methods: We performed a retrospective review of 126 patients who had undergone resection with the diagnosis of dysplasia on biopsy at Bundang CHA Hospital from 1999 to 2009. Results: Seventy patients were diagnosed with low grade dysplasia and 56 patients were diagnosed with high grade dysplasia. Among the 33 patients who received gastrectomy with lymph node dissec-tion, 30 patients were revealed to have invasive cancers and 4 patients showed lymph node metastasis. Discordance between the diagnoses from biopsy and resection occurred in 55 patients (44%). There was no correlation on the comparative analysis between the size, location or gross type of lesion and the grade of dysplasia. Conclusions: The rate of discordance between the diagnoses of endoscopic biopsy and the post resection pathologic report was as high as 44%. Endoscopic mucosal resection was not sufficient for some patients who were diagnosed with dysplasia on biopsy due to the presence of lymph node metastasis. It is necessary to be prudent when determining the follow-up and treatment based solely on the result of the biopsy.

Operative Lung Biopsy in Patients with Findings of Diffuse Infiltrative Lung on Chest X-ray (흉부 단순 촬영상 전반적 폐 침윤을 보이는 환자에서 시행한 수술적 폐 생검)

  • Jin, Ung;Yoon, Jeong-Seob;Kim, Chi-Kyung;Kwack, Moon-Seob
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.2
    • /
    • pp.159-163
    • /
    • 2000
  • The patient with findings of diffuse infiltrative lung on chest X-ray has various causes; therefore, the prognosis is different and the treatment should be changed according to the cause. We are trying to identify the meaning of operative lung biopsy and to 11nd a more accurate and effective procedure. We reviewed 46 medical records of patients with the findings of diffuse infiltrative lung on chest X-ray who had undergone operative lung biopsy or biopsies for 8 years. The open lung biopsy were done in 22 cases(47.8%) and thoracoscopic lung biopsy in 24 cases(52.2%). There is no significant difference in the rate of diagnosis(p=0.452) and the incidence of complications(p=0.155) between these groups. The number of cases with more than two biopsies are 9(19.6%) and that of one biopsy are 37(80.4%). There are no statistical difference in the rate of diagnosis(p=0.928) and the incidence of complications(p=0.125). The postoperative complications occurred in 8 cases,7 cases of air leak more than 7 days and 1 case of respiratory insufficiency. In the diagnosis and treatment of the patients with findings of infiltrative lung on chest X-ray, the operative lung biopsy is the very necessary course, and shows satisfactory rate of diagnosis with negligible complications.

  • PDF

Reported Lung Adenocarcinoma with Idiopathic Pulmonary Fibrosis after Open Lung Biopsy (특발성 폐 섬유화증 환자에서 폐 생검후 발견된 폐 선암 치험 1예)

  • 최창우;허균;이재욱;원용순;고은석;신화균
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1032-1035
    • /
    • 2004
  • The specific diagnosis in diffuse interstitial lung disease may be obtained through open lung biopsy. Diffuse interstitial lung disease is often associated with lung cancer. We report one case of lung adenocarcinoma with idiopathic pulmonary fibrosis in whom previous open lung biopsy had been performed. We need general concepts about sites of open lung biopsy in these patients. Therefore, we report this case and document other references.

Apperance of Normal Sperm Parameters with Medical Testicular Stimulation and Repeat Vasovasostomy in the Patient Showing Spermatogenic Arrest Following Vasovasostomy (정관복원술 실패 후 정세포 발육정지의 소견을 보인 경우를 약물적 치료와 재수술을 시행하여 정상 정액을 얻은 환자에서 논의할 사항들)

  • Kim, Young-Chan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.23 no.1
    • /
    • pp.7-9
    • /
    • 1996
  • Here, A forty year old patient is presented, showing azoospermia following vasovasostomy. The bilateral testicular biopsies were performed to confirm whether ductal obstruction due to vasovasostomy or testicular failure existed. The finding of biopsy was spermatogenic arrest. After completion of medical testicular stimulation with clomiphene citrate and pentoxifilline for 3 months, repeat vasovasostomy was performed. Semenanaylsis revealed normal sperm parameters after operation. Necessity of testicular biopsy before deciding repeat vasovasostomy, accuracy of testicular biopsy, efficacy of testicular stimulation in the patient with spermatogenic arrest and effect of testicular biopsy on testicular fuction are discussed.

  • PDF

Role of Liquid Biopsies in Colorectal Cancer (대장암에서 액체 생검의 역할)

  • Kim, Sang Hyun;Keum, Bora
    • Journal of Digestive Cancer Reports
    • /
    • v.8 no.1
    • /
    • pp.56-60
    • /
    • 2020
  • In recent years, liquid biopsy has received immense attention. Liquid biopsy is a minimally invasive method used for obtaining biological fluids including urine, pleural fluid and, mostly, peripheral blood. Liquid biopsy involves various targets including circulating tumors cells (CTCs), circulating cell-free tumor DNA (ctDNA), and microRNA (miRNA). Colorectal cancer (CRC), like other solid tumors, shed tumor cells into the bloodstream. Analysis of these CTCs, as well as ctDNA is the primary objective of the liquid biopsy. Evaluation of CTC or ctDNA offers information about early tumor release, development of tumor metastasis and also about mechanisms involved in tumor resistance to treatment.

Characteristics of Needle Insertion Performance of Automated Biopsy Device for Robotic Needle Insertion Type Intervention: Insertion Depth and Accuracy (로봇 자동화 바늘삽입형 중재시술을 위한 자동화 생검장치의 바늘삽입 특성: 바늘삽입 깊이 및 삽입정확도)

  • Moon, Youngjin;Choi, Jaesoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.565-570
    • /
    • 2016
  • This paper presents the characteristics related to needle insertion of a robotic device for the automated biopsy procedure. The automated biopsy device, a main component of the robotic needle insertion type intervention system, allows performance of the full biopsy procedure, except for anesthesia, without direct handling of a radiologist or a tele-operated control. In this study, the needle length parameters corresponding to various insertion depths and precision for needle insertion of the automated biopsy device, are discussed. There were two combinations of needle length parameters for appropriate needle insertion and motion capture-based measurement was performed; 0.156 mm error for the 90 mm length commanded insertion displacement was measured. The pre-defined goal is a maximum 1 mm error and thus our measured error is within the acceptable range. In the repeatability check, it was also shown that the device can implement a highly accurate insertion.