Adaptive Hybrid Fingerprint Matching Method Based on Minutiae and Filterbank (특징점과 필터뱅크에 기반한 적응적 혼합형 지문정합 방법)

  • 정석재;박상현;문성림;김동윤
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.7
    • /
    • pp.959-967
    • /
    • 2004
  • Jain et al. proposed the hybrid matching method which was combined the minutia-based matching method and the filter-bank based matching method. And, their experimental results proved the hybrid matching method was more effective than each of them. However, this hybrid method cannot utilize each peculiar advantage of two methods. The reason is that it gets the matching score by simply summing up each weighted matching score after executing two methods individually. In this paper, we propose new hybrid matching method. It mixes two matching methods during the feature extraction process. This new hybrid method has lower ERR than the filter-bank based method and higher ERR than the minutia-based method. So, we propose the adaptive hybrid scoring method, which selects the matching score in order to preserve the characteristics of two matching methods. Using this method, we can get lower ERR than the hybrid matcher by Jain et al. Experimental results indicate that the proposed methods can improve the matching performance up to about 1% in ERR.

Development of a Knee Exoskeleton for Rehabilitation Based EMG and IMU Sensor Feedback (단계별 무릎 재활을 위한 근전도 및 관성센서 피드백 기반 외골격 시스템 개발)

  • Kim, Jong Un;Kim, Ga Eul;Ji, Yeong Beom;Lee, A Ram;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.223-229
    • /
    • 2019
  • The number of knee-related disease patients and knee joint surgeries is steadily increasing every year, and for knee rehabilitation training for these knee joint patients, it is necessary to strengthen the muscle of vastus medialis and quadriceps femoris. However, because of the cost and time-consuming difficulties of receiving regular hospital treatment in the course of knee rehabilitation, we developed knee exoskeleton using rapid prototype for knee rehabilitation with feedback from the electromyogram (EMG) and inertia motion unit (IMU) sensor. The modules was built on the basis of EMG and an IMU sensor applied complementary filter, measuring muscle activity in the vastus medialis and the range of joint operation of the knee, and then performing the game based on this measurement. The IMU sensor performed up to 97.2% accuracy in experiments with ten subjects. The functional game contents consisted of an exergaming platform based on EMG and IMU for the real-time monitoring and performance assessment of personalized isometric and isotonic exercises. This study combined EMG and IMU-based functional game with knee rehabilitation training to enable voluntary rehabilitation training by providing immediate feedback to patients through biometric information, thereby enhancing muscle strength efficiency of rehabilitation.

A Flexible Model-Based Face Region Detection Method (유연한 모델 기반의 얼굴 영역 검출 방법)

  • Jang, Seok-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.251-256
    • /
    • 2021
  • Unlike general cameras, a high-speed camera capable of capturing a large number of frames per second can enable the advancement of some image processing technologies that have been limited so far. This paper proposes a method of removing undesirable noise from an high-speed input color image, and then detecting a human face from the noise-free image. In this paper, noise pixels included in the ultrafast input image are first removed by applying a bidirectional filter. Then, using RetinaFace, a region representing the person's personal information is robustly detected from the image where noise was removed. The experimental results show that the described algorithm removes noise from the input image and then robustly detects a human face using the generated model. The model-based face-detection method presented in this paper is expected to be used as basic technology for many practical application fields related to image processing and pattern recognition, such as indoor and outdoor building monitoring, door opening and closing management, and mobile biometric authentication.

Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera

  • Cho, Kyuyeon;Lim, Dong Hui;Yang, Chan-min;Chung, Eui-Sang;Chung, Tae-Young
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.497-505
    • /
    • 2018
  • Purpose: To evaluate and compare published methods of calculating intraocular lens (IOL) power following myopic laser refractive surgery. Methods: We performed a retrospective review of the medical records of 69 patients (69 eyes) who had undergone myopic laser refractive surgery previously and subsequently underwent cataract surgery at Samsung Medical Center in Seoul, South Korea from January 2010 to June 2016. None of the patients had pre-refractive surgery biometric data available. The Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug total corneal refractive power (TCRP) 3 and 4 mm (SRK-T and Haigis), Scheimpflug true net power, and Scheimpflug true refractive power (TRP) 3 mm, 4 mm, and 5 mm (SRK-T and Haigis) methods were employed. IOL power required for target refraction was back-calculated using stable post-cataract surgery manifest refraction, and implanted IOL power and formula accuracy were subsequently compared among calculation methods. Results: Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug TCRP 4 mm (Haigis), Scheimpflug true net power 4 mm (Haigis), and Scheimpflug TRP 4 mm (Haigis) formulae showed high predictability, with mean arithmetic prediction errors and standard deviations of $-0.25{\pm}0.59$, $-0.05{\pm}1.19$, $0.00{\pm}0.88$, $-0.26{\pm}1.17$, $0.00{\pm}1.09$, $-0.71{\pm}1.20$, and $0.03{\pm}1.25$ diopters, respectively. Conclusions: Visual outcomes within 1.0 diopter of target refraction were achieved in 85% of eyes using the calculation methods listed above. Haigis-L, Barrett True-K (no history), and Scheimpflug TCRP 4 mm (Haigis) and TRP 4 mm (Haigis) methods showed comparably low prediction errors, despite the absence of historical patient information.

Handwritten One-time Password Authentication System Based On Deep Learning (심층 학습 기반의 수기 일회성 암호 인증 시스템)

  • Li, Zhun;Lee, HyeYoung;Lee, Youngjun;Yoon, Sooji;Bae, Byeongil;Choi, Ho-Jin
    • Journal of Internet Computing and Services
    • /
    • v.20 no.1
    • /
    • pp.25-37
    • /
    • 2019
  • Inspired by the rapid development of deep learning and online biometrics-based authentication, we propose a handwritten one-time password authentication system which employs deep learning-based handwriting recognition and writer verification techniques. We design a convolutional neural network to recognize handwritten digits and a Siamese network to compute the similarity between the input handwriting and the genuine user's handwriting. We propose the first application of the second edition of NIST Special Database 19 for a writer verification task. Our system achieves 98.58% accuracy in the handwriting recognition task, and about 93% accuracy in the writer verification task based on four input images. We believe the proposed handwriting-based biometric technique has potential for use in a variety of online authentication services under the FIDO framework.

Evaluation of a Smart After-Care Program for Patients with Lung Cancer: A Prospective, Single-Arm Pilot Study

  • Yang, Hee Chul;Chung, Seung Hyun;Yoo, Ji Sung;Park, Boram;Kim, Moon Soo;Lee, Jong Mog
    • Journal of Chest Surgery
    • /
    • v.55 no.2
    • /
    • pp.108-117
    • /
    • 2022
  • Background: The efficacy of telemedicine among cancer survivors is uncertain. The Smart After-Care Program (SAP), which is an interactive, smartphone-based remote health monitoring system, was developed to help patients manage their health after leaving the hospital. This study was designed to evaluate the efficacy of our remote health care program for lung cancer patients. Methods: We enrolled 50 patients with lung cancer. Self-monitoring devices were supplied to all patients, who were instructed to enter their daily vital signs and subjective symptoms to the Smart After-Care app. The app also provided information about rehabilitation exercises and a healthy diet for lung cancer patients. All patients received health counseling via telephone once a week and visited an outpatient clinic during weeks 6 and 12 to assess satisfaction with the SAP and changes in quality of life and physical performance. Results: Overall satisfaction with the SAP was very high (very good, 61.9%; good, 26.2%). In the multivariate analysis to identify factors affecting satisfaction, the distance between the patient's residence and the hospital was the only significant independent factor (p=0.013). Quality of life improved along all functional scales (p<0.05). Muscle strength significantly improved in the lower limbs (p=0.012). Two-minute walk distance also significantly improved (p=0.028). Conclusion: This study demonstrated that the SAP was acceptable for and supportive of patients with reduced pulmonary function after lung cancer treatment. The SAP was found to be particularly useful for patients living far from the hospital.

The Interface between Wearable Devices and Metaverse: A Study on Soccer Game Character Ability Mapping using Mi Band (웨어러블 디바이스와 메타버스의 접점: 미밴드를 이용한 축구 게임 캐릭터 능력치 매핑 연구)

  • Hyun-Su Kim;Mi-Kyeong Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1345-1352
    • /
    • 2023
  • With the development of virtual reality (VR) and blockchain technology, Metaverse is being used in various fields such as games, education, and social networking. At the same time, shipments of wearable devices such as smartwatches are growing every year, becoming more and more integrated into people's daily lives. This study presents a new possibility of reflecting the user's body signals measured through the combination of the two phenomena in the metaverse character. Various biometric information such as the user's heart rate and amount of exercise collected through the smartwatch are reflected on the character in the metaverse, allowing the user's physical condition to be reflected in the virtual world. Through this, Metaverse is expected to provide a new experience that can be called 'extended reality' beyond simple virtual reality, improve user's satisfaction with Metaverse, and suggest a direction for the development of smartwatches.

Biological aspects of Oreochromis niloticus (Linnaeus, 1758) in Geray Reservoir (Ethiopia) for effective sustainable fisheries

  • Solomon Wagaw;Ayalew Sisay;Asnaku Bazezew;Yirga Enawgaw;Assefa Wosnie
    • Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.100-110
    • /
    • 2024
  • Biometric evaluation and reproductive biology of Oreochromis niloticus were studied from Geray Reservoir. Between November 2021 and August 2022, 316 O. niloticus specimens were collected from this reservoir. The observed male to female sex ratio was 1:1.14, which was statistically insignificant compared with the hypothetical 1:1 sex ratio (X2 = 1.27, p > 0.05). The length-weight relationship was curvilinear with allometric growth (b < 3) and statistically significant from the expected isometric growth pattern (b = 3). The regression equation for females was TW = 0.0264TL2.72 (r2 = 0.90, n = 168), males (TW = 0.0183TL2.79, r2 = 0.93, n = 148), and combined sexes (TW = 0.0229TL2.76, r2 = 0.91, n = 316). Gonadosomatic index (GSI) ranged from 0.8 to 1.4 (males) and 1.8 to 4.9 (females). The breeding season lasted from March to June, with a GSI peak in April. Fecundity ranged from 279 to 1,528 eggs./fish, with a mean of 1,025 eggs./fish. The correlation between absolute fecundity and length was more significant (F = 0.76TL2.8, R2 = 0.94, p < 0.05) than with weight (F = 17.683TW0.71, R2 = 0.92, p < 0.05). This study provides basic information on the biology of O. niloticus in the Geray Reservoir for future fishery management tools for the conservation and utilization of this valuable freshwater fish.

Secure Management Method for Private Key using Smartphon's Information (스마트폰 고유정보를 이용한 안전한 개인키 관리 방안)

  • Kim, Seon-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.90-96
    • /
    • 2016
  • The 3390 million people, around 83% of the adult population in Korea use smartphone. Although the safety problem of the certificate has been occurred continuously, most of these users use the certificate. These safety issues as a solution to 'The owner of a mobile phone using SMS authentication technology', 'Biometric authentication', etc are being proposed. but, a secure and reliable authentication scheme has not been proposed for replace the certificate yet. and there are many attacks to steal the certificate and private key. For these reasons, security experts recommend to store the certificate and private key on usb flash drive, security tokens, smartphone. but smartphones are easily infected malware, an attacker can steal certificate and private key by malicious code. If an attacker snatchs the certificate, the private key file, and the password for the private key password, he can always act as valid user. In this paper, we proposed a safe way to keep the private key on smartphone using smartphone's unique information and user password. If an attacker knows the user password, the certificate and the private key, he can not know the smart phone's unique information, so it is impossible to use the encrypted private key. Therefore smartphone user use IT service safely.

A study on the FIDO authentication system using OpenSource (OpenSource를 이용한 FIDO 인증 시스템에 관한 연구)

  • Lee, Hyun-Jo;Cho, Han-Jin;Kim, Yong-Ki;Chae, Cheol-Joo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.19-25
    • /
    • 2020
  • As the number of mobile device users increases, research on various user authentication methods has been actively conducted to protect sensitive personal information. Knowledge-based techniques have the disadvantage that security is deteriorated due to easy exposure of authentication means, and proprietary-based techniques have a problem of increasing construction cost and low user convenience to use the service. In order to solve this problem, a FIDO authentication system, which is a user authentication method using a smart device, has been proposed. Since the FIDO authentication system performs authentication based on the biometric information of the user, the risk of the authentication means being leaked is low, and since the authentication information is stored in the user's smart device, the user information due to server hacking is solved. Through this, it is possible to select and utilize user authentication technology suitable for the security level of the service. In this paper, we introduce the FIDO authentication system, explain the main parts required for FIDO UAF client-server development, and show examples of implementation using UAF open source provided by ebay.