• Title/Summary/Keyword: Biomedical polymer

Search Result 318, Processing Time 0.029 seconds

Development and Characterization of the Asphalt Binder with Low-heat and Crosslink Structured Additive

  • Eun Kyoung Lee;You Kyoung Kim
    • Elastomers and Composites
    • /
    • v.57 no.4
    • /
    • pp.222-230
    • /
    • 2022
  • In this study, a low-heat additive with a crosslink structure was dispersed in asphalt to simultaneously lower the production temperature of, and to modify the asphalt binder. This low-heat additive was prepared by different feeding ratios of styrene-butadiene-styrene (SBS) and polyvinylchloride (PVC) as polymer modifiers, and ZnO as a crosslinking agent. In order to confirm the crosslinking density and compatibility of the crosslink structured low-heat additive with asphalt, surface free energy, swelling ratio, differential scanning calorimetry (DSC), and scanning electron microscope (SEM) parameters were carefully investigated to examine this relationship, and the role of the crosslink structured low-heat additive. In addition, by measuring the penetration and softening point of the asphalt binder, it was confirmed that it corresponds to PG 64-22. With increasing ZnO in the crosslink structured low-heat additive, the swelling ratio decreased, leading to an increase in crosslinking density. The crosslink structured low-heat additive and the asphalt binder were found to be compatible with each other by DSC and SEM analysis.

Thermosensitive Hydrogels Based on IPNs and Emulsion Blends of Poly (N-isopropylacrylamide) and Polyurethane

  • Cho, Sung-Man;Kim, Byung-Kyu
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.374-374
    • /
    • 2006
  • Poly (N-isopropylacrylamide) (PNIPAAm) shows a lower critical solution temperature (LCST) at $32^{\circ}C$. Consequently, its thermosensitivity has extensively been investigated in coating materials as well as biomedical and agricultural industry. However, mechanical properties of the swollen gels are generally poor and reinforcement is often desired. A series of interpenetrating polymer networks (IPNs) and emulsion blends hydrogels of polyurethane (PU) and PNIPAAm were prepared in order to overcome the shortcomings of a normal PNIPAAm hydrogels. Regarding the mechanical reinforcement of swollen gel, a significant increase in compression and tensile properties has been obtained by incorporating PU.

  • PDF

Preparation and Properties of PEG Modified PNVP Hydrogel

  • Son, Young-Kyo;Kim, Ji-Heung;Jeon, Young-Sil;Chung, Dong-June
    • Macromolecular Research
    • /
    • v.15 no.6
    • /
    • pp.527-532
    • /
    • 2007
  • Polymer hydrogel has attracted considerable interest as a soft material which is finding expanding applications in pharmaceutics and various biomedical fields. In this work, modified PNVP hydrogels were synthesized by crosslinking polymerization of NVP monomer in the presence of PEG macromer with a methoxy end. The effect of the tethered PEG chain on the properties of the hydrogel was investigated in terms of its swelling capacity, compression gel strength, and the morphology of the resulting hydrogels. These PEG-modified PNVP hydrogels possessed good biocompatibility and a decreased protein (fibrinogen) adsorption, thereby indicating their potential as novel drug delivery matrices and scaffold for tissue engineering.

THREE-DIMENSIONAL VERIFICATION OF INTRACRANIAL TARGET POINT DEVIATION USING MRI-BASED POLYMER-GEL DOSIMETRY FOR CONVENTIONAL AND FRACTIONATED STEREOTACTIC RADIOSURGERY

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.107-118
    • /
    • 2011
  • Conventional (SRS) and fractionated (FSRS) stereotactic radiosurgery necessarily require stringent overall target point accuracy and precision. We determine three-dimensional intracranial target point deviations (TPDs) in a whole treatment procedure using magnetic resonance image (MRI)-based polymer-gel dosimetry, and suggest a technique for overall system tests. TPDs were measured using a custom-made head phantom and gel dosimetry. We calculated TPDs using a treatment planning system. Then, we compared TPDs using mid bi-plane and three-dimensional volume methods with spherical and elliptical targets to determine their inherent analysis errors; finally, we analyzed regional TPDs using the latter method. Average and maximum additive errors for ellipses were 0.62 and 0.69 mm, respectively. Total displacements were 0.92 ${\pm}$ 0.25 and 0.77 ${\pm}$ 0.15 mm for virtual SRS and FSRS, respectively. Average TPDtotal at peripheral regions was greater than that at central regions for both. Overall system accuracy was similar to that reported previously. Our technique could be used as an overall system accuracy test that considers the real radiation field shape.

Development of micro check valve with polymer MEMS process for medical cerebrospinal fluid (CSF) shunt system (Polymer MEMS 공정을 이용한 의료용 미세 부품 성형 기술 개발)

  • Chang, J.K.;Park, C.Y.;Chung, S.;Kim, J.K.;Park, H.J.;Na, K.H.;Cho, N.S.;Han, D.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.1051-1054
    • /
    • 2000
  • We developed the micro CSF (celebrospinal fluid) shunt valve with surface and bulk micromachining technology in polymer MEMS. This micro CSF shunt valve was formed with four micro check valves to have a membrane connected to the anchor with the four bridges. The up-down movement of the membrane made the CSF on & off and the valve characteristic such as open pressure was controlled by the thickness and shape of the bridge and the membrane. The membrane, anchor and bridge layer were made of the $O_2$ RIE (reactive ion etching) patterned Parylene thin film to be about 5~10 microns in thickness on the silicon wafer. The dimension of the rectangular nozzle is 0.2*0.2 $\textrm{mm}^2$ and the membrane 0.45 mm in diameter. The bridge width is designed variously from 0.04 mm to 0.12 mm to control the valve characteristics. To protect the membrane and bridge in the CSF flow, we developed the packaging system for the CSF micro shunt valve with the deep RIE of the silicon wafer. Using this package, we can control the gap size between the membrane and the nozzle, and protect the bridge not to be broken in the flow. The total dimension of the assembled system is 2.5*2.5 $\textrm{mm}^2$ in square, 0.8 mm in height. We could precisely control the burst pressure and low rate of the valve varing the design parameters, and develop the whole CSF shunt system using this polymer MEMS fabricated CSF shunt valve.

  • PDF

Role of polyethylene glycol (PEG) linkers: trends in antibody conjugation and their pharmacokinetics

  • Kondapa Naidu Bobba;Abhinav Bhise;Subramani Rajkumar;Woonghee Lee;Jeongsoo Yoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.155-164
    • /
    • 2020
  • Polyethylene glycol (PEG) has been the most commonly used polymer for the past few decades in the field of biomedical applications due to its gold standard stealth effect. PEGylation of antibody-drug conjugates, liposomes, peptides, nanoparticles, and proteins is done to improve their pharmaceutical efficacy and pharmacokinetic properties. PEGylation of antibodies with various PEG linkers improves targeting ability by increasing the blood circulation time and thus enhances the biodistribution profiles. It also assists in minimizing the immediate capture by the reticuloendothelial system. In this review, we summarize the effect of PEG linkers in an antibody conjugation and their pharmacokinetics in the field of biomedical imaging.

Swelling Behavior of Biodegradable Crosslinked Gel based on Poly(aspartic acid) and PEG-diepoxide

  • Min, Suk-Kee;Kim, Ji-Heung;Chung, Dong-Jun
    • Macromolecular Research
    • /
    • v.9 no.3
    • /
    • pp.143-149
    • /
    • 2001
  • Poly(aspartic acid), PASP, is a biodegradable, water-soluble polymer and offers a biodegradable alternative to polycarboxylates and other non-degradable water-soluble polymers. PASP one of poly (amino acid)s, possesses carboxylic acid pendant group in its repeating unit, which can be used for various further modification purposes. In this study we prepared high molecular weight polysuccinimide, as the precursor polymer for PASP, by thermal polycondensation ofL-aspartic acid in the presence of phosphoric acid. The polysuccinimide was hydrolyzed with 0.1 N sodium hydroxide, and then acidified to give PASP. High water-absorbent gels were produced by thermal crosslinking of freeze-dried mixture of partially-neutralized PASP and different amount of low moi. wt. PEG-diepoxide compounds in aqueous medium. The swelling behavior of the prepared gels from different size and composition of crosslinking reagent in different media was investigated and the results were discussed. This PASP-based hydrogel materials possessing inherent biodegradability, potential non-toxicity and biocompatibility, is expected to be used as a substrate for various biomedical applications as well as a general purpose super-absorbent polymer.

  • PDF

Bombyx mori Silk Fibroin Films: Preparation, Characterization of Physical and Chemical Properties, Use as Biomaterial

  • Freddi, Giuliano
    • Proceedings of the Korean Society of Sericultural Science Conference
    • /
    • 2003.10a
    • /
    • pp.34-38
    • /
    • 2003
  • The silk fibre Produced by the larvae of the lepidopter of the Bombyx mori species is no doubt one of the most precious raw materials employed in manufacturing textile products. The present report, however, deals with silk not as a traditional textile fibre, but as a starting material fer biomedical applications. In recent years, the unique chemical and mechanical properties of silk have made this protein polymer highly attractive for innovative applications, which mainly focus on the development of devices for biomedical uses. (omitted)

  • PDF

Cellular Interaction of In Situ Chitosan- and Hyaluronic Acid-Based Hydrogel

  • Noh, In-Sup
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.183-183
    • /
    • 2006
  • Hyaluronic acid and chitosan-based poly(ethylene oxide) (HA-PEO and Chitosan-PEO) hydrogels have been employed as unique biomedical polymeric materials with properties such as bioactivity from polysaccharide, biocompatibility of HA and chitosan as well as PEO and control release of bioactive molecules from the hydrogel itself. We here examine in situ hydrogels based on hyaluronic acid and chitosan in terms of their synthesis, mechanical properties, morphologies and in vitro cellular interactions on their surface and inside. In vivo bone regeneration of HA-PEO and Chitosan-PEO hydrogels was compared with in mouse model.

  • PDF