• Title/Summary/Keyword: Biomedical data

Search Result 2,237, Processing Time 0.025 seconds

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Preliminary Study of a New Extracorporeal Membrane Oxygenator Development When Using Pulsatile Flow

  • Lee, Sa-Ram;Lee, Kyung-Soo;Jung, Jae-Hoon;Mun, Cho-Hay;Min, Byoug-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.387-391
    • /
    • 2007
  • An oxygenator is a very important artificial organ and widely used for patients with lung failure or during open heart surgery. Although an oxygenator has been widely studied worldwide to enhance its efficiency, studies on oxygenators, in particular when using a pulsatile blood flow, are domestically limited. Therefore, a new oxygenator was developed in the lab and animal experimental results are described in the paper. The oxygenator is composed of polycarbonate housing and polypropylene hollow fibers. It has a total length of 400 mm and a surface area of $1.7 m^2$. The animal experiment lasted for 4 hours. The blood flow rate was set to 2 L/min and a pulsatile blood pump, T-PLS (Twin-Pulse Life Support), was used. Samples were drawn at the oxygenator's inlet and outlet. The total hemoglobin (Hb), saturation oxygen ($sO_2$), and partial oxygen pressure ($pO_2$), partial $CO_2$ pressure ($pCO_2$), and plasma bicarbonate ion concentration ($HCO_3^-$) were measured. The oxygen and carbon dioxide transfer rates were also calculated based on the experimental data in order to estimate the oxygenator's gas transfer efficiency. The oxygen and carbon dioxide transfer rates were $16.4{\pm}1.58$ and $165.7{\pm}10.96 mL/min$, respectively. The results showed a higher carbon dioxide transfer rate was achieved with the oxygenator. Also, the mean inlet and outlet blood pressures were 162.79 and 137.92 mmHg, respectively. The oxygenator has a low pressure drop between its inlet and outlet. The aim of own preliminary study was to make a new oxygenator and review its performance when applying a pulsatile blood pump thus, confirming the possibility of a new oxygenator suitable for pulsatile flow.

The Association of Serum Ferritin and Metabolic Syndrome and Metabolic Syndrome Score in Korean Adults (대한민국 성인에서 대사증후군 및 대사증후군 구성요소의 증가와 혈청 Ferritin의 관련성)

  • Yoon, Hyun;Go, Jae Seong;Kim, Kang Uk;Lee, Keon Woo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.287-295
    • /
    • 2016
  • This study was conducted to assess the relationship amongst serum ferritin, and metabolic syndrome (MetS) and metabolic syndrome score (MSS) in Korean adults. The data of 16,096 adults (6,840 men as well as 4,916 premenopausal and 4,340 postmenopausal women) aged ${\geq}20years$ in the Korean National Health and Nutrition Examination Survey (KNHANES) between 2010 and 2012 were analyzed. The prevalence rate of MetS was 3,978 (24.7%) (men, 24.6%; premenopausal women, 11.1%; postmenopausal women, 40.3%). The key study results were as follows: First, after the adjustment for relevant variables, the serum ferritin level ($M{\pm}SE$) was significantly higher (p<0.001) in the MetS group (men, $132.25{\pm}1.98ng/mL$; premenopausal women, $39.89{\pm}1.49ng/mL$; postmenopausal women, $73.45{\pm}1.14ng/mL$) than in the non-MetS group (men, $111.08{\pm}1.01ng/mL$; premenopausal women, $32.26{\pm}0.50ng/mL$; postmenopausal women, $63.26{\pm}0.98ng/mL$). Second, the serum ferritin levels increased as MSS increased in all groups (men, premenopausal women, and postmenopausal women) (p<0.001). In conclusion, MetS and MSS increases were positively associated with higher serum ferritin levels.

A Review of the Characteristics of Early Apparatus and Methods for Hemoglobin Estimation (Hemoglobin 평가를 위한 초기 기구의 특성 및 측정법 고찰)

  • Kwon, Young-Il
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.401-410
    • /
    • 2016
  • Since the late 19th century, scientific logic and techniques have been used extensively in the field of clinical pathology, including many laboratory tests utilizing various apparatuses and instruments. Among the techniques to measure hemoglobin, the visual color comparison method was most popular around this time; the specific gravity method and gasometric method were not widely adopted. Instruments that use the visual color comparison method include Gowers' hemoglobinometer, von Fleischl's hemoglobinometer, Dare's hemoglobinometer, Oliver's hemoglobinometer, Haden-Hausser hemoglobinometer, and Spencer Hb meter. Initially, the visual color comparison methods were used to diluate and hemolyze blood with distilled water and then to measure its color. Later, these methods were further developed to measure hemoglobin without dilution, and improved with the formation of acid or alkaline hematin ensuring the stability of color development. Hammerschlag's method as well as the Schmaltz and Peiper's methods were based on specific gravity measurement, but they were not widely used. The gasometric method used the Van Slyke gasometer, indirectly measuring the hemoglobin concentration. This method provides the most accurate results. This survey examined the characteristics and limitations of hemoglobinometers and methods used to measure hemoglobin from the late 19th century to the early-and mid-20th century. Moreover, this study aims to improve the understanding and applicability of the current methods and emerging technologies used in measuring hemoglobin. It is also expected that this investigation is the starting point to promote awareness of the need to organize historical data for a variety of historical relics of the diagnostic laboratory tests.

Evaluation of Pregnancy and Thyroid Function (임신과 갑상선 기능의 평가)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • During early pregnancy, before the development of a functioning thyroid gland, thyroid stimulating hormone (TSH) is a very sensitive marker of thyroid dysfunction during pregnancy. Normal values have been modified during gestation with a downward shift. The fetus is influenced by the TSH supplied by the mother. TSH and free thyroxine (FT4) concentrations vary during pregnancy and conventional units can vary between laboratories. A downward shift of the TSH reference range occurs during pregnancy, with a decrease in both the lower and upper limits of maternal TSH, relative to the typical non-pregnant TSH reference range. Each laboratory produces its own reference TSH and FT4 concentrations because there are many different assays that yield different results in pregnancy. Therefore, automated immunoassays used for serum FT4 analysis are still used widely, but the important considerations discussed above must be noted. The use of population-based, trimester-specific reference ranges remains the best way to handle this issue The slight downward shift in the upper reference range of TSH occurring in the latter first trimester (7~12 weeks) of pregnancy, typically not observed prior to 7 weeks. Their use indicates high or low levels in a quantitative manner independent of the reference ranges. These data highlight the importance of calculating population-based pregnancy-specific thyroid parameter reference intervals. A precision medicine initiative in this area will require the collection and analysis of a large number of genetic, biological, psychosocial, and environmental variables in large cohorts of individuals. Large prospective randomized controlled trials will be needed to resolve these controversies.

Regulatory T Cells Promote Pancreatic Islet Function and Viability via TGF-β1 in vitro and in vivo (조절 T 세포 유래 TGF-β1에 의한 췌장섬세포의 기능 및 활성 증가)

  • Choi, Bongkum;Kim, Sa-Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.304-312
    • /
    • 2018
  • Regulatory T cells (Treg), known as immune-suppressors, may help modulate the immune response. In this study, we investigated the effect of Treg-derived $TGF-{\beta}1$ on pancreatic islet cell function in vitro and in vivo. One hundred eighty IEQ (islet equivalents) of pancreatic islets, the marginal amount to regulate blood glucose level after syngeneic islet transplantation in mouse type 1 diabetes (T1D) model, were co-cultured with $4{\times}10^6$ Treg cells for 48 hours. The changes in $TGF-{\beta}1$, interleukin-6 (IL-6), and insulin secretion levels were measured and analyzed among the Treg-only group, the islet-only group, and the Treg/islet co-cultured group. In the Treg/islet co-cultured group, IL-6 and insulin secretion levels were increased (P<0.0005, P<0.005) and islet viability was improved (P<0.005) compared with the islet-only group. Furthermore, after transplantation, the co-cultured islets regulated blood glucose levels efficiently in the T1D mouse model. These data suggest that Treg could improve islet functions and viability via the $TGF-{\beta}1$ secretion pathway (P<0.05~0.005), thus the use of Treg in islet transplantation should be explored further.

Body Mass Index Compared with Waist Circumference Indicators as a Predictor of Elevated Intraocular Pressure (안압상승의 위험인자로서 체질량지수(BMI)와 허리둘레의 비교)

  • Park, Sang-Shin;Lee, Eun-Hee;Paek, Domyung;Cho, Sung-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.293-297
    • /
    • 2010
  • Purpose: The aim of the current study was to compare body mass index (BMI) with waist circumference (WC) as a predictor of elevated intraocular pressure (IOP). Methods: The subjects were consisted of 458 adults, aged 20 year or above, of one community in Kyunggi-do. Mean IOPs were stratified jointly for BMI and WC tertiles. Multi-variate linear regression analysis was also used to compare between BMI and WC. Results: Although any BMI tertiles were not associated with IOP within each tertile of WC, WC tertiles was significantly related to elevation of IOP within the third BMI tertile (${\geq}24.9kg/m^2$). After adjusting for age and sex, only WC showed significant association with IOP. In additional adjustment for lifestyle variables, both BMI and WC were significantly associated with elevation of IOP. However, the results showed the stronger association of IOP with WC than BMI, whether they were adjusted by age and sex or additionally lifestyle variables. Conclusions: These data showed that BMI and WC were positively associated with IOP. However, WC appeared to be a better indicator for higher IOP than BMI.

Copy Number Deletion Has Little Impact on Gene Expression Levels in Racehorses

  • Park, Kyung-Do;Kim, Hyeongmin;Hwang, Jae Yeon;Lee, Chang-Kyu;Do, Kyoung-Tag;Kim, Heui-Soo;Yang, Young-Mok;Kwon, Young-Jun;Kim, Jaemin;Kim, Hyeon Jeong;Song, Ki-Duk;Oh, Jae-Don;Kim, Heebal;Cho, Byung-Wook;Cho, Seoae;Lee, Hak-Kyo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.9
    • /
    • pp.1345-1354
    • /
    • 2014
  • Copy number variations (CNVs), important genetic factors for study of human diseases, may have as large of an effect on phenotype as do single nucleotide polymorphisms. Indeed, it is widely accepted that CNVs are associated with differential disease susceptibility. However, the relationships between CNVs and gene expression have not been characterized in the horse. In this study, we investigated the effects of copy number deletion in the blood and muscle transcriptomes of Thoroughbred racing horses. We identified a total of 1,246 CNVs of deletion polymorphisms using DNA re-sequencing data from 18 Thoroughbred racing horses. To discover the tendencies between CNV status and gene expression levels, we extracted CNVs of four Thoroughbred racing horses of which RNA sequencing was available. We found that 252 pairs of CNVs and genes were associated in the four horse samples. We did not observe a clear and consistent relationship between the deletion status of CNVs and gene expression levels before and after exercise in blood and muscle. However, we found some pairs of CNVs and associated genes that indicated relationships with gene expression levels: a positive relationship with genes responsible for membrane structure or cytoskeleton and a negative relationship with genes involved in disease. This study will lead to conceptual advances in understanding the relationship between CNVs and global gene expression in the horse.

Dispersion of Particle Pulse in Human Lung Airway (인체기관지내의 입자펄스 확산 실험)

  • 이진원;이동엽;추경호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.511-518
    • /
    • 1998
  • In order to develop the aerosol bolus technique which is thought to be a potential tool for probing geometries or abnormalities of small airways, an experimental system of measuring fast time variations of particle concentration in the inhaled and exhaled breathing air was developed. The system generates monodisperse sebacic acrid particles of 1 micron size and 1.2 of geometric standard deviation in high concentration of $10^8$ particles/cc, delivers a short pulse of particles at the controlled instant during inhalation using a solenoid valve, and measures the fast change of particle concentration in using the laser light scattering. Successful operation of the generator and the measuring system was confirmed by smooth concentration profiles in inhalation. It was also confirmed that maintaining a constant breathing rate is essential to stable outputs and any disturbance in flow rate near the mode (maximum concentration) induces a large number of spurious peaks in the exhalation. Experimental data without strict control of breathing flow rate showed a substantial amount of scatter. The measured results showed an improvement in scatter over the existing results. When compared with theoretical predictions from 1-D convective diffusion equation and other experiments, general characteristics of dispersion for several penetration depths showed a good agreement, but there exists some difference in absolute values, which is attributed to the difference in body conditions. Improvements are needed in the theory, especially in relation to correcting for the effect of breathing flow rate.

  • PDF

A Basic Study on the Design of the Flexible Keel in the Energy-Storage Prosthetic Foot for the Improvement of the Walking Performance of the Below Knee Amputees (하지 절단환자의 보행 능력 향상을 위한 에너지 저장형 의족의 유연 용골 설계를 위한 기초연구)

  • 장태성;이정주;윤용산;임정옥
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.519-530
    • /
    • 1998
  • In this paper, the basic study on the design of the flexible keel of the energy-storage prosthetic foot was performed in order to Improve the walking performance and Increase the activities of the below knee amputees. Based on the analysis of the anthropometric data and the normal gait on two dimensional sagittal plane available In the literature, we presented a model of the basic structure of the flexible keel of the prosthetic foot. The model of the basic structure was composed of the simple beams, and linear rotational spring and damper. Laminated carbon fiber-reinforced composites were selected as the material of the basic structure model of the flexible keel In order to apply the high strength and light weight materials to the basic structure of the flexible keel of the prosthetic foot. The recoverable strain energy In response to the change of beam shape was calculated bur the finite element analysis and it was suggested that the change of beam shape could be the design variable in flexible keel design. The simulation process was systematically designed by using orthogonal array table in order to design the flexible keel structure which could store the more recoverable strain energy. finite element analysis was carried but according to the design of simulations by using the finite element program ABAQUS and the flexible keel structure of the energy-storage prosthetic foot was obtained from the analysis of variance(ANOVA). The dynamic simulation model of the prosthetic walking using the flexible keel structure was made and the dynamic analysis was carried but during one walk cycle. Based on the above results, an effective design process was presented for the development of the prosthetic fool system.

  • PDF