Evaluation of Acoustic, Thermal, and Morphological Properties in the Egg White Phantom

  • Kim, Mi-Seon;Kim, Ju-Young;Moon, Dong-Jun;Noh, Si-Cheol;Choi, Heung-Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권1호
    • /
    • pp.7-15
    • /
    • 2015
  • The egg white phantom is a thermal lesion visualization phantom able to illustrate a thermal lesion. It is often used to evaluate the performance of HIFU and is less expensive than the BSA phantom. This study determined the optimal phantom composition for evaluated therapeutic ultrasound machines by varying the egg white concentration in the egg white phantom and demonstrated its utility as a therapeutic ultrasound phantom. The egg white phantom at varying egg white concentrations (10-40% in 10% intervals) was fabricated, and its thermal properties and acoustic properties were assessed. In addition, the size and shape of the formed lesion were compared between the egg white phantom and bovine liver tissue according to the electrical power. The results showed that 30% egg white phantom was optimal for the performance evaluation due to its thermal and acoustic properties. The generated thermal lesions formed sequentially as a cigar, ellipse, tadpole, and cone shapes according to the electrical power; a similar tendency was observed in the liver tissue. Hence, we conclude that the egg white phantom will prove useful in quantitatively evaluating the thermal effects of therapeutic ultrasound.

초음파 응답특성 분석에 의한 위장 경화 진단시스템의 설계 (Design of Gastrointestinal Diagnosis System based on Ultrasonic Response Characteristics)

  • 임도형;김은근;이균정;박원필;김한성;신태민;최서형;이용흠
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.250-257
    • /
    • 2007
  • Functional gastrointestinal disorders affect millions of people of all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The aim is, therefore, to develop a diagnostic method for the functional gastrointestinal disorders based on quantitative measurement of the rigidity of the gastrointestinal tract well using ultrasound technique. For this purpose, a preliminary ultrasound diagnostic system was developed and verified through phantom tests. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders(Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normalspecimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens $(0.1{\pm}0.0Vp-p)$ (p<0.05). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals nea. to the gastrointestinal tract well for the patient group$(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group$(0.1{\pm}0.2Vp-p)$ (p<0.05). These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.

Design of Optimized Ultrasound Clinical Work-Flow; Usability Perspective

  • Bag, ByungEun;Yoo, SunKook;Jang, WonSeuk
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권1호
    • /
    • pp.40-42
    • /
    • 2015
  • Purpose Usability is an important factor in our life. This paper presents an approach to design the clinical work-flow for ultrasound system. And, we tried to apply this work-flow in diagnosis ultrasound system. Materials and Methods For user learnability, we follow international standard IEC 60601-1-1 and IEC 62366 which describes usability of medical instrument. User requirement are applied by 10 clinicians who are well aware of usability. We considered user environment and designed clinical work-flow into two types: general use and emergency use. The designed clinical work-flow was evaluated by 10 clinicians and results derived from the evaluation were analyzed. Results We could successfully design optimized clinical workflow of ultrasound system. Conclusion This paper suggests usability testing for optimized ultrasound clinical workflow. Using this clinical work flow, users can enhance their clinical performance and reduce operation time.

연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가 (Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images)

  • 이소희;김종운;이수열;류정원;최동혁;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권5호
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

Sensitivity Enhancement of Spirometer Employing Ultrasonic Method

  • Han, Seung-Heon;Kim, Young-Kil
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권6호
    • /
    • pp.351-356
    • /
    • 2005
  • Respiration measurement method using an ultrasound sensor is influenced very little by an error of inertia and pressure. This device measures the amount and flow of respiration using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. This paper examines improving the sensor's sensitivity during transmission and receipt of the signal. Because the measurement must be performed on patients, clinicians need to be sure that it is accurately measuring even very weak breathing.

Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging

  • Nam, Seung Yun;Emelianov, Stanislav Y.
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.151-155
    • /
    • 2014
  • Although various ophthalmic imaging methods, including fundus photography and optical coherence tomography, have been applied for effective diagnosis of ocular diseases with high spatial resolution, most of them are limited by shallow imaging penetration depth and a narrow field of view. Also, many of those imaging modalities are optimized to provide microscopic anatomical information, while functional or cellular information is lacking. Compared to other ocular imaging modalities, photoacoustic imaging can achieve relatively deep penetration depth and provide more detailed functional and cellular data based on photoacoustic signal generation from endogenous contrast agents such as hemoglobin and melanin. In this paper, array-based ultrasound and photoacoustic imaging was demonstrated to visualize pigmentation in the eye as well as overall ocular structure. Fresh porcine eyes were visualized using a real-time ultrasound micro-imaging system and an imaging probe supporting laser pulse delivery. In addition, limited photoacoustic imaging field of view was improved by an imaging probe tilting method, enabling visualization of most regions of the retina covered in the ultrasound imaging.

라플라시안 피라미드 기반 총변동 잡음제거 기법을 이용한 초음파 영상 스펙클 제거 유용성 평가 (Evaluation on the Usefulness of Ultrasound Image Speckle Reduction Using Total Variation Denoising (TVD) Method in Laplacian Pyramid)

  • 문주혜;최동혁;이수열;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권4호
    • /
    • pp.140-146
    • /
    • 2016
  • The ultrasound imaging in medical diagnosis has become a popular modality because of its safe, noninvasive, portable, relatively inexpensive, and provides a real-time image formation. However, usefulness of ultrasound imaging is at times limited due to the presence of signal-dependent noise like as speckle. Therefore, noise reduction is very important, as various types of noise generated limits the effectiveness of medical image diagnosis. This paper introduces a speckle noise reduce algorithm using total variation denoising (TVD) in Laplacian pyramid. With this method, speckle is removed by TVD of bandpass ultrasound images in Laplacian pyramid domain. For TVD in each pyramid layer, a ${\lambda}$ is selected by trial-and-error method. The visual comparison of despeckled 'in vivo' ultrasound images from pancreas shows that the proposed method could effectively preserve edges and detailed structures while thoroughly suppressing speckle. For a Simulated B-mode image, contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were obtained like 4.65 dB and 14.11 dB, respectively. The results show that the proposed method can conduct better than some of the existing methods in terms of the CNR and the SNR.

초음파 치료의 효율성 향상을 위한 초음파 온열 시뮬레이터 개발 (The Development of Ultrasonic Hyperthermia Simulator to Improve the Efficiency of Ultrasonic Therapy)

  • 유우진;노시철;정동환;박재현;최민주;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권5호
    • /
    • pp.418-427
    • /
    • 2009
  • As many people are westernizing their life style and food consumption habits, a number of patients who have malignant tumors which grow very rapidly and hazardously destroy the human body are increasing. Ultrasonic hyperthermia is not only one of the tumor treatment methods which employs the non-radioactive ultrasonic waves to increase the temperature at the tumor region up to $40\sim45^{\circ}C$ to destroy and suppress tumor cells but also has been proved by many studies. Due to the rapid development of High Intensity Focused Ultrasound(HIFU), the ultrasound hyperthemia extensively boosts its applications in clinical field. For those reasons, Computed simulation factor should be needed before inspection to patients. To prove efficiency of ultrasonic hyperthermia, precise acoustic field measurement considering tissue characteristics and a heating experiment with tissue mimicking material phantom were conducted for effectiveness of simulation program. Finally, in this study, the computer simulation program verified the anticipated temperature effects induced by ultrasound hyperthermia. In the near future, it is hoped that this simulation program could be utilized to improve the efficiency of ultrasound hyperthermia.

채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구 (A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division)

  • 유병철;최흥호;노시철;민해기;권장우
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Wavelets 변환을 이용한 초음파 신호의 분석 (I) (An analysis of Ultrasound signals using wavelet transform (I))

  • 홍세원;윤세진;최홍호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.391-394
    • /
    • 1997
  • In this paper, we considered newly the use of wavelet transform in order to improve the troubles of the established methods for the analysis of ultrasound echo signals. We made the phantoms of 13.2g, 19.8g, 26.4g, 33.0g, 39.8g by ourselves, and extracted the only pulse-echo signals that reflected through the mediums using windowing technique. For determining the characterized value, the signals were wavelet transformed, absoluted, and integral calculated. As the result, we acquired characterized value of each signals, and acknowledged the differences among them except of some datas. But this will be improved by advanced work as sellecting a proper mother wavelet, a method of making phantoms, correcting the various errors, etc. We expect that wavelet transform is powerful for analysis of ultrasound signals.

  • PDF