• 제목/요약/키워드: Biomechanical model

검색결과 232건 처리시간 0.024초

하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구 (Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture)

  • 이원;강동희
    • 대한두개안면성형외과학회지
    • /
    • 제12권1호
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권6호
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

착좌시 하지 동작의 생체역학적 모델 (A biomechanical model of lower extremity for seated operators)

  • 황규성;이동춘;최재호
    • 대한인간공학회지
    • /
    • 제11권1호
    • /
    • pp.81-92
    • /
    • 1992
  • A two-dimensional static biochemical model of lower extremity in the seated posture was developed to assess muscular activities of lower extremity required for a variety of foot pedal operations. We found that the double linear optimization method that has been used for modelling articulated body segments does no predict the forces generated by biarticular muscles reasonably, so the revised double linear optimization scheme was used to consider the synergistic effects of biarticular muscles in our model, assuming that the muscle forces are distributed proportionally based on their physiological cross sectional area. The model incorporated three rigid body se- gments with six muscles to represnet lower extremity. For the model validation, three male subjects performed the experiments in which EMG activities of six lower extremity muscles were measured. Predicted muscle forces were compare with the corresponding EMG amplitudes and it showed no statistical difference. The model being developed can be used to design and assess pedal and foot-related tool design.

  • PDF

Finite Element Prediction of Temperature Distribution in a Solar Grain Dryer

  • Uluko, H.;Mailutha, J.T.;Kanali, C.L.;Shitanda, D.;Murase, H
    • Agricultural and Biosystems Engineering
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2006
  • A need exists to monitor and control the localized high temperatures often experienced in solar grain dryers, which result in grain cracking, reduced germination and loss of cooking quality. A verified finite element model would be a useful to monitor and control the drying process. This study examined the feasibility of the finite element method (FEM) to predict temperature distribution in solar grain dryers. To achieve this, an indirect solar grain dryer system was developed. It consisted of a solar collector, plenum and drying chambers, and an electric fan. The system was used to acquire the necessary input and output data for the finite element model. The input data comprised ambient and plenum chamber temperatures, prevailing wind velocities, thermal conductivities of air, grain and dryer wall, and node locations in the xy-plane. The outputs were temperature at the different nodes, and these were compared with measured values. The ${\pm}5%$ residual error interval employed in the analysis yielded an overall prediction performance level of 83.3% for temperature distribution in the dryer. Satisfactory prediction levels were also attained for the lateral (61.5-96.2%) and vertical (73.1-92.3%) directions of grain drying. These results demonstrate that it is feasible to use a two-dimensional (2-D) finite element model to predict temperature distribution in a grain solar dryer. Consequently, the method offers considerable advantage over experimental approaches as it reduces time requirements and the need for expensive measuring equipment, and it also yields relatively accurate results.

  • PDF

컴퓨터 그래픽 모델을 통한 보행 시 발의 생체역학적 해석 (Biomechanical analysis of human foot using the computer graphic-based model during walking)

  • 최현기;김시열;이범현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1088-1092
    • /
    • 2002
  • The purpose of this investigation was to study the kinematics of joints between foot segments based on computer graphic-based model during the stance phase of walking. In the model, ail joints were assumed to act as monocentric, single degree of freedom hinge joints. The motion of foot was captured by a video collection system using four cameras. The model fitted in an individual subject was simulated with this motion data. The kinematic data of tarsometatarsal joints and metatarso-phalangeal joint were quantitatively similar to the previous data. Therefore, our method using the computer graphic-based model is considered useful.

  • PDF

비선형 최적화기법을 이용한 하지근력 예측 인체역학 모형

  • 황규성;정의승;이동춘
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1994년도 춘계학술대회논문집
    • /
    • pp.124-135
    • /
    • 1994
  • A biomechanical model of lower extremity in seated postures was developed to assess muscular activities of lower extremity involved in a variety of foot pedal operations. It is found that nonlinear optimization method which has been used for modeling the articulated body segments does not predict the forces generated from biarticular muscles reasonably, so the revised nonlinear optimization scheme was employed to consider the synergistic effects of biarticular muscles in the model, assuming that the muscle forces are distributed proportionally based on their physiological cross sectional area and moment arm. The model incorporated four rigid body segments with the nine muscles to represent lower extreimity. For the model valida- tion, three male subjects performed the experiments in which EMG activities of the nine lower extremity muscles were measured. Predicted muscle forces were compared with the corresponding EMG amplitudes and it showed no statistical difference. The developed model can be used to design and to assess the pedals and foot-related equipments design.

  • PDF

Biomechanical study of the Spider Crab as inspiration for the development of a biomimetic robot

  • Rynkevic, Rita;Silva, Manuel F.;Marques, M. Arcelina
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권4호
    • /
    • pp.249-269
    • /
    • 2015
  • A problem faced by oil companies is the maintenance of the location register of pipelines that cross the surf zone, the regular survey of their location, and also their inspection. A survey of the state of art did not allow identifying operating systems capable of executing such tasks. Commercial technologies available on the market also do not address this problem and/or do not satisfy the presented requirements. A possible solution is to use robotic systems which have the ability to walk on the shore and in the surf zone, subject to existing currents and ripples, and being able to withstand these ambient conditions. In this sense, the authors propose the development of a spider crab biologically inspired robot to achieve those tasks. Based on these ideas, this work presents a biomechanical study of the spider crab, its modeling and simulation using the SimMechanics toolbox of Matlab/Simulink, which is the first phase of this more vast project. Results show a robot model that is moving in an "animal like" manner, the locomotion, the algorithm presented in this paper allows the crab to walk sideways, in the desired direction.

나사 파단 예방을 위해 새로 디자인한 경비 인대 결합 나사의 효용성: 생역학 연구 (The Efficacy of Newly Designed Screw for Prevention of the Screw Breakage in Syndesmosis Fixation: Biomechanical Study)

  • 이동오;송상헌
    • 대한족부족관절학회지
    • /
    • 제24권2호
    • /
    • pp.94-97
    • /
    • 2020
  • Purpose: Fatigue breakage of cortical screws sometimes occurs after syndesmosis fixation, regardless of the period of screw retention. This study compared the fatigue strength of a novel screw design to conventional cortical screws in the fixed state of syndesmosis. Materials and Methods: Twelve sawbone models were tested mechanically to determine the fatigue strength of three screw designs. The first group was composed of cortical screws, while the second and third groups were newly-designed screws. The second group was composed of screws with a 2.4-mm diameter thread-free portion of the mid-shank while the third group had a 2.0-mm diameter thread-free mid-shank. A 400 N load was applied repetitively to a fibula model and the number of cycles until screw failure was recorded. Four screws from each group were tested, giving a total of 12 fatigue tests. Results: The average cycles until screw failure for groups 1, 2, and 3 were 8,134, 63,186, and 2,581, respectively. The second group showed the highest fatigue strength (p=0.018). The other two screw designs showed similar fatigue strength (p=0.401). Conclusion: New screw designs with a thread-free portion in the mid-shank could reduce the occurrence of fatigue breakage after syndesmosis fixation.

한국형 파킨슨 환자의 역학적 기능수행지수 개발 (Developing an Biomechanical Functional Performance Index for Parkinson's Disease Patients)

  • Shin, Sunghoon;Han, Byungin;Chung, Chulmin;Lee, Yungon
    • 한국운동역학회지
    • /
    • 제30권1호
    • /
    • pp.83-91
    • /
    • 2020
  • Objective: The study aimed to develop a functional performance index that evaluates the functional performance of Parkinson's patients, i.e., to integrate biomechanical measurements of walking, balance, muscle strength and tremor, and to use multiple linear regression with stepwise methods to identify the most suitable predictors for the progression of disease. Method: A total of 60 subjects were tested for sub-variables of four factors: walking, balance, isometric strength and hand tremors. Potential independet variables were extracted through correlation analysis of the sub-variables and dependent variables, Hoehn & Yahr scale. And then, a stepwise multiple regression analysis using the potential independent variables was performed to identify predictor of Hoehn & Yahr scale. Results: First, the results of the study showed that physical composition and gait had a relatively more correlated with the progression of the disease, compared to balance and hand tremor. Second, Parkinson's functional performance is characterized by dynamic pattern of walking, such as foot clearance and turning angle (TA) of walking, and a high-explained regression model is completed. Conclusion: The study emphasized the importance of walking variables and body composition in minor pathological features compared to Parkinson's patient's balancing ability and hand tremor. Specifically, it revealed that dynamic walking patterns functionally characterize patients. The results are worth considering when assessing functional performance related to the progression of the disease at the site.

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.