• 제목/요약/키워드: Biomechanical characteristics

검색결과 145건 처리시간 0.024초

Effects of Caponization on Bone Characteristics and Histological Structure in Chickens

  • Chen, Kuo-Lung;Chang, Ming-Huang;Tsay, Shiow-Min;Hurng, Huaang-Youh;Chiou, Peter Wen-Shyg
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권2호
    • /
    • pp.245-251
    • /
    • 2006
  • The aim of this study was to investigate the effects of caponization on the bone characteristics, biomechanical property and histology in Taiwan country chickens fed to market age of 26 wks. Male Taiwan country chickens $D{\times}L_2$ were caponized or sham-operated at 8 wks of age, and selected healthy sham-operated and completely caponized chickens (prominent degenerated comb) were selected at 16 wks old and fed to 26 wks old for the trials. Fifteen intact male chickens (Intact), sham-operated chickens (Sham) and caponized chickens (Capon) were assigned for trial 1, and sixteen Intact and Capon were assigned for trial 2. Results in trial 1 showed that the abdominal fat and relative abdominal fat weights of Capon were significantly heavier than Intact and Sham (p<0.05), while the tibia weight and relative weight were the lightest (p<0.05). The tibia breaking strength, bending moment and stress of Capon were the poorest among groups (p<0.05). The trial 2 produced the similar observation that Capon were significantly lighter than Intact (p<0.05) in the tibia weight, relative tibia weight and their biomechanical properties. On histological determinations, Capon showed a thinner cartilage end and fewer chondrocytes (about 50%) and trabecular, and bigger marrow cavity; while decreased hemopoietic cells number with increased adipocytes than Intact observed by H&E stain and at low magnification. At high magnification, Capon showed a decrease in the chondrocyte size by 33 to 50%, with smaller nucleus located near the cell membrane, and exhibited monocellular form chondrocytes. Capon also showed a less strongly acidic sulfated mucosubstance with weaker dyeing property within cartilage zone, and smaller chondrocytes size by Alcian blue stain.

키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구 (A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness)

  • 박태현;정태곤;한동욱;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.

체감형 스키 시뮬레이터 개발을 위한 플루크보겐 동작의 운동역학적 비교 (Comparisons of Pflugbogen's Biomechanical Characteristics to Develop Interactive Ski Simulator)

  • 구도훈;이민현;권효순;현보람;은선덕
    • 한국운동역학회지
    • /
    • 제24권3호
    • /
    • pp.189-199
    • /
    • 2014
  • The purpose of this study was to compare pflugbogen's biomechanical characteristics between on the ski simulator and snowed ski slope to develop interactive ski simulator. Nine ski instructors(sex: male, age: $29.6{\pm}5.4yrs$, height: $176.0{\pm}5.6cm$, body mass: $76.0{\pm}14.0kg$) belong to Korean Ski Instructors Association participated in this research. 24 Infrared cameras for snowed ski slope experiment and 13 infrared camera for ski simulator experiment were installed near by path of pflugbogen. The participants did pflugbogen on the snowed ski slope and the ski simulator both. During the experiment, the participants weared motion capture suit with infrared reflective makers on it, and plantar pressure sensors in ski boots, so that ski motion and plantar pressure data were collected together. Displacement of COG(center of gravity) movements, trunk flexion/extension angle, adduction/abduction angle, and plantar pressure data were significantly different between on the simulator and ski slope. However, percentage of time of COG movement in the phases during medial/lateral and anterior/posterior movement were not significantly different. Findings indicate that the difference between two groups occurred because the ski simulator's drive mechanism is different from ski motion on the slope. In order to develop the ski simulator more interactively for pflugbogen, the ski simulator's drive mechanism need to be reflected 3D motion data of pflugbogen on the slope that were purposed in this research.

Influences of Geometric Configurations of Bypass Grafts on Hemodynamics in End-to-Side Anastomosis

  • Choi, Jae-Sung;Hong, Sung-Chul;Kwon, Hyuck-Moon;Suh, Sang-Ho;Lee, Jeong-Sang
    • Journal of Chest Surgery
    • /
    • 제44권2호
    • /
    • pp.89-98
    • /
    • 2011
  • Background: Although considerable efforts have been made to improve the graft patency in coronary artery bypass surgery, the role of biomechanical factors remains underrecognized. The aim of this study is to investigate the influences of geometric configurations of the bypass graft on hemodynamic characteristics in relation to anastomosis. Materials and Methods: The Numerical analysis focuses on understanding the flow patterns for different values of inlet and distal diameters and graft angles. The Blood flow field is treated as a two-dimensional incompressible laminar flow. A finite volume method is adopted for discretization of the governing equations. The Carreau model is employed as a constitutive equation for blood. In an attempt to obtain the optimal aorto-coronary bypass conditions, the blood flow characteristics are analyzed using in vitro models of the end-to-side anastomotic angles of $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$. To find the optimal graft configurations, the mass flow rates at the outlets of the four models are compared quantitatively. Results: This study finds that Model 3, whose bypass diameter is the same as the inlet diameter of the stenosed coronary artery, delivers the largest amount of blood and the least pressure drop along the arteries. Conclusion: Biomechanical factors are speculated to contribute to the graft patency in coronary artery bypass grafting.

만성 요통 환자의 골반지표와 발의 생체역학적 특징 연구 (Study on Pelvic Parameters and Biomechanical Characteristics of Foot in Patients with Chronic Low Back Pain)

  • 공재철;문수정;조동찬;고연석;송용선;이정한
    • 동의생리병리학회지
    • /
    • 제26권1호
    • /
    • pp.81-87
    • /
    • 2012
  • The structural and biomechanical characteristics of pelvic and foot are important factors of back pain, but it is still complicated to clearly explain the relationship among them. The purpose of this study was to find out the characteristic of pelvic parameters and biomechanics of foot in patients with low back pain. Thirty-three female subjects with chronic low back pain were enrolled and ODI and VAS score were measured for back pain index. All subjects were taken the X-ray examination for major pelvic parameters and foot scan analysis for foot pressure, gait angle, fore-foot/rear-foot peak pressure ratio and asymmetric index. Statistical analysis were performed to examine the inter-relation between the measurement. As a result, it was shown the positive interrelation between back pain and F/R ratio, but others were not shown the relationship related to low back pain. And there were correlations between the lumbo-pelvic structure and biomechanics of foot in some aspects, but the causal relationship between them are still indefinable. In order to get more information about structures and biomechanics related to low back pain, subsequent researches are needed.

사용자 환경 모니터링을 위한 소형 자가발전 무선 데이터 송수신 시스템 개발 (Fabrication of Portable Self-Powered Wireless Data Transmitting and Receiving System for User Environment Monitoring)

  • 장순민;조수민;정윤수;김재형;김현수;장다연;라윤상;이동한;라문우;최동휘
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.249-254
    • /
    • 2022
  • 최근 반도체와 같은 정보통신 기술의 발전과 함께 사물인터넷(IoT) 기술 발전이 급격히 이루어지면서 센서와 무선 통신 기능을 내장하여 주변 사물 및 환경 조건을 감지 및 분석하여 대응하는 원격 환경 모니터링 기술이 주목받고 있다. 하지만, 기 개발된 원격 환경 모니터링 시스템은 모두 별도의 전원 공급 장치를 필요로 하기 때문에 시·공간적 기기 사용의 제한을 야기하여, 사용자의 불편함을 유발할 수 있다. 따라서, 본 연구에서는 생체 역학적 에너지의 역학적 특성이 고려된 기구학적 설계 기반 전자기 발전 소자(Electromagnetic generator, EMG)를 개발함으로써 이의 에너지 자립형 원격 환경 모니터링 구동을 위한 전원 공급 장치로써 활용한다. 낮은 진동 주기 및 큰 진폭 변화의 역학적 특성을 지닌 생체 역학적 에너지를 효과적으로 이용하기 위해 자석의 기구학적 배치를 통한 깨지기 쉬운 힘의 평형을 유도하는 Levitation-EMG (L-EMG)를 설계했다. 이를 통해, L-EMG는 외부 진동에 민감하게 반응하여 자석과 코일 간의 효과적인 상대 움직임을 야기하여 고품질 전기 에너지 공급을 가능하게 했다. 뿐만 아니라, 실제 환경 감지 센서와 무선 통신 모듈의 필요 전력을 최소화하기 위한 마이크로 컨트롤러(Micro control unit, MCU)를 구성하였으며, 내장기능 중 저전력모드(Sleep mode)를 접목하여 소비전력의 최소화 및 이의 구동시간 증가를 달성했다. 최종적으로 사용자의 편의성을 극대화하기 위해 휴대폰 어플리케이션을 구축하여 손쉽게 주변 환경 모니터링을 가능하게 했다. 따라서, 이번 연구는 생체역학적 에너지를 이용한 에너지 자립형 원격 환경 모니터링 구축 가능성을 검증할 뿐만 아니라, 더 나아가 별도의 외부 전원 없이 주변 환경 모니터링이 가능한 설계 방안을 제시할 수 있다.

관절의 수동탄성특성을 이용한 족부의 생체역학적 해석 (Biomechanical Analysis of the Human Foot by Using Passive Elastic Characteristics of Joints)

  • 김시열;최현기
    • 한국정밀공학회지
    • /
    • 제21권1호
    • /
    • pp.197-204
    • /
    • 2004
  • In this study we presented kinematic and kinetic data of foot joints using approximated equations and partial plantar pressure during gait. The maximum angular displacements of each tarsometatarsal joint were found to range from 4$^{\circ}$to 7$^{\circ}$ and the maximum moments were from 200Nㆍcm to 1500Nㆍcm. It was relatively wide distribution. Foot kinematic data calculated from the approximated equations, which were represented by the correlation between moment and angular displacement, and the data from motion analysis were similar. We found that the movements of foot joint were mainly decided by the passive characteristics of the joint when ground reaction force acts. The method of kinematic and kinetic analysis using approximated equations which is presented in this study is considered useful to describe the movements of foot joints in gait simulations.

허리지지를 위한 사무용 의자 개발 (Development of Office Chair for Lumbar Support)

  • 박수찬;이영신;김동진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.376-380
    • /
    • 2000
  • All chairs are uncomfortable in the long run, but some chairs become uncomfortable more rapidly than others, and in any particular chair, some people will be more uncomfortable than others. Comfort will depend upon the interaction of chair characteristics, user characteristics, and task characteristics. In this study, we intend to design the comfortable office chair by investigating the anthropometric and biomechanical aspects for Korean. Therefore, we determine the design dimensions using the analysis of anthropometric data. With these dimensions, we design the chair mechanism of which backrest reclines with increasing chair pan declination. This mechanism allows the back to get adequate support at the correct level for any backrest declination. Also, the lumbar support in the backrest descends with increasing backrest reclining. By using this chair, a considerably better sitting posture can be obtained, and uncomfortable feeling and back pain may be prevented.

  • PDF

한국인과 서구인 청년층의 보행특성 비교 (A Comparison of Gait Characteristics between Korean and Western Young People)

  • 임완수;최화순;정민근;류태범;최훈우
    • 대한인간공학회지
    • /
    • 제25권2호
    • /
    • pp.33-42
    • /
    • 2006
  • It is important to analyze the characteristics of normal gait in clinical and biomechanical aspects. Although gait characteristics can be varied by anthropometric, racial and cultural factors, normal gait studies have been performed mostly for Western people. The present study conducted a gait analysis for Korean young adults and compared the gait characteristics with those of Western people for the establishment of Korean normal gait data. A total of thirty-two adults in twenties(20 males and 12 females) were participated in the gait experiment and their spatio-temporal and kinematic/kinetic gait characteristics were analyzed. The comparison of the gait characteristics between Korean and Western people, revealed that the stride length and walking speed of Korean were significantly smaller than those of Western people by 0.1~0.3m and 0.15~0.40m/s respectively. And the knee abduction moment of Korean was larger than that of Western people, while the other moments(such as hip flexion/extension moments, abduction/adduction moments, and knee flexion/extension moments) were smaller than those of Western people. The ranges of joint angles between the gait studies were largely different with each other, but most of motion patterns and excursions were similar.