• Title/Summary/Keyword: Biomechanical analysis

Search Result 476, Processing Time 0.032 seconds

A Biomechanical Analysis of Stress Transfer Behaviors Within the Necrotic Area of Femoral Head secondary to Changes in Core Placement Direction on Various Distributions of Necrotic Areas in the Osteonecrosis of the Femoral Head (대퇴골두 무혈성 괴사증에 있어서 괴사 영역의 위치와 천공방향의 변화에 따른 대퇴골두 괴사영역에서의 응력 변화 분석에 대한 생체역학적인 고찰)

  • Lim, D.H.;Lee, S.J.;Kim, J.S.;Shin, J.W.;Kim, Y.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.157-158
    • /
    • 1998
  • The purpose of this study was to test the hypothesis that even very small change of the cue direction in the treatment of the early osteonecrosis could affect the outcomes of operation. For this, the changes in stress transfer within the necrotic area of the femoral head were investigated under various directions and placements of the core utilizing finite element method. The loading of 3188N, which represents after-heel-strike, was imposed in cubic cosine pattern. All nodes on the most distal surface of the model were constrained in all directions. All materials included were assumed to have linear-elastic behavior. The result says that the critical stress, which causes collapse of the femoral head, was reduced when the core was oriented toward the posterior side of the femoral head regardless of location of the necrotic area. The same result was obtained either fibular bone grafting or cementation was adopted. As a consequence, the biomechanical study suggests that the core should be directed toward the loading point where the resultant force is applied to get more desirable treatment of the osteonecrosis of the femoral head in the early stage.

  • PDF

A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness (키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구)

  • Park, T.H.;Jung, T.G.;Han, D.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.

Influences of Geometric Configurations of Bypass Grafts on Hemodynamics in End-to-Side Anastomosis

  • Choi, Jae-Sung;Hong, Sung-Chul;Kwon, Hyuck-Moon;Suh, Sang-Ho;Lee, Jeong-Sang
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.89-98
    • /
    • 2011
  • Background: Although considerable efforts have been made to improve the graft patency in coronary artery bypass surgery, the role of biomechanical factors remains underrecognized. The aim of this study is to investigate the influences of geometric configurations of the bypass graft on hemodynamic characteristics in relation to anastomosis. Materials and Methods: The Numerical analysis focuses on understanding the flow patterns for different values of inlet and distal diameters and graft angles. The Blood flow field is treated as a two-dimensional incompressible laminar flow. A finite volume method is adopted for discretization of the governing equations. The Carreau model is employed as a constitutive equation for blood. In an attempt to obtain the optimal aorto-coronary bypass conditions, the blood flow characteristics are analyzed using in vitro models of the end-to-side anastomotic angles of $45^{\circ}$, $60^{\circ}$ and $90^{\circ}$. To find the optimal graft configurations, the mass flow rates at the outlets of the four models are compared quantitatively. Results: This study finds that Model 3, whose bypass diameter is the same as the inlet diameter of the stenosed coronary artery, delivers the largest amount of blood and the least pressure drop along the arteries. Conclusion: Biomechanical factors are speculated to contribute to the graft patency in coronary artery bypass grafting.

Analysis of the Differences of the Shock Attenuation Strategy between Double-leg and Single-leg Landing on Sagittal Plane using Statistical Parametric Mapping (Statistical Parametric Mapping을 이용한 시상면에서의 양발 착지와 외발 착지의 전략 차이)

  • Ha, Sunghe;Park, Sang-Kyoon;Lee, Sae Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.4
    • /
    • pp.255-261
    • /
    • 2019
  • Objective: The purpose of this study was to investigate differences of shock attenuation strategies between double-leg and single-leg landing on sagittal plane using statistical parametric mapping. Method: Nine healthy female professional soccer players (age: 24.0±2.5 yrs, height: 164.9±3.3 cm, weight: 55.7±6.6 kg, career: 11.2±1.4 yrs) were participated in this study. The subjects performed 10 times of double-leg and single-leg landing from the box of 30 cm height onto force plates respectively. The ground reaction force, angle, moment, angular velocity, and power of the ankle, knee, and hip joint on sagittal plane was calculated from initial contact to maximum knee flexion during landing phase. Statistical parametric mapping was used to compare the biomechanical variables of double-leg and single-leg landing of the dominant leg throughout the landing phase. Each mean difference of variables was analyzed using a paired t-test and alpha level was set to 0.05. Results: For the biomechanical variables, significantly increased vertical ground reaction force, plantarflexion moment of the ankle joint, negative ankle joint power and extension moment of the hip joint were found in single-leg landing compared to double-leg landing (p<.05). In addition, the flexion angle and angular velocity of the knee and hip joint in double-leg landing were observed significantly greater than single-leg landing, respectively (p<.05). Conclusion: These findings suggested that negative joint power and plantarflexion moment of the ankle joint can contribute to shock absorption during single-leg landing and may be the factors for preventing the musculoskeletal injuries of the lower extremity by an external force.

Sports Biomechanical Analysis before and after Applying Weight Belt during Squat Exercise (스쿼트 동작 시 웨이트 벨트 착용 전·후에 따른 운동역학적 분석)

  • LEE, Jeong-Ki;HEO, Bo-Seob;KIM, Yong-Jae;LEE, Hyo-Taek
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.893-902
    • /
    • 2016
  • The purpose of this study is to investigate the effect of wearing a weightlifting belt, which is an auxiliary equipment used during squat, by measuring and analyzing biomechanical difference in lower limb and proposing safer and to suggest a more effective exercise method for general population. Selected 8 male participants in their 20s who have not performed regular resistance exercise for at least a year, but have experience of performing squat. The comprehensive method of study is as follows: subjects were notified of the purpose of the study and were told to practice warm-up and the squat motion for the experiment for 20 minutes. When the participant believed they were ready to begin, the experiment was started. At controlled points, foot pressure distribution sensor has been installed. Then left and right feet have been placed on the pressure distribution sensor, from which data for successful squat position that does not satisfy the criteria for failure have been collected and computed with Kwon3D XP program and TPScan program. For data processing of this study, SPSS 21.0 was used to calculated mean (M) and standard deviation (SD) of the analyzed values, and paired t-test has been conducted to investigate the difference before and after wearing the weightlifting belt, with p-value of ${\alpha}<.05$. As for time consumed depending on usage of weightlifting belt in squat, statistically significant difference has been found in P2, which is recovery movement. Lower limb angle depending on usage of weightlifting belt in squat has shown statistically significant difference in E1 foot joint(p<. 001). There has been statistically significant difference in E2 knee joint. Foot pressure percentage depending on usage of weightlifting belt in squat were found to be statistically significant (p<. 01) in both regions of anterior and posterior foot.

The analysis of biomechanical gender difference of K-Pop dance lower body movement (K-Pop 댄스 하지동작의 생체역학적 남녀 차이 분석)

  • Jang, Young-Kwan;Hong, Su-Yeon;Ki, Jae-sug;Jang, In-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.95-101
    • /
    • 2017
  • The purpose of this study was to investigate the biomechanical of K-Pop dance movement. The study was conducted on 15 male and 15 female subjects in 20-30 age groups. And they choose 150 K-Pop dance choreographies in the top 10 ranking of the main charts. We analyzed the RoM, joint moment and impulse force of the highlight movements. First, During the K-Pop dance motion, the usage of knee joints are more than the hip joints and the ankle joints, and female dancers has a larger range of motion than the male dancers. Second, male dancer uses more than female dancers when they compared the load of male dancers and female dancers. In particular, flexion and extension of the hip joints are mostly used in this study. Third, the impulse force of male dancers was greater than of female dancers, but it was statistically insignificant, this is equal to the impulse on walking. In conclusion, Female dancers use more range of motion than male dancers, but male dancer choreography requires greater torque, which can strain joints. Most choreographic exercises involve movements such as hip joint, knee joint, flexion of ankle joint, extension, rotation, and jumping.

Biomechanical Analysis of Key Motion on BoA's No. 1 in K-Pop Dance (보아의 K-Pop 넘버원 댄스 핵심동작의 생체역학적 분석)

  • Hah, Chong-Ku;Jang, Young-Kwan;Ki, Jae-Sug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.970-977
    • /
    • 2015
  • The purpose of this study was to investigate biomechanical factors on key motions in K-Pop dance(BoA's No.1). A professional choreographer who was BoA's K-Pop No. 1 dance participated in this study. ROMs(range of motion) of shoulder and elbow joints in AP direction were greater than other joints. Those of trunk and pelvis in ML direction were the greatest of other directions. The velocity of CoG in SI direction was greater than other directions, and also max angular velocities of shoulder, elbow, knee, and hip joints in AP direction were the greatest of all directions. But ROM and angular velocity of ankle joint were very small. Max rotational powers of shoulder and knee joints were larger than other joints.

Effect of Whole Body Vibration on Osteoporotic Trabecular Bone of Rats - Compared with the Effect of Actonel (전신진동이 골다공증이 유발된 쥐 해면골에 미치는 영향 - 골다공증 치료제 효과와 비교)

  • Ko, Chang-Yong;Lee, Tae-Woo;Woo, Dae-Gon;Kim, Hyo-Seon;Kim, Han-Sung;Lee, Beob-Yi;Lim, Do-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.148-154
    • /
    • 2008
  • Pharmacotherapy was mainly used to treat osteoporosis. However, some researches showed that pharmacotherapy could induce unexpected adverse effects. Some studies showed that whole body vibration affected beneficially osteoporosis. This paper studied the effect of whole body vibration fur osteoporosis compared with the effect of pharmacotherapy. 10 female rats were used and allocated into 4 group, CON, SHAM, DRUG, and WBV. Rats except SHAM group were ovariectomised to induce osteoporosis. Rats in WBV group were stimulated in whole body vibration at magnitude of $1mm_{peak-peak}$ and frequency 45Hz, for 8 weeks (30 min/day, 5 days/week). Rat in DRGU group was orally administered the Actonel (0.58mg/Kg), for 8 weeks (5days/week). The $4^{th}$ lumbar in rats were scanned at a resolution of $35{\mu}m$ at baseline, before stimulation, and 8 weeks after stimulation by In-vivo micro computed tomography. For detecting and tracking changes of biomechanical characteristics (morphological and mechanical characteristics) in lumbar trabecuar bone of rats, structural parameters were measured and calculated from acquiring images and finite element analysis was performed. In the results, loss of quantity and change of structure of trabecular bone in WBV group were smaller than those in both CON and SHAM groups. In addition, mechanical strength in WBV group was stronger than that in both CON and SHAM groups. In contrast, biomechanical characteristics in WBV group were similar with those in DRUG group. These results showed that reasonable whole body vibration was likely to treat osteoporosis and be substituted partly for drug treatment.

Load response of the natural tooth and dental implant: A comparative biomechanics study

  • Robinson, Dale;Aguilar, Luis;Gatti, Andrea;Abduo, Jaafar;Lee, Peter Vee Sin;Ackland, David
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.169-178
    • /
    • 2019
  • PURPOSE. While dental implants have displayed high success rates, poor mechanical fixation is a common complication, and their biomechanical response to occlusal loading remains poorly understood. This study aimed to develop and validate a computational model of a natural first premolar and a dental implant with matching crown morphology, and quantify their mechanical response to loading at the occlusal surface. MATERIALS AND METHODS. A finite-element model of the stomatognathic system comprising the mandible, first premolar and periodontal ligament (PDL) was developed based on a natural human tooth, and a model of a dental implant of identical occlusal geometry was also created. Occlusal loading was simulated using point forces applied at seven landmarks on each crown. Model predictions were validated using strain gauge measurements acquired during loading of matched physical models of the tooth and implant assemblies. RESULTS. For the natural tooth, the maximum vonMises stress (6.4 MPa) and maximal principal strains at the mandible ($1.8m{\varepsilon}$, $-1.7m{\varepsilon}$) were lower than those observed at the prosthetic tooth (12.5 MPa, $3.2m{\varepsilon}$, and $-4.4m{\varepsilon}$, respectively). As occlusal load was applied more bucally relative to the tooth central axis, stress and strain magnitudes increased. CONCLUSION. Occlusal loading of the natural tooth results in lower stress-strain magnitudes in the underlying alveolar bone than those associated with a dental implant of matched occlusal anatomy. The PDL may function to mitigate axial and bending stress intensities resulting from off-centered occlusal loads. The findings may be useful in dental implant design, restoration material selection, and surgical planning.

Barbed sutures versus conventional tenorrhaphy in flexor tendon repair: An ex vivo biomechanical analysis

  • Colak, Ozlem;Kankaya, Yuksel;Sungur, Nezih;Ozer, Kadri;Gursoy, Koray;Serbetci, Kemal;Kocer, Ugur
    • Archives of Plastic Surgery
    • /
    • v.46 no.3
    • /
    • pp.228-234
    • /
    • 2019
  • Background The management of flexor tendon injuries has evolved in recent years through industrial improvements in suture materials, refinements of repair methods, and early rehabilitation protocols. However, there is no consensus on the ideal suture material and technique. This study was conducted to compare the tensile strength, repair time, and characteristics of 4-strand cruciate, modified Kessler, and 4-strand horizontal intrafiber barbed sutures for flexor tenorrhaphy with a 12-mm suture purchase length in an animal model. Methods The right third deep flexors of 60 adult Leghorn chicken feet were isolated and repaired with a 12-mm suture purchase length. The tendons were randomly assigned to three groups of equal number (n=20 each). Groups 1 and 2 received 4-strand cruciate and modified Kessler repair with conventional suture materials, respectively. A 4-strand horizontal intrafiber barbed suture technique was used in group 3. The repaired tendons were biomechanically tested for tensile strength, 2-mm gap resistance, and mode of failure. Repair times were also recorded. Results The maximum tensile strength until failure was $44.6{\pm}4.3N$ in group 1, $35.7{\pm}5.2N$ in group 2, and $56.7{\pm}17.3N$ in group 3. The barbed sutures were superior to the other sutures in terms of the load needed for 2-mm gap formation (P<0.05). Furthermore, the barbed sutures showed the shortest repair time (P<0.05). Conclusions This study found that 4-strand horizontal intrafiber barbed suture repair with a 12-mm purchase length in a chicken flexor tendon injury model showed promising biomechanical properties and took less time to perform than other options.