• Title/Summary/Keyword: Biomechanical Modeling

Search Result 43, Processing Time 0.041 seconds

Length-tension and velocity-force relationships of the torso extensors:Dynamic biomechanical modeling considerations

  • Raschke, U.;Chaffin, D.B.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.137-140
    • /
    • 1996
  • This study investigated the length-tension and velocity-force relations of the torso erectors. A myoelectric based approach was used wherein a dynamic biomechanical model incorporating active and passive tissue charactreistics provided music kinematic estimates during controlled sagittal plan extension motions. A double linear optimization formulation from the literatured provided muscle tension estimates. The data supported a linear length-tension relation toward full flexion for both the erector spinae and latissimus muscles. Velocity trends agreed with that predicted by Hill's exponential relation. The results have implications for muscle tension estimation in biomechanical torso modeling, and suggest a possible low back pain injury mechanism.

  • PDF

A study on the micro-structural and biomechanical properties of trabecular bone in intertrochanteric region (대퇴골 전자간부 해면골의 미세구조적 특성과 생역학적 특성에 관한 연구)

  • Baek M.H.;Won Y.Y;Cui W.Q.;Kim K.K;Kim H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.923-926
    • /
    • 2005
  • To investigate the relationship between BMD, micro-structural and mechanical properties in intertrochanteric trabecular bone, the PIXI-mus2 system, micro-CT and FE model were used. The purpose of this study were (1) to apply high-resolution imaging techniques (micro-CT imaging) in combination with new computer modeling techniques (FEA) to quantify 3D microstructural and biomechanical properties of trabecular bone in the intertrochanteric region, and (2) determine if the prediction of bone elastic constant can be improved with structural index.

  • PDF

Biomechanical Characterization with Inverse FE Model Parameter Estimation: Macro and Micro Applications (유한요소 모델 변수의 역 추정법을 이용한 생체의 물성 규명)

  • Ahn, Bum-Mo;Kim, Yeong-Jin;Shin, Jennifer H.;Kim, Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.11
    • /
    • pp.1202-1208
    • /
    • 2009
  • An inverse finite element (FE) model parameter estimation algorithm can be used to characterize mechanical properties of biological tissues. Using this algorithm, we can consider the influence of material nonlinearity, contact mechanics, complex boundary conditions, and geometrical constraints in the modeling. In this study, biomechanical experiments on macro and micro samples are conducted and characterized with the developed algorithm. Macro scale experiments were performed to measure the force response of porcine livers against mechanical loadings using one-dimensional indentation device. The force response of the human liver cancer cells was also measured by the atomic force microscope (AFM). The mechanical behavior of porcine livers (macro) and human liver cancer cells (micro) were characterized with the algorithm via hyperelastic and linear viscoelastic models. The developed models are suitable for computing accurate reaction force on tools and deformation of biomechanical tissues.

Biomechanical evaluations of the long-term stability of dental implant using finite element modeling method: a systematic review

  • Hosseini-Faradonbeh, Seyed Aref;Katoozian, Hamid Reza
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.182-202
    • /
    • 2022
  • PURPOSE. The aim of this study is to summarize various biomechanical aspects in evaluating the long-term stability of dental implants based on finite element method (FEM). MATERIALS AND METHODS. A comprehensive search was performed among published studies over the last 20 years in three databases; PubMed, Scopus, and Google Scholar. The studies are arranged in a comparative table based on their publication date. Also, the variety of modeling is shown in the form of graphs and tables. Various aspects of the studies conducted were discussed here. RESULTS. By reviewing the titles and abstracts, 9 main categories were extracted and discussed as follows: implant materials, the focus of the study on bone or implant as well as the interface area, type of loading, element shape, parts of the model, boundary conditions, failure criteria, statistical analysis, and experimental tests performed to validate the results. It was found that most of the studied articles contain a model of the jaw bone (cortical and cancellous bone). The material properties were generally derived from the literature. Approximately 43% of the studies attempted to examine the implant and surrounding bone simultaneously. Almost 42% of the studies performed experimental tests to validate the modeling. CONCLUSION. Based on the results of the studies reviewed, there is no "optimal" design guideline, but more reliable design of implant is possible. This review study can be a starting point for more detailed investigations of dental implant longevity.

Biomechanical study of the Spider Crab as inspiration for the development of a biomimetic robot

  • Rynkevic, Rita;Silva, Manuel F.;Marques, M. Arcelina
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.4
    • /
    • pp.249-269
    • /
    • 2015
  • A problem faced by oil companies is the maintenance of the location register of pipelines that cross the surf zone, the regular survey of their location, and also their inspection. A survey of the state of art did not allow identifying operating systems capable of executing such tasks. Commercial technologies available on the market also do not address this problem and/or do not satisfy the presented requirements. A possible solution is to use robotic systems which have the ability to walk on the shore and in the surf zone, subject to existing currents and ripples, and being able to withstand these ambient conditions. In this sense, the authors propose the development of a spider crab biologically inspired robot to achieve those tasks. Based on these ideas, this work presents a biomechanical study of the spider crab, its modeling and simulation using the SimMechanics toolbox of Matlab/Simulink, which is the first phase of this more vast project. Results show a robot model that is moving in an "animal like" manner, the locomotion, the algorithm presented in this paper allows the crab to walk sideways, in the desired direction.

Development of a nonlinear biomechanical soft tissue model for a virtual surgery trainer (가상수술기를 위한 비선형 생체 모델의 개발)

  • Kim J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.911-914
    • /
    • 2005
  • Soft tissue characterization and modeling based on living tissues has been investigated in order to provide a more realistic behavior in a virtual reality based surgical simulation. In this paper, we characterize the nonlinear viscoelastic properties of intra-abdominal organs using the data from in vivo animal experiments and inverse FE parameter estimation algorithm. In the assumptions of quasi-linear-viscoelastic theory, we estimated the nonlinear material parameters to provide a physically based simulation of tissue deformations. To calibrate the parameters to the experimental results, we developed a three dimensional FE model to simulate the forces at the indenter and an optimization program that updates new parameters and runs the simulation iteratively. The comparison between simulation and experimental behavior of pig intra abdominal soft tissue are presented to provide a validness of the tissue model using our approach.

  • PDF

Finite element modeling of the mandible using voxel mesh method (Voxel mesh 기법을 이용한 하악골의 유한요소모델링)

  • 이은택;오택열;변창환;이병권;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.600-604
    • /
    • 1997
  • Knowledge of the complex biomechanical behavior of the human mandible is of great importance in various clinical situations. Various approaches can be used to evaluate the physical behavior of bone. In this study, we developed the voxel mesh program(Bionix) and generated FE models of mandible using Bionix and using handmade work and compared them with free vibration results derived from finite element analysis(FEA). The data of FE models based on DICOM File exported from Computed tomography(CT). Comparing the two models, we found a good correlation about mode type and natural frequency. The voxel based finite element mesh is a valid and accurate method to predict parameters of the complex biomechanical behavior of human mandibles.

  • PDF

Biomechanical Analysis with the Force of Deltoid Muscle for Pianist

  • Shin, Dong-Ok;La, Seung-Houn
    • International Journal of Safety
    • /
    • v.4 no.1
    • /
    • pp.27-31
    • /
    • 2005
  • This study presents the relationship between the height of the chair and the force of deltoid muscle for pianist. The subject simulated playing the piano on the three different heights of the chairs. Digital camera was used to determine the angle of the joint of shoulder and elbow for 2-dimensional static link segment modeling in the sagittal plane. The deltoid, biceps and triceps muscles were considered to determine the muscle load. The results, compared to the force of deltoid muscle, are that the downward position of the higher chair produces significantly large force than the other two lower chairs. It can be caused by hunched shoulder with decreasing deltoid angle. In case of the upward position caused by the lower chair, even though the smallest force of deltoid presented, it was increased the force of elbow.

Modeling and Numerical Investigation of the Biomechanical Interaction for Human-Rifle System

  • Chae, Je-Wook;Lee, Young-Shin
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2069-2079
    • /
    • 2004
  • This paper represents the description of a complex mathematical model of biomechanical interaction for human-rifle system during shooting. The model is developed by finite element method using bar elements. And three typical shooting positions, i.e. standing, kneeling and prone are used. Characteristics of interior/exterior ballistics and behaviors of human-rifle system are evaluated by this model, which takes into account the influence of environment, bullet, powder, barrel geometry parameters and anthropological parameters. The results of this study can be applied to anthropology, biomechanics, medical science, gait analysis, interior ballistics and exterior ballistics.