• Title/Summary/Keyword: Biomechanical Method

Search Result 229, Processing Time 0.028 seconds

Estimation of anthropometric body dimensions and joint strengths of a worker performing manual materials handling tasks using a multivariate normal simulation model (다변량 정규분포 모의모형을 이용한 물자운반작업을 수행하는 작업자의 인체 치수 및 관절염력의 예측에 관한 연구)

  • 변승남
    • Journal of the Ergonomics Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.63-83
    • /
    • 1993
  • The primary objective of the research is to develop a mathematical method to incorporate the variability of anthropometric body dimensions and joint strengths of individuals in a biomechanical analysis. A multivariate normal simulation model estimated anthropometric body dimensions and joint strengths of the random link-person, based on the assumptions that the vari- ables of body dimensions and joint strengths are correlated and follow normal distributions. Statistical comparative analysis demonstrated that the random link-person represented a more realistic human-like form in an anthropometric sense than the proportional link-person whose body dimensions were estimated proportionally. Estimated joint strengths for the random link-person, however, did not match the measured joint strengths as closely as the estimated body dimensions. The random link-person will allow biomechanical analysis of manual materials handling tasks to be individualized with respect to the anthropometry and a static strength.

  • PDF

Impedance modulation of anthropomorphic robots with kinematic and force redundancies (여유자유도/여유구동 인체형 로봇의 임피던스 생성방식)

  • 이병주;김희국;이재훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1289-1292
    • /
    • 1997
  • Typical biomechanical system such as human body and mammals possess abundant muscles which are more than required for motion generation of such systems. We have shown that the excess number of muscles play important roles in spring-like impedance modulation. redundant kinematic structure, which is another feature of biomechanical systems, allows modulations of inertia and damping properties of such systems. In this work, we propose a frequency modulation algorithm which combines the spring-like impedance with inertia impedance. also, a load distribution method for frequency modulation is also introduced. The frequency modulation represents a simulataneous control of force and kinematic redundancies, which has not been addressed in the literature.

  • PDF

Fabrication and Biomechanical Characteristics of Composite Ceramic Bone Scaffolds for Bone Tissue Engineering (골 생체조직공학을 위한 복합 세라믹 골 지지체의 제조와 생체역학적 특성)

  • Kim E. S.;Chung J. H.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.5 s.106
    • /
    • pp.457-466
    • /
    • 2004
  • Novel porous composite ceramic bone scaffolds composed of biodegradable PHBV(polyhydroxybutyrate-co-hydroxyvalerate) and TA(toothapatite) have been fabricated for bone tissue engineering by a modified solvent casting and particulate leach-ing method with salt-contained heat compression technique. The results of this study suggest that the PHBV-TA composite scaffold, especially the scaffold containing 30 weight$\%$ of TA may be a good candidate far bone tissue engineering of non-load bearing area in oral and maxillofacial region.

A Study on the Stress and Strain Analysis of Human Muscle Skeletal Model in Kendo Three Typical Attack Motions (세 가지 주요 검도 공격 동작에서의 근-골격계 응력과 번형률 해석에 관한 연구)

  • Lee, Jung-Hyun;Lee, Young-Shin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.9
    • /
    • pp.126-134
    • /
    • 2008
  • Kendo is one of the popular sports in modem life. Head, wrist and thrust attack are the fast skill to get a score on a match. Human muscle skeletal model was developed for biomechanical study. The human model was consists with 19 bone-skeleton and 122 muscles. Muscle number of upper limb, trunk and lower limb part are 28, 60, 34 respectively. Bone was modeled with 3D beam element and muscle was modeled with spar element. For upper limb muscle modelling, rectus abdominis, trapezius, deltoideus, biceps brachii, triceps brachii muscle and other main muscles were considered. Lower limb muscle was modeled with gastrocenemius, gluteus maximus, gluteus medius and related muscles. The biomechanical stress and strain analysis of human muscle was conducted by proposed human bone-muscle finite element analysis model under head, wrist and thrust attack for kendo training.

Development on Human Muscle Skeletal Model and Stress Analysis of Kumdo Head Hitting Motion (검도 머리치기 동작의 인체 근골격 모델개발 및 응력해석)

  • Lee, Jung-Hyun;Lee, Se-Hoon;Lee, Young-Shin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.11
    • /
    • pp.116-125
    • /
    • 2007
  • Human muscle skeletal model was developed for biomechanical study. The human model was consists with 19 bone-skeleton and 122 muscles. Muscle number of upper limb, trunk and lower limb part are 28, 60, 34 respectively. Bone was modeled with 3D beam element and muscle was modeled with spar element. For upper limb muscle modelling, rectus abdominis, trapezius, deltoideus, biceps brachii, triceps brachii muscle and other main muscles were considered. Lower limb muscle was modeled with gastrocenemius, gluteus maximus, gluteus medius and related muscles. The biomechanical stress and strain analysis of human was conducted by proposed finite element analysis model under Kumdo head hitting motion. In this study structural analysis has been performed in order to investigate the human body impact by Kumdo head hitting motion. As the results, the analytical displacement, stress and strain of human body are presented.

Biomechanical Analysis of Human Balance Control

  • Shin, Youngkyun;Park, Gu-Bum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.63-71
    • /
    • 2014
  • A single-inverted-pendulum model is presented to simulate and predict the passive response of human balance control. This simplified biomechanical model was comprised of a torsional spring and damper, and a lump mass. An estimation of frequency response function was conducted to parameterize the complexity. The frequency domain identification method is used to identify the parameters of the model. The equivalent viscoelastic parameters of standing body were obtained and there was good conformity between the simulation and experimental result.

Modeling and Numerical Investigation of the Biomechanical Interaction for Human-Rifle System

  • Chae, Je-Wook;Lee, Young-Shin
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2069-2079
    • /
    • 2004
  • This paper represents the description of a complex mathematical model of biomechanical interaction for human-rifle system during shooting. The model is developed by finite element method using bar elements. And three typical shooting positions, i.e. standing, kneeling and prone are used. Characteristics of interior/exterior ballistics and behaviors of human-rifle system are evaluated by this model, which takes into account the influence of environment, bullet, powder, barrel geometry parameters and anthropological parameters. The results of this study can be applied to anthropology, biomechanics, medical science, gait analysis, interior ballistics and exterior ballistics.

A study on the finite element modeling of femur based marching cube algorithm (Marching cube 알고리즘을 이용한 대퇴골의 유한요소 모델링에 관한 연구)

  • 곽명근;오택열;변창환;이은택;유용석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1074-1077
    • /
    • 2002
  • Biomechanical behavior of the human femur is very important in various clinical situations. In this study, the data of FE models based on DICOM file exported from Computed tomography(CT). We generated FE models(voxel model, tetra model) of human femur using CT slide image. We compared them with Yon Mises stress results derived from finite element analysis(FEA). Comparing the two models, we found a correlation of them. As a result, the tetra model based proposed marching cube algorithm is a valid and accurate method to predict parameters of the complex biomechanical behavior of human femur.

  • PDF

Development of Intelligent Robot for Anastomosis of Intestine (대장 소장 원형문합수술을 위한 지능형 로봇개발)

  • Kwun Y.M.;Hong J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.139-143
    • /
    • 2005
  • As increasing gastrointestinal pathologies, general and thoracic surgeries using circular staplers have been dramatically increased. Because of convenience for surgical procedure, recently, various circular staplers for anastomosis have been used widely. Since the circular staplers conventional have used the displacement control method, however, the anastomosis could have various biomechanical conditions. To do that, biomechanical system of gastrointestinal soft tissue should be examined to control the anastomotic condition. In this study, a new intelligent robot used in circular anastomosis. The intelligent robot driven by a stepper motor and controlled by a digital signal processor.

  • PDF

Analysis of Biomechanical Changes According to Mechanical Alignment of the Lower Limbs when Gait with a Material Handling (중량물 취급 보행 시 하지의 역학적 정렬에 따른 생체역학적 변화 분석)

  • Lee, Kyung-Ill;Lee, Chul-Gab;Song, Han-Soo;Hong, Wan-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.183-190
    • /
    • 2015
  • Objective : Walking with a Material handling is an activity frequently undertaken by agricultural workers in Korea, due to the nature of their work. This study aimed to investigate differences in biomechanical variables according to the mechanical alignment of the lower limbs when walking with a heavy load, and to use this as basic data in the design of various working environments to reduce the skeletomuscular burden on the knee joint. Method : The study subjects comprised of 22 right-foot dominant adult men and women aged between 20 and 23 years. The subjects were divided into a varus or valgus group according to the mechanical alignment of the lower limb by using radiographic findings. The subjects walked without any load and with a load of 10%, 20%, or 30% of their body weight held in front of them. The Kwon3d XP program was used to calculate biomechanical variables. Results : The flexion/extension moment of the knee joint showed a decreasing trend with increased load, irrespective of the mechanical alignment of the lower limb, while the varus group did not show normal compensatory action when supported by one leg at the point of maximum vertical ground reaction force. In addition, in terms of the time taken, subjects showed no difficulties in one-foot support time up to 20%/BW, but at 30%/BW, despite individual differences, there was an increase in single limb. The increased load resulted in a decrease in the ratio of standing phase to ensure physical stability. The valgus group showed a trend of increasing the stability of their center of mass with increasing load, through higher braking power in the early standing phase. Conclusion : In conclusion, although there was no statistical difference in biomechanical variables according to the mechanical alignment of the lower limbs, the varus group showed a more irregular walking pattern with a Material handling than the valgus group, partially proving the association between lower limb alignment and walking with a Material handling.