PPG 신호의 동잡음 구간 검출에 관한 연구 (Study on the Detection the Section with the Motion Artifacts of the PPG Signal)

  • 이한욱;이건기
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.1-6
    • /
    • 2016
  • The biomedical information (heart rate, HRV, $SpO_2$ etc) from the Photoplethysmography (PPG) signal section can be estimated without the motion artifacts if the PPG signal section in the motion artifacts is detected accurately. But the PPG signal is easily exposed to the motion artifacts by the decrease of the medical instrument size and applying as portable or wearable. Besides, it is difficult to completely eliminate the motion artifacts from the PPG signal without distortion and ensure reliability as well. In this paper, the method was suggested to determine the motion artifacts or not on the PPG signal of the section divided into intervals of constant length. By comparing the spectrum of each section, it can be determined whether the motion artifacts are or not after obtaining the spectrum of each section by the Goertzel algorithm. Moreover, an amount of computation while maintaining a high detection rate can be reduced by using the Goertzel algorithm.

Multidimensional Adaptive Noise Cancellation of Stress ECG Signal

  • Gautam, Alka;Lee, Young-Dong;Chung, Wan-Young
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.285-288
    • /
    • 2008
  • In ubiquitous computing environment the biological signal ECG (Electrocardiogram signal) is usually recorded with noise components. Adaptive interference (or noise) canceller do adaptive filtering of the noise reference input to maximally match and subtract out noise or interference from the primary (signal plus noise) input thereby adaptively eliminate unwanted interference from the ECG signal. Measured Stress ECG (or exercise ECG signal) signal have three major noisy component like baseline wander noise, motion artifact noise and EMG (Electro-mayo-cardiogram) noise. These noises are not only distorted signal but also root of incorrect diagnosis while ECG data are analyzed. Motion artifact and EMG noises behave like wide band spectrum signals, and they considerably do overlapping with the ECG spectrum. Here the multidimensional adaptive method used for filtering which is more effective to improve signal to noise ratio.

  • PDF

Detection of Neuronal Activity by Motion Encoding Gradients: A Snail Ganglia Study

  • Park, Tae-S.;Park, Ji-Ho;Cho, Min-H.;Lee, Soo-Y.
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.24-28
    • /
    • 2007
  • Presuming that firing neurons have motions inside the MRI magnet due to the interaction between the neuronal magnetic field and the main magnetic field, we applied motion encoding gradients to dissected snail ganglia to observe faster responding MRI signal than the BOLD signal. To activate the snail ganglia in synchronization with the MRI pulse sequence, we used electrical stimulation with the frequency of 30 Hz and the pulse width of 2s. To observe the fast responding signal, we used the volume selected MRI sequence. The magnetic resonance signal intensity, measured with 8 ms long motion encoding gradient with a 20mT/m gradient strength, decreased about $3.46{\pm}1.48%$ when the ganglia were activated by the electrical stimulation.

생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리 (Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device)

  • 이한욱;이주원;정원근;김성후;이건기
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

다중 생체 신호를 이용한 심장 자기공명영상 스마트 트리거 시스템 (Multi-biological Signal-based Smart Trigger System for Cardiac MRI)

  • 양영중;박진호;홍혜진;안창범
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.945-949
    • /
    • 2014
  • In cardiac magnetic resonance imaging (CMRI), heart and respiratory motions are one of main obstacles in obtaining diagnostic quality of images. To synchronize CMRI to the physiological motions, ECG and respiratory gatings are commonly used. In this paper multi-biological signal (ECG, respiratory, and SPO2) based smart trigger system is proposed. By using multi-biological signal, the proposed system is robust to the induced noise such as eddy current when gradient pulsing is continuously applied during the examination. Digital conversion of the multi-biological signal makes the system flexible in implementing smart and intelligent algorithm to detect cardiac and respiratory motion and to reject arrhythmia of the heart. The digital data is used for real-time trigger, as well as signal display, and data storage which may be used for retrospective signal processing.

RLSL 적응선형예측필터를 이용한 형성음 및 조음운동궤적 추정에 관한 연구 (A Study on Estimation of Formants and Articulatory Motion Trajectories using RLSL Adaptive Linear Prediction Filter)

  • 김동준;송영수
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.1-8
    • /
    • 1993
  • In this study, the extractions of formants and articulatory motion trajectories for Korean complex vowels are performed by using the RLSL adaptive linear prediction filter. This enables us to extract accurate spectrum in transition of speech signal. This study shows that the RLSL algorithm is superior to the Levinson algorithm, specially in transition part of speech.

  • PDF

펄스 옥시메터의 동잡음 제거 필터 설계 (Filter Design to Eliminate Motion Artifact of Pulse Oximetery)

  • 이주원;이종희;강익태;김경하;이건기
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권5호
    • /
    • pp.431-438
    • /
    • 2001
  • 동맥혈액의 총 혈색소 농도와 산화 혈색소 농도의 비율로 정의되는 산소포화도를 비관혈적으로 측정하는 펄스 옥시메터는 주위환경 요인과 피측정자의 호흡 및 움직임에 의한 영향을 받는다. 특히 환자가 움직였을 때 동잡음 신호는 주파수영역에서 정상적인 수신광 신호와 중첩 또는 인접하게 나타나 잡음제거가 어렵다 이러한 문제점을 개선하기 위해 본 논문에서는 필터뱅크와 정합필터를 이용하여 동잡음을 제거하기 위한 방법을 제안한다. 그리고 제안된 방법으로 실험한 결과. ratio의 평균 변화율이 이동평균필터(11.2%)와 적응필터(39.7%)를 이용하였을 때 보다 변화 폭이 4.1%로 나타나 환자의 움직임에서도 보다 안정적인 산소포화도를 측정이 가능할 것으로 사료된다.

  • PDF

Application of Multiple Fuzzy-Neuro Controllers of an Exoskeletal Robot for Human Elbow Motion Support

  • Kiguchi, Kazuo;Kariya, Shingo;Wantanabe, Keigo;Fukude, Toshio
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권1호
    • /
    • pp.49-55
    • /
    • 2002
  • A decrease in the birthrate and aging are progressing in Japan and several countries. In that society, it is important that physically weak persons such as elderly persons are able to take care of themselves. We have been developing exoskeletal robots for human (especially for physically weak persons) motion support. In this study, the controller controls the angular position and impedance of the exoskeltal robot system using multiple fuzzy-neuro controllers based on biological signals that reflect the human subject's intention. Skin surface electromyogram (EMG) signals and the generated wrist force by the human subject during the elbow motion have been used as input information of the controller. Since the activation level of working muscles tends to vary in accordance with the flexion angle of elbow, multiple fuzzy-neuro controllers are applied in the proposed method. The multiple fuzzy-neuro controllers are moderately switched in accordance with the elbow flexion angle. Because of the adaptation ability of the fuzzy-neuro controllers, the exoskeletal robot is flexible enough to deal with biological signal such as EMG. The experimental results show the effectiveness of the proposed controller.

Representation Techniques for 4-Dimensional MR Images

  • Homma, Kazuhiro;Takenaka, Kenji;Nakai, Yoshihiko;Hirose, Takeshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.429-431
    • /
    • 2002
  • Metabolic analysis of biological tissues, the interventional radiology in MRT (Magnetic Resonance Treatment) and for clinical diagnoses, representation of 4-Dimensional (4D) structural information (x,y,z,t) of biological tissues is required. This paper discusses image representation techniques for those 4D MR Images. We have proposed an image reconstruction method for ultra-fast 3D MRI. It is based on image interpolation and prediction of un-acquired pictorial data in both of the real and the k-space (the acquisition domain in MRI). A 4D MR image is reconstructed from only two 3D MR images and acquired a few echo signals that are optimized by prediction of the tissue motion. This prediction can be done by the phase of acquired echo signal is proportioned to the tissue motion. On the other hand, reconstructed 4D MR images are represented as a 3D-movie by using computer graphics techniques. Rendered tissue surfaces and/or ROIs are displayed on a CRT monitor. It is represented in an arbitrary plane and/or rendered surface with their motion. As examples of the proposed representation techniques, the finger and the lung motion of healthy volunteers are demonstrated.

  • PDF

CDMA망 기반 3채널 심전도 모니터링 시스템의 평가 (Evaluation of CDMA Network Based Wireless 3 Channel ECG Monitoring System)

  • 홍주현;차은종;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권4호
    • /
    • pp.295-301
    • /
    • 2008
  • A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.