• Title/Summary/Keyword: Biologic width

Search Result 25, Processing Time 0.03 seconds

Clinical Cases on the Restorative Procedure Preserving the Biologic Width (생물학적 폭경을 고려한 보철임상 증례)

  • Kim, Jeong-Ho
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.28-35
    • /
    • 1999
  • The preservation of a healthy periodontal attachment is the most significant factor in the long-term prognosis of a restored tooth. The 'Biologic Width' is composed of the connective tissue attachment and the epithelial attachment in the dentogingival junction. The violation of the biologic width may result in a progressive inflammatory process and crestal bone loss. So a careful soft tissue management is needed to preserve it for the gingival health and an esthetic restoration. The following clinical cases show the five different situations of the violation of the biologic width and their management.

  • PDF

Consideration of Vertical Position for predictable posterior implant - Deep implantation for Implant Biologic width (예지성 있는 구치부 임플란트를 위한 임플란트의 수직적 깊이에 대한 고려 Implant Biologic width를 위한 Deep Implantation)

  • Yun, Woo-Hyuk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.27-41
    • /
    • 2019
  • For predictable posterior implants, appropriate soft tissue thickness, called the biologic width, is required around the implant for crestal bone stability. In order to do so, it seems that there are many cases where the implant should be positioned deeper than the depth that we previously thought was appropriate or inevitable limit. I would like to share my clinical experience about the vertical position of the posterior implant with the case reports and the related surgical technique.

The significance of soft tissue for maintenance of prosthesis (보철 건강유지를 위한 연조직의 중요성)

  • Kim, Ok-Su
    • The Journal of the Korean dental association
    • /
    • v.48 no.9
    • /
    • pp.664-669
    • /
    • 2010
  • All prosthetic and restorative therapies require a healthy periodontium as a prerequisite for success. Understanding of the concepts of periodontal-restrorative interaction, especially with regard to interactions at the gingival margin is important. The aim of this article gives the information about the essential considering factor for successful prosthesis; biologic width, periodontal biotype, width of attached gingiva, margin of restoration. If a restorative margin must be extended below the gingival margin, it is critical that adequate band of attached gingiva is present, the margin does not violate the biologic width, the margin is closed and properly finished.

An esthetic appliance for the management of crown-root fracture: a case report

  • Jeon, Sang-Min;Lee, Kang-Hee;Jung, Bock-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.226-229
    • /
    • 2014
  • Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

Treatment of crown-root fracture with a modified crown fragment reattachment technique (변형된 치관부 파절편 재부착술식을 이용한 치관치근파절의 치료)

  • Song, Chang-Won;Song, Min-Ju;Shin, Su-Jung;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • The development of adhesive dentistry has allowed that the crown fragment reattachment can be another option in the treatment of crown fracture. However, additional crown lengthening procedure or extrusion of the tooth may be necessary in the treatment of crown root fracture because subgingival fracture line in close proximity to the alveolar bone leads to challenges for restorative procedure and the violation of the biologic width. This case report presents a modified crown fragment reattachment technique of crown root fracture with pulp exposure, which was done without additional crown lengthening procedures. After the endodontic treatment, the patient was treated using a post insertion and the fragment reattachment technique, which made it possible to preserve the space for the biologic width and maintain a dry surgical field for adequate adhesion through the modification of the fractured coronal fragment. Since a coronal fracture was occurred and reattached afterward, it was observed that the coronal fragment was well maintained without the additional loss of periodontal attachment through 2-year follow up.

Periodontal plastic surgery for anterior esthetics (전치부 심미치주성형술)

  • Lee, Yong-Moo
    • The Journal of the Korean dental association
    • /
    • v.48 no.12
    • /
    • pp.880-888
    • /
    • 2010
  • Periodontal disease, trauma, deformity of tooth can jeopardize the esthetics of oral and maxillo-facial region. Moreover, increasing the demand and concern about the esthetics, clinicians should place high value on esthetics during periodontal treatment. Analysis of various anatomical considerations; lip line, shape and location of marginal gingiva, and biologic width; and diagnosis should be performed prior to periodontal plastic surgery.

Distraction osteogenesis in collapsed mandible arch patients by accidents (사고에 의해 하악골 폭경이 붕괴된 환자에서 견인골 신장술)

  • Tae, Ki-Chul;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.33 no.2 s.97
    • /
    • pp.85-90
    • /
    • 2003
  • The symphyseal mandibular fractures due to accidents happened in form of collapsed transeverse arch and multiple teeth loss. And the collapsed transverse arch in mandible occurs with unilaterally or bilaterally. So that patient needs to recover arch width. Conventional approaches, however, we difficult to get appropriate transverse arch correction. Distraction osteogenesis is a unique form of clinical tissue engineering and biologic process of new bone formation between bone segments that are gradually separately by incremental traction. Distraction osteogenesis is considered that great potential for correcting transverse mandibular deficiencies. Tn this paper, distraction osteogenesis applied to patients who had a unilateral or bilateral collapsed arch width in mandible. But it was necessary secrutinize consideration about periodontal conditions, biomechanical vectors, TMJ adaptations, and neuromuscular change during distraction osteogenesis period.