• 제목/요약/키워드: Biohazard

검색결과 17건 처리시간 0.021초

실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구 (A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion)

  • 최상곤;이현우;홍진관
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.

대학 연구실 사고데이터의 통계분석을 통한 안전관리 가이드라인 도출에 대한 연구 (A study on deriving safety management guidelines through statistical analysis of accident data in university labs)

  • 서재신;강주혁;윤영근;오태근
    • 문화기술의 융합
    • /
    • 제8권4호
    • /
    • pp.323-330
    • /
    • 2022
  • 대학 연구실 내 다양한 화학적, 물리학적, 생물학적 유해위험요인들로 인해 안전사고는 꾸준히 발생하고 있으며 이를 개선하기 위한 정부 정책하에 각 대학은 연구실 사전유해위험인자 도출, 연구환경측정 등 다양한 노력을 하고 있다. 본 연구에서는 2016-2020년간 종합대학 연구실 사고사례 192건에 대한 통계 및 교차분석을 통해 사고 발생의 경향 및 관련 인자들의 상관관계를 도출하였다. 주요 인자별 상관관계로부터 대응 방향과 전략을 마련하였으며 연구실 사고에 대한 기존의 정책 방향을 비교·분석하여 연구실 안전관리제도의 개선방향을 제시하였다.

금속가공유 취급 작업장의 생물학적 인자 노출평가 (Microbial Assessment in Metal-Working Fluids Handling Industry)

  • 박현희;박동진;박해동
    • 한국산업보건학회지
    • /
    • 제24권3호
    • /
    • pp.300-309
    • /
    • 2014
  • Objectives: The objective of this study is to evaluate microbial exposure hazards in the metal-working fluids(MWF) handling industry. Methods: Air quality parameters(airborne bacteria, fungi, endotoxin and oil mist) and bulk MWF in storage tanks were evaluated at 54 points at nine sites in South Korea. Results: The geometric means(GM) of culturable airborne bacteria, fungi, endotoxin and oil mist concentration were $133CFU/m^3$(n=376, range $7{\sim}6,510CFU/m^3$), $159CFU/m^3$(n=381, range $7{\sim}8,469CFU/m^3$), $8.06EU/m^3$(n=103, range $0.34{\sim}280.4EU/m^3$) and $0.20mg/m^3$(n=104, range $0.01{\sim}2.87mg/m^3$), respectively. The ratio of indoor to outdoor concentration was 2.7 for bacteria, 6.1 for endotoxin, and 4.8 for oil mist. Even though average airborne bacteria concentration did not exceed recommended exposure limits($1,000CFU/m^3$), MWF in the storage tanks was highly contaminated with bacteria(arithmetic mean $2.1{\times}10^6CFU/ml$) and exceeded recommended bacteria limits($10^5CFU/ml$). Conclusions: It is necessary for MWF handling workplaces to conduct periodical biohazard inspection of MWF storage tanks. Additionally, further research may be necessary to establish biological occupational exposure limits.

Biorisk Assessment of Medical Diagnostic Laboratories in Nigeria

  • Oladeinde, Bankole Henry;Omoregie, Richard;Odia, Ikponmwonsa;Osakue, Eguagie Osareniro;Imade, Odaro Stanley
    • Safety and Health at Work
    • /
    • 제4권2호
    • /
    • pp.100-104
    • /
    • 2013
  • Background: The aim of this study was to assess public and private medical diagnostic laboratories in Nigeria for the presence of biosafety equipment, devices, and measures. Methods: A total of 80 diagnostic laboratories in biosafety level 3 were assessed for the presence of biosafety equipment, devices, and compliance rate with biosafety practices. A detailed questionnaire and checklist was used to obtain the relevant information from enlisted laboratories. Results: The results showed the presence of an isolated unit for microbiological work, leak-proof working benches, self-closing doors, emergency exits, fire extinguisher(s), autoclaves, and hand washing sinks in 21.3%, 71.3%, 15.0%, 1.3%, 11.3%, 82.5%, and 67.5%, respectively, of all laboratories surveyed. It was observed that public diagnostic laboratories were significantly more likely to have an isolated unit for microbiological work (p = 0.001), hand washing sink (p = 0.003), and an autoclave ($p{\leq}0.001$) than private ones. Routine use of hand gloves, biosafety cabinet, and a first aid box was observed in 35.0%, 20.0%, and 2.5%, respectively, of all laboratories examined. Written standard operating procedures, biosafety manuals, and biohazard signs on door entrances were observed in 6.3%, 1.3%, and 3.8%, respectively, of all audited laboratories. No biosafety officer(s) or records of previous spills, or injuries and accidents, were observed in all diagnostic laboratories studied. Conclusion: In all laboratories (public and private) surveyed, marked deficiencies were observed in the area of administrative control responsible for implementing biosafety. Increased emphasis on provision of biosafety devices and compliance with standard codes of practices issued by relevant authorities is strongly advocated.

생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석 (Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory)

  • 황지현;홍진관
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.

반순환여과양식시스템에서 오존 유래 잔류산화물이 넙치(Paralichthys olivaceus) 사육수의 수질과 미생물에 미치는 영향 (Ozone-produced Oxidants Improve Water Quality Parameters and Microbial Colony Counts in the Semi-Recirculating Aquaculture System for Olive Flounder Paralichthys olivaceus)

  • 정상명;박우근;박성덕;박정환;김재원;김병기
    • 한국수산과학회지
    • /
    • 제54권5호
    • /
    • pp.751-760
    • /
    • 2021
  • This study investigated the changes in water quality parameters and microbial colonies when ozone was applied to a semi-recirculating aquaculture system (semi-RAS) for the olive flounder Paralichthys olivaceus (500 g in average weight). Concentrations of ozone-produced oxidants (OPO) in rearing tanks were maintained at 0, 0.014, 0.025 mg/L as Cl2 for 26 days. Except total ammonia nitrogen, nitrite nitrogen, nitrate nitrogen, phosphate phosphorus, chemical oxygen demand, and total suspended solids decreased significantly with increasing OPO concentration in daily and weekly monitoring (P<0.05). Colony forming unit (CFU) counts of heterotrophic marine bacteria decreased in an OPO concentration-dependent manner. Overall reduction rates of microbial colonies in the treatments were 80% higher than those of the control (P<0.05). During the experiment, the OPO concentration-driven ozonation was reliably practiced without any adverse effects on the animals cultured in semi-RAS. Considering the biohazard, operating cost, and stability of ozonation, an OPO concentration of 0.014 mg/L would be sufficient to control water quality parameters and microbial colonies in a semi-RAS.

Assessment of Environmental Pollution in Korean Stream Sediments by Chemical Analyses and Insect Immune Biomarkers

  • Ryoo, Keon-Sang;Byun, Sang-Hyuk;Hong, Yong-Pyo;Cho, Ki-Jong;Bae, Yeon-Jae;Kim, Yong-Gyun
    • 환경생물
    • /
    • 제26권4호
    • /
    • pp.330-342
    • /
    • 2008
  • A comprehensive quality survey for PCDDs/PCDFs and coplanar PCBs as well as heavy metals (Cu, Zn, Cd and Pb) in sediments has been investigated in August 2006, Korea. Monitoring was undertaken at five streams representing different surrounding environments throughout Juwang and Gapyeong streams (reference sites), Jungrang stream (dense population site), Ansan stream (mixed small population and industrial site), and Siheung stream (heavy industrial site). The levels of heavy metal in samples were found to be significantly higher in sediment from Siheung stream compared to those of other stream sites. The heavy metal concentrations (dry weight basis) in sediment from Siheung stream were as follows; Cd (3.7 ${\mu}g$/g), Pb (1,295 ${\mu}g$/g), Cu (713.4 ${\mu}g$/g) and Zn (358.1 ${\mu}g$/g). Among 12 coplanar PCBs and 17 PCDDs/PCDFs selected as target compounds in this study, PCB (IUPAC no. 118) and OCDD were the most abundant congeners found in all sediment samples, followed by 1,2,3,4,6,7,8-HpCDD, OCDF and 1,2,3,4,6,7,8HpCDF as well as PCB (IUPAC no. 105). These results were shown to be in the same trend as the sediment samples of other countries. The levels of PCDDs/PCDFs/coplanar PCBs in sediment samples were expressed as concentrations and WHO- TEQ values. The PCDDs/PCDFs/coplanar PCBs concentrations and their WHO-TEQ values in sediment from Siheung stream were remarkably high. The levels detected were 788.16 pg/g and 36.080 pg WHO-TEQ/g dry weight for PCDDs/ PCDFs and 314 pg/g and 0.4189 pg WHO-TEQ/g dry weight for coplanar PCBs, respectively, beyond the safety level of sediment value 20 pg WHO-TEQ/g. Sediment samples of the five streams were also monitored by sensitive biomarkers using insect immune responses: hemocyte-spreading behavior and immune-associated enzyme activities of phospholipase A$_2$ (PLA$_2$) and phenoloxidase. Organic extracts of Siheung and Jungrang sediments significantly interfered with the hemocytespreading behavior, whereas those of Ansan, Gapyeong, and Juwang did not. These organic extracts did not inhibit the PLA$_2$ and phenoloxidase activities. However, phenoloxidase was highly susceptible to exposure to aqueous extracts in all site sediments. In comparison, PLA$_2$ activities of the hemocytes were significantly inhibited only by aqueous extracts of Siheung, Jungrang, and Gapyeong sediments, but not by those of Ansan and Juwang. Despite some disparity between bioand chemical monitoring results, the biomarkers can be recommended as a device warning the contamination of biohazard environmental chemicals because of a fast and inexpensive detection method.