• Title/Summary/Keyword: Bioelectrical impedance analysis (BIA)

Search Result 49, Processing Time 0.024 seconds

Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results (Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰)

  • Kim, Soo-Byeong;Lee, Na-Ra;Lee, Seung-Wook;Choi, Jun-Young;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

Development of single frequency type body-fat analyzer (단일 주파수 방식 체지방측정기의 개발)

  • Park, Chan-Won;Choi, Byung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2159-2160
    • /
    • 2006
  • 본 논문은 단일주파수의 교류전류를 사용하고 8개의 접촉전극을 이용한 4 전극법방식으로 전신의 BIA (Bioelectrical Impedance Analysis)측정을 최소한의 경제적인 회로를 이용하여 구현한 체지방측정기의 개발에 관한 것이다.

  • PDF

A Chip Design of Body Composition Analyzer (체성분 분석용 칩 설계)

  • Bae, Sung-Hoon;Moon, Byoung-Sam;Lim, Shin-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.3 s.357
    • /
    • pp.26-34
    • /
    • 2007
  • This Paper describes a chip design technique for body composition analyzer based on the BIA (Bioelectrical Impedance Analysis) method. All the functions of signal forcing circuits to the body, signal detecting circuits from the body, Micom, SRAM and EEPROMS are integrated in one chip. Especially, multi-frequency detecting method can be applied with selective band pass filter (BPF), which is designed in weak inversion region for low power consumption. In addition new full wave rectifier (FWR) is also proposed with differential difference amplifier (DDA) for high performance (small die area low power consumption, rail-to-rail output swing). The prototype chip is implemented with 0.35um CMOS technology and shows the power dissipation of 6 mW at the supply voltage of 3.3V. The die area of prototype chip is $5mm\times5mm$.

Application of Segmental Phase Angle for Assessment of Post-Stroke Complex Regional Pain Syndrome (뇌졸중 후 복합부위통증증후군에서 부위별 위상각을 이용한 평가)

  • Park, Se-Heum;Kim, Woo-Jin;Jo, Geun-Yeol;Kwon, Jun-Koo
    • Clinical Pain
    • /
    • v.19 no.1
    • /
    • pp.23-27
    • /
    • 2020
  • Our objective is to evaluate the applicability of segmental phase angle (PhA) via bioelectrical impedance analysis (BIA) for post-stroke complex regional pain syndrome (CRPS). Due to its noninvasiveness and convenience, various studies have used BIA in clinical conditions. We measured segmental PhA in 4 patients at the time of CRPS diagnosis and repeated 4 weeks after 2 weeks of steroid pulse therapy. In 3 cases, the affected-to-unaffected ratio of the upper limb PhA decreased at the time of diagnosis. In 2 cases with improvement of more than 5 points in the CRPS severity score (CSS), increased ratios were observed. In other 2 cases with improvement of less than 4 points in the CSS, no remarkable changes in the ratios were found. We suggest that the segmental PhA can be helpful in assessment of post-stroke CRPS and its recovery.

The Suggestion of MF BIA Analyzer Method to Reflect the Resistance in the Extracelluar and Intracelluar Fluid at Acupoint & the Evaluation of Reflection Rate on the Tissue under Skin (MF-BIA Analyzer를 이용한 경혈의 세포 내액과 외액에 의한 저항성분 추정 방법 제시 및 반영률 평가)

  • Kim, Soo-Byeong;Lee, Na-Ra;Kim, Won-Ky;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.4
    • /
    • pp.563-572
    • /
    • 2012
  • Objectives : The aim of this study was to suggest a new method to estimate the resistance by acupoint compositions by using the multi-frequency bioelectrical impedance analysis(MF-BIA) of 5 kHz, 50 kHz and 200 kHz within 2 cm of acupoints as a local segment. Moreover, we try to confirm the relation to between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth. Methods : Ten male subjects participated in this study. We measured the resistance at left/right ST36 at skin surface and various manual acupuncture needle insertion depth(skin, 5 mm, 10 mm, 15 mm, 20 mm, 25 mm and 30 mm). Results : It was also observed that the all measured resistances were the highest at 5 kHz and the lowest at 200 kHz. There were significant differences at 5 kHz, 50 kHz and 200 kHz between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth(p<0.05). There was no significant difference in the left and right identical acupoints under the identical condition(p>0.05). Conclusions : We conclude that the measured resistance at skin surface has limitation as to reflect the information of tissue. However, the measured resistance at each frequency was changed as similar pattern by different insertion depth. Hence, we confirmed the possibility of assumption on information of tissue which was expected to locate an acupoint.

Methodological Comparison between Measured and Predicted Resting Energy Expenditure in Korea Obese Women (비만 여성에서 휴대용 간접 열량계를 통한 실측 휴식 대사량과 예측 휴식 대사량의 비교)

  • Song, Mi-Young;Park, Jung-Mi;Kim, Jin-Ah;Ko, Byeong-Pyo;Lee, Myung-Jong;Kim, Ho-Jun
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.5 no.1
    • /
    • pp.57-66
    • /
    • 2005
  • Objectives : The purpose of this study is to examine accuracy of predicted resting energy expenditure (REE), relationship fat free mass (FFM) and REE. Methods : 60 normal, obese women $(body\;mass\;index\;{\geq}25kg/m^2)$ were recruited for this study, they had low calorie diet for 8 weeks. At week 0, 4, and 8, REE was measured by MedGem (indirect calorimeter), Bioelectrical impedance analysis (BIA) using Cunningham equation, and Harris-Benedict (H-B) equation, FFM was also measured by BIA. Results : The REE predicted by BIA was lower than the REE measured by MedGem (MG) in every measurement. The REE predicted by H-B equation predicted REE was lower than that of MG in the second measurement (p<0.01). The REE measured by MedGem was declined after 8 weeks, BIA and H-B equation predicted REE were declined after 4 weeks (p<0.01). H-B equation predicted REE had more significant correlation with the REE measured by MedGem than that of BIA. There was significant correlation between measured REE and FFM, but measured REE declined after 8 weeks, FFM declined after 4 weeks (p<0.01). We derived a prediction equation as follows : REE = 108.36+31.42 (FFM), $R^2=0.23$.

  • PDF

Reliability and Data Integration of Duplicated Test Results Using Two Bioelectrical Impedence Analysis Machines in the Korean Genome and Epidemiology Study

  • Park, Bo-Young;Yang, Jae-Jeong;Yang, Ji-Hyun;Kim, Ji-Min;Cho, Lisa-Y.;Kang, Dae-Hee;Shin, Chol;Hong, Young-Seoub;Choi, Bo-Youl;Kim, Sung-Soo;Park, Man-Suck;Park, Sue-K.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.6
    • /
    • pp.479-485
    • /
    • 2010
  • Objectives: The Korean Genome and Epidemiology Study (KoGES), a multicenter-based multi-cohort study, has collected information on body composition using two different bioelectrical impedence analysis (BIA) machines. The aim of the study was to evaluate the possibility of whether the test values measured from different BIA machines can be integrated through statistical adjustment algorithm under excellent inter-rater reliability. Methods: We selected two centers to measure inter-rater reliability of the two BIA machines. We set up the two machines side by side and measured subjects' body compositions between October and December 2007. Duplicated test values of 848 subjects were collected. Pearson and intra-class correlation coefficients for inter-rater reliability were estimated using results from the two machines. To detect the feasibility for data integration, we constructed statistical compensation models using linear regression models with residual analysis and R-square values. Results: All correlation coefficients indicated excellent reliability except mineral mass. However, models using only duplicated body composition values for data integration were not feasible due to relatively low $R^2$ values of 0.8 for mineral mass and target weight. To integrate body composition data, models adjusted for four empirical variables that were age, sex, weight and height were most ideal (all $R^2$ > 0.9). Conclusions: The test values measured with the two BIA machines in the KoGES have excellent reliability for the nine body composition values. Based on reliability, values can be integrated through algorithmic statistical adjustment using regression equations that includes age, sex, weight, and height.

The Effect of Management Program of Oriental Medicine for Obesity Control on Overweight and Obese Pediatrics (과체중.비만 소아에 대한 한방비만치료프로그램 효과)

  • Lee, Yoon-Jae;Ryu, Eun-Kyung
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2009
  • Objectives The purpose of this study was to investigate the effect of oriental treatment on pediatric overweight and obesity. Methods From the December 2006 to the May 2008, 19 children were treated of obesity control in J Korean Hospital, electrolipolysis, auricular acupuncture was done 2 times per week for 4 weeks with the consulting of diet and exercise. Nine children were treated for 9 weeks. We checked the change of weight at treatment time and the body composition measured by bioelectrical impedance analysis(BIA) per 2 weeks. Results After 4 weeks treatment, the weight loss was 2.67${\pm}$1.75kg. And after 9 weeks treatment, the weight loss of 9 children was 5.91${\pm}$2.73kg. Total fat mass measured by BIA significantly decreased 2.38${\pm}$1.19kg after 4 weeks. BMI and the weight loss of children were significantly correlated. After 4 weeks treatment the BMI significantly decreased 1.43${\pm}$0.89kg/m$^2$. After 8 weeks treatment the BMI of 9 children significantly decreased 3.31${\pm}$1.47kg/m$^2$. Conclusions The pediatric obesity could be effective treated by herdal medicine and electroacupuncture.

  • PDF

The Change of Weight Loss of Oriental Obesity Treatment (한방비만프로그램의 체중감량 경과 관찰)

  • Lee, Yoon-Jae;Ryu, Eun-Kyung
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.9 no.1
    • /
    • pp.53-58
    • /
    • 2009
  • Objectives The purpose of this study was to investigate the clinical effect of oriental medical therapy on obesity and the progress of weight loss through an oriental obesity program. Methods The subjects were treated from January 2008 to February 2009 in J Korean Medical Hospital. Herbal medical Hospital. Herbal medicine, electrolipolysis, auricular acupuncture were performed during the treatment period. We checked the change of weight every treatment time and measured the body composition by bioelectrical impedance analysis(BIA) every 2 weeks. Results The progress of weight loss was steady in the first 4 weeks except for the sixth weight check. After 4 weeks treatment, the weight loss was 3.52${\pm}$1.98Kg and 4.83${\pm}$2.68%. Total fat mass measured by BIA significantly decreased 2.58${\pm}$1.30Kg after 4 weeks. Age and the weight loss were significantly negative correlated. Conclusions Oriental obesity treatment could be effective on obesity, but further studies would be needed for the foundation of a clinical guideline reflecting various factors.

  • PDF

Analysis of Bioimpedance Change and the Characteristics of Blood Pressure according to Posture (자세에 따른 생체임피던스 변화와 혈압 특성 분석)

  • Cho, Young Chang;Kim, Min Soo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.5
    • /
    • pp.25-31
    • /
    • 2014
  • Bioelectrical Impedance Analysis(BIA) is a widely used method for estimating body composition changes which is a non-invasive, inexpensive, safety and reproductive method. We studied the bioimpedance change and the distinction of blood pressure according to body posture and conducted three kinds of experiments: the real-time bioimpedance measurement, the simulation using equivalent circuit model and the blood pressure measurement. Bioimpedance is measured during 4 minutes at the multi-frequency(1 kHz, 10 kHz, 20 kHz, 50 kHz, 70 kHz, 100 kHz). From the experiment results, the changes in body postures result in changes of resistance and reactance, with an average rapid increase of body impedance when going from standing, sitting to supine. Specially, the laying resistance on average was 16.49% higher than supine resistance at 50 kHz and the laying reactance measurement was also 26.05% higher than sitting reactance at 1 kHz. Blood pressure in standing posture was higher than those in other postures both in maximum($125.14{\pm}12.30$) and in minimum($75.57{\pm}10.31$). The results of BIA and blood pressure in this study will be contributed to the research on acute illness, extreme fat, and body shape abnormalities.