• Title/Summary/Keyword: Biocompatible materials

Search Result 199, Processing Time 0.032 seconds

Thyroplasty Type I using Gore-Tex (고어텍스를 이용한 제1형 갑상연골성형술)

  • Yoo, Young-Sam
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.18 no.1
    • /
    • pp.16-21
    • /
    • 2007
  • Many kinds of materials have been used up to now for vocal fold paralysis. Although silastic block has been the most popular material, some difficulties in carving, positioning, and placing have been the causes to find more easily applicable materials. Hy-droxylapatite, gelfoam, hyaluronic acid and fat have been suggested and used for this purposes with some limitations. During last decade, Gore-Tex was introduced and replacing old materials and showed good surgical results with less difficulties. This material is biocompatible and familiar to surgeons because it had been invented in 1960's. In addition it is easy to shape and place Gore-Tex into the window with many clinical experiences. In some problem cases, it is easy to remove from the body with less damage to surrounding tissue. The basic surgical techniques are as follows. 1) Creating window. 2) Positioning and placing the material. 3) Immobilizing the material and closing the window. The modified methods ae introduced in details with figures.

  • PDF

Analysis of Biocompatible TiO2 Oxide Multilayer by the XPS Depth Profiling

  • Jang, Jae-Myung;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.156-156
    • /
    • 2017
  • In this work, analysis of biocompatible TiO2 oxide multilayer by the XPS depth profiling was researched. the manufacture of the TiO2 barrier-type multilayer was accurately performed in a mixed electrolyte containing HAp, Pd, and Ag nanoparticles. The temperature of the solution was kept at approximatively $32^{\circ}C$ and was regularly rotated by a magnetic stirring rod in order to increase the ionic diffusion rate. The manufactured specimens were carefully analyzed by XPS depth profile to investigate the result of chemical bonding behaviors. From the analysis of chemical states of the TiO2 oxide multilayer using XPS, the peaks are showed with the typical signal of Ti oxide at 459.1 eV and 464.8 eV, due to Ti 2p(3/2) and Ti 2p(1/2), respectively. The Pd-3d peak was split into Pd-3d(5/2) and Pd-3d(3/2)peaks, and shows two bands at 334.7 and 339.9 eV for Pd-3d3 and Pd-3d5, respectively. Also, the peaks of Ag-3d have been investigated. The chemical states consisted of the O-1s, P-2p, and Ti-2p were identified in the forms of PO42- and PO43-. Based on the results of the chemical states, the chemical elements into the TiO2 oxide multilayer were also inferred to be penetrated from the electrolyte during anodic process.The structure characterization of the modified surface were performed by using FE-SEM, and from the result of biological evaluation in simulated body fluid(SBF), the biocompatibility of TiO2 oxide multilayer was effective for bioactive property.

  • PDF

Antibacterial mesoporous Sr-doped hydroxyapatite nanorods synthesis for biomedical applications

  • Gopalu Karunakaran;Eun-Bum Cho;Keerthanaa Thirumurugan;Govindan Suresh Kumar;Evgeny Kolesnikov;Selvakumar Boobalan
    • Advances in nano research
    • /
    • v.14 no.6
    • /
    • pp.507-519
    • /
    • 2023
  • Postsurgical infections are caused by implant-related pathogenic microorganisms that lead to graft rejection. Hence, an intrinsically antibacterial material is required to produce a biocompatible biomaterial with osteogenic properties that could address this major issue. Hence, this current research aims to make strontium-doped hydroxyapatite nanorods (SrHANRs) via an ethylene diamine tetraacetic acid (EDTA)-enable microwave mediated method using Anodontia alba seashells for biomedical applications. This investigation also perceives that EDTA acts as a soft template to accomplish Sr-doping and mesoporous structures in pure hydroxyapatite nanorods (HANRs). The X-ray diffraction (XRD) and transmission electron microscopy (TEM) analysis reveals the crystalline and mesoporous structures, and Brunauer-Emmett-Teller (BET) indicates the surface area of all the samples, including pure HANRs and doped HANRs. In addition, the biocidal ability was tested using various implant-related infectious bacteria pathogens, and it was discovered that Sr-doped HANRs have excellent biocidal properties. Furthermore, toxicity evaluation using zebrafish reports the non-toxic nature of the produced HANRs. Incorporating Sr2+ ions into the HAp lattice would enhance biocompatibility, biocidal activity, and osteoconductive properties. As a result, the biocompatible HANRs materials synthesized with Sr-dopants may be effective in bone regeneration and antibacterial in-built implant applications.

New Material and Processing Issues for High Quality Parts by Micro-MIM

  • Rota, A.;Imgrund, Ph.;Haack, J.;Petzoldt, F.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.34-35
    • /
    • 2006
  • The development of Micro MIM as a new manufacturing process for metallic micro parts made of advanced functional materials has been the subject of considerable research over the last years. This paper addresses important quality aspects on processing of new materials by Micro-MIM. Three examples of new functional materials that can be processed are reviewed in this paper. The first example is two-component-Micro-MIM to obtain multi-functional devices. A micro positioning encoder consisting of a magnetic / non-magnetic material combination is presented. The second issue is series production of the replicate of the smallest human bone in the ear (stapes) from Titanium as an example of medical application. Quality assurance and reproducibility in terms of injection moulding parameters are addressed. In the third part, first results on the processing of the shape memory alloy NiTi by Micro-MIM are presented. Potential applications include biocompatible devices and transportation, for example automotive and aerospace. Processing routes and initial microstructures obtained are discussed.

  • PDF

Surface Chemistry in Biocompatible Nanocolloidal Particles (생체 적합한 나노입자와 계면화학)

  • Kim Jong-Duk;Jung Jae Hyun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.3 s.47
    • /
    • pp.295-305
    • /
    • 2004
  • Colloid and surface chemistry have been focused on surface area and surface energy. Local surface properties such as surface density, interaction, molecular orientation and reactivity have been one of interesting subjects. Systems of such surface energy being important would be listed as association colloid, emulsion, particle dispersion, foam, and 2-D surface and film. Such nanoparticle systems would be applied to drug delivery systems and functional cosmetics with biocompatible and degradable materials, while nanoparticles having its size of several nm to micron, and wide surface area, have been accepted as a possible drug carrier because their preparation, characteristics and drug loading have been inves-tigated. The biocompatible carriers were also used for the solubilization of insoluble drugs, the enhancement of skin absorption, the block out of UV radiation, the chemical stabilization and controlled release. Nano/micro emulstion system is classified into nano/microsphere, nano/microcapsule, nano/microemulsion, polymeric micelle, liposome according to its prep-aration method and size. Specially, the preparation method and industrial applications have been introduced for polymeric micelles self-assembled in aqueous solution, nano/microapsules controlling the concentration and activity of high concen-tration and activity materials, and monolayer or multilayer liposomes carrying bioactive ingredients.

Optimization Research of 3D Printer Associated with Properties of Photocurable Resins for Ocular Prosthesis Producing (의안 제작을 위한 광경화 방식 3D 프린터에 적용 가능한 소재 선정 및 장비 최적화를 위한 실험적 연구)

  • Kim, So Hyun;Yoon, Jin Sook;Yoo, Sun Kook
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.55-61
    • /
    • 2019
  • Recently, various researches on materials and equipment have been actively conducted to overcome the limitations of conventional output methods due to the increase of diversity of 3D printing materials and to adopt an output method suitable for the characteristics of each material. As the range applicable to outputable materials is expanded, manufacturing of medical devices applied to patients is in a more rapid growth trend than other fields. In this study, we investigated the suitable materials for fabricating 3D printer using photocurable resin. As a result, one suitable material was selected through biological safety experiment and thermal stability experiment. Next, to optimize the output of the selected materials, we have developed a system that optimizes the equipment according to the characteristics of the material. The results of this study enabled the implementation of personalized medical implants that could not be made from 3D printer dependent materials, thereby overcoming the limitations of existing 3D printer output conditions and dedicated materials.

Flow Characteristics of Elastin-Like Polypeptide(ELP) Coated Packed Bed (온도 감응성 폴리펩티드로 표면 처리된 충전층의 유동 특성)

  • Kim, Duck-Jong;Lee, Jong-Hwan;Park, Sang-Jin;Hyun, Jin-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3187-3190
    • /
    • 2007
  • Elastin-Like polypeptide (ELP) composed of elastin-based repeating units is an artificial biomaterial which is biocompatible and non-immunogenic. ELP shows a characteristic inverse phase transition between hydrophobic and hydrophilic phase by external stimuli such as salt, pH and temperature. In this study, ELP coated PS (polystyrene) beads are packed in tubing and the thermo -responsive flow characteristics of the packed bed are investigated. Preliminary test results show that the control of the fluid flow can be achieved by using the temperature driven phase transition effect of the ELP coated beads in a microchannel.

  • PDF

Rheological Properties of High Molecular Weight (HMW) Syndiotactic poly(vinyl alcohol) (PVA)/HMW Atactic PVA Blend Solutions (고분자량 교대배열 폴리비닐알코올/고분자량 혼성배열 폴리비닐알코올 블렌드 용액의 유변학적 특성)

  • Yeum, Jeong-Hyun;Ji, Byung-Chul;Lyoo, Won-Seok
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.74-75
    • /
    • 2003
  • Recently, people are gradually concerned about environmental issue, bionics, environmental-friendly or biocompatible materials. Poly(vinyl alcohol) (PVA) is suitable for these materials, because it is typically water-soluble polymer that have linear-flexible chains, a material of no toxicity for human, and biodegradable polymer[1]. One of the most effective factors that dominate the properties of PVAs is tacticity. (omitted)

  • PDF

Synthesis of ABA-type Block Copolymer of Trimethylene Carbonate and $\varepsilon$-caprolactone (Trimethylene Carbonate와 $\varepsilon$-caprolactone를 이용한 ABA 형태 공중합체 합성에 관한 연구)

  • Yong Tang Jia;Hak Yong Kim;Douk Rae Lee;Ding Bin;Narayan Bhattarai
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.341-344
    • /
    • 2001
  • Over the last 20 years, biodegradable materials in medical applications have been studied extensively. Among these materials, poly(ε-caprolactone) and poly(trimethylene carbonate)(PTMC) are attractive biopolymers to be used as biodegradable sutures, artificial skin, drug release system. It was known that PCL is a nontoxic biocompatible semicrystalline polymer with melting point of 63℃, and PTMC is an amorphous or little crystaline polymer. (omitted)

  • PDF

APPLICATION OF FIBRIN ADHESIVE IN DISK REPLACEMENT AFTER MENISCECTOMY (관절원판 절제술후 중간삽입물 고정에 피브린 접착제의 응용)

  • Chung, Hoon;Kim, Hyeong-Keun;Kim, Young-Soo;Yu, Ki-Jun;Ahn, Byoung-Guen
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.3
    • /
    • pp.175-184
    • /
    • 1992
  • Meniscectomy is indicated for the internal derangement of disk with perforation and gross morphological changes, nonreactive to conservative treatment procedures. After the meniscectomy, permanent disk replacement can be followed. Variable materials have been introduced for disk replacement. Of them, relatively harder replacing materials should have been fixed with surgical wire only. This poor fixation method provide inadequate retentive force and conclusively can be attributed to postoperative noise, poor prognosis. We tried to use biocompatible fibrin adhesive in order to obtain additional fixation force in the method above mentioned and treated two patients with the late stage of internal derangement of disk In both cases, satisfactory results were obtained.

  • PDF