• 제목/요약/키워드: Biochemical oxygen demand (BOD)

검색결과 182건 처리시간 0.022초

하천·호소의 유기물 지표 평가 (Index of Organic Matter in Stream and Lake)

  • 유순주;황종연;윤영삼;천세억;한의정
    • 환경영향평가
    • /
    • 제8권1호
    • /
    • pp.81-92
    • /
    • 1999
  • This study discussed the appropriateness of organic matter indexes such as biochemical oxygen demand(BOD) and chemical oxygen demand with potassium permanganate($COD_{Mn}$) in water quality environmental standard of streams and lakes and the applicability of the items to water quality environmental standard to add or substitute COD with potassium dichromate ($COD_{Cr}$) and total organic carbon(TOC) being used as index of organic matter. And indexes of organic matter content and organic carbon concentration were distinguished between dissolved and particulate component in water sample to estimate their effect on pollutants loading in lake and stream. The ratio of $COD_{Cr}$/BOD was 5.1 under BOD concentration 3mg/L in river water quality environmental standard II, and 2.67 above it. This ratio was diminished to 2.04 when BOD concentration was more than 8mg/L, in river quality environmental standard IV. Also the ratio of $COD_{Mn}$/BOD showed 2.16 under 3mg/L(BOD), and 1.1 above it. This ratio is also diminished to 0.84 over 8mg/L(BOD). Accordingly, we should apply this ratio depending on the concentration level to add and change organic matter index of water quality environmental standard newly. The ratio $COD_{Cr}/COD_{Mn}$ both in lake and stream shows 2.37(r=0.986, p<0.001). But the ratios showed range of 2.34~2.50, which is no much difference of this ratio according to $COD_{Mn}$ concentration.

  • PDF

Environmental Assessments of Leachate from Medium Density Fiberboard in a Simulated Landfill

  • Lee, Min;Prewitt, Lynn;Mun, Sung Phil
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.548-557
    • /
    • 2015
  • This study investigated environmental assessments of leachate containing formaldehyde from medium density fiberboard (MDF) disposed in laboratory-scale simulated landfills. Environmental impact assessment of leachate was conducted by measuring formaldehyde, toxicity, biochemical oxygen demand (BOD), chemical oxygen demand (COD), bacterial enumeration, and pH. Amount of formaldehyde in leachate from MDF in soil decreased to the level of soil only treatment by 28 days, and toxicity decreased as the amount of formaldehyde decreased. BOD and COD levels in leachate from the treatments containing MDF exceeded permissible discharge levels of BOD or COD throughout the experimental period. The pH levels of all treatment were within permissible discharge range except on day 0. Fewer bacteria were observed in leachate from MDF in soil treatment than other treatments (MDF only, cured UF resin in soil, and soil only). Consequently, the leachate from disposal of MDF in soil detrimentally affect on environment. However, soil buffered formaldehyde leaching and pH on leachate in this study. Waste MDF may be required the pre-water soaking treatment for leaching formaldehyde to reclaim on land.

하천수내 TOC 농도 추정을 위한 단순회귀모형과 다중회귀모형의 개발과 평가 (Development and Evaluation of Simple Regression Model and Multiple Regression Model for TOC Contentation Estimation in Stream Flow)

  • 정재운;조소현;최진희;김갑순;정수정;임병진
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.625-629
    • /
    • 2013
  • The objective of this study is to develop and evaluate simple and multiple regression models for Total Organic Carbon (TOC) concentration estimation in stream flow. For development (using water quality data in 2012) and evaluation (using water quality data in 2011) of regression models, we used water quality data from downstream of Yeongsan river basin during 2011 and 2012, and correlation analysis between TOC and water quality parameters was conducted. The concentrations of TOC were positively correlated with Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), TN (Total Nitrogen), Water Temperature (WT) and Electric Conductivity (EC). From these results, simple and multiple regression models for TOC estimation were developed as follows : $TOC=0.5809{\times}BOD+3.1557$, $TOC=0.4365{\times}COD+1.3731$. As a result of the application evaluation of the developed regression models, the multiple regression model was found to estimate TOC better than simple regression models.

미생물막 전극을 이용한 BOD 자동화 측정장치 (Automatic On-line BOD Measurement System Using A Microbial Membrane Electrode)

  • 오혁;김해동
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.335-340
    • /
    • 1995
  • Bacillus subtilis와 PVA를 사용한 미생물막 전극을 이용하여 수질시료의 생화학적 산소요구량(BOD)을 측정할 수 있는 BOD 자동화 측정장치를 개발하였다. 본 연구에서 개발한 BOD 자동화 측정장치는 glucose/glutamic acid BOD 표준용액을 사용시 60ppm까지 직선적인 감응을 나타내었으며, 시료주입 후 10분 이내에 자동으로 BOD 측정기능을 수행하였다. Bacillus subtilis와 PVA를 사용한 미생물막 전극의 감응시간과 회복시간은 각각 5분이었으며, BOD 측정 정장치의 자동화에 의하여 10% 오차내에서 재현성 있는 결과를 얻을 수 있었다.

  • PDF

Phosphorus Removal in Pilot Plant Using Biofilm Filter Process from Farm Wastewater

  • Shin, Sung-Euy;Choi, Du-Bok;Lee, Choon-Boem;Cha, Wol-Suk
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권4호
    • /
    • pp.325-331
    • /
    • 2006
  • Various environmental conditions affecting total phosphorus removal from farm wastewater in a biofilm filter process were investigated using loess balls and Chromobacterium LEE-38 at a pilot plant. When Chromobacterium LEE-38 was used, the removal efficiency of total phosphorous was approximately 10- or 5-fold higher than that of Acinetobacter CHA-2-14 or Acinetobacter CHA-4-5, respectively. When a loess ball of $11{\sim}14mm$ manufactured at a $960^{\circ}C$ calcining temperature was used, the removal efficiency of total phosphorous was 90.0%. When 70% of the volume fraction was used, the maximum efficiency of total phosphorus removal was 93.1%. Notably, when the initial pH was in the range of 6.0 to 8.0, the maximum removal efficiency of total phosphorus was obtained after 30 days. When the operating temperature was in the range of 30 to $55^{\circ}C$, the maximum removal efficiencies of total phosphorus, 95.6 to 94.6%, were obtained. On the other hand, at operating temperatures below $20^{\circ}C$ or above $40^{\circ}C$, the removal efficiency of total phosphorous decreased. Among the various processes, biofilm filter process A gave the highest removal efficiency of 96.4%. Pilot tests of total phosphorus removal using farm wastewater from the biofilm filter process A were carried out for 60 days under optimal conditions. When Acinetobacter sp. Lee-11 was used, the average removal efficiency in the p-adsorption area was only 32.5%, and the removal efficiencies of chemical oxygen demand (COD) and biological oxygen demand (BOD) were 56.7 and 62.5%, respectively. On the other hand, when Chromobacterium LEE-38 was used, the average removal efficiency was 95.1%, and the removal efficiencies of COD and BOD were 91.3 and 93.2%, respectively.

광주지역 영산강의 NBOD 발생에 대한 암모니아성 질소 및 미생물 영향 연구 (Effect of ammonia nitrogen and microorganisms on the elevated nitrogenous biochemical oxygen demand (NBOD) levels in the Yeongsan river in Gwangju)

  • 장동;조광운;손경록;김하람;강유미;이승기;황순홍;배석진;김연희
    • 상하수도학회지
    • /
    • 제36권2호
    • /
    • pp.81-95
    • /
    • 2022
  • The present study was performed to investigate the effects of NH3-N and nitrifying microorganisms on the increased BOD of downstream of the Yeongsan river in Gwangju. Water samples were collected periodically from the 13 sampling sites of rivers from April to October 2021 to monitor water qualities. In addition, the trends of nitrogenous biochemical oxygen demand (NBOD) and microbial clusters were analyzed by adding different NH3-N concentrations to the water samples. The monitoring results showed that NH3-N concentration in the Yeongsan river was 22 times increased after the inflow of discharged water from the Gwangju 1st public sewage treatment plant (G-1-PSTP). Increased NH3-N elevated NBOD levels through the nitrification process in the river, consequently, it would attribute to the increase of BOD in the Yeongsan river. Meanwhile, there was no proportional relation between NBOD and NH3-N concentrations. However, there was a significant difference in NBOD occurrence by sampling sites. Specifically, when 5 mg/L NH3-N was added, NBOD of the river sample showed 2-4 times higher values after the inflow of discharged water from G-1-PSTP. Therefore, it could be thought other factors such as microorganisms influence the elevated NBOD levels. Through next-generation sequencing analysis, nitrifying microorganisms such as Nitrosomonas, Nitroga, and Nitrospira (Genus) were detected in rivers samples, especially, the proportion of them was the highest in river samples after the inflow of discharged water from G-1-PSTP. These results indicated the effects of nitrifying microorganisms and NH3-N concentrations as important limiting factors on the increased NBOD levels in the rivers. Taken together, comprehensive strategies are needed not only to reduce the NH3-N concentration of discharged water but also to control discharged nitrifying microorganisms to effectively reduce the NBOD levels in the downstream of the Yeongsan river where discharged water from G-1-PSTP flows.

Comparison of BOD, COD, TOC and DOC as the Indicator of Organic Matter Pollution of Agricultural Surface Water in Gyeongnam Province

  • Lee, Seong-Tae;Lee, Young-Han;Hong, Kwang-Pyo;Lee, Sang-Dae;Kim, Min-Kyeong;Park, Jong-Hwan;Seo, Dong-Cheol
    • 한국토양비료학회지
    • /
    • 제46권5호
    • /
    • pp.327-332
    • /
    • 2013
  • This survey was conducted to obtain basic data about organic matter such as BOD (Biochemical Oxygen Demand), COD (Chemical Oxygen Demand), DOC (Dissolved Organic Carbon) and TOC (Total Organic Carbon) in agricultural water in Gyeongnam province. BOD and COD are currently used for water quality indices, but adoption of TOC is being suggested. The surface water samples were collected at 39 locations in Gyeongnam province in April, July and October. Average concentrations of BOD, COD, DOC and TOC were 1.6, 3.3, 5.3 and $5.7mg\;L^{-1}$, respectively. In July, average concentrations of BOD and COD were 2.4 and $3.9mg\;L^{-1}$, respectively, showing these values were higher than other months. Average concentrations of TOC in April, July and October were 4.8, 7.4 and $4.8mg\;L^{-1}$, respectively. This suggested that the highest value of TOC was in July. Average decomposition efficiencies for BOD-C/TOC and COD-C/TOC were 11.4 and 23.9%, respectively. Correlation coefficient of TOC and DOC was higher by 0.995, whereas that of TOC and COD was lower by 0.763. Especially, TOC and DOC were highly related than others.

남한강 수계에서 장기 이화학적 수질특성에 대한 토지이용도 및 계절성 강우의 영향 (Influence of Landuse Pattern and Seasonal Precipitation on the Long-term Physico-chemical Water Quality in Namhan River Watershed)

  • 이지은;최지웅;안광국
    • 한국환경과학회지
    • /
    • 제21권9호
    • /
    • pp.1115-1129
    • /
    • 2012
  • The objective of this study was to analyze long-term annual and seasonal trends of water chemistry on landuse patterns and seasonal precipitation using 72 sampling sites within Namhan River watershed during 2001-2010. Water quality, based on multi-parameters of water temperature(WT), dissolved oxygen(DO), biochemical oxygen demand(BOD), chemical oxygen demand(COD), suspended solids(SS), total nitrogen(TN), total phosphorus(TP), and electric conductivity(EC) varied largely depending on monsoon rain and landuse patterns such as forest, cropland, and residence. Concentrations of BOD and COD as an indicator for organic matter pollution, increased during summer monsoon season at the cropland and residential streams. Values of TN and TP were higher in residential streams than in the forest and cropland streams. In the meantime, DO values had weak relations to the landuse patterns of forest and cropland cover. Water quality was worst in cropland and residential streams, and also most degradated in 4th order streams. Overall, our results suggest that efficient water quality management is required in the cropland and residential landuse streams.

송어양식장의 위해요소 관리를 위한 수질 모니터링 (Water Quality Monitoring for Hazard Analysis in Aquaculture Farm of Rainbow Trout)

  • 김영목;이명숙;정용현
    • 수산해양교육연구
    • /
    • 제25권4호
    • /
    • pp.819-827
    • /
    • 2013
  • Water quality has been considered to be one of sanitation standard operating procedures (SSOP) for hazard analysis critical control points (HACCP) application in aquaculture farms. This study was conducted to evaluate a hazard caused by water used in aquaculture farm of rainbow trout. The water quality was analyzed to investigate both physiochemical and bacteriological level in water samples collected from aquaculture farm of rainbow trout, Oncorhynchus mykiss. No significant difference were observed on water temperature and pH from season to season. However, the levels of dissolved oxygen were decreased as the outside temperature was increased, even if the levels were adequate for aquaculture. Also, other physiochemical analysis including biochemical oxygen demand (BOD), chemical oxygen demand (COD) and suspended solid (SS) revealed that the waters for aquaculture analyzed in this study was suitable for rainbow trout aquaculture. The bacterial analyses were also revealed that the waters for aquaculture were met to both coliform group (<18 MPN/100mL) and viable cell count (<100 CFU/mL). However, some of waste waters from aquaculture farms showed higher levels of BOD and COD than those of waste water standard (<2 ppm), suggesting that regular cleaning of fish tank and precipitation tank is needed.

펄프.제지산업(製紙産業) 폐수(廢水)의 특성(特性)과 생물학적(生物學的) 처리기술(處理技術) (Characteristics of Wastewater from the Pulp.Paper Industry and its Biological Treatment Technologies)

  • 안지환;임미희
    • 자원리싸이클링
    • /
    • 제18권2호
    • /
    • pp.16-29
    • /
    • 2009
  • 본고는 펄프 제지산업 폐수에 함유된 오염물질들의 특성과 생물학적 처리기술들에 대해 설명한다. 펄프 제지산업 폐수는 고농도의 생화학적 산소요구량 (BOD)과 화학적 산소요구량 (COD)을 포함하고 높은 독성을 보이며 강한 흑갈색을 띠는 것이 특징이다. 특히, 펄프의 표백공정에서 리그닌의 염소화에 의해 다이옥신, 퓨란과 같은 독성의 유기염소화합물이 형성된다는 것이 알려져있다. 이에 따라 최근 펄프 제지산업은 기존의 표백처리를 무염소공정(TCF)으로 대체하고 있다. 펄프 제지산업 폐수처리에 사용되는 모든 생물학적 기술들은 폐수와 박테리아의 접촉 메커니즘에 기반을 두고 있는데, 이것은 박테리아가 폐수 내 유기물질을 먹이로 이용하여 세포로 전환함으로써 폐수 내 BOD농도를 감소시키는 것이다. 펄프 제지산업 폐수의 생물학적 처리에서 호기성 처리와 혐기성 처리 모두 효과적인 것으로 밝혀졌다. 뿐만 아니라, 최근 곰팡이류를 이용한 생물학적 처리, 생물-응집-여과기법을 혼용한 처리 등도 폐수처리분야에 새롭게 적용되었다. 이러한 기술들로 처리된 폐수를 펄프 제지공정에 재활용함으로써 제조공정의 물소비량을 상당히 감소시킬 수 있다.