• Title/Summary/Keyword: Bioabsorbable screw

Search Result 20, Processing Time 0.039 seconds

Pretibial cyst after Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Autograft - A Case Report - (자가 슬괵근을 이용한 전방 십자 인대 재건술 후 발생한 전경골 낭종 - 증례 보고 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Ha, Dong-Jun;Jung, Hun-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.53-57
    • /
    • 2009
  • The pretibial cyst is a very rare complication after anterior cruciate ligament (ACL) reconstruction. It occurs whatever kind of graft choice or kind of graft fixation method at tibial side. It have been known such as graft necrosis at tibial side, extra-articular leakage of joint fluid through tibial tunnel, foreign body reaction due to breakdown of the bioabsorbable screw and incomplete incorporation of graft to bony tunnel as the cause of pretibial cyst. We experienced one case of pretibial cyst which had undergone ACL reconstruction with autogenous hamstring graft fixed with biodegradable interference screw. We report a rare case of pretibial cyst with literature review.

  • PDF

Cranioplasty and temporal hollowing correction with a three-dimensional printed bioresorbable mesh and double vertical suture anchor muscle sling: a case report

  • Choi, Jae Hyeok;Roh, Tai Suk;Lee, Won Jai;Baek, Wooyeol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.4
    • /
    • pp.178-182
    • /
    • 2022
  • Postoperative temporal hollowing is a common complication of craniotomy. Damage and repositioning of the temporalis muscle can lead to a depression in the temporal side of the skull with inferior bulging, worsening aesthetic outcomes. We report a case of cranioplasty with three-dimensional (3D) printed mesh involving an additional correction using a temporalis muscle sling to help address this problem. A 3D-printed bioabsorbable mesh was prepared based on preoperative facial computed tomography, and was fixed to the hollowed area for tissue augmentation. The temporalis muscle was elevated and fanned out to its original position, and a sling was attached to a screw that was fixed to the mesh. For reinforcement, an additional sling was attached to another screw fixed to the mesh 2-3 cm vertically above the first screw. Aesthetic results were confirmed immediately after surgery and later during outpatient follow-up. Both depression and lateral bulging were resolved, and there was no delayed drooping of the temporalis muscle on 6-month follow-up. There were no complications, and the patient was satisfied with the appearance. This is a simple yet effective technique with a low risk of complications, and should be considered for postoperative temporal hollowing patients, especially those with severe lateral bulging.

Study of Bio-absorbability and Bio-compatibility of Poly-L-lactic-acid Implant in Dogs (개에서 Poly-L-lactic-acid 이식물의 생분해성과 생체적합성에 관한 연구)

  • Park, Po-Young;Kim, Young-Ki;Bahk, Jong-Yoon;Park, Joung-Man;Koh, Phil-Ok;Chang, Hong-Hee;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.182-191
    • /
    • 2007
  • Bioabsorbable devices have been utilized and experimented in many aspects of orthopaedic surgery. Depending upon their constituent polymers, these materials can be tailored to provide sufficient rigidity to allow bone healing, retain mechanical strength for certain period of time, and then eventually begin to undergo degradation. The objective of this study was to estimate extent in which Poly-L-latic acid (PLLA) implants had bioabsorbability and biocompatibility with bone and soft tissue in dogs and also to develop bioabsorbable, biocompatible materials with the appropriate strength and degradation characteristics to allow for regular clinical use for treating orthopedic problems in humans as well as animals. Eighteen dogs were used as experimental animals and were inserted two types of PLLA implants. PLLA rods were inserted into subcutaneous tissue of back or the abdomen wall. And the rods were tested for material properties including viscosity, molecular weight, melting point, melting temperature, crystallinity, flexural strength, and flexural modulus over time. PLLA screws were inserted through cortical bone into bone marrow in the femur of the dogs and stainless steel screw was inserted in the same femur. Radiographs were taken after surgery to observe locations of screw. Histological variations including cortical bone response, muscular response, bone marrow response were analyzed over the time for 62weeks. The physical properties of PLLA rods had delicate balances between mechanical, thermal and viscoelastic factors. PLLA screws did not induce any harmful effects and clinical complications on bone and soft tissue for degradation period. These results suggest that PLLA implants could be suitable for clinical use.

Pretibial Ganglion Cyst after Arthroscopic Anterior Cruciate Ligament Reconstruction - A Case Report - (전방 십자 인대 재건술 후 발생한 전경골 결절종 - 1례 보고 -)

  • Jeon, Ho-Seung;Jeon, Seung-Ju;Kim, Jong-Min;Seo, Young-Ray
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.124-127
    • /
    • 2010
  • Pretibial ganglion cyst after arthroscopic anterior cruciate ligament reconstruction is a very rare complication, and a few are reported in and outside the country. Some authors report that it may break out with a variety of causes at any time. We experienced a case of pretibial ganglion cyst after arthroscopic anterior cruciate ligament reconstruction using Achilles tendon allograft and bioabsorbable interference screw in 34-year-old male. So we report this case including the cause and the treatment with a review of the literature.

  • PDF

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Rigid Fixation using Bioabsorbable Mesh and Screws in Facial Bone Fracture (흡수성 망상판과 나사를 이용한 안면골절의 견고정법)

  • Shin, Dong-Hyeok;Kim, Deok-Jung;Kim, Soo-Young;Hwang, Eun-A;Choi, Hyun-Gon;Kim, Soon-Heum;Uhm, Ki-Il
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.717-720
    • /
    • 2010
  • Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.

Comparative Biomechanical Study of Stiffness on Ligamentous Attached Sites of Distal Femur - Experimental Laboratory Study on Cadaver Femora - (원위 대퇴골 인대 부착부의 강도 비교 - 사체의 대퇴골에 행한 실험적 연구 -)

  • Kwak, Ji-Hoon;Sim, Jae-Ang;Yang, Sang-Hoon;Kim, Dong-Hee;Lee, Beom-Koo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.26-32
    • /
    • 2009
  • Purpose: This study was performed to compare the strength of ligamentous attached sites of cadaveric distal femur and to obtain reliable biomechanical data to use in ligamentous reconstruction or augmentation. Materials and Methods: Fifteen cadaveric distal femurs were used for this study. After measuring the bone density, 5.0 mm cannulated screw (Experiment 1) or reconstructed porcine ligament (Experiment 2) was inserted into the each ligamentous attached sites of anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL) and lateral collateral ligament (LCL). In experiment 2, reconstructed porcine graft was fixed with bioabsorbable screw in ligamentous insertion sites. And we measured the maximal pullout force of each ligamentous attached sites of cadaveric distal femur. Results: Average bone mineral density was $1.205{\pm}0.137\;g/cm^2$ in experiment 1, $1.236{\pm}0.089\;g/cm^2$ in experiment 2, which showed no statistically significant differences. In experiment 1, average pull-out strength of ACL, PCL, MCL and LCL group were $519.1{\pm}111.7$ N, $638.9{\pm}144.4$ N, $169.7{\pm}56.0$ N, $225.6{\pm}61.5$ N respectively. In experiment 2, the average pull-out strength were $310.6{\pm}31.0$ N, $379.9{\pm}47.4$ N, $104.0{\pm}14.4$ N, $131.5{\pm}21.9$ N respectively. In experiment 1, there was no significant difference between ACL and PCL group and between MCL and LCL group. However, the maximal pullout strength of MCL and LCL group were significantly lower than that of ACL and PCL group (p<0.01). Experiment 2 showed the same results of experiment 1. Conclusion: Because stiffness of MCL and LCL attached sites are much lower than that of ACL and PCL attached sites, we may consider augmented fixation in ligamentous reconstructions of MCL and LCL.

  • PDF

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF