• Title/Summary/Keyword: Bioabsorbable plate

Search Result 9, Processing Time 0.018 seconds

Bioabsorbable osteofixation for orthognathic surgery

  • Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.6.1-6.9
    • /
    • 2015
  • Orthognathic surgery requires stable fixation for uneventful healing of osteotomized bony segments and optimal remodeling. Titanium plates and screws have been accepted as the gold standard for rigid fixation in orthognathic surgery. Although titanium osteofixation is the most widely used approach, the use of bioabsorbable devices has been increasing recently. Biodegradation of bioabsorbable devices eliminates the need for a second operation to remove metal plates and screws. However, long-term stability and relapse frequency in bioabsorbable osteofixation are still insufficiently studied, especially in cases of segmental movements of great magnitude or segmental movements to a position where bony resistance exists. This paper reviews the background, techniques, and complications of bioabsorbable osteofixation and compares bioabsorbable and titanium osteofixation in orthognathic surgery in terms of skeletal stability.

Cephalometric evaluation of skeletal stability and pharyngeal airway changes after mandibular setback surgery: Bioabsorbable versus titanium plate and screw fixation

  • Phu Hnin Thet;Boosana Kaboosaya
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.181-190
    • /
    • 2024
  • Purpose: This study compared sequential changes in skeletal stability and the pharyngeal airway following mandibular setback surgery involving fixation with either a titanium or a bioabsorbable plate and screws. Materials and Methods: Twenty-eight patients with mandibular prognathism undergoing bilateral sagittal split osteotomy by titanium or bioabsorbable fixation were randomly selected in this study. Lateral cephalometric analysis was conducted preoperatively and at 1 week, 3-6 months, and 1 year postoperatively. Mandibular stability was assessed by examining horizontal (BX), vertical (BY), and angular measurements including the sella-nasion to point B angle and the mandibular plane angle (MPA). Pharyngeal airway changes were evaluated by analyzing the nasopharynx, uvula-pharynx, tongue-pharynx, and epiglottis-pharynx (EOP) distances. Mandibular and pharyngeal airway changes were examined sequentially. To evaluate postoperative changes within groups, the Wilcoxon signed-rank test was employed, while the Mann-Whitney U test was used for between-group comparisons. Immediate postoperative changes in the airway were correlated to surgical movements using the Spearman rank test. Results: Significant changes in the MPA were observed in both the titanium and bioabsorbable groups at 3-6 months post-surgery, with significance persisting in the bioabsorbable group at 1 year postoperatively (2.29°±2.28°; P<0.05). The bioabsorbable group also exhibited significant EOP changes (-1.21±1.54 mm; P<0.05) at 3-6 months, which gradually returned to non-significant levels by 1 year postoperatively. Conclusion: Osteofixation using bioabsorbable plates and screws is comparable to that achieved with titanium in long-term skeletal stability and maintaining pharyngeal airway dimensions. However, a tendency for relapse exists, especially regarding the MPA.

Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures (생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료)

  • Kwon, Duck-Joo;Lee, Yong-Beom;Shin, Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF

TREATMENT OF MANDIBLE FRACTURES USING BIOABSORBABLE PLATES: PRELIMINARY STUDY (생흡수성판을 이용한 하악골 골절의 치료 : 일차보고)

  • Kim, Young-Kyun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.6
    • /
    • pp.570-575
    • /
    • 2001
  • This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Thirty-four fractures of the mandible in 27 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pre-tapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 5.3 days. Patients were evaluated for complications during the follow-up period, which ranged from 2 to 18 months. Five patients(18.5%) experienced complications. These included infection (four patients), and premature occlusal contact(one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures with the advantage that they do not need to be removed.

  • PDF

Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

  • Doh, GyeongHyeon;Bahk, Sujin;Hong, Ki Yong;Lim, SooA;Han, Kang Min;Eo, SuRak
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.143-147
    • /
    • 2018
  • We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.

Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

  • Jeon, Hong Bae;Kang, Dong Hee;Gu, Ja Hea;Oh, Sang Ah
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.40-45
    • /
    • 2016
  • Background Bioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws. Methods A total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland) plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA) in 61 patients. Their mean age was 35.2 years (range, 15-84 years). Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla. Results Complications occurred in eight (3.4%) of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction. Conclusions Inadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.

Treatment of syndesmotic injury of ankle with bioabsorbable screw (생체흡수성 나사못을 이용한 원위경비관절 이개의 치료)

  • Kang, Jae-Do;Kim, Kwang-Ryul;Kim, Hyung-Chun;Lim, Moon-Sup;Kim, Jin-Hyung;Kim, Seong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.88-94
    • /
    • 2003
  • Purpose: Bioabsorbable screws are used to fix the syndesmotic injury of ankle because of no need for additional operation to remove it. The purpose of this study is to assess the efficacy of polylevolactic acid (PLLA) screws of in the treatment of the syndesmotic injury of ankle. Materials and Methods: Eight patients of the syndesmotic injury of ankle with malleolar fracture were evaluated in this study. They were managed with plate and screw fixation for malleolar fracture and polylevolactic acid screw fixation for syndesmotic injury, followed by plaster splinting for 6 weeks. Clinical and radiographic evaluation were done and functional scores were assessed. Results: In all cases, malleolar fractures were healed without problematic widening of syndesmosis. There were no sinus tract formation and no wound complication. Of eight patients, five had excellent results and three had good results. Conclusion: We conclude that polylevolactic acid screw is good material for fixation of the syndesmotic injury of ankle.

  • PDF

Bioabsorbable Screws Used in Hallux Valgus Treatment Using Proximal Chevron Osteotomy (무지외반증 환자의 근위 갈매기형 절골술에서 생체 흡수성 나사못을 이용한 고정)

  • Shin, Woo-Jin;Chung, Young-Woo;An, Ki-Yong;Seo, Jae-Woong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.4
    • /
    • pp.181-183
    • /
    • 2018
  • Hallux valgus is a deformity that causes pain in the first metatarsophalangeal joint. Surgical methods are quite diverse and a range of osteotomies are used at the proximal and distal part of the metatarsal bone and proximal phalange. Fixation methods, such as plate, screw, K-wire, and others have been used in various ways. The fixation device is often removed with various side effects due to the fixation devices. In the case of instruments that are absorbed in vivo, these procedures are not necessary to remove and there is an advantage of not performing the second operation. Three patients were treated, in which a proximal chevron osteotomy was used with a bioabsorbable screw (K-$MET^{TM}$; U&I Corporation).

Rigid Fixation using Bioabsorbable Mesh and Screws in Facial Bone Fracture (흡수성 망상판과 나사를 이용한 안면골절의 견고정법)

  • Shin, Dong-Hyeok;Kim, Deok-Jung;Kim, Soo-Young;Hwang, Eun-A;Choi, Hyun-Gon;Kim, Soon-Heum;Uhm, Ki-Il
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.717-720
    • /
    • 2010
  • Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.