• Title/Summary/Keyword: Bio-sensor System

Search Result 293, Processing Time 0.034 seconds

Implementation of a bio-inspired two-mode structural health monitoring system

  • Lin, Tzu-Kang;Yu, Li-Chen;Ku, Chang-Hung;Chang, Kuo-Chun;Kiremidjian, Anne
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.119-137
    • /
    • 2011
  • A bio-inspired two-mode structural health monitoring (SHM) system based on the Na$\ddot{i}$ve Bayes (NB) classification method is discussed in this paper. To implement the molecular biology based Deoxyribonucleic acid (DNA) array concept in structural health monitoring, which has been demonstrated to be superior in disease detection, two types of array expression data have been proposed for the development of the SHM algorithm. For the micro-vibration mode, a two-tier auto-regression with exogenous (AR-ARX) process is used to extract the expression array from the recorded structural time history while an ARX process is applied for the analysis of the earthquake mode. The health condition of the structure is then determined using the NB classification method. In addition, the union concept in probability is used to improve the accuracy of the system. To verify the performance and reliability of the SHM algorithm, a downscaled eight-storey steel building located at the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark structure. The structural response from different damage levels and locations was collected and incorporated in the database to aid the structural health monitoring process. Preliminary verification has demonstrated that the structure health condition can be precisely detected by the proposed algorithm. To implement the developed SHM system in a practical application, a SHM prototype consisting of the input sensing module, the transmission module, and the SHM platform was developed. The vibration data were first measured by the deployed sensor, and subsequently the SHM mode corresponding to the desired excitation is chosen automatically to quickly evaluate the health condition of the structure. Test results from the ambient vibration and shaking table test showed that the condition and location of the benchmark structure damage can be successfully detected by the proposed SHM prototype system, and the information is instantaneously transmitted to a remote server to facilitate real-time monitoring. Implementing the bio-inspired two-mode SHM practically has been successfully demonstrated.

Monitoring of Pig Body Temperature Using Infrared Sensors (적외선 센서를 이용한 돼지 체온 모니터링)

  • Jang, Jin Cheol;Lee, Jun Yeop;Lee, Sang Yoon;Kim, Hyuck Joo;Choi, Dong Yoon;Lee, Sunghyoun;Kim, Hyeon Tae
    • Journal of Animal Environmental Science
    • /
    • v.20 no.3
    • /
    • pp.91-96
    • /
    • 2014
  • The temperature of a pig is the most key point in determining, it's health status. We wanted to monitor the body temperature of pig to find out if any changes would occur, we used 3 minipigs (about 20 kg) who were feed using a feeding system while being confined in a pig house. The infrared testings were taken from a height of 30 cm above the pigs backs over a period of 28 days. We were able to conclude that the results between the back and indoor temperature were y = 0.5487x + 18.459. These values were compared with the values found after infrared sensor results were taken. We found an error range of $0.004{\sim}1.82^{\circ}C$ and an average of $0.58^{\circ}C$. In conclusion, using an infrared thermometer made monitoring of pigs back possible. This system seems to be feasible and effective in monitoring pig temperature.

Analysis of reactive species in water activated by plasma and application to seed germination

  • Choi, Ki-Hong;Lee, Han-Ju;Park, Gyungsoon;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.162.1-162.1
    • /
    • 2015
  • The use of plasma has increased in bio-application field in recent years. Particularly, water treated by arc discharge or atmospheric pressure plasma has been actively utilized in bio-industry. In this study, we have developed a plasma activated water generating system. For this system, two kinds of plasma sources; dielectric barrier discharge (DBD) plasma and arc discharge plasma have been used. The discharge energy was calculated using the breakdown voltage and current, and the emission spectrum was measured to investigate the generated reactive species. We also analyzed the amount of reactive oxygen and nitrogen species in water using the chemical methods and nitric oxide sensor. Finally, the influence of plasma generated reactive species on the germination and growth of spinach (Spinacia oleracea) was investigated. Spinach is a green leafy vegetable that contains a large amount of various physiologically active organic compounds. However, it is characterized with a low seed germination rate.

  • PDF

Development of micro-mold for New Injecton Molder to fabricate Micro-Nano system (Micro-Nano 시스템 제조를 위한 소형 차세대 사출기 개발과 이를 위한 Micro meld의 개발)

  • 황교일;류경주;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.910-913
    • /
    • 2002
  • Recently, the sensor and actuator are developed with EAP(Electro Active Polymer). Common used of they is close at hand, the bio chip and Lab on a chip are researched. For developed bio and micro system, a researcher applies semiconductor fabrication or make it by his hand. But, this method takes long time and a tolerance is large So they are problem of common used. So In this paper we propose the new inject ion molder and micro mold. The micro mold is different from exist ing mold. In this paper, the fabration of micro mold is introduced to inject.

  • PDF

Design and Implementation of a Real-time Bio-signal Obtaining, Transmitting, Compressing and Storing System for Telemedicine (원격 진료를 위한 실시간 생체 신호 취득, 전송 및 압축, 저장 시스템의 설계 및 구현)

  • Jung, In-Kyo;Kim, Young-Joon;Park, In-Su;Lee, In-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.42-50
    • /
    • 2008
  • The real-time bio-signal monitoring system based on the ZigBee and SIP/RTP has proposed and implemented for telemedicine but that has some problems at the stabilities to transmit bio-signal from the sensors to the other sides. In this paper, we designed and implemented a real-time bio-signal monitoring system that is focused on the reliability and efficiency for transmitting bio-signal at real-time. We designed the system to have enhanced architecture and performance in the ubiquitous sensor network, SIP/RTP real-time transmission and management of the database. The Bluetooth network is combined with ZigBee network to distribute traffic of the ECG and the other bio-signal. The modified and multiplied RTP session is used to ensure real-time transmission of ECG, other bio-signals and speech information on the internet. The modified ECG compression method based on DWLT and MSVQ is used to reduce data rate for storing ECG to the database. Finally we implemented a system that has improved performance for transmitting bio-signal from the sensors to the monitoring console and database. This implemented system makes possible to make various applications to serve U-health care services.

Development of Portable u-Health Monitoring System (휴대형 u-Health 모니터링 시스템 개발)

  • Han, Jung-Soo;Kim, Gui-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.46-53
    • /
    • 2009
  • This study aims to develop a mobile-based portable u-Health Monitoring System which provides a personal medical service on demand by processing patients' data intellectually achieved through sensing technique of non-restriction/non-consciousness oriented and deciding. To do this, we composed a USN-based portable monitoring unit. It is the one, that contains a somatometry sensor which is attached to patient's body and detects bio information, a portable wireless terminal which receives information from the sensor and transmits it to monitor server, and a monitor server which interprets received data through wireless network and processes. Also, it tries to develop a non-restriction /non-consciousness oriented sensing technique which is related to glycosuria and cardiovascular diseases.

An Energy-Efficient Protocol For Detecting Injurious Insect in Wireless Bio Sensor Networks (무선 바이오센서 네트워크에서 에너지 효율을 고려한 해충 감지 시스템을 구축하기 위한 프로토콜)

  • Yoo, Dae Hyun;Lee, Joo Sang;An, Beongku;Kim, Nam-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.2
    • /
    • pp.29-34
    • /
    • 2008
  • In this paper, we proposed a system protocol for detecting injurious insect to support energy saving transmission in wireless bio sensor networks. The main ideas and features of the system are as follows. First, the route establishment method which is based on the energy efficiency and stability by using time-division tree structure. Second, multi-hop direction-based data gatering structure. In this structure, the selected fading method is used to transmit packet via the established tree structure for supporting power saving and route lifetime efficiently. Finally, we can get the node power saving and reduce transmission delay, thus network lifetime and efficiency are improved. The performance evaluation of the proposed protocol is via OPNET(Optimized Network Engineering Tool).

  • PDF

First-order Wire-wound SQUID Gradiometer System Having Compact Superconductive Connection Structure between SQUID and Pickup Coil (SQUID와 검출코일의 초전도 결합방식이 개선된 1차 권선형 미분계 시스템)

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Kwon, H.;Kim, K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 2007
  • In order to have a superconductive connection between the wire-wound pickup coil and input coil, typically Nb terminal blocks with screw holes are used. Since this connection structure occupies large volume, large stray pickup area can be generated which can pickup external noise fields. Thus, SQUID and connection block are shielded inside a superconducting tube, and this SQUID module is located at some distance from the distal coil of the gradiometer to minimize the distortion or imbalance of uniform background field due to the superconducting module. To operate this conventional SQUID module, we need a higher liquid He level, resulting in shorter refill interval. To make the fabrication of gradiometers simpler and refill interval longer, we developed a novel method of connecting the pickup coil into the input coil. Gradiometer coil wound of 0.125-mm diameter NbTi wires were glued close to the input coil pads of SQUID. The superconductive connection was made using an ultrasonic bonding of annealed 0.025-mm diameter Nb wires, bonded directly on the surface of NbTi wires where insulation layer was stripped out. The reliability of the superconductive bonding was good enough to sustain several thermal cycling. The stray pickup area due to this connection structure is about $0.1\;mm^2$, much smaller than the typical stray pickup area using the conventional screw block method. By using this compact connection structure, the position of the SQUID sensor is only about 20-30 mm from the distal coil of the gradiometer. Based on this compact module, we fabricated a magnetocardiography system having 61 first-order axial gradiometers, and measured MCG signals. The gradiometers have a coil diameter of 20 mm, and the baseline is 70 mm. The 61 axial gradiometer bobbins were distributed in a hexagonal lattice structure with a sensor interval of 26 mm, measuring $dB_z/dz$ component of magnetocardiography signals.

  • PDF

Interface Development for the Point-of-care device based on SOPC

  • Son, Hong-Bum;Song, Sung-Gun;Jung, Jae-Wook;Lee, Chang-Su;Park, Seong-Mo
    • Journal of Information Processing Systems
    • /
    • v.3 no.1
    • /
    • pp.16-20
    • /
    • 2007
  • This paper describes the development of the sensor interface and driver program for a point of care (POC) device. The proposed pac device comprises an ARM9 embedded processor and eight-channel sensor input to measure various bio-signals. It features a user-friendly interface using a full-color TFT-LCD and touch-screen, and a bluetooth wireless communication module. The proposed device is based on the system on a programmable chip (SOPC). We use Altera's Excalibur device, which has an ARM9 and FPGA area on a chip, as a test bed for the development of interface hardware and driver software.

Bio-functionalization of the Single Layer Graphene for Detecting the Cancer Cell

  • Oh, Hyung Sik;Park, Wanjun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.429.1-429.1
    • /
    • 2014
  • We present a method of surface functionalization of a single layer graphene for linking and detecting MDA-MB-231 human breast cancer cell. The methodology is done by utilizing 1-pyrenebutanoic acid and succinimidyl ester for immobiling CD44 antibodies. This work shows that the single layer graphene is an efficient fixing substance to capture the MDA-MB-231 human breast cancer cell, selectively. The immobilization method of the cancer cell on the graphene layer will be an effective cell counting system. Moreover usage of the linking with non-covalent bonding is expected to develope a sensor scheme of electrical cell-detecting diagnosis system.

  • PDF