• Title/Summary/Keyword: Bio-impedance

Search Result 108, Processing Time 0.019 seconds

Optimum electrode selection for measuring the abdominal pressure using bio-impedance method (비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정)

  • An, Yang-Su;Kim, Keo-Sik;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

The Novel Method of Segmental Bio-Impedance Measurement Based on Multi-Frequency for a Prediction of risk Factors Life-Style Disease of Obesity (비만관련 생활습관병 위험인자 예측을 위한 다중 주파수 기반의 분할 체임피던스 측정법)

  • Kim, Eung-Seok;Noh, Yeon-Sik;Seo, Kwang-Seok;Park, Sung-Bin;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.375-384
    • /
    • 2010
  • The purpose of this study is to determine whether there is a correlation between the segmental bio-impedance measurement with the frequency modulations and the life-style disease of obesity. An obesity is not simply the factor for estimating the life-style disease of obesity, but also the risk factor occurring. There are many methods (BMI, WHR, Waist, CT, DEXA, BIA, etc.) for measuring a degree of obesity; the bio-impedance measurement is more economic and more effective than others. The physical examination, the blood test, the medical imaging diagnosis and the bio-impedancemeasurementswithmultiple frequencies for each body parts have been conducted for 77 people. The estimated value has been calculated through a segmental bio-impedance model based on multi-frequency that was created to reflect the highest correlation by analyzing correlation with linear regression analysis method for the measured bio-impedance and the risk factors. Then we compared with the clinical diagnosis. In case of high level cholesterol, low HDL-C and high LDL-C for life-style disease, the sensitivity is 80~100%and the specificity is 83~100%. This study has shown conclusively that bio-impedance can be a possible predictor to analyze the disease risk rate of population and individual health maintenance. And also the multi-frequency segmental bio-impedance can be used as early predictor to estimate the life-style disease of obesity.

Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method (생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정)

  • Kim, Keo-Sik;Lee, Sang-Ok;Seo, Jeong-Hwan;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

A New Approach Method of Measuring Abdominal Pressure for Urodynamic Monitoring System (요역동학 측정시스템을 위한 새로운 복압측정 기법)

  • Seo, Jeong-Hwan;Kim, Keo-Sik;An, Yang-Su;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1170-1176
    • /
    • 2007
  • The conventional urodynamic monitoring is fulfilled by artificially filling a bladder with saline. Generally. it is difficult to evaluate the physiological functions of the storage and voiding of a bladder. With this aim, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by measuring bio-impedance variations. Our system was clinically evaluated for 10 patients. It turned out to be that as the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased more as compared to those who observed during the rest mode. Also, we determined the optimum electrode pair for estimating the abdominal pressure using bio-impedance method and consequently compared with the conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified in terms of impedance change, correlation coefficient and SNR Our results showed the optimum electrode pair (1,9) which could detect impedance changes due to the increase of the intensity in the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. Thus, our system demonstrated that the abdominal pressure could be measured noninvasively and conveniently by simply estimating bio-impedance values. We propose that this optimum electrode configuration would be useful for the future studies involving the handy measurements of abdominal pressure with our suggested ambulatory urodynamics monitoring system.

Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results (Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰)

  • Kim, Soo-Byeong;Lee, Na-Ra;Lee, Seung-Wook;Choi, Jun-Young;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

Development and Assessment of Conductive Fabric Sensor for Evaluating Knee Movement using Bio-impedance Measurement Method (슬관절 운동 평가를 위한 생체 임피던스 측정용 전도성 섬유센서 개발 및 평가)

  • Lee, Byung-Woo;Lee, Chung-Keun;Cho, Ha-Kyung;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.37-44
    • /
    • 2011
  • This paper describes the development and assessment of conductive fabric sensor for evaluating knee movement using bio-impedance measurement method. The proposed strip-typed conductive fabric sensor is compared with a dot-typed Ag/AgCl electrode for evaluating validity under knee movement condition. Subjects are composed of ten males($26.6{\pm}2.591$) who have not had problems on their knee. The strip-typed conductive fabric sensor is analyzed by correlation and reliability between a dot-typed Ag/AgCl electrode and the strip-typed conductive fabric sensor. The difference of bio-impedance between a dot-typed Ag/AgCl electrode and the strip-typed conductive fabric sensor averages $7.067{\pm}13.987\;{\Omega}$ As the p-value is under 0.0001 in 99% of t-distribution, the strip-typed conductive fabric sensor is correlated with a dot-typed Ag/AgCl electrode by SPSS software. The strip-typed conductive fabric sensor has reliability when it is compared with a dot-typed Ag/AgCl electrode because most of bio-impedance values are in ${\pm}1.96$ standard deviation by Bland-Altman Analysis. As a result, the strip-typed conductive fabric sensor can be used for assessing knee movement through bio-impedance measurement method as a dot-typed Ag/AgCl electrode. Futhermore, the strip-typed conductive fabric sensor is available for wearable circumstances, applications and industries in the near future.

Excitation Frequency Characteristics of a Conductive Fabric Sensor Using the Bio-impedance for Estimating Knee Joint Movements (슬관절 운동 평가를 위한 생체 임피던스 측정용 전도성 섬유 센서의 여기 주파수별 특성 평가)

  • Lee, Byung-Woo;Lee, Chung-Keun;Kim, Jin-Kwon;Jeong, Wan-Jin;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1427-1433
    • /
    • 2011
  • This study describes a conductive fabric sensor and determines an optimum excitation frequency of the sensor to evaluate knee joint movements. Subjects were composed of 15 males (age: $30.7{\pm}5.3$) with no known problems with their knee joints. The upper side of subjects' lower limbs was divided into two areas and the lower side of subjects' lower limbs was divided into three areas. The sensors were attached to 1 for 3 spot from a hip joint and to 3 for 4 spot from a knee joint which are the optimum conductive fabric sensor configuration to evaluate knee joint movements. As a result, the optimum excitation frequency for evaluating knee joint movements using conductive fabric sensors was 25 kHz. Average and standard deviation of bio-impedance changes from 15 subjects were $92.1{\pm}137.2{\Omega}$ at 25 kHz. The difference of bio-impedance changes between 25 kHz and 50 kHz was statistically significant (p<0.05) and the difference of bio-impedance changes between 25 kHz and 100 kHz was also statistically significant (p<0.001). These results showed that conductive fabric sensors are more sensitive to measure bio-impedance for evaluating knee joint movements as an excitation frequency decreases.

Factors influencing the bio-impedance data in tissue segments along the three arm meridians: a pilot study

  • Lim, Chi Eung Danforn;Wong, Felix Wu Shun;Smith, Warren
    • CELLMED
    • /
    • v.1 no.1
    • /
    • pp.7.1-7.9
    • /
    • 2011
  • Bioelectric impedance measurements have been reported to show significant variation between individuals. Different physiological conditions like thickened skin, obesity, and fluid retention can affect the impedance measurement. Therefore, it is important to learn what other factors can affect the measurements of impedance even in healthy individuals. Such information is a prerequisite for understanding the changes in impedance associated with acupuncture treatment. This study investigated the bio-impedance properties of tissue segments in the arms of a number of healthy subjects, so as to define the factors that might influence the variation of the bio-impedance data in acupuncture meridians studies. 51 healthy subjects were recruited through Liverpool Hospital, Sydney. Demographic data was collected from each subject including the age, sex, BMI, and time since most recent meal. Electrodes were applied to the forearms of each test subject. Measurements were done by a purpose-built Bio-Impedance Research Device (BIRD-I) which allowed the determination of core resistance (Rc) and core reactance (Xc) of each of the three meridian tissue segments on the anterior surface of the forearm. No significant difference was found in the core resistance attributable to age group, gender, BMI or meal intake. However, a statistically significant trend in increasing resistance from the radial to ulnar aspect of the forearm (p < 0.001) was found. No significant difference was found in the core resistance of test tissue segments among the 51 healthy subjects measured in this study. However, the trend of increasing core resistance from the radial to ulnar aspects of the arm deserves further investigation.

A monitoring apparatus for pulse shape of human heartbeats by magnetic impedance sensors (자기 임피던스 센서를 이용한 맥박 측정 장치)

  • Kim, Cheong-Worl;Gu, Bon-Ju;Kim, Jong-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • A monitoring apparatus for pulse shapes of human heartbeats has been developed using an amorphous MI(Magnetic Impedance) sensor. The pulse shapes are successfully obtained from voltage signals due to the variations of magnetic impedance in the amorphous MI sensor, which is attached to a patient's wrist. This voltage signal was fed into a signal processing module to extract the pulse shapes of heartbeats. The signal processing module, which is proposed to detect a weak variations of impedance in MI sensor under a noisy measurement environment, consists of a high frequency current source, an amplifier stage and a synchronous detection circuit. To evaluate the characteristics of a newly developed apparatus, various experiments were performed. The experimental results show that the developed apparatus could be used as a diagnosis tool for traditional Korean medicine with further systematic clinical studies.

A Study on the Measurement of Impedance in Animal Tissue Using Gold Electrodes (금 전극을 이용한 동물 조직 내 임피던스 측정연구)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.445-450
    • /
    • 2021
  • Bio-impedance measurement is a measurement device that can be used to obtain biometric information and diagnose skin diseases using convenience, low cost, and low cost devices. In this study, the bio-impedance was measured using a direct dry gold electrode and a simulation study through animal bio modeling to obtain biometric information in a biometric form. Impedance was measured by inserting electrodes into subcutaneous areas of animal tissue and applying frequencies of 100 uA, 1-100 kHz using a two-electrode method. As a result of the measurement, the resistance of the electrodes is measured high at 5 mm electrodes compared to 7.5 mm and 10 mm electrodes based on 5 mm electrodes. Based on the 5 mm electrode, an average difference of 1.49% was found for the 7.5 mm electrode in the total frequency range, and the impedance difference was confirmed to be 2.624% for the 10 mm electrode. In the future, the research results are expected to be valuable in designing and manufacturing electrodes for bio-inserted electrocardiogram sensors.