• Title/Summary/Keyword: Bio-analysis

Search Result 3,811, Processing Time 0.033 seconds

Radiotherapy Incidents Analysis Based on ROSIS: Tendency and Frequency (ROSIS 자료 기반 방사선 사고 사례 분석 : 경향과 빈도)

  • Koo, Jihye;Yoon, MyongGeun;Chung, Won Kuu;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.298-303
    • /
    • 2014
  • In this study, we examine the trends and types of incidents frequently occur during radiation therapy by using the data from the radiation oncology safety information system (ROSIS), according to discovery method explores the development direction of future research accident cause factor control method. This study was carried out analysis of incident data in ROSIS nearly 1163 cases in last 11 years from 2003 to 2013. We categorized into treatment methods, found the time, discoverer of occupations and finding ways to analyze the data. Then, we calculate the percentage and the classification for each item. About 1163 cases of incident cases including the near miss cases, external radiation therapy, brachytherapy and other were 97%, 2% and 1%. In the case was improperly planned dose delivery was 44% (497 cases) which 429 cases (86%) was found before 3 fractions and 13 cases were found after 11 fractions. The investigation was found to be distributed in various a found times. Approximately 42% of found time was during treatment and 29% of patients were found the problem during inspection chart. Occupation to discover the most radiation accidents was the radiation therapist (53%) who works in treatment room. Among 1163 incidence cases, 24% cases were found the accident before the treatment, therefore most of accident were found after of during the treatment (70%, 813 cases). This trend is acquired through ROSIS analysis, is expected to be not significantly different in the case of Korea, so it is necessary more diverse and systematic research for the prevention and early detection by using the ROSIS data.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Stress distribution of molars restored with minimal invasive and conventional technique: a 3-D finite element analysis (최소 침습적 충진 및 통상적 인레이 법으로 수복한 대구치의 응력 분포: 3-D 유한 요소 해석)

  • Yang, Sunmi;Kim, Seon-mi;Choi, Namki;Kim, Jae-hwan;Yang, Sung-Pyo;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.297-305
    • /
    • 2018
  • Purpose: This study aimed to analyze stress distribution and maximum von Mises stress generated in intracoronal restorations and in tooth structures of mandibular molars with various types of cavity designs and materials. Materials and Methods: Three-dimensional solid models of mandible molar such as O inlay cavity with composite and gold (OR-C, OG-C), MO inlay cavity with composite and gold (MR-C, MG-C), and minimal invasive cavity on occlusal and proximal surfaces (OR-M, MR-M) were designed. To simulate masticatory force, static axial load with total force of 200 N was applied on the tooth at 10 occlusal contact points. A finite element analysis was performed to predict stress distribution generated by occlusal loading. Results: Restorations with minimal cavity design generated significantly lower values of von Mises stress (OR-M model: 26.8 MPa; MR-M model: 72.7 MPa) compared to those with conventional cavity design (341.9 MPa to 397.2 MPa). In tooth structure, magnitudes of maximum von Mises stresses were similar among models with conventional design (372.8 - 412.9 MPa) and models with minimal cavity design (361.1 - 384.4 MPa). Conclusion: Minimal invasive models generated smaller maximum von Mises stresses within restorations. Within the enamel, similar maximum von Mises stresses were observed for models with minimal cavity design and those with conventional design.

Production of Medium-chain-length Poly (3-hydroxyalkanoates) by Pseudomonas sp. EML8 from Waste Frying Oil (Pseudomonas sp. EML8 균주를 이용한 폐식용류로부터 medium-chain-length poly(3-hydroxyalkanoates) 생합성)

  • Kim, Tae-Gyeong;Kim, Jong-Sik;Chung, Chung-Wook
    • Journal of Life Science
    • /
    • v.31 no.1
    • /
    • pp.90-99
    • /
    • 2021
  • In this study, to reduce the production cost of poly(3-hydroxyalkanoates) (PHA), optimal cell growth and PHA biosynthesis conditions of the isolated strain Pseudomonas sp. EML8 were established using waste frying oil (WFO) as the cheap carbon source. Gas chromatography (GC) and GC mass spectrometry analysis of the medium-chain-length PHA (mcl-PHAWFO) obtained by Pseudomonas sp. EML8 of WFO indicated that it was composed of 7.28 mol% 3-hydrxoyhexanoate, 39.04 mol% 3-hydroxyoctanoate, 37.11 mol% 3-hydroxydecanoate, and 16.58 mol% 3-hydroxvdodecanoate monomers. When Pseudomonas sp. EML8 were culture in flask, the maximum dry cell weight (DCW) and the mcl-PHAWFO yield (g/l) were showed under WFO (20 g/l), (NH4)2SO4 (0.5 g/l), pH 7, and 25℃ culture conditions. Based on this, the highest DCW, mcl-PHAWFO content, and mcl-PHAWFO yield from 3-l-jar fermentation was obtained after 48 hr. Similar results were obtained using 20 g/l of fresh frying oil (FFO) as a control carbon source. In this case, the DCW, the mcl-PHAFFO content, and the mcl-PHAFFO yields were 2.7 g/l, 62 wt%, and 1.6 g/l, respectively. Gel permeation chromatography analysis confirmed the average molecular weight of the mcl-PHAWFO and mcl-PHAFFO to be between 165-175 kDa. Thermogravimetric analysis showed decomposition temperature values of 260℃ and 274.7℃ for mcl-PHAWFO and mcl-PHAFFO, respectively. In conclusion, Pseudomonas sp. EML8 and WFO could be suggested as a new candidate and substrate for the industrial production of PHA.

Estimation of ecological flow and fish habitats for Andong Dam downstream reach using 1-D and 2-D physical habitat models (1차원 및 2차원 물리서식처 모형을 활용한 안동댐 하류 하천의 환경생태유량 및 어류서식처 추정)

  • Kim, Yongwon;Lee, Jiwan;Woo, Soyoung;Kim, Soohong;Lee, Jongjin;Kim, Seongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.12
    • /
    • pp.1041-1052
    • /
    • 2022
  • This study is to estimate the optimal ecological flow and analysis the spatial distribution of fish habitat for Andong dam downstream reach (4,565.7 km2) using PHABSIM (Physical Habiat Simulation System) and River2D. To establish habitat models, the cross-section informations and hydraulic input data were collected uisng the Nakdong river basic plan report. The establishment range of PHABSIM was set up about 410.0 m from Gudam streamflow gauging station (GD) and about 6.0 km including GD for River2D. To select representative fish species and construct HSI (Habitat Suitability Index), the fish survey was performed at Pungji bridge where showed well the physical characteristics of target stream located downstream of GD. As a result of the fish survey, Zacco platypus was showed highly relative abundance resulting in selecting as the representative fish species, and HSI was constructed using physical habitat characteristics of the Zacco platypus. The optimal range of HSI was 0.3~0.5 m/s at the velocity suitability index, 0.4~0.6 m at the depth suitability index, and the substrate was sand to fine gravel. As a result of estimating the optimal ecological flow by applying HSI to PHABSIM, the optimal ecological flow for target stream was 20.0 m3/sec. As a result of analysis two-dimensional spatial analysis of fish habitat using River2D, WUA (Weighted Usable Area) was estimated 107,392.0 m2/1000 m under the ecological flow condition and it showed the fish habitat was secured throughout the target stream compared with Q355 condition.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

Immunostimulntory Effects of Immu-Forte at 3 Months Post-Treatment in Mice (면역기능증강성 동암 바이오스 신물질에 대한 3개월간의 마우스 투여후의 면역학적 및 혈액학적 변화)

  • Jung Ji-Youn;Ahn Nam-Shik;Park Joon-Suk;Jo Eun-Hye;Hwang Jae-Woong;Lee Seoung-Hun;Park Jung-Ran;Kim Sun-Jung;Lee Yong-Geon;Jeong Yun-Hyeok;Chung Ji-Hye;Lee Soo-Jin;Lee Sang-Bum
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.2
    • /
    • pp.118-122
    • /
    • 2005
  • Immu-Forte (Dong-Ahm Bio's. Corp., Korea) was evaluated fir its effectiveness as a nonspecific immunostimulator in mice. The effects of Immu-Forte were determined by analysis of cytokines using ELISh and phenotype of leukocyte subpopulations using monoclonal antibodies specific to mouse leukocyte differentiation antigens and flow cytometry. CD4 T cells, CD8 T cells, macrophages, IL-12 and IFN-r in Immu-Forte EX-treated middle dose group increased in 3 months posttreatment and were significantly higher (p<0.05) than that of control at 3 months posttreatment. All T cells, all B cells, macrophages, IL-2, IL-4 and IL-12 in Immu-Forte EX-treated low dose uoup increased in 3 months posttreatment and were significantly higher (p<0.05) than that of control at 3 months posttreatment. In the Immu-Forte soy-treated group, CD4 T cells, IL-2, IL-4 and IL-12 were significantly higher in high dose-treated group, and CD 4 T cell, macrophages, IL-2, IL-4 and IL-12 were significantly higher in middle dose-treated group, and all T cell, IL-2, IL-4 and IL-12 were significantly higher in low dose-treated group. In the Itnmu-Forte A-treated group, macrophages, m cells and IL-12 in high dose-treated group and all T cells, macrophages, NK cells, IL-2, IL-4 and IL-12 in middle dose-treated group and NK cells in low dose-treated group were significantly higher (p<0.05) than that of control at 3 months posttreatment. In the Immu-Forte F-treated Group, all B cells, IL-4 and IL-12 in high dose-treated group and all T cells, aBl B cells, CD 4 T cells, CD8 T cells, macrophage, IL-2, IL-4, IL-12 and IFN-r in middle dose-treated group and NK cells and IL-12 in low dose-treated group were significantly higher (p<0.05) than that of control at 3 months posttreatment. In conclusion, the study has demonstrated that Immu-Forte had an immunostimulatory effect on mice through proliferation and activation of mouse immune cells.

Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse (소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석)

  • Lim, Mi Young;Ko, Chung Ho;Lee, Sang Bok;Kim, Hyo Kyeong;Bae, Yong Han;Kim, Young Bok;Yoon, Yong Cheol;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.3
    • /
    • pp.186-192
    • /
    • 2010
  • An infrared heating system, installed in a small venlo-type glasshouse ($280m^2$) in Gyeongsang National University, Jinju, Korea, was used to investigate its heating effect with potted Phalaenopsis, Schefflera arboricola 'Hongkong', Ficus elastica 'Variegata', and Rosa hybrida 'Yellow King' as the test plants. Temperature changes in test plants with the system turned 'On' and 'Off' were measured by using an infrared camera and the consumption of electricity by this infrared heating system was measured and analyzed. In potted Phalaenopsis, when the set air temperature of the greenhouse was $18^{\circ}C$, temperature of leaves and the growing medium were $22.8{\sim}27^{\circ}C$ and $21.3{\sim}24.3^{\circ}C$, respectively. In such tall plants as Schefflera arboricola 'Hongkong' and Ficus elastica 'Variegata', the upper part showed the highest temperature of 24.0 and $26.9^{\circ}C$, respectively. From the results of temperature change measurements, the plant temperatures were near or above the set point temperatures with some fluctuations depending on the position or distance from the infrared heating system. When air temperature between night and dawn dropped sharply, plant temperatures were maintained close to the set temperature ($18^{\circ}C$). There was a significant difference between 'On' and 'Off' states of the infrared heating system in average temperatures of root zone and leaf: 21.8 and $17.8^{\circ}C$ with the system 'On' and 20.4 and $15.5^{\circ}C$ with the system 'Off', respectively, in a cut rose Rosa hybrida 'Yellow King'. The heating load was about $24,850{\sim}35,830kcal{\cdot}h^{-1}$, which comes to about 27,000~40,000 won in Korean currency when calculated in terms of the cost of heating by a hot water heating system heated by petroleum. The cost for heating by the infrared heating system was about 35% of that of a hot water heating system. With the infrared heating system, the air temperature during the night was maintained slightly lower than the set point air temperature, probably due to the lack of air tightness of the glasshouse. Therefore, glasshouses with an infrared heating system requires further investigation including the installation space of the heat-emitting units, temperature sensor positions, and convection.

Anti-inflammatory Activity of Antimicrobial Peptide Zophobacin 1 Derived from the Zophobas atratus (아메리카왕거저리 유래 항균 펩타이드 조포바신 1의 항염증활성)

  • Shin, Yong Pyo;Lee, Joon Ha;Kim, In-Woo;Seo, Minchul;Kim, Mi-Ae;Lee, Hwa Jeong;Baek, Minhee;Kim, Seong Hyun;Hwang, Jae Sam
    • Journal of Life Science
    • /
    • v.30 no.9
    • /
    • pp.804-812
    • /
    • 2020
  • The giant mealworm beetle, Zophobas atratus (Coleoptera: Tenebrionidae) has been used as a protein source for small pets and mammals. Recently, it was temporarily registered in the list of the Food Code. We previously performed an in silico analysis of the Zophobas atratus transcriptome to identify putative antimicrobial peptides and identified several antimicrobial peptide candidates. Among them, we assessed the antimicrobial and anti-inflammatory activities of zophobacin 1 that was selected bio-informatically based on its physicochemical properties against microorganisms and mouse macrophage Raw264.7 cells. Zophobacin 1 showed antimicrobial activities against microorganisms without inducing hemolysis and decreased the nitric oxide production of the lipopolysaccharide-induced Raw264.7 cells. Moreover, ELISA and Western blot analysis revealed that zophobacin 1 reduced expression levels of pro-inflammatory enzymes such as inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2). We also investigated expression of pro-inflammatory cytokines (interleukin-6 and interleukin-1β) production through quantitative real time-PCR and ELISA. Zophobacin 1 markedly reduced the expression level of cytokines through the regulation of mitogen-activated protein kinases (MAPKs) and nuclear factor kappa B (NF-κB) signaling. We confirmed that zophobacin 1 bound to bacterial cell membranes via a specific interaction with lipopolysaccharides. These data suggest that zophobacin 1 could be promising molecules for development as antimicrobial and anti-inflammatory therapeutic agents.

Community Characteristics and Biological Quality Assessment on Benthic Macroinvertebrates of Bongseonsa Stream in Gwangneung Forest, South Korea (광릉숲 내 봉선사천의 저서성 대형무척추동물의 군집 특성 및 생물학적 하천평가)

  • Jung, Sang-Woo;Cho, Yong-Chan;Lee, Hwang-Goo
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.6
    • /
    • pp.508-519
    • /
    • 2017
  • There have been many studies on monitoring of biodiversity changes and preservation of Gwangneung Forest Biosphere Reserve (GFBR) in South Korea in recognition of the rare ecosystem that has been preserved for a long period. However, there are few studies on diversity and community characteristics of benthic macroinvertebrates as an indicator of stream health of GFBR. The purpose of this study was to assess the water quality of Bongseonsa Stream that penetrated through Gwangneung Forest and the nearby torrents by analyzing the benthic macroinvertebrates community during April to September 2016. The investigation collected a total of 114 species of benthic macroinvertebrates belonging to 56 families, 17 orders, 8 classes, and 5 phyla from the Bongseonsa Stream and Kwangneung Stream. Ephemeroptera and Trichoptera were the largest groups in species diversity with 30 species (32.3%) and 16 species (17.2%), respectively, and Tubificidae sp., Baetis fuscatus, Antocha KUa, and Cheumatopsyche brevilineata, which usually habit in contaminated streams, appeared frequently. Among the feeding function groups, the gatherers and hunters appeared relatively frequently, and the shredders and scrapers appeared frequently in the torrents. Among the habitat oriented groups, the clingers and burrower appeared more frequently and represented the microhabitats in the shallow areas. The result of the analysis of benthic macroinvertebrates community showed that the dominant index was $0.48{\pm}0.10$ in average while it was lowest with 0.33 in GS 8 of the Gwangneung Forest torrent and highest in BS 1 of Bongseonsa Stream. The diversity and richness indices were inversely proportional to the dominant index and were 2.53 and 4.22, respectively, in GS 8 where the dominant index was low. The result of the analysis of community stability showed that area I, which had high resistance and restoration, was high in Bongseonsa Stream while the area III, which had low resistance and restoration, was high in Gwangneung Forest, indicating that the water system in Gwangneung Forest had a wider distribution of specifies sensitive to agitation. The biological water quality assessment showed ESB of $50.88{\pm}17.69$, KSI of $1.11{\pm}0.57$, and BMI of $78.55{\pm}11.05$. GS 8 of Gwangneung Forest torrent was judged to be the highest priority protective water area with the best water environment and I class water quality with ESB of 63, KSI of 0.55, and BMI of 89.9. On the contrary, BS 1 of Bongseonsa Stream was judged to be the high priority improvement area that had the lowest water quality rating of III with ESB of 25, KSI of 2.13, and BMI of 62.7. Although the diversity of water beetle was higher in the water system of nearby Bongseonsa Stream than the water system inside the Gwangneung Forest, the annual community structure appeared to have distinct differences.