• 제목/요약/키워드: Bio-Signal

검색결과 665건 처리시간 0.022초

다양한 기저선을 갖는 1차 및 2차 미분계의 신호크기 및 신호 대 잡음비 조사 (Simulation of Signal Amplitudes and Signal-to-noise Ratios of $1^{st}$ order and $2^{nd}$ order Gradiometers with Various Baselines)

  • 강찬석;유권규;이용호;권혁찬;김진목;박용기;이순걸
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.40-44
    • /
    • 2007
  • We investigated signal-to-noise ratios (SNRs) of magnetocardiography (MCG) signals using the first-order and the second-order gradiometers of different baselines. The MCG signals were recorded using a measurement system with 61 magnetometers which measured the normal magnetic component to the chest surface. The distance between the chest surface and the bottom of the dewar was changed from 0 cm to 15 cm, and the MCGs were measured for each distance. By subtracting the other signals (distance = 1 to 15 cm) from the reference signal (distance =0 cm), we could simulate the first-order and the second-order gradiometer signals with various baselines. In addition, to evaluate the reproducibility of the simulation, we fabricated the wire wound first-order and second-order gradiometers which measured a normal magnetic component to the chest surface. The baselines of the first-order gradiometers were, respectively, 50 mm, 70 mm and 100 mm and the baseline of the second-order gradiometer was 50 mm. Using these gradiometers, we recorded the MCG signal and compared the SNR between the simulation and the measurement.

  • PDF

도플러 레이더 정보를 이용한 샘플링 시점 기반의 생체 신호 측정 알고리즘 개발 (Algorithm Development of Human Body Bio-Signal Measurement based on Sampling Time using Doppler Radar Information)

  • 유재춘;이명의
    • 한국항행학회논문지
    • /
    • 제24권4호
    • /
    • pp.322-327
    • /
    • 2020
  • 최근 도플러 레이더를 이용하여 생체 신호를 획득하는 연구가 개발되어 병상의 환자들에게 적용되는 기술로 사용되고 있다. 하지만 측정되는 맥박의 경우 호흡 신호가 잡음으로 발생하여 정확도가 낮아지는 문제가 발생한다. 본 논문에서는 도플러 레이더를 이용하여 생체신호를 측정할 때 맥박을 측정하기 위한 신호의 정확도를 향상시키기 위한 샘플링 시점 기반의 생체 신호 측정 알고리즘을 제안한다. 제안하는 알고리즘은 두 개의 샘플링 시점을 기반으로 생체 신호 측정 시 발생되는 잡음을 제거하여 측정 생체 신호의 정확도를 높이는 것으로 실제 의료 장비 및 기존 생체 신호 알고리즘과 비교하였을 때, 의료 장비와 90% 이상의 유사함을 보이며, 또한 기존 알고리즘에 비해 심한 진폭의 변화가 최소화 된 것을 확인하였다.

생체 신호 데이터의 의미 관계 표현 (Semantic Representation of Concept of Bio-signal Data)

  • 문경실;박수현
    • 한국정보통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.292-298
    • /
    • 2011
  • 생체신호 데이터의 의미와 그들 간의 연관관계를 정의하여 새로운 정보를 획득할 수 있는 형태의 모델링방법으로 온톨로지가 제시되고 있다. 온톨로지를 이용하여 생체신호 데이터를 지속적으로 관리함으로써 생체 신호 데이터의 체계적이고 논리적으로 표현이 가능하고, 이는 나아가 의료정보, 건강서비스 등 다양한 분야에서 질적으로 향상된 서비스를 제공하게 해주는 지식 자원으로 활용된다. 하지만 현재로는 생체 신호간의 연관 관계 중요성에 비해서 관련 연구가 활발하게 이루어지지 않고 있다. 따라서 생체 신호간의 연관관계를 찾아서 정의하고, 생체정보간의 의미표현이 필요하다. 그러기 위해서는 다양한 생체정보간의 연관 관계를 통해 체계적이고 구조화 된 정보를 만드는 것이 필요하다. 본 논문에서는 생체정보를 체계적이고 구조화 된 도메인 지식으로 활용하기 위한 모델로써 온톨로지를 이용하여 생체정보 온톨로지를 구축하고, 시나리오를 통해서 생체정보 온톨로지의 유용성을 검증하였다.

무선 통신망을 이용한 Cardiac Moniter (Cardiac Moniter Using Wirless Communication Network)

  • 신재호;이동화;강동주
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.175-177
    • /
    • 1996
  • 본 논문에서는 일반 심전도 모니터링 장비가 갖는 이동성 및 상시성의 제한을 극복하여 공중무선망을 이용한 심전도 모니터링 장치에 관한것으로서 특히, 활동중인 사람의 심전도 데이터를 공중 무선 통신망에서 제공하는 망써비스를 이용하여 원거리 모니터링 센터에서 모니터링 및 응급조치를 하는 시스템에 관한 것이다.

  • PDF

Wireless Bio-Signal Sensing System Using a Circular Polarized Antenna

  • Kwon Young-Bae;Park Jung-Min;Choe Jung-Hwan;Park Seong-Ook;Ishida Osami
    • Journal of electromagnetic engineering and science
    • /
    • 제5권3호
    • /
    • pp.132-139
    • /
    • 2005
  • Wireless bio-signal sensing system, which is based on the principle of Doppler radar, can measure a respiration and heart rates with a periodic movement of skin and muscle near the heart. Though the sensing monostatic system using a circulator has been studied, this bistatic system can be improved by using a circular polarized antenna which has a high isolation between transmitter and receiver. In this paper, we measured the bio-signal without the direct contact with the person. The design of each system and experimental results are discussed.

Multi-modal Authentication Using Score Fusion of ECG and Fingerprints

  • Kwon, Young-Bin;Kim, Jason
    • Journal of information and communication convergence engineering
    • /
    • 제18권2호
    • /
    • pp.132-146
    • /
    • 2020
  • Biometric technologies have become widely available in many different fields. However, biometric technologies using existing physical features such as fingerprints, facial features, irises, and veins must consider forgery and alterations targeting them through fraudulent physical characteristics such as fake fingerprints. Thus, a trend toward next-generation biometric technologies using behavioral biometrics of a living person, such as bio-signals and walking characteristics, has emerged. Accordingly, in this study, we developed a bio-signal authentication algorithm using electrocardiogram (ECG) signals, which are the most uniquely identifiable form of bio-signal available. When using ECG signals with our system, the personal identification and authentication accuracy are approximately 90% during a state of rest. When using fingerprints alone, the equal error rate (EER) is 0.243%; however, when fusing the scores of both the ECG signal and fingerprints, the EER decreases to 0.113% on average. In addition, as a function of detecting a presentation attack on a mobile phone, a method for rejecting a transaction when a fake fingerprint is applied was successfully implemented.

착용형 단말에서 다수 생체신호의 동시 측정을 가능하게 하는 플러그인 모듈 (The Plug-in Module for Simultaneous Monitoring of Multi Bio-signal in Wearable Devices)

  • 최문식;최동진;강순주
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제22권4호
    • /
    • pp.195-200
    • /
    • 2016
  • 스마트 워치, 스마트 밴드 같은 웨어러블 디바이스가 개발됨에 따라, 웨어러블 디바이스 사용자의 건강상태를 측정할 수 있는 생체신호 모니터링 기술이 각광 받고 있다[1]. 하지만 한 개의 웨어러블 디바이스에서 여러 가지 생체신호를 측정하기 위해 웨어러블 디바이스에 여러 가지 생체신호 센서를 내장하게 되면 디바이스 자체 크기와 같은 제한적인 자원 측면에서 문제가 발생한다. 또한 새로운 생체신호 센서를 추가 할 때 문제가 발생한다. 본 논문에서는 웨어러블 디바이스 사용자의 요청이 있을 때 가속도 센서, ECG 센서, PPG 센서를 Cradle형태의 모듈에서 동작시킨 후 사용한 센서에서 측정되는 생체 신호를 실시간으로 수집하여 다른 웨어러블 디바이스로 전송할 수 있는 플러그인(Plug-in) 모듈인 Bio-Cradle을 제안한다. Bio-Cradle은 다른 웨어러블 디바이스에 플러그인하면, 디바이스의 종류에 무관하게 동기화 된 다수 생체신호를 전송할 수 있다. 즉 Bio-Cradle을 사용함으로써, 다수 생체신호의 동시 측정이 가능해지고, 웨어러블 디바이스 내부에 생체신호 센서를 내장 할 필요가 없어진다.

생체신호 측정을 위한 최대의 신호 대 잡음비를 가지는 검출코일의 형태 와 자기차폐실의 최적 조합 (Optimum Combination of Pickup Coil Type and Magnetically Shielded Room for Maximum SNR to Measure Biomagnetism)

  • 유권규;이용호;강찬석;김진목;박용기
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.45-49
    • /
    • 2007
  • We have investigated the optimum combination of the environmental noise condition and type of SQUID pickup coil in order to obtain maximum signal-to-noise ratio (SNR). The measurement probe consists of 1st order gradiometer with pickup coils of 100 mm, 70 mm, and 50 mm baseline length, a 2nd order gradiometer with 50 mm baseline, and a magnetometer. The pickup coils are fabricated by winding Nb wire on a bobbin with 200 mm diameter. Noise and heart signal of a healthy male were measured by various SQUID sensors with different types of pickup coils in various magnetically shielded rooms (MSR), and compared to each other. The shielding factors were found to be 43 dB, 35 dB and 25 dB at 0.1 Hz for MSR-AS, MSR-BS, MSR-CS, respectively. White noises were $3.5\;fT/Hz^{1/2}$, $4.5\;fT/Hz^{1/2}$ and $3\;fT/Hz^{1/2}$ for the 1st order gradiometers, the 2nd order gradiometers, and magnetometer for all MSRs. SNR of the magnetometer was up to 56 dB in MSR-AS, while the 1st order axial gradiometer with 70 mm baseline length was up to 54 dB in MSR-BS. The 2nd order axial gradiometer with 50 mm baseline length of pickup coil was found to be up to 40 dB in MSR-CS.

  • PDF

허혈에 의한 다채널 심자도의 ST-T 변화 (ST-T Changes of Multichannel Magnetocardiographic Pattern in Myocardial Ischemia)

  • 권혁찬;김기웅;이용호;김진목;임현균;박용기;정남식;고영국;정보영;김진배;조정래
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.35-39
    • /
    • 2007
  • Myocardial ischemia causes heterogeneity of ventricular repolarization and sometimes produces changes of the ST-T wave in ECG. Therefore, morphological changes of ST-T waveform in ECG have a clinical significance in diagnosing myocardial ischemia. In this study, we investigated the ST-T changes caused by myocardial ischemia in magnetocardiography (MCG). We analyzed MCG patterns of biphasic T, ST segment deviations from baseline, main current angle of $T_{peak}$ and $T_{peak}$ dispersion in 300 CAD patients without ST elevation in ECG, 122 symptomatic patients and 48 normal subjects. MCGs were recorded by multichannel SQUID system in a magnetically shielded room. As results, we found that appearances of the abnormality were strongly correlated with the severity of myocardial ischemia. Also we found that the percentage of the patients showing MCG changes were higher than those in ECG. These results show that morphological changes of ST-T waveform in MCG can be used as a marker of myocardial ischemia.

  • PDF