Time Series Evaluation of Visual Fatigue and Depth Sensation Using a Stereoscopic Display

  • Kim, Sang-Hyun;Kishi, Shinsuke;Kawai, Takashi;Hatada, Toyohiko
    • Journal of Information Display
    • /
    • 제10권4호
    • /
    • pp.188-194
    • /
    • 2009
  • Conventional stereoscopic (3D) displays using binocular parallax generate unnatural conflicts between convergence and accommodation. These conflicts can affect the observer's ability to fuse binocular images and may cause visual fatigue. In this study, time series changes in visual fatigue and depth sensation when viewing stereoscopic images with changing parallax were examined. In particular, the physiological changes, including the subjective symptoms of visual fatigue, when viewing five parallax conditions, were examined. Then a comparative analysis of the 2D and 3D conditions was performed based on the visual function. To obtain data regarding the visual function, the time series changes in the spontaneous-blinking rate before and during the viewing of 3D images were measured. The time series change results suggest that 2D and 3D images cause significantly different types of visual fatigue over the range of binocular disparity.

Development of Training Instruments on Visual functions using HMD type Display and Investigation of its Demand

  • Lee, Seong Jae;Oh, Se Hyun
    • International Journal of Advanced Culture Technology
    • /
    • 제6권3호
    • /
    • pp.201-210
    • /
    • 2018
  • We constructed 3-D images by HMD (Head Mount Display) type and polarization technique through which a training instrument of binocular function based on clinical vision therapy was developed and investigated its demand. To design the instrument that performs Test- Diagnosis - (Prescription) - Training - Treatment we provided a customized training method for the trainers using optical IT instruments of binocular test. Through the contents and the instruments of the vision therapy technology developed in this work we can replace the current vision test instruments to those costing 60% lower price in eye clinics and eye glasses shops. By replacing the existing vision test instruments it is possible to create a new market of the vision therapy in vision training instruments.

시기능 검사값의 상관관계 분석 (Analysis of Correlation of Visual Function Findings)

  • 박현주
    • 한국안광학회지
    • /
    • 제10권4호
    • /
    • pp.381-389
    • /
    • 2005
  • 근거리에서 폭주와 조절 상태를 평가하여 시기능 검사값의 상관관계를 분석하고자 안질환이 없는 성인남녀 92명에 대해 양안 완전 교정 후 양안 균형을 취한 굴절 교정 도수를 시험테에 장용 시킨 후, 근거리(40 cm)에서 MEM 검영법 및 Bell 검영법(Welch Allyn, USA), 조절 용이성 검사(${\pm}2.00$ D Flipper, Bernell Co., USA), 버전스 용이성 검사(Prism Flipper, Bernell Co., USA)를 실시하였다. MEM 검영법에 의한 조절래그 검사는 양안이 같은 수준의 조절반응을 보였고, Bell 검영법에 의한 양안의 조절래그는 MEM의 결과보다 매우 높은 상관관계를 보였다. 조절래그가 낮을수록 조절 용이성은 높고, 편광을 이용한 양안 조절 용이성이 적녹을 이용한 양안 조절용이성보다 높았다. 단안 조절 용이성은 좌 우안 사이에 높은 상관관계를 보여 차이가 없음을 보였으며, 단안 조절 용이성이 높을수록 양안 조절 용이성도 높았다. 또한 단안 양안 조절 용이성이 높을수록 버전스 용이성도 높은 것으로 나타났다. 이 시기능 검사값은 환자의 시기능 치료에 임상적 가이드가 될 수 있을 것으로 사료된다.

  • PDF

시기능 훈련방법에 의한 양안시 기능적.감각적 증상 개선 효과 연구 (The Study on the Improvement of Function and Sensation Symptoms of Binocular Vision for Vision Training Methods)

  • 이창선;김기홍
    • 한국안광학회지
    • /
    • 제15권2호
    • /
    • pp.185-193
    • /
    • 2010
  • 목적: 이 연구의 목적은 시기능 훈련 대상자들의 시기능 훈련방법의 차이에 따른 시기능 증상 개선 효과를 조사하였다. 방법: 시기능 훈련 대상자는 안질환과 조절이상 및 수직사위가 없는 양안시 이상자 35명을 대상으로 추적 관찰하였고, 훈련기간은 8주간 매주 한번은 안경원에 방문하여 시기능 훈련에 따른 변화를 측정하였다. 결과: 시기능 훈련 대상자의 시기능 훈련방법의 차이에 따른 기능적 및 감각적 증상이 개선되었다. 그리고 Worth 4 Dot검사, 입체시 검사 및 적색렌즈 융합 속도 검사는 유사한 결과를 보여 주었다. 결론: 본 연구에서 시기능 훈련 방법에 따라 환자의 사위량, 기능적 및 감각적 증상 변화가 있는 것으로 나타났다.

Convergence Point Adjustment Improving Visual Discomfort for a Zoom on a Stereoscopic Camera

  • Ha, Jong Soo;Kim, Dae Woong;Kim, Dong Hyun
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.633-640
    • /
    • 2016
  • In a dual lens stereoscopic camera, a convergence point determines the stereopsis effects of a video. When a user zooms an object, a convergence point is fixed since it is not coupled with a zoom function. Due to the fixed convergence point, it is possible for a zoom to cause the excessive binocular disparity resulting in visual discomfort. In this paper, to solve this problem, we build the relational model including all phenomena possible to arise and propose the adjustment methods of a convergence point by the positions of a focus, an object and a convergence point. We also evaluate the experiments measuring a binocular disparity and the subjective test to investigate the visual comfort. The results show that one of the proposed methods produced more comfortable 3D images to viewers than the others.

시기능 훈련 대상자의 훈련 충실도 비교 분석 (Comparative Analysis of the Training Fidelity of Vision Training Trainee)

  • 김기홍;이창선;이재윤
    • 한국안광학회지
    • /
    • 제14권2호
    • /
    • pp.47-51
    • /
    • 2009
  • 목적: 이 연구의 목적은 시기능 훈련 대상자들의 충실도에 따른 시기능 훈련 효과를 조사하였다. 방법: 시기능 훈련 대상자는 안질환과 조절이상 및 수직사위가 없는 양안시 이상자 75명(남자 40명, 여자 35명)을 대상으로 추적 관찰하였고, 훈련기간은 7주(49일)간 매주 한번은 원에 방문하여 시기능 훈련에 따른 변화를 측정하였다. 결과: 시기능 훈련 대상자의 원 방문율과 충실도가 높을수록 기능적이상, 감각적이상 및 자각적 증상이 개선되었다. 그리고 성공기준에 포함률도 높게 나타났다. 결론: 효과적인 양안시 이상을 개선하기 위하여서는 충실도를 높이는 방법이 중요하다.

  • PDF

Monocular 3D Vision Unit for Correct Depth Perception by Accommodation

  • Hosomi, Takashi;Sakamoto, Kunio;Nomura, Shusaku;Hirotomi, Tetsuya;Shiwaku, Kuninori;Hirakawa, Masahito
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1334-1337
    • /
    • 2009
  • The human vision system has visual functions for viewing 3D images with a correct depth. These functions are called accommodation, vergence and binocular stereopsis. Most 3D display system utilizes binocular stereopsis. The authors have developed a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  • PDF

시기능 훈련 시스템을 이용한 훈련 효과에 관한 연구 (The Study on the Effect of Vision Training System)

  • 이창선;손정식;김인수;강성수;이동희;김기홍
    • 한국안광학회지
    • /
    • 제14권1호
    • /
    • pp.81-86
    • /
    • 2009
  • 목적: 본 연구는 새롭게 개발한 MYSTERY CIRCLE, Anaglyphs 및 Block string을 이용하여 양안시 기능적, 감각적, 증상 변화에 대해 비교 관찰하고, 훈련방식별 개선효과와 실용 가능성을 알아보고자 하였다. 방법: 대상자는 T안경원의 75명의 시기능 훈련 대상자(남자 40명, 여자 35명)이며 7주(49일)동안 시기능 훈련을 실시하였다. 결과: 모든 훈련방식(MYSTERY CIRCLE, Anaglyphs, Block string)에서 시기능 훈련자의 양안시 개선에 도움이 되었으나, 정상화 성공기준에 포함된 대상자수를 비교한 결과 MYSTERY CIRCLE훈련이 유의수준 0.05에서 다른 훈련방식과 유의한 차이를 보였다. 결론: 본 연구에서 MYSTERY CIRCLE 훈련이 양안시 이상자의 시기능 개선 및 정상화에 우수한 개선효과가 있는 것으로 나타났다.

  • PDF

무안군 소재 초등학생들의 시훈련 효과에 관한 연구 (The Study on Effects of After Vision Training for Elementary School Children in Muan)

  • 장정운;김인숙
    • 한국안광학회지
    • /
    • 제18권2호
    • /
    • pp.137-142
    • /
    • 2013
  • 목적: 무안군내 초등학교 학생들의 시력상태를 파악하고, 조절력과 버전스 부족 학생들의 시훈련 후의 시기능 향상에 관하여 알아보고자 한다. 방법: 무안군내 초등학교 1학년~6학년까지 약 335명을 대상으로 자각적 타각적 굴절검사, 양안시기능검사 실시 후 시기능이상 증상을 호소하는 47명을 대상으로 시기능 훈련 실시 후 각 검사 결과를 비교 분석하였다. 결과: 본 연구 대상 학생들의 대부분은 조절력보다는 폭주근점에서 문제를 나타내었다. 폭주근점은 훈련 전 $11.57{\pm}1.850$ cm에서 훈련 후 $5.66{\pm}0.965$ cm로 나타나 약 5.93 cm 정도 폭주근점이 당겨진 것을 알 수 있었고, 근거리의 양성융합 버전스는 훈련 후 사위량의 2배 값인 약 $19.64{\pm}3.66$ $\Delta$를 나타내었다. 조절력은 훈련 전 약 $10.02{\pm}2.566$ D에서 훈련 후 $12.30{\pm}1.397$ D 정도로 개선되어 평균연령 11.27세의 조절력 기대치와 비슷함을 나타내었다. 결론: 조절력과 융합버전스 부족 중에서 특히 폭주근점이 큰 폭으로 상승하였고, 조절용이를 포함한 대부분 시기능 항목들도 향상된 수치를 나타낸 것으로 보아 시훈련은 많은 효과가 있었다고 사료된다.

폭주근점 변화의 AC/A비 대체 평가지표에 대한 가능성 (Possibility about evaluation test of Substitution of NPC Alteration for AC/A Ratio)

  • 유현;이은희
    • 디지털융복합연구
    • /
    • 제14권10호
    • /
    • pp.375-380
    • /
    • 2016
  • 본 연구에서는 폭주근점 변화를 통해 양안시 기능 평가의 가능성을 확인하고자 하였다. 연구대상자는 사위를 제외한 안질환이 없고 단안교정 소수 시력 1.0 이상인 30명(정시 16명, 근시 14명)이었다. 조절근점과 폭주근점, 사위검사는 평상시와 +1D의 자극 시에 측정하였다. 대상자의 폭주근점은 +1D의 자극 시 폭주근점보다 1.77cm 작게 나타났고, 근시보다 정시에서 폭주근점이 작게 나타났다. 정시 대상자에서 폭주근점과 +1D의 자극 시 폭주근점의 차이는 증가하였다. 폭주근점이 커질수록 근거리 외사위에 가까워졌으며, AC/A비는 크게 나타났다. 연구결과는 폭주근점 변화가 양안시의 참조변수인 AC/A비를 대체할 수 있는 것을 보여주었다. 다른 양안시 기능 평가 검사들과 융합하고 비교분석한다면, NPC 변화는 대체 평가지표로써 개발될 수 있을 것이다.