• Title/Summary/Keyword: Binocular

Search Result 324, Processing Time 0.035 seconds

Effect of Overcorrection (-)Lens on Stereo-acuity and Angle of Deviation in Intermittent Exotropia (간헐외사시에서 과교정 (-)렌즈가 입체시 및 사시각에 미치는 영향)

  • Kim, Young Cheong;Park, Sang Woo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the effect of prescription of overcorrection (-) lens, which is the one of the non-surgical treatments, on stereo-acuity and angle of deviation in intermittent exotropia. Methods: Twenty four children with intermittent exotropia were enrolled from October 2011 to December 2011. The angle of deviation(${\Delta}$), stereo-acuity (arcsec), monocular and binocular visual acuity (BVA, LogMAR), control of exodeviation and fusional ability using Worth 4 dot test were evaluated at near (33 cm) and far (6 m), under the overcorrecting (-)lens of -1.00, -.00, and -.00 D. Results: As a baseline finding, the angle of exodeviation was $20.9{\pm}9.7$ at near and $23.0{\pm}7.5$ at far. The angle of exodeviation at near decreased to $18.5{\pm}10.0$ (p<0.01), $15.8{\pm}9.0$ (p<0.01), $14.0{\pm}9.1$ (p<0.01) compared with baseline angle of exodeviation at near, as increasing diopters of (-) lens from -.00 D, -2.00 D and -.00 D, respectively. The angle of exodeviation at far also decreased to $21.4{\pm}5.2$ (p=0.01), $19.6{\pm}6.3$ (p<0.01) compared with baseline, as increasing minus lens from -2.00 D and -3.00 D, respectively. However, BVA, control of exodeviation, fusional ability and stereo-acuity showed no significant decrease despite of increasing diopters of (-)lens. Conclusions: The prescription of overcorrection (-)lens is an effective therapeutic method in intermittent exotropia which can reduce the near and far angle of exodeviation, and binocular visual acuity and stereo-acuity maintained without significant decrease despite of application of overcorrection (-)lens.

Characteristics of Visual Attention for the Different Type of Material Finishing in Cafe Space Using by Eye-tracking (시선추적을 이용한 카페 공간 마감재 차이의 시각주의력 특성)

  • Choi, Jin-Kyung;Kim, Ju-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • This study aims to investigate whether there is intensionally changing eye - gaze on the cafe space images with floor finishing materials. In the Yarbus' experiment, he argued that changing information that an observer is asked to obtain from an image changes pattern of eye movements. Based on the scan path evidence, this research have questions as (1) the difference of visual attention on finishing floor material stimulus, (2) visual attention of initial activity time and type of movement paths on AOIs, and (3) visual relation floor area with another AOIs. Eye movements were recorded with the SMI REDn Scientific, which sampled eye position at 30Hz and lasted 2 minutes(120s). Although viewing was binocular, only the right eye was tracked. Of the 66 observers(mean age 22 years, standard deviation: ${\pm}1.82$) who participated in the experiment done by the four point calibration and validation procedures at the beginning tasks. Analyzing qualitative data from the number of fixation and duration on AOIs divided into four parts (AOI I-Floor, AOI II-Wall, AOI III-Ceiling, and AOI IV-Counter) in the stimulus. The results from this experiment analyzed as follows. First, it was significant in the difference of the average number of AOIs fixation times observed for the spatial image using the wood tile flooring material and the polishing tile. The wood tile flooring of stimulus had higher fixation number on AOI-II, AOI-III, and AOI-IV than the polishing tile. On seeing AOI-I was higher attention in the polishing tile stimulus. Second, the observers examined AOI-II intensively in both stimuli. However, the visual intensity was also followed by on the AOI-IV and AOI-I in the wood tile flooring stimulus, and on AOI-I, AO-IV in the polishing tile. Third, visual attention data on each AOIs have divided into the time range of "5 sec" for both images. In the wood tile stimulus, the horizontal movement path followed by AOI-II, AOI-IV, and AOI-II. In the polished tile stimulus, the movement path followed by moving vertically to AOI-II, AOI-I, and AOI-II. This study approached meaningfully and found out the characteristics of visual attention, according to the different intentions of visual attention, the relationship pathways of visual mechanism appeared and also activated by eye-tracking experiments.

Analysis of Teaching Behavior and Visual Attention according to Teacher's Career in Elementary Science Inquire-based Class on Respiration (탐구형 초등과학수업 '호흡' 차시에서 교사의 경력에 따른 교수행동 및 시각적 주의 분석)

  • Kim, Jang-Hwan;Shin, Won-Sub;Shin, Dong-Hoon
    • Journal of Korean Elementary Science Education
    • /
    • v.37 no.2
    • /
    • pp.206-218
    • /
    • 2018
  • The purpose of this study is to analyze the teaching behaviors and visual attention according to teacher's career in Elementary Science Inquire-based Class. Participants were four elementary school teachers in Seoul. They were all in grade 5 and taught science. According to the experience of elementary science education, two novice teachers and two expert teachers were identified. Participants taught Respiration in the 'Structure and Function of our Body' in the elementary science fifth grade. The mobile eye tracker used in this study is SMI's ETG 2w, which is a binocular tracking system. In addition, a video camera was installed behind the classroom to record the entire class. We recorded all the contents of the recorded video and analyzed the results. In this study, the actual practice time, participant's visual attention, and decentralized attention ability were analyzed by class phase. The results of the study are as follows. First, there was a difference between planned class time and actual practice time. The novice teachers were having difficulty in reconstructing the contents of education, and the expert teachers were reconstructing the curriculum and interacting with the students with high understanding and application of the curriculum. There were many differences between the novice teachers and the expert teachers in the tour guidance to confirm student activities. Second, if we look at the visual attention on the area related to teaching and learning by class phase, the novice teacher concentrates all the steps in a specific area, expert teachers showed an equal visual attention to meaningful areas of teaching and learning activities. Third, there was a statistically significant difference in activities 1-1, 1-2, 2-1, and 2-2 when the participants' decentralized attention ability. Expert teachers frequently checked students' understanding and interests. There was a lot of interaction with students. It is also shown through the decentralized attention ability that the novice teachers concentrate on a specific area, and the expert teachers have a high degree of decentralized attention ability and visual attention evenly.

A Stereo Video Avatar for Supporting Visual Communication in a $CAVE^{TM}$-like System ($CAVE^{TM}$-like 시스템에서 시각 커뮤니케이션 지원을 위한 스테레오 비디오 아바타)

  • Rhee Seon-Min;Park Ji-Young;Kim Myoung-Hee
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.6
    • /
    • pp.354-362
    • /
    • 2006
  • This paper suggests a method for generating high qualify stereo video avatar to support visual communication in a CAVE$^{TM}$-like system. In such a system because of frequent change of light projected onto screens around user, it is not easy to extract user silhouette robustly, which is an essential step to generate a video avatar. In this study, we use an infrared reflective image acquired by a grayscale camera with a longpass filter so that the change of visible light on a screen is blocked to extract robust user silhouette. In addition, using two color cameras positioned at a distance of a binocular disparity of human eyes, we acquire two stereo images of the user for fast generation and stereoscopic display of a high quality video avatar without 3D reconstruction. We also suggest a fitting algorithm of a silhouette mask on an infrared reflective image into an acquired color image to remove background. Generated stereo images of a video avatar are texture mapped into a plane in virtual world and can be displayed in stereoscopic using frame sequential stereo method. Suggested method have advantages that it generates high quality video avatar taster than 3D approach and it gives stereoscopic feeling to a user 2D based approach can not provide.

Analysis of Refractive Status between Urban and Rural Region in 13-year-old Children (도시와 농촌의 13세 어린이에 대한 굴절상태 분석)

  • Kim, Douk-Hoon;Kim, Jung-Sook
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.1
    • /
    • pp.808-815
    • /
    • 2017
  • Purpose. To analyze the refractive status between urban and rural regions, of children in Korea, in the age group of 13. Methods. From October 2016 to January 2017, forty subjects( 20 male subjects, 20 female subjects; 13 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+1.00D$, cylinder error ${\geq}0.75D$ and SE difference${\geq}1.00D$ between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 76.25%, astigmatism 35%, emmetropia 16.25%, anisometropia 8.75%, and hyperopia 5%. The prevalence of myopia and astigmatism were much more common in urban than rural region although the difference was not statically significant. Emmetropia and astigmatism were much more common in rural region than urban although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to -4.00 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between OD and OS of rural region in the spherical equivalent power(p<.000). Also, There was a statistical significance between OD and OS of urban region in the spherical equivalent power(p<.004). Therefore, there was a significant statistical similarity between urban and rural regions on the OD and OS in the spherical equivalent power. On the other hand, There was a significant statistical similarity between urban and rural regions of the OD and OS in the astigmatism power(p<0.000). However, in the rural and urban regions there was not statistical significance in the OD and OS concerning the spherical equivalent power and astigmatism power (p>0.1). Conclusions. Myopia was the most common refractive error in Korea young children. while hyperopia was few. There was not a statistical significance as age between rural and urban at spherical equivalent power( P> 0.01). These results suggested that the analysis of the refractive status at young children can give the useful diagnosis data for the correction of visual acuity.

Geometric analysis and anti-aliasing filter for stereoscopic 3D image scaling (스테레오 3D 영상 스케일링에 대한 기하학적 분석 및 anti-aliasing 필터)

  • Kim, Wook-Joong;Hur, Nam-Ho;Kim, Jin-Woong
    • Journal of Broadcast Engineering
    • /
    • v.14 no.5
    • /
    • pp.638-649
    • /
    • 2009
  • Image resizing (or scaling) is one of the most essential issues for the success of visual service because image data has to be adapted to the variety of display features. For 2D imaging, the image scaling is generally accomplished by 2D image re-sampling (i.e., up-/down-sampling). However, when it comes to stereoscopic 3D images, 2D re-sampling methods are inadequate because additional consideration on the third dimension of depth is not incorporated. Practically, stereoscopic 3D image scaling is process with left/right images, not stereoscopic 3D image itself, because the left/right Images are only tangible data. In this paper, we analyze stereoscopic 3D image scaling from two aspects: geometrical deformation and frequency-domain aliasing. A number of 3D displays are available in the market and they have various screen dimensions. As we have more varieties of the displays, efficient stereoscopic 3D image scaling is becoming more emphasized. We present the recommendations for the 3D scaling from the geometric analysis and propose a disparity-adaptive filter for anti-aliasing which could occur during the image scaling process.

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

Screen Disparity and Size Perception Function of Various 3D Stimuli (양안시차에 따른 다양한 3D 자극의 크기지각 예측함수 개발)

  • Park, JongJin;Li, Hyung-Chul O.;Kim, ShinWoo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.1
    • /
    • pp.66-76
    • /
    • 2013
  • Although there has been much advance in the development of 3D displays of various purpose, 3D contents are not yet so used as expected in those displays. One well-known obstacle in the enjoyment of 3D contents is visual fatigue, but another major issue is image distortion of 3D contents. In the previous research, Shin, Li, & Kim (2012) reported systematic linear relationship between screen disparity and size perception of a simple object whose retinal size was constant across different disparities. In this research, we intended to generalize the previous finding by using various 3D stimuli in the test of the relationship between screen disparity and size perception of those stimuli. Consistent with previous findings, our data indicated that size perception linearly changes as a function of screen disparity and the linearity was observed in all stimuli types we used in this research. We described the empirical relationship between screen disparity and size perception in the form of prediction function for size perception in which visual angle is the predictor. This function will be very useful in the creation of 3D contents as one can make reasonable predictions on the to-be-perceived size of an object being filmed using screen disparity of their camera setting.

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

A Comparison of Refractive Components in Anisometropia and Isometropia (굴절부등안과 동등안의 양안 굴절요소 차이 비교)

  • Shim, Hyun-Seog;Shim, Jun-Beom;Kim, Eun-Suck
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • Purpose: This study was to compare differences between both eyes in corneal powers, axial lengths, anterior chamber depths in anisometropia and isometropia, and to investigate the relationship between anisometropia and refractive components. Methods: The subject was a total of 83 patients, anisometropia 45 patients (90 eyes) and isometropia 38 patients (76 eyes) from 2.7 to 15.3 years old, prescribed eyeglasses and contact lenses by refraction from July 2010 to August 2010 in Gwangju City B eye clinic. Axial length, anterior chamber depth, corneal curvature, and corneal refractive power were measured using IOL Master. Refractive error was measured using an Auto-refractometer. Results: Anisometropia was a statistically significant difference in axial length, binocular refractive components, refractive error, and axial length, Axial length/corneal radius (AL/CR) ratio showed a statistically significant difference in anisometropia and isometropia. The major cause of anisometropia all 45 subjects was the axial length. Among the refractive components axial length, AL/CR had a strong correlation, but corneal refractive power had no correlation. Anterior chamber depth had a weak correlation. Conclusions: This study found that refractive error was the most axial ametropia caused by the axial length. The main cause of anisometropia was the axial length, but refractive components had a weak correlation.