• 제목/요약/키워드: Binary gas

검색결과 152건 처리시간 0.025초

원추형 분립유동층에서 미세 분체의 수력학적 특성 (Hydrodynamic Characteristics of Fine Powders in the Conical Powder-Particle Fluidized Beds)

  • 이동현;신문권;김은미;손승용;박병섭;한귀영;윤기준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.310-313
    • /
    • 2005
  • The conical fluidizing system of a binary mixture of Geldart C powders and Geldart A particles was defined as the conical powder-particle fluidized bed. We used a cold conical powder-particle fluidized bed model having a 0.104m-I.D. and 0.6m-high with an apex angle of $10^{\circ}$ for fluidization of a binary powder-particle mixture of 50 $vol\%$ fine carbon black powders (HI-900L, Korea Carbon Black Co.) and coarse alumina particles $(90{\mu}m)$ under different superficial gas velocities (0-0.1 m/s). The differential bed pressure drop increases with increasing gas velocity, and it goes from zero to a maximum value with increasing or decreasing gas velocity. In the conical fluidized beds of fine powders, demarcation velocities of the partial fluidization, full fluidization, partial defluidization was not observed.

  • PDF

The characteristics of AC-PDPs According to binary and ternary gas mixtures of He-Ne-Xe_

  • Lee, H.J.;Son, C.G.;Lee, S.B.;Han, Y.K.;Jeoung, S.H.;You, N.L.;Lim, J.E.;Lee, J.H.;Moon, M.W.;Oh, P.Y.;Jeoung, J.M.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1195-1198
    • /
    • 2005
  • The improvement of efficiency is the one of the most important part in AC PDPs . To achieve high efficiency, high VUV emission efficiency and High ion induces secondary electron emission coefficient are needed. We have measured the emission spectra of vacuum ultraviolet rays and ion induced secondary electron emission coefficient of MgO protective layer in surface discharge AC-PDP with binary and ternary gas mixtures. We have investigated electro-optical characteristics of AC-PDPs to optimum gas mixture for high efficient.

  • PDF

이산화탄소와 에탄 이성분계의 기액 상평형 연구 (A Study on the Vapor-Liquid Equilibria for the Binary Sustem of Carbon Dioxide and Ethane)

  • 김동선;조정호
    • 한국가스학회지
    • /
    • 제14권5호
    • /
    • pp.32-37
    • /
    • 2010
  • 본 연구에서는 이산화탄소와 에탄 이성분계에 대해서 여러 등온 조건하에서 기액 상평형을 PRO/II with PROVISION (PRO/II) 전산 모사기에 내장되어 있는 Peng-Robinson (PR) 상태방정식의 이성분계 상호작용 매개변수를 이용하여 추산하였다. 또한, 이산화탄소와 에탄 이성분계의 각각의 등온 기액 상평형에 대해서 기포점 압력의 편차의 제곱에 대한 합산값을 목적함수로 하여 PR 상태방정식의 이성분계 상호작용 매개변수를 회귀분석을 통하여 새로 결정하였다. 기존의 PRO/II에 내장되어 있는 이성분계 상호작용 매개변수를 사용한 것과 새로 결정한 매개변수를 사용하여 기포점 압력의 편차의 절대값에 대한 평균값을 각각 비교하였다. 본 연구에서 새로 결정한 매개변수를 이용하여 추산한 결과가 기존의 PRO/II에 내장되어 있는 매개변수를 이용하여 추산한 결과보다 우수함을 알 수 있었다.

다양한 형태의 금속 산화물을 이용한 Pd계 복합 수소분리막의 2원계 중간층 형성에 관한 연구 (A Study of the Formation of Binary Intermediate Layer on Pd-based Hydrogen Separation Membrane Using Various Types of Metal Oxides)

  • 황인혁;김성수
    • 공업화학
    • /
    • 제29권2호
    • /
    • pp.196-200
    • /
    • 2018
  • 본 연구에서는 복합 수소분리막 중간층의 pin hole, crack 및 defect를 최소화하기 위하여 powder type과 sol type의 금속산화물을 이용하여 복합화하였다. 중간층의 표면 형상과 투과 특성은 주사전자현미경(SEM) 분석과 $N_2$ 투과도 테스트를 통해 평가하였으며, 제조한 수소분리막의 성능평가를 위해 $N_2$$H_2$를 이용하여 단일가스 투과 테스트를 수행하였다. Powder type과 sol type의 금속산화물을 각각 이용하여 중간층을 적층한 결과 sol type 금속산화물을 이용하여 적층한 중간층의 표면 조도가 매우 낮았으며, 특히 $TiO_2$ sol로 형성된 중간층의 pin-hole, crack 및 defect가 현저히 감소하였다. Powder와 sol을 복합화하여 적층한 중간층은 sol로 형성된 중간층과 거의 유사한 특성을 보였으며, 이를 기반으로 제조한 수소분리막은 1 bar의 압력구배, 672 K의 온도에서 약 $0.32mol/m^2s$의 수소 투과도를 나타내었으며, 선택도는 약 10,890 이상으로 측정되었다.

NMF를 포함하는 이성분계의 등온 기-액 평형과 삼성분계 액-액 평형 (Binary Vapor-Liquid Equilibria and Ternary Liquid-Liquid Equilibria for NMF Contained Systems)

  • 박소진;한규진;원동복;오종혁;최영윤
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.259-265
    • /
    • 2005
  • Water+n-methylformamide(NMF), benzene+NMF 그리고 toluene+NMF의 353.15 K 이성분계 등온 기-액상평형을 headspace gas chromatography(HSGC)로 측정하였고, NMF+benzene+n-heptane과 NMF+toluene+n-heptane 삼성분계에 대한 298.15 K 액-액상평형을 tie-line 측정법으로 결정하였다. 이성분계 기-액상평형 데이터는 공비점이 없었으며, $g^E$ 모델식(Margules, van Laar, Wilson, NRTL, UNIQUAC)에 비교적 작은 편차로 잘 상관되었다. 삼성분계 tie-line 데이터는 NRTL식과 UNIQUAC식을 이용하여 상관과 추산을 병행하였으며, Hirata-Fujita식과 Maior-Swenson식을 이용하여 정확도를 검증하였다.

Sensing Characterization of Metal Oxide Semiconductor-Based Sensor Arrays for Gas Mixtures in Air

  • Jung-Sik Kim
    • 한국재료학회지
    • /
    • 제33권5호
    • /
    • pp.195-204
    • /
    • 2023
  • Micro-electronic gas sensor devices were developed for the detection of carbon monoxide (CO), nitrogen oxides (NOx), ammonia (NH3), and formaldehyde (HCHO), as well as binary mixed-gas systems. Four gas sensing materials for different target gases, Pd-SnO2 for CO, In2O3 for NOx, Ru-WO3 for NH3, and SnO2-ZnO for HCHO, were synthesized using a sol-gel method, and sensor devices were then fabricated using a micro sensor platform. The gas sensing behavior and sensor response to the gas mixture were examined for six mixed gas systems using the experimental data in MEMS gas sensor arrays in sole gases and their mixtures. The gas sensing behavior with the mixed gas system suggests that specific adsorption and selective activation of the adsorption sites might occur in gas mixtures, and allow selectivity for the adsorption of a particular gas. The careful pattern recognition of sensing data obtained by the sensor array made it possible to distinguish a gas species from a gas mixture and to measure its concentration.

Analysis of Insulating Characteristics of Cl2-He Mixture Gases in Gas Discharges

  • Tuan, Do Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1734-1737
    • /
    • 2015
  • Insulating characteristics of Cl2-He mixture gases in gas discharges were analysed to evaluate ability of these gases for using in medium voltage and many industries. These are electron transport coefficients, which are the electron drift velocity, density-normalized longitudinal diffusion coefficient, and density-normalized effective ionization coefficient, in Cl2-He mixtures. A two-term approximation of the Boltzmann equation was used to calculate the electron transport coefficients for the first time over a wide range of E/N (ratio of the electric field E to the neutral number density N). The limiting field strength values of E/N, (E/N)lim, for these binary gas mixtures were also derived and compared with those of the pure SF6 gas.

ethanol + $CH_4$ 하이드레이트 시스템의 미세 분광학적 연구 (Microscopic investigation on the binary ethanol + $CH_4$ Hydrate system)

  • 이종원;강성필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.149.1-149.1
    • /
    • 2010
  • 가스 하이드레이트는 작은 고체 부피 내에 막대한 양의 가스를 저장할 수 있다는 특징으로 인하여 최근 주목을 받고 있지만, 엔지니어링 분야에서는 천연가스 수송 파이프라인에 blockage problem을 일으키는 해로운 물질로 처음 관심을 받았다. 이러한 문제를 해결하기 위한 방법으로 초기에는 하이드레이트 형성영역을 벗어나도록 온도, 압력을 유지하기도 하였으나, 최근에는 다양한 형성 억제제가 사용되고 있다. 본 연구에서는 기존에 억제제로 알려져 있는 대표적인 알코올 화합물인 에탄올을 이용하여 고압의 메탄과 binary 하이드레이트의 형성 연구를 수행하였다. 다양한 농도의 에탄올을 이용하여 형성된 하이드레이트 샘플은 고체 NMR 분석을 통하여 분자 거동을 자세히 측정하였으며, 분말 XRD 분석을 통하여 헝성된 미세 결정 구조도 확인하였다. 본 연구에서 얻어진 결과는 에탄올 및 알코올 화합물의 가스 하이드레이트 형성 거동 및 binary guest 시스템에서의 tuning 효과에 대한 유용한 정보를 제시할 수 있을 것이라 판단된다.

  • PDF

Identification of Gas Mixture with the MEMS Sensor Arrays by a Pattern Recognition

  • Bum-Joon Kim;Jung-Sik Kim
    • 한국재료학회지
    • /
    • 제34권5호
    • /
    • pp.235-241
    • /
    • 2024
  • Gas identification techniques using pattern recognition methods were developed from four micro-electronic gas sensors for noxious gas mixture analysis. The target gases for the air quality monitoring inside vehicles were two exhaust gases, carbon monoxide (CO) and nitrogen oxides (NOx), and two odor gases, ammonia (NH3) and formaldehyde (HCHO). Four MEMS gas sensors with sensing materials of Pd-SnO2 for CO, In2O3 for NOX, Ru-WO3 for NH3, and hybridized SnO2-ZnO material for HCHO were fabricated. In six binary mixed gas systems with oxidizing and reducing gases, the gas sensing behaviors and the sensor responses of these methods were examined for the discrimination of gas species. The gas sensitivity data was extracted and their patterns were determined using principal component analysis (PCA) techniques. The PCA plot results showed good separation among the mixed gas systems, suggesting that the gas mixture tests for noxious gases and their mixtures could be well classified and discriminated changes.