• Title/Summary/Keyword: Binary Mixtures

Search Result 336, Processing Time 0.036 seconds

Study of the Partial Miscibilities of Binary Liquid-liquid Systems Predicted by the Extended Flory-Huggins Lattice Theory (확장된 Flory-Huggins의 격자이론에 의해 예측되는 액체 이성분계의 부분혼화도에 대한 고찰)

  • Hae-Young Jung
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.481-485
    • /
    • 1987
  • Various partial miscibilities of binary liquid mixtures predicted by the extended Flory-Huggins lattice theory are shown in this article, and the mathematical conditions for each partial miscibility are obtained. And in terms of the theory it is shown that the unusual partial miscibility of water-2-butanol system can occur.

  • PDF

Phase Equilibrium of Binary Mixture for the (propylene oxide + 1-pentanol) System at Several Temperatures

  • Kim, Jeong-lae;Kim, Hakmin;Park, Su In;An, Gyu Min;Kim, Min Gi;Shin, Moon Sam
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.73-77
    • /
    • 2019
  • Isothermal (vapor + liquid) equilibrium data measurements were undertaken for the binary mixtures of (propylene oxide + 1-pentanol) system at three different temperatures (303.15, 318.15, and 333.15) K. The Peng-Robinson-Stryjek-Vera equation of state (PRSV EOS) was used to correlate the experimental data. The van der Waals one-fluid mixing rule was used for the vapor phase and the Wong-Sandler mixing rule, which incorporates the non-random two liquid (NRTL) model, the universal quasi-chemical (UNIQUAC) model and the Wilson model, was used for the liquid phase. The experimental data were in good agreement with the correlation results.

Measurement of Flash Point for Binary Mixtures of Toluene, Methylcyclohexane, n-heptane and Ethylbenzene at 101.3 kPa (Toluene, Methylcyclohexane, n-heptane 그리고 Ethylbenzene 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.19-24
    • /
    • 2017
  • Flammable substances are used in laboratories and industrial process. The flash point (FP) is one of the most important physical properties used to determine the potential for characterizing the fire and explosion hazard of liquids. The FP data at 101.3 kPa were measured for the binary systems {toluene+ethylbenzene}, {methlycyclohenxane+ethylbenzene} and {n-heptane+ ethylbenzene}. The experiments were performed according to the standard test method (ASTM D 3278) using a SETA closed cup flash point tester. The measured FPs were compared with the values predicted using the following activity coefficient models: Wilson, Non-Random Two Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC). The average absolute deviation between the predicted and measured lower FP was less than 1.74 K.

Wall Heat Flux Behavior of Nucleate Pool Boiling Under a Constant Temperature Condition in a Binary Mixture System (일정 벽면 온도 조건에서 이성분 혼합물의 핵비등시 벽면 열유속 거동)

  • Bae, Sung-Won;Lee, Han-Choon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1239-1246
    • /
    • 2000
  • The objective of this work is to measure space and time resolved wall heat fluxes during nucleate pool boiling of R113/R11 mixtures using a microscale heater array in conjunction with a high speed CCD. The microscale heater array is constructed using VLSI techniques, and consists of 96 serpentine platinum resistance heaters on a transparent quartz substrate. Electronic feedback circuits are used to keep the temperature of each heater at a specified temperature and the variation in heating power required to keep the temperature constant is measured. Heat flux data around an isolated bubble are obtained with triggered CCD images. CCD images are obtained at a rate of 1000frames/second. The heat transfer variation vs. time on the heaters directly around the nucleation site is plotted and correlated with images of the bubble obtainedby using the high speed CCD. For both of the mixture(R11/R113) and pure system(pure R11, pure R113), the wall heat fluxes are presented and compared to find out the qualitative difference between pure and binary mixture nucleate boiling.

STM Study of Self Assembled Monolayer Formed from Binary Mixtures of Substituted Alkyl Chains (치환된 알킬 사슬 혼합물의 자기조립 단분자막 구조지 STM 연구)

  • Son S.B.;Lee H.;Jeon I.C.;Hahn J.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • The molecular assembly of p-iodo-phenyl octadecyl ether (I-POE), p-iodo-phenyl docosyl ether (I-PDE) and a binary mixture of these two molecules on graphite has been studied using a scanning tunneling microscope. Each molecular system self-assembles on the graphite surface to form a stable monolayer with a head-to-tail configuration. For the binary system, the I-POE and I-PDE molecules do not mix on the surface, preferring instead to form isolated monolayer domains. Here, the I-POE molecules are preferentially adsorbed on the graphite surface, due to the effects of alkyl chain length and the functional group on the monolayer structure.

The Calculation and Measurement of Flash Point for Water+1-Propanol and Water+2-Propanol Using Closed Cup Aparatus (밀폐식 장치를 사용한 Water+1-Propanol 과 Water+2-Propanol의 인화점 측정과 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.190-197
    • /
    • 2016
  • Flash point is the one of the important properties for the safe handling of inflammable liquid solution. In this paper, flash points of binary liquid solutions, water+1-propanol and water+2-propanol, were been measured by using Seta flash closed cup aparatus. Flash point was estimated using regression analysis method. Flash points were also estimated by the method based on Raoul's law and the method optimizing the binary parameters of van Laar equation. Experimental results were compared with the calculated results. The regression analysis method is able to estimate the flash point fairly well for water+1-propanol and water+2-propanol mixture.

An Experimental Study of a Heat pipe with Binary Mixture Working Fluid for Solar Collector (2 성분 혼합물을 작동유체로 사용하는 태양열 집열기용 히트파이프의 실험적 연구)

  • Jung, Eui-Guk;Boo, Joon-Hong;Chung, Won-Bok
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.13-18
    • /
    • 2003
  • Heat pipes with binary mixture fabricated and tested for applications where condenser temperature is in a range of $10^{\circ}C$ to $130^{\circ}C$. The pipe materials 8.0 mm O.D. cupper tube and the working fluids are ethanol-water mixtures. The total length of test of the heat pipe was 1710mm in which evaporator section was 1570mm, adiabatic section was 50mm and condenser section was 90mm. Mixing ratios of ethanol and water could be variable in mole fraction. Temperature of condenser section was $10^{\circ}C$, $80^{\circ}C$ and $130^{\circ}C$. Heat pipe performance experimental study was accomplished with change of mixing ratio in these temperatures. The fill charge ratio was 20% of the heat pipe volume. Wick structure was woven-wire and method of experimental work was that thermal load was increased 20W step until the heat pipe wall temperature reached at $150^{\circ}C$. Results were following: At coolant $10^{\circ}C$ and $130^{\circ}C$, mixing ratio that have beat thermal performance was 0.8M+ and at coolant $80^{\circ}C$, was 0.3 ${\sim}$ 0.5 M+.

  • PDF

Measurement of Flash Point for Binary Mixtures of Methanol, Ethanol, 1-propanol and Toluene (Methanol, Ethanol, 1-propanol 그리고 Toluene 이성분 혼합계에 대한 인화점 측정)

  • Hwang, In Chan;Kim, Seon Woo;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The flash point is one of the most important parameters used to characterize the ignition and explosion hazards of liquids. Flash points were measured for several binary systems containing toluene, including {methanol+toluene}, {ethanol+toluene}, and {1-propanol+toluene}. Experiments were performed according to the standard test method using a SETA closed cup flash point tester. The measured flash points were compared with the predicted values calculated using the following $G^E$ models: Wilson, NRTL, and UNIQUAC. The average absolute deviation between the predicted and measured lower flash point was less than 1.69 K.

Morphology Effect on Electrocatalytic Activity of TiO2 Spheres Synthesized by Binary Ionic Liquids in Water Electrolysis

  • Hong, Ki-Won;Pak, Dae-Won;Yoo, Kye-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1829-1833
    • /
    • 2012
  • Titania spheres were synthesized using binary ionic liquids to examine the electrocatalytic activity in acid solution. The morphology of $TiO_2$ particles was significantly different with the composition of ionic liquids. Among the binary ionic liquids, four set of mixtures led to the formation of $TiO_2$ sphere with various sizes. The morphology and structure of $TiO_2$ particles were characterized by XRD, $N_2$ physisoption and SEM analysis. All samples possessed an anatase phase after calcinations at $500^{\circ}C$. The structural properties of the samples were varied significantly with the morphology. In cyclic voltammograms, the morphology of $TiO_2$ spheres affected the electrocatalytic activity in water electrolysis. Among the samples, [Omim][$BF_4$]+[Hmim][$BF_4$] was the most effective ionic liquid to synthesize $TiO_2$ sphere with optimum morphology showing the highest electocatalytic performance.

Fire resistance of hybrid fiber reinforced SCC: Effect of use of polyvinyl-alcohol or polypropylene with single and binary steel fiber

  • Kazim Turk;Ceren Kina;Esma Balalan
    • Advances in concrete construction
    • /
    • v.16 no.1
    • /
    • pp.1-20
    • /
    • 2023
  • This study presents the experimental results performed to evaluate the effects of Polyvinyl-alcohol (PVA) and Polypropylene (PP) fibers on the fresh and residual mechanical properties of the hybrid fiber reinforced SCC before and after the exposure of 250℃, 500℃ and 750℃ temperatures. The compressive and splitting tensile strength, modulus of rupture (MOR), ultrasonic pulse velocity (UPV) as well as toughness and weight loss were investigated at different temperatures. PVA and PP fibers were added into SCC mixtures having only macro steel fiber and also having binary hybridization of both macro and micro steel fiber. The results showed that the use of micro steel fiber replaced by macro steel fiber improved the fresh and hardened properties compared to the use of only macro steel fiber. Moreover, it was emphasized that PVA or PP enhanced the residual flexural performance of SCC, generally, while it negatively influenced the workability, weight loss, UPV and the residual strengths with regards to the use of single steel fiber and binary steel fiber hybridization. Compared to the effect of synthetic fibers, PP had slightly more positive effect in the view of workability while PVA enhanced the residual mechanical properties more.