• Title/Summary/Keyword: Big-M Method

Search Result 195, Processing Time 0.031 seconds

A Method for Estimating Fluid Force in Proportional Directional Control Valves with Spool (스풀형 비례 방향/유량제어밸브의 유체력 검증법)

  • Lee, I.Y.;Son, J.M.;Shin, H.B.;Son, J.H.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.109-115
    • /
    • 2010
  • In establishing a simulation program for hydraulic valves, it is always a big obstacle to incorporate correctly flow forces on valve body into the simulation program. This paper suggests a method to estimate flow forces on spool in proportional directional/flow control valves with spool structure. Furthermore, suggests a way to obtain simulation program for spool valves, in which flow force mechanism is fully reflected.

  • PDF

Effect of Flue Gas Heat Recovery on Plume Formation and Dispersion

  • Wu, Shi Chang;Jo, Young Min;Park, Young Koo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.161-172
    • /
    • 2012
  • Three-dimensional numerical simulation using a computational fluid dynamics (CFD) was carried out in order to investigate the formation and dispersion of the plume discharged from the stack of a thermal power station. The simulation was based on the standard ${\kappa}{\sim}{\varepsilon}$ turbulence model and a finite-volume method. Warm and moist exhaust from a power plant stack forms a visible plume as entering the cold ambient air. In the simulation, moisture content, emission velocity and temperature of the flue gas, air temperature and wind speed were dealt with the main parameters to analyze the properties of the plume composed mainly of water vapor. As a result of the simulation, the plume could be more apparent in cold winter due to a big difference of latent heat capacity. At no wind condition, the white plume rises 120 m upward from the top of the stack, and expands to 40 m around from the stack in cold winter after flue gas heat recovery. The influencing distance of relative humidity will be about 100 m to 400 m downstream from the stack with a cross wind effect. The decrease of flue gas temperature by heat recovery of thermal energy facilitates the formation of the plume and restrains its dispersion. Wind speed with vertical distribution affects the plume dispersion as well as the density.

Biological Activities and Metabolite Analysis of Various Extracts and Fractions from Red Ginseng Marc

  • Lee, Dong Gyu;Jang, Ik Soon;Kang, Young-Hwa
    • Korean Journal of Plant Resources
    • /
    • v.33 no.6
    • /
    • pp.597-603
    • /
    • 2020
  • Red ginseng marc (RGM) has been used on primary industries using fertilizer or forage, and it mostly has been dumped. To improve utilization of RGM, the biological activities of RGM were examined. RGM was extracted and fractionated using various solvents and their biological activities were compared. The hexane fraction from the methanol extract of RGM (RGMMH) showed strong anti-cancer activity (58.56 ± 6.04% at 100 ㎍/mL) and anti-inflammatory effect (65.72 ± 1.33% at 100 ㎍/mL). But, oil extract of RGM extracted with hexane (RGMH) showed low activities (anti-cancer: 16.42 ± 3.33%, at 100 ㎍/mL, anti-inflammatory activity: 29.46 ± 2.10%, at 100 ㎍/mL). Their metabolites were analyzed using HPLC. Panaxydol known as anti-cancer compound of RGM was one of major compounds in RGMMH. Meanwhile, panaxydol was detected in trace amount in red ginseng marc oil (RGMH). In addition, RGMMH and RGMH showed big differences in HPLC profiling. This research suggests optimal extraction method of RGM oil.

A Study on the Comparison of Real Time GNSS Satellite Surveying Methods (실시간 GNSS 위성측량기법의 비교연구)

  • Lee, Yong-Chang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4D
    • /
    • pp.579-586
    • /
    • 2008
  • In this study, it was evaluated that the 3D tracking accuracy of basketball zone track line by real time GNSS satellite positioning methods which are VRS (Virtual Reference System), DGPS (Marine Differential GPS) and PP (Point Positioning) methods. The results of comparison between three methods over horizontal track of basketball zone, VRS, DGPS and PP methods showed ${\pm}$ several cm, ${\pm}$ m, and ${\pm}$ 2m horizontal position accuracy compared with real size respectively. And also, the grade and height deviation of the checking points on basketball zone by VRS method is very similar to the real grade and height, but results by DGPS and PP methods showed big variation and deviation in each case. We expected that VRS method using GNSS reference network will be a very useful tool compared with single based RTK method in real time accurate positioning such as precision construction fields, especially.

A Study on the Construction Method of the Songsanri Tombs Using Geophysical Exploration Method (송산리 고분군의 지구물리학적 조사를 통한 고분축조방법 고찰)

  • Suh, Mancheol;Lee, Changwhan;Jeong, Gyeok;Kim, Donghyun
    • Journal of Conservation Science
    • /
    • v.6 no.1 s.7
    • /
    • pp.61-70
    • /
    • 1997
  • An integrated geophysical survey was conducted to study a construction method of the Sonsanri tombs including the Muryong royal tomb. With the distribution of soil resistivity and self potential values, the boundary between original ground and the construction site was delineated clearly. The original ground has relatively high resistivity of $1,000\~1,500$ ohm-m and low self-potential values of $0{\pm}3mV/m$, while the construction site has low resistivity less than 200 ohm-m and quite high self-potential values of $-20\~30mV/m$. It is interpreted that the open site for construction of subsurface tomb has the size of about 35 m in the north-south direction. Big difference in characteristics of ground between the tomb site and the original site gives a clue for the construction method of tombs in Baekje dynasty. The site was opened about 35 meters in the north-south direction and then a mold structure was constructed with a brick frame outside. The brick frame consists of bricks cemented each other and structually combined. The mold structure was removed from inside after refill of the opened construction site with some cemented rock debris and soil.

  • PDF

Obervation of Langmuir Films Using Displacement Current Method and BAM (Brewster-Angle Microscope) (변위전류법과 BAM(BREWSTER-ANGLE MICROSCOPE)를 이용한 LANGMUIR막의 관찰)

  • Song, Kyung-Ho;Park, Tae-Gone;Park, Keun-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.38-42
    • /
    • 2001
  • To observe the Langmuir films, displacement current measuring system(Nippon Laser & Electronics), $\pi-A$ isotherms measuring device, and Brewster Angle Microscope(BAM) were used. As results, for 8A5H, big tilt angle changes of many molecules were detected before liquid expanded phase when the monolayer was compressed and expanded by barrier. Also many small and bright points were detected by BAM when the displacement current radically changed. In $\pi$-A isotherms, surface pressure of 8A5H was radically decreased between 35 and 40[mN/m] and monolayer was assumed to be collapsed in solid condensed phase, since large bright domain was observed without change of displacement current and this bright boundary was not classified part of domain in BAM image. If we observe behaviors of molecules on the water surface in these three measurement at the same time, we can get more precise informations on L films and it could be good data for fabricating LB films.

  • PDF

A Numerical Study on the NATM Tunnel Reinforcement using Centrifuge Model Experimental value (실험값을 이용한 NATM 터널의 보강효과에 관한 수치 해석적 연구)

  • Huh, Kyung-Han;Kim, Nak-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.2 s.13
    • /
    • pp.13-18
    • /
    • 2004
  • In this study, in the first place, parameters primarily influencing displacement and stress were constructed by using the Finite Difference Method; then using those parameters, the result of crown displacement and convergence among the existing, experimental values of a centrifuge model were compared with the result of numerical analysis; and then considering the stress and time effect of lining installation, parameters according to the difference of stiffness were studied. In the result of this study, it found out that rough, ground reinforcement effect manifests itself when reinforcement propert of the grouting of the big scale steel pipe through 3-D analysis is E= 4,000tf/m2 which of the stiffness of the original ground.

Characterization of Sprays used Ultrasonic Vibrant Plate with the Surface roughness (초음파 진동판의 표면조도에 따른 분무특성에 관한 연구)

  • Lee, Jun-Baek;Jeon, In-Kon;Jeon, Heung-Shin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.732-737
    • /
    • 2000
  • The purpose of this study is to compare the SMD(Sauter mean diameter) with different vibrant plates. Each vibrant plates have different surface roughness. Also liquid film thickness are measured for explanation how to concern atomization. Ultrasonic waves is used for vibration. Immersion liquid method is used for the measure of SMD and also liquid film thickness is measured using of point needle method. Distilled water and gasoline fuel are used to liquids. Supplied liquid flow rates are $18{\sim}296cc/min$. Centerline average roughness of vibrant plates are 0.5, 2.0, 4.7, $9.5\;{\mu}m$ and diameter of vibrant plate is 60mm. In result, good atomization of liquid is obtained in widen flow rates. The mean droplet size is increased in orders of 4.7, 2.0. 9.5, $0.5\;{\mu}m$ surface roughness. Distilled water has a big mean droplet size than gasoline fuel in low flow rate. Above the 78cc/min flow rates, distilled water has a small mean droplet size than gasoline fuel. Liquid films changes are measured with ultrasonic power. Also, cavitation effect on sprays is observed.

  • PDF

Runout Control of Mgenetically Suspended Grinding Spindle - Experimental Analysis of Adaptive LMS Feedforward Control Method - (자기베어링으로 지지된 연삭 스핀들의 런아웃 제어 -LMS Feedforward 제어를 이용한 실험적 해석-)

  • 노승국;경진호;박종권;최언돈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.997-1001
    • /
    • 2000
  • In this paper, the case studies of reducing rotational errors is theoretically done for a grinding spindle with an active magnetic bearing system. The rotational errors acting on the magnetic bearing spindle are due to mass unbalance of rotor, runout, grinding excitation and unmodeled nonlinear dynamics of electromagnets. For the most case, the electrical runout of sensor target is big even in well finished surface, this runout can cause a rotation error amplified by feedback control system. The adaptiveed forward method based on LMS algorithm is discussed to compensate this kind of runout effects, and investigated its effectiveness by numerical simulation and experimental analysis. The electrical runout form the rear sensor target of grind spindle is about 70$\mu\textrm{m}$ with harmonic frequencies. The rotor orbit size in rear bearing is reduced about to 5$\mu\textrm{m}$ due to 1X and 2X rejection by feedforward control.

  • PDF

Existing Building Energy Simulation Method Using Calibrated Model by Energy Audit Data (성능진단 데이터로 보정된 모델을 이용한 기존건축물의 에너지시뮬레이션 기법)

  • Kong, Dong-Seok;Kim, Du-Hwan;Chang, Yong-Sung;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.231-239
    • /
    • 2014
  • This paper represents a method of existing building energy simulation using energy audit data. Energy audit must be carried out for reasonable analysis, because characteristics of existing buildings such as efficiency of fan, pump, flow rate, pressure, COP and operating schedule could be changed during the building operation. These building characteristics should be measured to estimate actual energy consumption of the existing building. In this study, we conducted energy audit and calculated energy savings for a 7-stories building as a case-study. The energy audit data were used to calibrate the building model of EnergyPlus simulation. Baseline model validated according to M&V guideline index. As a result, building characteristics are significant parameters making a big impact on energy savings in existing buildings.