• 제목/요약/키워드: Bidirectional modulation

검색결과 53건 처리시간 0.021초

비용절감형 컨버터 구조를 갖는 3상-3상 PWM 정류기/인버터 시스템 (Novel Converter Topology for a Three Phase to Three Phase PWM Rectifier/Inverter System)

  • 김기택;박태열;이해춘
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.323-328
    • /
    • 1998
  • A current controlled VSI-PWM rectifier and inverter with capacitor dc link is regarded as one of the most promising structures for three-phase to three-phase to three-phase power conversion. This type of converter normally requires twelve switches for a rectifier and inverter composed of self turn-off switch such as a bi-polar transistor or IGBT with an anti-parallel diode. In this paper, a new three-phase to three-phase converter for ac motor drives is proposed. The proposed converter employs only eight switches and has the capability of delivering sinusoidal input currents with unity power factor and bidirectional power flow. This paper describes the feasibility and the operational limitations of the proposed structure. A mathematical model of the system is derived using generalized modulation theory and experimental results for steady state and dynamic behavior are presented to verify the developed model.

  • PDF

PWM 방식에 따른 계통연계 양방향 인버터 특성 비교 및 분석 (Analysis and Comparison of Grid-connected Bidirectional Inverter with Different Types of PWM Schemes)

  • 허성준;안효민;변종은;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.124-125
    • /
    • 2017
  • 본 논문은 ESS용 3상 계통연계 양방향 인버터에 적용 가능한 PWM (Pulse width modulation) 방식에 따른 계통전류 품질 특성 및 손실 양상에 대해 다룬다. 각 PWM 방식이 적용된 ESS용 3상 계통연계 양방향 인버터의 부하 크기 및 배터리 충 방전 모드 조건에 따른 계통전류 품질과 손실 양상을 비교 분석을 한다.

  • PDF

ZVT 인터리브드 양방향 LDC의 순환전류 손실 저감을 위한 스위칭 주파수 변조 기법 (Switching Frequency Modulation Method for Reduction of Circulating Current Loss in ZVT Interleaved Bidirectional LDC)

  • 박윤지;이순령;이종영;정원상;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.250-251
    • /
    • 2017
  • 본 논문에서는 ZVT 인터리브드 양방향 LDC의 순환전류 손실 저감을 위한 스위칭 주파수 변조 기법을 제안하였다. 제안된 컨버터 회로는 ZVT 동작을 수행하기 위해 보조 인덕터 전류가 부하 전류보다 커야하는 조건이 필요하다. 하지만 부하전류 변화에도 불구하고 보조 인덕터 순환전류는 변하지 않고 같은 값을 유지하는 문제점이 있다. 따라서 부하 전류가 감소함에 따라 도통 손실이 발생하여 컨버터의 효율이 감소한다. 이러한 문제점을 해결하기 위해 부하 전류와 시비율에 따른 최적의 주파수 값을 적용하여 보조 인덕터 순환 전류의 크기를 변화시켰다. 따라서 도통 손실을 저감시켰고 컨버터의 전반적인 효율이 증가함을 확인하였다. 본 논문에서 제안된 기법은 실험을 통해 검증되었다.

  • PDF

Stunting and Gut Microbiota: A Literature Review

  • Jessy Hardjo;Nathasha Brigitta Selene
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제27권3호
    • /
    • pp.137-145
    • /
    • 2024
  • Stunting, a condition characterized by impaired growth and development in children, remains a major public health concern worldwide. Over the past decade, emerging evidence has shed light on the potential role of gut microbiota modulation in stunting. Gut microbiota dysbiosis has been linked to impaired nutrient absorption, chronic inflammation, altered short-chain fatty acid production, and perturbed hormonal and signaling pathways, all of which may hinder optimal growth in children. This review aims to provide a comprehensive analysis of existing research exploring the bidirectional relationship between stunting and the gut microbiota. Although stunting can alter the gut microbial community, microbiota dysbiosis may exacerbate it, forming a vicious cycle that sustains the condition. The need for effective preventive and therapeutic strategies targeting the gut microbiota to combat stunting is also discussed. Nutritional interventions, probiotics, and prebiotics are among the most promising approaches to modulate the gut microbiota and potentially ameliorate stunting outcomes. Ultimately, a better understanding of the gut microbiota-stunting nexus is vital for guiding evidence-based interventions that can improve the growth and development trajectory of children worldwide, making substantial strides toward reducing the burden of stunting in vulnerable populations.

맨체스터 부호로 코딩된 하향신호의 재변조를 이용한 비동기 2.5 Gbps / 622 Mbps 광가입자 망의 성능 분석 (Performance Analysis of Asynchronous 2.5 Gbps / 622Mbps Optical Subscriber Network with Manchester coded Downstream and NRZ upstream re-modulation)

  • 박상조;김봉규
    • 한국광학회지
    • /
    • 제20권3호
    • /
    • pp.143-147
    • /
    • 2009
  • 맨체스터 부호로 코딩된 하향신호의 재변조를 이용하여 가입자내에 광원을 필요로 하지 않고 파장 및 전력제어회로를 제거할 수 있어 가입자 장치를 단순화시킬 수 있고, 상하향 데이터간의 비동기가 가능한 비대칭 2.5 Gbps / 622 Mbps의 광가입자 망을 제안한다. 하향 데이터의 형태에 따른 재변조한 상향신호의 평균오차율을 이론적으로 분석하고, 매트랩을 이용한 시뮬레이션에 의해 그 효용성을 분석한다. 제안시스템에서 SNR의 변화에 따라 임계치를 최적치로 설정할 경우 고정된 종래의 광수신기에 비하여 평균오차율이 향상되고, 수신감도도 3 dB 향상된다. 따라서 하향신호의 재변조를 이용한 제안 시스템을 경제적이고 단순구조를 가지는 광가입자 장치에서 비동기 및 비대칭 쌍방향 데이터 전송에 유용한 방식임을 알 수 있다.

경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사 (MTF and wavefront error testing of large aperture optical system using unequal path interferometer)

  • 송종섭;조재흥;이윤우;송재봉;양호순;이인원
    • 한국광학회지
    • /
    • 제16권1호
    • /
    • pp.50-55
    • /
    • 2005
  • 기준광과 탐사광의 경로길이가 매우 크게 차이가 나는 경로길이 불일치 간섭계(unequal path interferometer)를 이용한 직경 300mm 카세그레인 형태의 인공위성 망원경과 같은 대구경 광학계의 변조전달함수(modulation transfer function : MTF)와 파면오차를 동시에 측정하는 방법을 제안하고 이를 실험적으로 확인하였다. 이러한 경로불일치 간섭계를 이용한 측정시스템에서 필요한 평행한 시준광을 만들기 위해서 쌍방향 층밀리기 간섭계를 사용하였으며, 파면오차를 측정하기 위해서 직경 400 mm인 비축 포물경을 사용하는 긴 광경로차의 대구경 피조우 간섭계를 사용하였다. 또한 회전하는 확산판을 이용하여 레이저 광을 부분가간섭광으로 바꿈으로써 피조우 간섭계의 파장으로부터 쉽게 MTF를 측정할 수 있었다.

High-Frequency Flyback Transformer Linked PWM Power Conditioner with An Active Switched Capacitor Snubber

  • Mun, Sang-Pil;Kim, Soo-Wook;Joo, Seok-Min;Park, Young-Jun
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.7-15
    • /
    • 2008
  • A single active capacitor snubber-assisted soft-switching sinewave pulse modulation utility-interactive power conditioner with a three-winding flyback high frequency transformer link and a bidirectional active power switch in its secondary side has been proposed. With the aid of the switched-capacitor quasi-resonant snubber cell, the high frequency switching devices in the primary side of the proposed DC-to-AC sinewave power inverter can be turned-off with ZVS commutation. In addition to this, the proposed power conditioner in the DCM can effectively take the advantages of ZCS turn-on commutation. Its output port is connected directly to the utility AC power source grid. At the end, the prototype of the proposed HF-UPC is built and tested in experiment. Its power conversion conditioning and processing circuit with a high frequency flyback transformer link is verified and the output sinewave current is qualified in accordance with the power quality guidelines of the utility AC interactive power systems.

Alteration of Gut Microbiota in Autism Spectrum Disorder: An Overview

  • Oh, Donghun;Cheon, Keun-Ah
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제31권3호
    • /
    • pp.131-145
    • /
    • 2020
  • The microbiota-gut-brain axis, which refers to the bidirectional communication pathway between gut bacteria and the central nervous system, has a profound effect on important brain processes, from the synthesis of neurotransmitters to the modulation of complex behaviors such as sociability and anxiety. Previous studies have revealed that the gut microbiota is potentially related to not only gastrointestinal disturbances, but also social impairment and repetitive behavior-core symptoms of autism spectrum disorder (ASD). Although studies have been conducted to characterize the microbial composition in patients with ASD, the results are heterogeneous. Nevertheless, it is clear that there is a difference in the composition of the gut microbiota between ASD and typically developed individuals, and animal studies have repeatedly suggested that the gut microbiota plays an important role in ASD pathophysiology. This possibility is supported by abnormalities in metabolites produced by the gut microbiota and the association between altered immune responses and the gut microbiota observed in ASD patients. Based on these findings, various attempts have been made to use the microbiota in ASD treatment. The results reported to date suggest that microbiota-based therapies may be effective for ASD, but largescale, well-designed studies are needed to confirm this.

DSP를 이용한 원격 진료용 송수신 단말기 설계 (The transceiver design for telemedicine using DSP)

  • 이종회;이주원;조원래;한석붕;이건기
    • 한국정보통신학회논문지
    • /
    • 제3권1호
    • /
    • pp.97-104
    • /
    • 1999
  • 본 연구는 외부에서 발생하는 응급 환자의 심전도 신호를 병원에서 신속 정확히 파악해 필요한 조치를 의사의 지시 하에 취할 수 있는 DSP를 이용한 원격 진료용 송ㆍ수신 단말기를 설계하였다. 이 송ㆍ수신 단말기는 심전도 계측 장비에서 얻어진 동적 데이터의 실시간 전송과 음성 신호의 쌍방향 통신을 위해 DSP를 이용하여 진폭 변ㆍ복조 방식의 일종인 DSB-SC 방식을 이용하여 설계하였고, 각 단말기의 필터는 HR 필터로 구현하였다. 본 연구에서 설계된 시스템은 DSP를 이용하였기 때문에 소형ㆍ경량화를 실현시킬 수 있었으며, 프로그램의 수정만으로 다양한 생체 신호에 적용 할 수 있다.

  • PDF

Reactive Power and Soft-Switching Capability Analysis of Dual-Active-Bridge DC-DC Converters with Dual-Phase-Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.18-30
    • /
    • 2015
  • This paper focuses on a systematical and in-depth analysis of the reactive power and soft-switching regions of Dual Active Bridge (DAB) converters with dual-phase-shift (DPS) control to achieve high efficiency in a wide operating range. The key features of the DPS operating modes are characterized and verified by analytical calculation and experimental tests. The mathematical expressions of the reactive power are derived and the reductions of the reactive power are illustrated with respect to a wide range of output power and voltage conversion ratios. The ZVS soft-switching boundary of the DPS is presented and one more leg with ZVS capability is achieved compared with the CPS control. With the selection of the optimal operating mode, the optimal phase-shift pair is determined by performance indices, which include the minimum peak or rms inductor current. All of the theoretical analysis and optimizations are verified by experimental tests. The experimental results with the DPS demonstrate the efficiency improvement for different load conditions and voltage conversion ratios.