• 제목/요약/키워드: Bidirectional Device

검색결과 65건 처리시간 0.028초

3상 전압형 PWM 컨버터의 특성개선에 관한 연구 (A Study On The Characteristic Improvement of 3 Phase Voltage Source PWM Converter)

  • 정연택;김원철;전지용;김현우;이근홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.830-832
    • /
    • 1993
  • In this paper, A voltage source PWM converter which achieves bidirectional power flow between a $3{\phi}$ AC supply and a DC bus voltage is described. And the paper considers both the steady state and transient response of such a device, and develops mathematical models to describe its performance under the digital control system. As a result the AC line current becomes sinusoidal and the input power factor is improved to unity.

  • PDF

마이크로그리드 실증사이트의 보호협조 전략 (Protection Coordination Strategy of Microgrid Demonstration Site)

  • 진대근;최원준;원동준;이학주;채우규;박중성
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.966-973
    • /
    • 2012
  • In microgrid demonstration site, distributed generations can make bidirectional power flows on the system. If an accident occurs, the fault current from the inverter based distributed generation is small. However, the conventional protection scheme in distribution network is designed to operate at high fault current. This means that the traditional protection of distribution network is no longer applicable and new protection methods must be developed. In this paper, for two cases, algorithms for protection coordination of demonstration site is proposed and verified through PSCAD/EMTDC simulation. In first case, protection devices are assumed to have the abilities of directional relaying and communication. In second case, protection devices do not have those abilities. Proposed protection coordination algorithms detect the fault locations and protect the microgrid fairly well.

양방향 압전-유압 하이브리드 구동장치의 성능 시험 (Performance Evaluation of a Bidirectional Piezoelectric Hybrid Actuator)

  • 김소룡;하넉산;구남서;배병운;김태흔;고한서;이창섭
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.213-219
    • /
    • 2015
  • Piezoelectric-based hydraulic actuator is a hybrid device consisting of a hydraulic pump driven by piezoelectric stacks that is coupled to a conventional hydraulic cylinder via a set of fast-acting valves. Nowadays, such hybrid actuators are being researched and developed actively in many developed countries by requirement of high performance and compact flight system. In this research, a piezoelectric hybrid actuator has been designed and tested. To achieve bi-directional capabilities in the actuator, solenoid valves were used to control the direction of output fluid. The experimental testing of the actuator in uni-directional and bi-directional modes was performed to examine performance issues related to the solenoid valves. The results showed that the bi-directional performance was slightly lower than uni-directional performance due to air bubble developed in the valve system. A new design to solve the vacuum problem has been proposed to improve the performance of the hybrid actuator.

직류 전원선을 이용한 다중 접속 양방향 직렬통신 프로토콜 구현 (Implementation of multiple access bidirectional serial communications protocol using DC power line)

  • 한경호;김원일;황하윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.332-338
    • /
    • 2008
  • This paper handles, implementation of multiple access bidirectional serial communications protocol using two common DC power lines, whict are power supply and ground, connecting multiple devices. Communication between the host and the multiple clients are performed using unique packet data with device ID unique to each devices connected on the common power lines. Host initiates data communications by transmitting command packet to the designated client with the client's ID and the client responds by transmitting response packet to the host and in this way, multiple clients and host exchange the packet through the common power lines. The normal voltage of the power communication line maintains 24V corresponding to level 1 and the host drops the voltage to 12V on sending level 0 signal, also the clients normally keeps the line voltage to 24V use pull-down circuit to drop the voltage to 12V on sending level 1 signal. Power supply originates from the host, the host senses the voltage level of the power communication lines and when the clients activates pull down circuit to send level 0 signal and the voltage drops to 12V, the hosts switches power source from 24V to 12V. Also, when clients deactivate pull down circuit to send level 1 signal, the host senses the voltage increase and switches the power source from 12V to 24V. Experimental circuit is designed with one hosts and four clients and verified the power line voltage switching operation depending on the data signal levels on the power line. The proposed research result can be applied to two wire power communications system with one host and multiple low current consumption clients.

  • PDF

높은 홀딩 전압으로 인한 래치업 면역을 갖는 양방향 구조의 ESD 보호회로에 관한 연구 (A Study on ESD Protection Circuit with Bidirectional Structure with Latch-up Immunity due to High Holding Voltage)

  • 정장한;도경일;진승후;고경진;구용서
    • 전기전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.376-380
    • /
    • 2021
  • 본 논문에서는 일반적인 SCR의 구조를 개선하여 높은 홀딩 전압으로 인한 래치 업면역 특성을 가지는 새로운 ESD 보호회로를 제안한다. 제안된 ESD회로의 특성검증을 위하여 Synopsys사의 TCAD를 이용하여 시뮬레이션을 진행하였으며, 기존 ESD 보호회로와 비교하여 제시하였다. 또한 설계변수 D1을 이용하여 전기적 특성의 변화를 검증하였다. 시뮬레이션 수행 결과 제안된 ESD 보호회로는 기존의 ESD 보호회로에 비해 높은 홀딩 전압특성과 양방향 방전특성을 확인하였다. 또한, Samsung의 0.13um BCD 공정을 이용하여 설계 후 TLP 측정을 통해 전기적 특성을 검증하였다. 이러한 과정을 통해 본 논문에서 제안된 ESD 보호회로 설계변수의 최적화를 진행하였고 향상된 홀딩 전압으로 래치 업 면역을 갖는다는 점에서 고전압 어플리케이션에 적용하기에 매우 적합함을 검증하였다.

냉각 송풍장치를 이용한 기능성 농약방제복의 구성시안 제안에 관한 연구 (A Draft Proposal for Functional Pesticide Protection Clothing Using a Cooling Blower Unit)

  • 오영순;이경숙;채혜선;김경란
    • 한국지역사회생활과학회지
    • /
    • 제25권4호
    • /
    • pp.557-566
    • /
    • 2014
  • This study examines he trend in the development of protective clothing for pesticide spraying based on materials with domestic patents and proposes pesticide protection clothing using a cooling blower unit effective for reducing heat stress in pesticide spraying. There was a total of 54 domestic patents on protective clothing related to pesticide spraying, reflecting a sharp increase based on the increasing demand for protective clothing since 2000. Protective clothing with a lower level of heat stress as the core technology accounted for 35.2% of these patents, and recent years have witnessed the increased development of protective clothing supplying cold air to the interior of the clothing through a separate device. However, this may cause some inconvenience in the activity of farmers. Therefore, this study proposes a lightweight cooling blower unit that does not hinder the user's appearance and activity. In the cooling blower unit, contaminated air from outside is purified through a filter and cools down as it passes a cooling device with refrigerant in the copper pipe. This chilled air is supplied to the interior of the clothing through a bidirectional inhaling blower. The proposed protective clothing is an overall with raglan sleeves. Its chill injection site has an area where the most conspicuous change in temperature is selected, and at the back, there is a large pocket for a cooling blower unit.

디스플레이용 판유리 이송을 위한 양방향 이송 로봇장치 (Full Duplex Robot System for Transferring Flat Panel Display Glass)

  • 이동훈;김성동;이치범;조영학
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.996-1002
    • /
    • 2013
  • This study addresses the development of a full duplex robotic system for transferring flat-panel display glass. We propose to accomplish this using a bidirectional linear transfer mechanism in place of the conventional rotary transfer mechanism. The developed full duplex robot comprises a driving part that carries the glass panel laterally, vertical part that can be moved up and down by means of a ball screw and linear motion guide arrangement, and hand part that slides by the cylinder of the driving part along the guide rail with a V-guide bearing attached to the bottom of the support. In addition, an alignment part prevents the hand part from derailing and holds the hand part while the driving part moves horizontally. The full duplex robot lifts and drives a glass panel directly while transferring it to the buffer and does not require rotational motion. Therefore, both transferring and stacking are realized with a single device. This device can be used in existing industrial facilities as an alternative to existing industrial robots in current as well as future process lines. The proposed full duplex robot is expected to save considerable amounts of time and space, and increase product throughput.

제한수신 기능을 통한 양방향 인증 T-DMB 시스템 (Limited Reception Function based Two-Way Authentication T-DMB System)

  • 이종원;박상노;유대상;김종문;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.794-796
    • /
    • 2016
  • 최근 지상파 이동 멀티미디어방송(T-DMB)은 전국적으로 서비스가 확대되어 제공되고 있으며 나날이 수요가 증대되고 있다. T-DMB는 타 이동멀티미디어방송보다 설치비용 면에서 저렴하다는 장점이 있으나 다양한 데이터 및 국지적인 재난경보 방송 서비스의 추가 제공이 어렵다는 단점이 있다. 본 논문에서는 이러한 문제점을 해결하기 위한 방법으로 제한수신 기능을 통한 단방향/양방향 인증 T-DMB 시스템을 설계하였다. T-DMB 방송을 수신하여 모바일 디바이스로 재전송해주는 인증 메커니즘을 제공하고 이를 통해 등록된 사용자외의 T-DMB 수신이 불가능한 모바일 디바이스에서도 방송을 수신하여 시청할 수 있게 된다. 제안한 시스템을 이용하여 기존의 T-DMB 기술의 문제점을 해결할 수 있을 것으로 사료된다.

  • PDF

양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구 (A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication)

  • 이봉섭;곽동걸;정도영;천동진
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

Home Energy Management System for Interconnecting and Sensing of Electric Appliances

  • Cho, Wei-Ting;Lai, Chin-Feng;Huang, Yueh-Min;Lee, Wei-Tsong;Huang, Sing-Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권7호
    • /
    • pp.1274-1292
    • /
    • 2011
  • Due to the variety of household electric devices and different power consumption habits of consumers at present, general home energy management (HEM) systems suffer from the lack of dynamic identification of various household appliances and a unidirectional information display. This study presented a set of intelligent interconnection network systems for electric appliances, which can measure the power consumption of household appliances through a current sensing device based on OSGi platform. The system establishes the characteristics and categories of related electric appliances, and searches the corresponding cluster data and eliminates noise for recognition functionality and error detection mechanism of electric appliances by applying the clustering algorithm. The system also integrates household appliance control network services so as to control them according to users' power consumption plans or through mobile devices, thus realizing a bidirectional monitoring service. When the system detects an abnormal operating state, it can automatically shut off electric appliances to avoid accidents. In practical tests, the system reached a recognition rate of 95%, and could successfully control general household appliances through the ZigBee network.