• Title/Summary/Keyword: Biaxial strength

Search Result 191, Processing Time 0.025 seconds

A study on strength of steel square tubular columns filled with high strength concrete under biaxial eccentric load (2축휨을 받는 고강도콘크리트충전 각형강관기둥의 내력에 관한 연구)

  • Seo, Seong Yeon;Keigo, Tsuda;Atsushi, Nakamura
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.567-576
    • /
    • 2002
  • Maximum-strength concrete-ailed steel square tubular columns were tested under concentric and biaxial eccentric load. Buckling length-section depth ratio $L_k/D$, magnitude of eccentricity e, and angle of eccentric load ${\theta}$ were selected as experimental parameters. Strength and behavior were also examined. Test results showed that the maximum strength of columns under biaxial eccentric load could be predicted using the previously proposed strength formula of columns under uniaxial eccentric load. Likewise, the behavior and maximum strength of columns could be predicted using the analysis.

EFFECTS OF AGING AND THERMAL CYCLING ON THE BIAXIAL FLEXURE STRENGTH OF VENEERING RESIN COMPOSITES FOR CROWN (시효처리와 thermal cycling이 치관전장용 복합레진의 2축굽힘강도에 미치는 영향)

  • Jeong, Gwan-Ho;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.597-606
    • /
    • 1999
  • This study was performed to evaluate the effect of aging and thermal cycling on the biaxial flexure strength of low commercially available veneering resin composites for crown(Dentacolor : DC, Artglass : AG, Esternia : ET and Targis : TG). Disc specimens were fabricated in a teflon mold giving 12mm in diameter and 1mm in thickness. All samples were divided into 4 groups. Group 1 was dried in a dessicator at $25^{\circ}C$ for 30 days. Group 2 was immersed in distilled water at $37^{\circ}C$ for 30 days. Group 3 was immersed in distilled water at $65^{\circ}C$ for 30 days. Group 4 was subjected to 10,000 thermal cycles between $5^{\circ}C\;and\;55^{\circ}C$, and the immersion time in each bath was 15 seconds per cycle. Biaxial flexure test was conducted using the ball-on-three-ball method at the cross head speed of 0.5mm/min and fracture surfaces were observed with scanning electoron microscope. The results obtained were summarized as follows; 1. Weibull modulus values, except for the AG group, decreased after thermal cycling treatment. 2. Biaxial flexure strength values of aging group at $37^{\circ}C$ were the lowest in all sample groups. Except for the DC group, strength values were significantly decreased for the drying group. 3. After thermal cycling test, the highest value of biaxial flexure strength of 188.8 MPa was observed in the ET group and the lowest value of 73.2 MPa was observed in the DC group. The strength values showed the significant differences in each group (p<0.05). 4. Observation of surfaces after thermal cycling test revealed the ditching in the part of surrounding large fillers.

  • PDF

The Biaxial Flexure Test(BFT) method and its finite element analysis (이방향 휨인장 시험(Biaxial Flexure Test; BFT) 및 삼차원 유한요소 해석)

  • Kim, Ji-Hwan;Zi, Goang-Seup;Kang, Jin-Gu;Oh, Hong-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.693-696
    • /
    • 2008
  • The biaxial tensile strength of concretes was measured by the Biaxial Flexure Test(BFT) which was recently developed to measure the biaxial tensile strength of concretes. From the test result, The circular specimen is generally fractured after 1${\sim}$3 of the initial crack were formed on the top of specimen. The direction and number of the initial crack was completely arbitrary. As the specimen was larger, the number of the crack increased. And, the strengths of the different radii and thickness of specimens were calculated by the commercial finite element program to study the size effect of the biaxial tensile strength like the uniaxial tensile strength. The parameters such as radii to the support and to the load point, were studied using the program. The results of the FE analysis were entirely consistent with the predictive solution, when b/a>0.4, and the thickness of the specimens were increased. On the other hands, those with lesser free length showed good results.

  • PDF

Strength Evaluation of a Doubler Plate of a Ship S011c111re subjected to Biaxial In-plane Compression and Shear Load (양축방향 면내압축과 전단하중을 받는 선박 이중판의 강도 평가)

  • 함주혁
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.85-91
    • /
    • 2001
  • A study for the structural strength analysis on the doubler plate subjected biaxial in-plane compression and shear load has been performed through the systematic evaluation process. In order to estimate the proper static strength of the doubler plate, non-linear elasto-plastic analysis is introduced. Gap element modeling for contact effect between the main plate and the doubler is prepared and nonlinear analysis procedures are illustrated based on MSC/N4W. In addition, some design guides are suggested through the consideration of several important effects such as corrosion of main plate, doubler width, doubler length and doubler thickness. Finally, theses result are compared with a developed design formula based on the buckling strength and general trends. The design guides, according to the variation of design parameters are discussed.

  • PDF

Numerical investigation of The characteristics of Biaxial Flexure Specimens (수치해석을 이용한 이방향 휨인장 시험체의 특성분석)

  • Kim, Ji-Hwan;Zi, Goang-Seup;Kang, Jin-Gu;Oh, Hong-Seob
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.614-617
    • /
    • 2008
  • This paper presents the numerical investigation of the characteristics of biaxial flexure specimens for the Biaxial Flexure Test(BFT) which was recently developed to measure the biaxial tensile strength of concrete. Using FEM, the effect of size and eccentricity on the specimens was evaluated. The parameters such as radious of the support and the loadings, thickness and free length were studied. The results of the FE analysis were entirely consistent with the predictive solution, when b/agt;0.4, h/alt;0.6 and the thickness of the specimens were increased. On the other hands, when b/agt;0.4, those with lesser free length showed good results. To limit the difference between the stresses at the end points of 2b as the specimen was sustained and the stress at the center point of the specimen are not over 10%, lateral eccentricity was analyzed to be in the limits of 3%.

  • PDF

An Experimental Study in Rectangular High Strength Concrete Columns under Both Axial Load and Biaxial Bending (2축 편심 축하중을 받는 직사각형 고강도 RC기둥의 거동에 대한 실험적연구)

  • 이종원;조문희;한경돈;유석형;반병열;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.209-214
    • /
    • 2001
  • Most reinforce concrete Columns of Building structure are subjected to both axial load and biaxial bending. However, It is hard to estimate the moment capacity of biaxial bending by exact solution. Thus, columns under biaxial bending are designed by approximate methods in practice. The purpose of this study is to compare experimental result with approximate methods and exact solution by computer. Parameters of the present test are compressive strength of concrete (350, 585, 650kgf/$\textrm{cm}^2$) and shape ratio of rectangular section. Ultimately, an experimental shape factor for rectangular RC column section is obtained through the test program. The shape of load contour is dominated by this shape factor obtained experimentally. So, reasonable design of RC columns subjected to both axial compression and biaxial bending depends on load contour.

  • PDF

Influence of Biaxial Loads on Impact Fracture of High-Strength Membrane Materials

  • Kumazawa, Hisashi;Susuki, Ippei;Hasegawa, Osamu;Kasano, Hideaki
    • Advanced Composite Materials
    • /
    • v.18 no.4
    • /
    • pp.395-413
    • /
    • 2009
  • Impact tests on high-strength membrane materials under biaxial loads were experimentally conducted in order to evaluate influence of biaxial loads on impact fracture of the membrane materials for the inflated applications. Cruciform specimens of the membrane materials were fabricated for applying biaxial loadings during the impact test. A steel ball was shot using a compressed nitrogen gas gun, and struck the membrane specimen. Impact tests on uniaxial strip specimens were also conducted to obtain the effect of specimen configuration and boundary condition on the impact fracture. The results of the measured crack length and the ultra-high speed photographs indicate the impact fracture properties of the membrane fabrics under biaxial loadings. Crack length due to the impact increased with applied tensile load, and the impact damages of the cruciform membrane materials under biaxial loadings were smaller than those of under uniaxial loadings. Impact fracture of the strip specimen was more severe than that of the cruciform specimen due to the difference of boundary conditions.

Biaxial flexural strength and phase transformation of Ce-TZP/$Al_2O_3$ and Y-TZP core materials after thermocycling and mechanical loading

  • Gungor, Merve Bankoglu;Yilmaz, Handan;Aydin, Cemal;Nemli, Secil Karakoca;Bal, Bilge Turhan;Tiras, Tulay
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.224-232
    • /
    • 2014
  • PURPOSE. The purpose of the present study was to evaluate the effect of thermocycling and mechanical loading on the biaxial flexural strength and the phase transformation of one Ce-TZP/$Al_2O_3$ and two Y-TZP core materials. MATERIALS AND METHODS. Thirty disc-shaped specimens were obtained from each material. The specimens were randomly divided into three groups (control, thermocycled, and mechanically loaded). Thermocycling was subjected in distilled water for 10000 cycles. Mechanical loading was subjected with 200 N loads at a frequency of 2 Hz for 100000 times. The mean biaxial flexural strength and phase transformation of the specimens were tested. The Weibull modulus, characteristic strength, 10%, 5% and 1% probabilities of failure were calculated using the biaxial flexural strength data. RESULTS. The characteristic strengths of Ce-TZP/$Al_2O_3$ specimens were significantly higher in all groups compared with the other tested materials (P<.001). Statistical results of X-ray diffraction showed that thermocycling and mechanical loading did not affect the monoclinic phase content of the materials. According to Raman spectroscopy results, at the same point and the same material, mechanical loading significantly affected the phase fraction of all materials (P<.05). CONCLUSION. It was concluded that thermocycling and mechanical loading did not show negative effect on the mean biaxial strength of the tested materials.

Strength and ductility of biaxially loaded high strength RC short square columns wrapped with GFRP jackets

  • Hodhod, O.A.;Hassan, W.;Hilal, M.S.;Bahnasawy, H.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.6
    • /
    • pp.727-745
    • /
    • 2005
  • The present study is an experimental investigation into the behaviour of high strength concrete square short columns subjected to biaxial bending moments and strengthened by GFRP laminates. The main objectives of the study are: to evaluate the improvement in the structural performance of HSC short square columns subjected to small biaxial eccentricity when strengthened by externally applied FRP laminates, and to investigate the optimum arrangement and amount of FRP laminates to achieve potential enhancement in structural performance especially ductility. The parameters considered in this study are: number of FRP layers and arrangement of wraps. The load eccentricity is kept corresponding to e/t = 0.125 in two perpendicular directions to the columns principal axes, and the wraps are applied in single or double layers (partial or full wrapping). In the present work, test results of five full scale concrete columns are presented and discussed. The study has shown that FRP wraps can be used successfully to enhance the ductility of HSC columns subjected to biaxial bending by 300%.

MECHANICAL PROPERTIES OF REUSED LITHIUM DISILICATE GLASS-CERAMIC OF IPS EMPRESS 2 SYSTEM

  • Oh Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.6
    • /
    • pp.572-576
    • /
    • 2002
  • This investigation was designed to estimate the biaxial flexure strength and fracture toughness of lithium disilicate glass-ceramics of IPS Empress 2 system pressed with as-received ingots and their sprue buttons. Two groups of the lithium disilicate glass-ceramics were prepared as follows: group 1 is ingot-pressed group; group 2 is sprue button-pressed group. A ball-on-three-ball test was used to determine biaxial flexure strength (BFS) of disks in wet environment. Scanning electron microscopy(SEM) analysis was conducted to observe the microstructure of the ceramics. Unpaired t-test showed that there were no differences in the mean biaxial Hem strength (BFS) and KIC values between group 1 and 2 (p > 0.05). Two groups showed similar values in the KIC and the strength at 5% failure probability. The SEM micrographs of the IPS Empress 2 glass-ceramic showed a closely packed, multi-directionally interlocking pattern of numerous lithium disilicate crystals protruding from the glass matrix. The lithium orthophosphate crystals could not be observed on the fracture surface etched. There was no a marked difference of the microstructure between group 1 and 2. Although there were no tests including color stability, casting accuracy, etc., the results of this study implied that we could reuse the sprue button of the pressed lithium disilicate glass-ceramic of IPS Empress 2 system.