• 제목/요약/키워드: Bi-polar pulse

검색결과 7건 처리시간 0.019초

반도체 스위치를 이용한 양방향 고압 펄스 발생기 (Bi-polar High-voltage Pulse Generator Using Semiconductor switches)

  • 김종현;류명효;정인화;;김종수;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.291-293
    • /
    • 2003
  • A semiconductor switch-based fast hi-polar high voltage pulse generator is proposed in this paper The proposed pulse system is made of a thyristor based-rectifier, DC link capacitor, a push-pull resonant inverter, a high voltage transformer. secondary capacitor, a high voltage IGBT & diode stacks, and a variable capacitor. The proposed system makes hi-polar high voltage sinusoidal waveform using resonance between leakage inductance of the transformer and secondary capacitor and transfers energy to output load at maximum of the secondary capacitor voltage. Compared to previous hi-polar high voltage pulse power supply using nonlinear transmission line, the proposed pulse power system using only semiconductor switches has simple structure and gives high efficiency

  • PDF

Observations of Pulsed Bi-polar Discharges in Saline Solutions with Pin to Plate Electrodes

  • Shin, Bhum Jae;Seo, Jeong-Hyun;Collins, George J.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2011-2016
    • /
    • 2018
  • In this study, we have been investigated pin to plate pulsed bi-polar discharges in saline solutions, where bubble generation occurs. We integrate basic I-V-t electrical characteristics with the ICCD shadowgraph images, and finally instant and time averaged I-V waveforms. We observed that the bubble formation phase dynamics is quite different corresponding to the polarity applied to the pin electrode. When the pin electrode is a cathode, the bubble tends to be periodically detached from the pin electrode and the numerous tiny voltage spikes occur related to the electron emission from a pin cathode casing via, we judge from, direct dissociation of water molecules by energetic electrons. On the contrary, the bubble tends to stick to the pin electrode, when the pin electrode is anode; the bubble grows in size throughout the pulse duration. The dynamic electrical characteristics relative to the applied polarity of a pin electrode are presented and discussed by analysis of time averaged I-V waveforms.

안정된 PWM 제어 DC/DC 전력 강압 컨버터 구현 (Implementation of DC/DC Power Buck Converter Controlled by Stable PWM)

  • 노영환
    • 제어로봇시스템학회논문지
    • /
    • 제18권4호
    • /
    • pp.371-374
    • /
    • 2012
  • DC/DC switching power converters produce DC output voltages from different stable DC input sources regulated by a bi-polar transistor. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The voltage mode DC/DC converter is composed of a PWM (Pulse Width Modulation) controller, a MOSFET (Metal Oxide Semiconductor Field Effect Transistor), an inductor, and capacitors, etc. PWM is applied to control and regulate the total output voltage. It is shown that the output of DC/DC converter depends on the variation of threshold voltage at MOSFET and the variation of pulse width. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by SPICE (Simulation Program with Integrated Circuit Emphasis) and experiments.

Development of High Flux Metal Ion Plasma Source for the Ion Implantation and Deposition

  • Kim, Do-Yun;Lee, Eui-Wan
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.45-56
    • /
    • 2003
  • A high flux metal plasma pulse ion source, which can simultaneously perform ion implantation and deposition, was developed and tested to evaluate its performance using the prototype. Flux of ion source was measured to be 5 A and bi-polar pulse power supply with a peak voltage of 250 V, repetition of 20 Hz and width of 100 ${\mu}\textrm{s}$ has an output current of 2 kA and average power of 2 kW. Trigger power supply is a high voltage pulse generator producing a peak voltage of 12 kV, peak current of 50 A and repetition rate of 20 Hz. The acceleration column for providing target energy up to ion implantation is carefully designed and compatible with UHV (ultra high vacuum) application. Prototype systems including various ion sources are fabricated for the performance test in the vacuum and evaluated to be more competitive than the existing equipments through repeated deposition experiments.

  • PDF

CNT를 이용한 무수은 면광원 안정기 개발 (The Ballast for Field Emission Lamp with CNT Emitter)

  • 박동혁;하석진;정혜만;김종현;백주원;유동욱;송의호
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.31-37
    • /
    • 2009
  • 본 논문에서는 전계방출 원리를 이용하여 이미터로서의 성능이 뛰어난 탄소나노튜브 (Carbon Nano Tube)를 이용한 전계방출 면광원용 안정기를 제안한다. 안정기는 고전압 직류전압 부분과 양극의 펄스를 생성하는 부분으로 구성되어 있다. 탄소나노튜브를 이용한 전계방출 램프는 3가지의 전극 (애노드, 게이트, 캐소드)으로 구성되어 있는데, 애노드와 게이트 사이에는 직류 고전압이 공급되고 게이트와 캐소드 사이에는 양극의 펄스가 공급된다. 램프 및 안정기를 보호하기 위하여 과전류, 과전압, 과온도에 대한 보호 기능을 추가하였고, 실험을 통하여 제안된 방식이 탄소나노튜브를 이용한 램프 구동을 위한 적합함을 검증하였다.

Improved Current Source Design to Measure Induced Magnetic Flux Density Distributions in MREIT

  • Oh Tong-In;Cho Young;Hwang Yeon-Kyung;Oh Suk-Hoon;Woo Eung-Je;Lee Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권1호
    • /
    • pp.30-37
    • /
    • 2006
  • Injecting currents into an electrically conducting subject, we may measure the induced magnetic flux density distributions using an MRI scanner. The measured data are utilized to reconstruct cross-sectional images of internal conductivity and current density distributions in Magnetic Resonance Electrical Impedance Tomography (MREIT). Injection currents are usually provided in a form of mono-polar or bi-polar pulses synchronized with an MR pulse sequence. Given an MRI scanner performing the MR phase imaging to extract the induced magnetic flux density data, the current source becomes one of the key parts determining the signal-to-noise ratio (SNR) of the measured data. Since this SNR is crucial in determining the quality of reconstructed MREIT images, special care must be given in the design and implementation of the current source. This paper describes a current source design for MREIT with features including interleaved current injection, arbitrary current waveform, electrode switching to discharge any stored charge from previous current injections, optical isolation from an MR spectrometer and PC, precise current injection timing control synchronized with any MR pulse sequence, and versatile PC control program. The performance of the current source was verified using a 3T MRI scanner and saline phantoms.

CNT 전계방출용 펄스전원장치 개발에 관한 연구 (A study on the development of pulse generator system for CNT field emission)

  • 김정훈;정혜만;류명효;김종현;유동욱;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.166-168
    • /
    • 2005
  • 본 논문에서는 고효율 고휘도의 신광원을 개발함에 있어, 전계방출(Field Emission) 원리를 이용하여, 이미터로서의 성능이 입증된 CNT(Carbon Nanotube, 탄소나노튜브)를 이용한 평판 형태의 신개념 램프에 대한 펄스전원장치에 대한 연구를 하였다. 특히, Triode형 CNT 램프 구동을 위해서는 캐소드(cathode)와 게이트(gate) 사이에서 양방향(Bi-polar) 저전압 펄스가 필요하고 애노드(anode)에 직류 고전압이 필요하여 이를 위한 저전압 펄스 및 직류 고전압 전원장치에 대한 개발을 연구하였다.

  • PDF