• Title/Summary/Keyword: Bi-layer

Search Result 510, Processing Time 0.033 seconds

MICROSCOPIC OBSERVATIONS OF FAT TRANSLOCATION IN THE TISSUE OF YELLOW CORVENIA DURING SALTING AND DRYING ("굴비" 제조과정중의 지방의 이동에 대한 조직학적 관찰)

  • PYEUN Jae-Hyeung;LEE Eung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.1 no.2
    • /
    • pp.63-71
    • /
    • 1968
  • Salted and dried yellow corvenia(Pseudosciaena manchurica), so called 'Gul-bi', is one of nation-widely consuming fish foo::ls. It is suitable for a long term preservation and its pro-duce is also a great deal on sea food processing in this country. The texture of 'Gul-bi', however, have often appeared to be a delicate factor for the quality of the product. The loss or dislocation of fat in the tissue of the fish resulted by salting and drying is believed to profoundly relate to the texture of product. In this paper, the tissue of yellow corvenia and movement of fat were microscopically observed before salting, immediately after salting, and after drying and the results observed in the tissues dry salted, brine salted, and brine salted with the addition of BHA were compared. The cross section of yellow corvenia muscle showed that a distinctive border by connective tissue between white and red muscle could not be seen in general, and red muscle was surrounded by hypodermic fatty tissues. In the tissue of fresh yellow corvenia, the fat was mainly distributed in hypodermic fat layer which located under the corium while rarely distributed in white muscle. It was found that some parts of the fat in the tissue were permeated into intermuscular tissue passing through the connective tissues during salting. The result Was the same in both dry-salting and brine-salting tissue. However, the fat translocated into intermuscular tissues disappeared during drying process in the salted without BHA tissues whereas in BHA added tissue. This result suggested that BHA may take a role of multiple effect in translocation of fat in tissues as well as in retarding oxidation. In an advanced stage of salted and dehydration, the muscle fibers were ajoined together and then limits between muscle fibers already became indistinguishable. And the migrated fat into intermuscular tissue aggregated around the connective tissue and are apt to gradually to flow out from the muscular system through these tissues.

  • PDF

Glass Antenna Using Transparent IZTO/Ag/IZTO Multilayer Electrode (IZTO/Ag/IZTO 다층 투명전극을 이용한 안경용 웨어러블 안테나)

  • Hong, Seungman;Kim, Youngsung;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.372-377
    • /
    • 2016
  • Communication flow is changing rapidly. Recently, a range of wearable devices such as wearable glasses and wearable watch, have been launched. These kinds of wearable devices help people to live a more comfortable life. Wearable devices most have an antenna for wireless communication. This paper reports a transparent antenna that is made of an optically transparent material for wearable glasses. Transparent antenna can be applied to smart windows and will not disturb the view of user. IZTO/Ag/IZTO multilayer electrode has higher electrical and optical properties. This antenna is available because of its good electrical properties. This study measured the performance of the proposed transparent antenna, which is made of a multilayer electrode, applied to a lens. The proposed antenna was simulated with several substrates. The antenna impedance was matched with length and width of the antenna. The antenna's conductivity and transparency was measured using a HMS-3000 and UV-spectrometer. A 40nm thick Ag single layer antenna was fabricated on a flexible polyimide substrate for comparing the antenna performances. The fabricated antenna is useable at a frequency of 2.4-2.5GHz, which is suitable for Wifi communications and has peak gain of 2.89dBi and an efficiency of 34%.

Design of Compact and Broadband Quasi-Yagi Antenna Using Balance Analysis of the Balun (발룬의 평형도 해석을 이용한 소형화된 광대역 Quasi-Yagi 안테나 설계)

  • Woo, Dong Sik;Kim, In-Bok;Kim, Young-Gon;Kim, Kang Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2013
  • In this paper, a compact, broadband quasi-Yagi antenna utilizing balance analysis of the ultra-wideband microstrip-to-coplanar stripline(MS-to-CPS) balun is proposed. The antenna size was reduced by removing the reflector on bottom layer and ground plane is used as a reflector. A planar balun that transforms from microstrip(MS) to balanced coplanar stripline(CPS) is characterized in the amplitude and phase imbalances at CPS output ports are investigated and discussed. As compared with the conventional balun, the proposed MS-to-CPS balun demonstrated very wideband performance from 7 to over 20 GHz. From the simulation study, amplitude and phase imbalances are within 1 dB and ${\pm}5^{\circ}$, respectively. The implemented antenna provides very wide bandwidth from 6.9 to 15.1 GHz(74.5 %). The gain of the antenna is from 3.7 to 5.5 dBi, the front-to-back ratio is more than 10 dB, and the nominal radiation efficiency is about 94 %.

Study(IV) on the Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - Field Verification of Long-term Allowable Compressive Load of PHC Piles by Analyzing Pile Load Test Results - (사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(IV) - 압축정재하시험 및 양방향재하시험 자료 분석을 통한 매입 PHC말뚝의 장기허용압축하중의 실증 성능 검증 -)

  • Lee, Wonje;Kim, Chae Min;Yun, Do Kyun;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.9
    • /
    • pp.29-36
    • /
    • 2019
  • Axial compressive failure loads ($P_n$) of diameter 500 mm and diameter 600 mm A type PHC pile were calculated as 7.7 MN and 10.6 MN, respectively. In the static pile load tests, the maximum axial compressive loads of the above 2 kinds of A type pile were measured as 6.9 MN and 8.8 MN respectively, therefore these measured maximum loads were at the level of 90% and 83% of $P_n$ respectively. Long-term allowable axial compressive loads ($P_a$) of the above 2 kinds of A type pile were 1.7 MN and 2.3 MN respectively. From the bi-directional pile load test data on the prebored PHC piles, it was confirmed that the allowable axial compressive bearing resistance was estimated as 131% of the long-term allowable compressive load of the PHC pile and showed higher than the allowable bearing capacity calculated by the current design method. Therefore, it has been verified that the PHC pile can be used up to the maximum long-term allowable compressive load, and it is suggested that the ultimate pile capacity formula used in the current design for prebored PHC piles should be improved to accommodate the actual capacity.

Biomass and distribution of Antarctic Krill, Euphausia superba, in the Northern part of the South Shetland Islands, Antarctic Ocean (남극 남쉐틀란드 군도 북부 해역의 크릴 분포 및 자원량)

  • KANG Donhyug;HWANG Doojin;KIM Suam
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.6
    • /
    • pp.737-747
    • /
    • 1999
  • To estimate biomass and distribution of the Antarctic krill (Euphausia superba), hydroacoustic survey was conducted on board of R/V Yuzhmorgeologiya, which was chartered by Korea Antarctic Research Program (KARP) group from 18 to 21 December 1998, in the northern part of the South Shetland Islands, Antarctic Ocean, The scientific echo sounder (towing body type) used was EK- 500 (SIMRAD, Norway) with echo integrator (BI-500) at 38 kHz frequency and recorded mean backscattering cross-section coefficient (SA) per 1 $mile^2$ of sea surface. Also, Bongo net sampling was carried out to determine the size of krill and CTD (Conductivity, Temperature and Depth) casting to understand physical structure. Water column was divided into 5 layers (22$\~$65 m, 65$\~$115 m, l15$\~$65 m, 165$\~$215 m and 215$\~$315 m) to know vertical distribution of krill biomass. The standard length of krill collected was between 30 mm and 51 mm, and adult krill had single mode (41 mm). Maximum horizontal length of krill patch was about 35 nautical mile and vertical thickness was about 275 m. High density of krill was appeared in frontal area between Circumpolar Deep Water (>$1^{\circ}C$) and very low temperature water mass (< $-0.5^{\circ}C$) that originate from Weddell Sea. According to the results calculated using target strength equation, krill density was totally higher in continental slope and open water areas than in coastal area. In the study area, krill seems to distribute in depth; density was low at first layer ($\={\rho}=17.0\;g/m^2$) and higher at fourth layer ($\={\rho}=40.19\;g/m^2$). The estimated krill biomass at total survey area and water column was about 2.77 million metric ion ($\={\rho}=151.0\;g/m^2$) and coefficient of valiance ( CV, $\%$) was 19.92. The proportions and biomass of krill biomass at each layer were as follows; layer 1 ($11.3\%$, 0.31 million metric ton, CV=16.24), layer 2 ($13.3\%$, 0.37 million metric ton, CV=34.91), layer 3 ($23.7\%$, 0.66 million metric ton, CV=41.5), layer 4 ($26.6\%$, 0.74 million metric ton, CV=27.84) and layer 5 ($25\%$, 0.69 million metric ton, CV= 26.83).

  • PDF

Effect of Glass Frit in $TiO_2$ Electrode for DSSCs (Glass Frit을 이용한 염료감응 태양전지의 광 특성 연구)

  • Kim, Jongwoo;Jeon, Jaeseung;Kim, Dongsun;Hwang, Seongjin;Kim, Hyungsun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.75.1-75.1
    • /
    • 2010
  • Dye sensitized solar cells(DSSCs) have been extensively studied due to their various advantages such as low production cost, colorful design, and eco-friendly process. Long optical path length is one of the most effective method to improve light harvest efficiency for DSSCs. Multi-layered $TiO_2$ nano-structured film with scattering layer has been studied to generate scattering effect by many researchers. It was expected that the difference of refractive index between $TiO_2$ particles and glass frit would generate the light scattering effect and provide the long optical path length. Therefore, to enhance the scattering effect, the frits of $Bi_2O_3-B_2O_3$-ZnO glass system that has the different refractive index were added to $TiO_2$ pastes in this study. First of all, the absorbance and haze factor of $TiO_2$ electrode with dyes and the refractive index of glass frit and $TiO_2$ were measured, respectively. To study the effect of frits, the efficiencies of DSSCs added glass frit and without glass frit were compared. Our results showed slightly higher efficiency with the different absorbance and haze factor of $TiO_2$ and glass frit. It was considered that the light scattering effect would be improved with adding frits to $TiO_2$ paste. Our preliminary studies will be useful for increasing efficiency of DSSCs.

  • PDF

Behavior of Vibration Fracture for Sn-Ag-Cu-X Solders by Soldering (Sn-Ag-Cu-X 무연솔더로 솔더링 된 접합부의 진동파괴 거동)

  • Jin, Sang-Hun;Kang, Nam-Hyun;Cho, Kyung-Mox;Lee, Chang-Woo;Hong, Won-Sik
    • Journal of Welding and Joining
    • /
    • v.30 no.2
    • /
    • pp.65-69
    • /
    • 2012
  • Environmental and health concerns over the lead have led to investigation of the alternative Pb-free solders to replace commonly used Pb-Sn solders in microelectronic packaging application. The leading candidates for lead-free solder alloys are presently the near eutectic Sn-Ag-Cu alloys. Therefore, extensive studies on reliability related with the composition have been reported. However, the insufficient drop property of the near eutectic Sn-Ag-Cu alloys has demanded solder compositions of low Ag content. In addition, the solder interconnections in automobile applications like a smart box require significantly improved vibration resistance. Therefore, this study investigated the effect of alloying elements (Ag, Bi, In) on the vibration fatigue strength. The vibration fatigue was conducted in 10~1000Hz frequency and 20Grms. The interface of the as-soldered cross section close to the Cu pad indicated the intermetallic compound ($Cu_6Sn_5$) regardless of solder composition. The type and thickness of IMC was not significantly changed after the vibration test. It indicates that no thermal activities occurred significantly during vibration. Furthermore, as a function of alloying composition, the vibration crack path was investigated with a focus on the IMCs. Vibration crack was initiated from the fillet surface of the heel for QFP parts and from the plating layer of chip parts. Regardless of the solder composition, the crack during a vibration test was propagated as same as that during a thermal fatigue test.

Influence of Film Thickness on the Structural, Electrical and Optical Properties of the GZO/ZnO Films (GZO/ZnO 적층박막의 두께변화에 따른 구조적, 전기적, 광학적 물성 변화)

  • Kim, Seung-Hong;Kim, Sun-Kyung;Kim, So-Young;Jeon, Jae-Hyun;Gong, Tae-Kyung;Choi, Dong-Hyuk;Son, Dong-Il;Kim, Daeil
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.27 no.1
    • /
    • pp.23-26
    • /
    • 2014
  • Ga doped ZnO (GZO) single layer and GZO/ZnO bi-layered films were deposited on glass substrates by radio frequency magnetron sputtering and then the influence of film thickness on the structural, electrical, and optical properties of the films was considered. Thicknesses of the GZO/ZnO films was varied as GZO 100 nm, GZO 85 nm/ZnO 15 nm and GZO 70 nm/ZnO 30 nm, respectively. The observed result means that optical transmittance and electrical resistivity of the films were influenced with film thickness and GZO 85 nm/ZnO 15 nm bilayered films show the higher figure of merit than that of the films prepared other films in this study.

Ferroelectric properties of BLT films deposited on $ZrO_2$Si substrates

  • Park, Jun-Seo;Lee, Gwang-Geun;Park, Kwang-Hun;Jeon, Ho-Seung;Im, Jong-Hyun;Park, Byung-Eun;Kim, Chul-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.172-173
    • /
    • 2006
  • Metal-ferroelectric-insulator-semiconductor (MFIS) structures with $Bi_{3.35}La_{0.75}Ti_3O_{12}$ (BLT) ferroelectric film and Zirconium oxide ($ZrO_2$) layer were fabricated on p-type Si(100). $ZrO_2$ and BLT films were prepared by sol-gel technique. Surface morphologies of $ZrO_2$ and BLT film were measured by atomic force microscope (AFM). The electrical characteristics of Au/$ZrO_2$/Si and Au/BLT/$ZrO_2$/Si film were investigated by C-V and I-V measurements. No hysteretic characteristics was observed in the C-V curve of the Au/$ZrO_2$/Si structure. The memory window width m C-V curve of the Au/BLT/$ZrO_2$/Si diode was about 1.3 V for a voltage sweep of ${\pm}5$ V. The leakage current of Au/$ZrO_2$/Si and Au/BLT/$ZrO_2$/Si structures were about $3{\times}10^{-8}$ A at 30 MV/cm and $3{\times}10^{-8}$ A at 3 MV/cm, respectively.

  • PDF

Highly Reliable Solder ACFs FOB (Flex-on-Board) Interconnection Using Ultrasonic Bonding

  • Kim, Yoo-Sun;Zhang, Shuye;Paik, Kyung-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2015
  • In this study, in order to improve the reliability of ACF interconnections, solder ACF joints were investigated interms of solder joint morphology and solder wetting areas, and evaluated the electrical properties of Flex-on-Board (FOB) interconncections. Solder ACF joints with the ultrasonic bonding method showed excellent solder wetting by broken solder oxide layers on solder surfaces compared with solder joints with remaining solder oxide layer bonded by the conventional thermo-compression (TC) bonding method. When higher target temperature was used, Sn58Bi solder joints showed concave shape due to lower degree of cure of resin at solder MP by higher heating rate. ACFs with epoxy resins and SAC305 solders showed lower degree of resin cure at solder MP due to the slow curing rate resulting in concave shaped solder joints. In terms of solder wetting area, solder ACFs with $25-32{\mu}m$ diameters and 30-40 wt% showed highest wetted solder areas. Solder ACF joints with the concave shape and the highest wetting area showed lower contact resistances and higher reliability in PCT results than conventional ACF joints. These results indicate that solder morphologies and wetting areas of solder ACF joints can be controlled by adjustment of bonding conditions and material properties of solder and polymer resin to improve reliability of ACF joints.