• Title/Summary/Keyword: Bi-directional Flow

Search Result 88, Processing Time 0.021 seconds

FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube (평균 양방향 튜브의 설계 최적화를 위한 FLUENT 코드해석)

  • Kang, Kyong-Ho;Yun, Byong-Jo;Euh, Dong-Jin;Baek, Won-Pil
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.14-19
    • /
    • 2005
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the average bi-directional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the average bi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

Korean Machine Comprehension using Dual Bi-Directional Attention Flow (Dual Bi-Directional Attention Flow를 이용한 한국어 기계이해 시스템)

  • Lee, Hyeon-gu;Kim, Harksoo;Choi, Jungkyu;Kim, Yi-reun
    • Annual Conference on Human and Language Technology
    • /
    • 2017.10a
    • /
    • pp.41-44
    • /
    • 2017
  • 기계이해 시스템은 주어진 문서를 이해하고 질의에 해당하는 정답을 출력하는 방법으로 심층 신경망을 활용한 주의집중 방법이 발달하면서 활발히 연구되기 시작했다. 본 논문에서는 어휘 정보를 통해 문서와 질의를 이해하는 어휘 이해 모델과 품사 등장 정보, 의존 구문 정보를 통해 문법적 이해를 하는 구문 이해 모델을 함께 사용하여 기계이해 질의응답을 하는 Dual Bi-Directional Attention Flow모델을 제안한다. 한국어로 구성된 18,863개 데이터에서 제안 모델은 어휘 이해 모델만 사용하는 Bi-Directional Attention Flow모델보다 높은 성능(Exact Match: 0.3529, F1-score: 0.6718)을 보였다.

  • PDF

Korean Machine Comprehension using Dual Bi-Directional Attention Flow (Dual Bi-Directional Attention Flow를 이용한 한국어 기계이해 시스템)

  • Lee, Hyeon-gu;Kim, Harksoo;Choi, Jungkyu;Kim, Yi-reun
    • 한국어정보학회:학술대회논문집
    • /
    • 2017.10a
    • /
    • pp.41-44
    • /
    • 2017
  • 기계이해 시스템은 주어진 문서를 이해하고 질의에 해당하는 정답을 출력하는 방법으로 심층 신경망을 활용한 주의집중 방법이 발달하면서 활발히 연구되기 시작했다. 본 논문에서는 어휘 정보를 통해 문서와 질의를 이해하는 어휘 이해 모델과 품사 등장 정보, 의존 구문 정보를 통해 문법적 이해를 하는 구문 이해 모델을 함께 사용하여 기계이해 질의응답을 하는 Dual Bi-Directional Attention Flow모델을 제안한다. 한국어로 구성된 18,863개 데이터에서 제안 모델은 어휘 이해 모델만 사용하는 Bi-Directional Attention Flow모델보다 높은 성능(Exact Match: 0.3529, F1-score: 0.6718)을 보였다.

  • PDF

A New Algorithm to Reduce the Mal-Operation of DOCR in Bi-directional Power Distribution Systems

  • Jang, Su-Hyeong;Oh, Joon-Seok;Jeong, Ui-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.585-591
    • /
    • 2016
  • DOCR can be used to efficiently increase the reliability and to protect the bi-directional D/L(Distribution Lines). As more DG(Distributed Generation)s attempt to connect the bi-directional D/L, there is an increasing need for studies of how to use DOCR installed in the D/L. This paper investigates the operating principles of DOCR and presents the results an effect of sequence and fault impedance in L-L(Line to Line) fault. An advanced DOCR operating algorithm is proposed to reduce the mal-operation of conventional DOCR. The proposed algorithm is applied to the bi-directional power flow system and shows that it decreases the mal-operation of DOCR through the computer simulation.

FLUENT Code Analyses for Design Optimization of an Average Bi-directional Flow Tube (평균 양방향 튜브의 설계 최적화를 위한 FLUENT코드해석)

  • Kang, Kyong-Ho;Yun, Byong-Jin;Euh, Dong-Jin;Baek, Won-Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.180-186
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. 3-dimensional steady state flow analyses using FLUENT 5.4 code were performed to validate the application of the averagebi-directional flow tube in case of water and air flow In this study, sensitivity studies have been performed to optimize the design features of the average hi-directional flow tube which can be applied for the various experimental conditions. For Re numbers above 1000, the k values are nearly constant regardless of the Re numbers and flow types and calculation results and experimental data coincides quite well. The current FLUENT calculation results suggest that linearity of the k values in various design features of the average BDFT is highly promising, which means that it is quite reasonable to select the typical design of the average BDFT for the convenience of the experimental conditions.

  • PDF

Flow Analyses using FLUENT 5.4 Code for the Bi-directional Flow Tube (FLUENT 5.4 코드를 이용한 양방향 유동 튜브에 대한 유동해석)

  • Kang, Kyoung-Ho;Yun, Byung-Jo;Baek, Won-Pil
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.934-938
    • /
    • 2003
  • Flow analyses using FLUENT 5.4 code were performed to validate the application of the local bidirectional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the bi-directional flow tube which can be applied for the various experimental conditions. 2-dimensional axisymmetric steady state flow analyses have been performed. By calculating the differential pressure at both the front and the rear hole of the flow tube, K values were evaluated. The K values show good linearity regardless of the tube sizes and the Re numbers in both water and air flow. And system pressure and water subcooling didn’'t affect the K values. Under the elevated pressure of 80bar with 80K water subcooling, the K value indicates a similar trend with the case of 2bar with 80K water subcooling.

  • PDF

Development of Bi-directional Triple-eccentric Type Butterfly Valve (양방향 삼중편심 버터플라이 밸브 개발)

  • Kim, Soo-Young;Lee, Dong-Myung;Bae, Jung-Hoon;Shin, Sung-Chul;Sul, Chang-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.5
    • /
    • pp.545-551
    • /
    • 2009
  • In naval architecture and offshore engineering, the development and a broad use has been achieved in the field of flow control valves for pipe system. Butterfly valves are also widely used for flow control, but there are not many studies for triple-eccentric butterfly valves. Moreover, if the fluid of pipeline flows in the bi-direction then it makes more complicate to adapt triple-eccentric butterfly valves to flow control. In this study, we are trying to develop a bi-directional triple-eccentric butterfly valve through sealing mechanism and stem design study. Digital mockup using 3D CAD was constructed for shape interference check and structural analysis was conducted for structural safety. Also we performed leakage test to check out the durability of the bi-directional pressure for the developed valve.

A Study on Design of Notches in Valve Plate of Swash Plate Type Axial Piston Pumps Operated Bi-directionally (양방향 구동 사판식 액시얼 피스톤 펌프의 밸브 플레이트 노치 설계에 관한 연구)

  • Choi, Sae Ryung;Lee, Ill Yeong;Han, Sung Min;Shin, Jung Woo
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.39-46
    • /
    • 2016
  • Flow and pressure ripple in swash plate type piston pumps is largely dependent on the design of notches(silencing grooves) in the valve plate. In uni-directional pumps, the basic design concept for notches in the valve plate could be said to be established. It is easily deduced that the design concept for notches in uni-directional pumps can not be simply applied to bi-directional pumps requested for EHA(electric hydrostatic actuators). To carry out systematic research on technological issues regarding notch applications to bi-directional piston pumps, five notch designs are devised. The effects of the notch designs on the characteristics of the pump are investigated by numerical simulations and experiments. Through this study, basic concepts about notch design for bi-directional piston pumps are suggested.

Bi-directional Buck-Boost DC-DC Converter for Bus Voltage Regulation (Bus 전압 레귤레이션을 위한 쌍방향 Buck-Boost DC-DC컨버터)

  • Ko, Tae-Ill;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.348-350
    • /
    • 1994
  • In this paper, bi-directional buck-boost DC-DC converter for bus regulation system is presented. This converter which has one buck and one boost topology achieves bi-directional power flow using a common power inductor and alternative power switches. By connecting the battery to bus line, it can be regulated to bus voltage and charged the battery alternatively. And as an application, a mode controller is adopted to the converter.

  • PDF

Development of an Average Bi-directional Flow Tube for the Measurement of Single and Two phase Flow Rate (단상 및 이상유동 유량 계측을 위한 평균 양방향 유동 튜브 개발)

  • Yun, Byong-Jo;Kang, Kyong-Ho;Euh, Dong-Jin;Baek, Won-Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.172-179
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. The suggested instrumentation was tested in the air-water vertical test section which has 80mm inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. From the test, single air and water flow rate was measured successfully. For the emasurement of two phase flow rate, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within $10\%$ error of measured data.

  • PDF