• 제목/요약/키워드: Bi-2223 tapes

검색결과 195건 처리시간 0.023초

고온초전도 테이프를 이용한 다단 전류 도입선의 최적설계 (Optimal Design of Multi-Step Current Leads Using HTS Tapes)

  • 김민수;나필선;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.84-88
    • /
    • 2001
  • The optimum cross-sectional area Profile of gas-cooled high-temperature superconductor (HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant safety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-step HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-step current leads are discussed.

  • PDF

고온초전도변압기의 특성시험 (Test of an High Temperature Superconducting Power Transformer)

  • 이희준;차귀수;이지광;김우석;한송엽;류경우;최경달
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권9호
    • /
    • pp.572-577
    • /
    • 2000
  • This paper describes the test results of a single phase 3kVA high temperature superconducting power transformer. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used. Among them two double pancake windings are connected in series for high voltage winding and the others are connected in parallel for low voltage winding. The rated voltage and current of primary winding and secondary winding are 220/110V. 13.7/27.3A. Fundamental characteristics are obtained through short circuit and no load test. The over load capability and characteristics are investigated.

  • PDF

SMES용 고온초전도 전류도입선의 전자계 해석 및 형상설계 (The Electromagnetic Field Analysis and the Design of HTS Current Lead for SMES)

  • 장현만;오상수;조영식;조전욱;하홍수;하동우;권영길;성기철;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.136-138
    • /
    • 2000
  • 1.5kA HTS current leads for a superconducting magnetic energy storage(SMES) magnet, which are connected to a conventional vapor cooled copper leads, were designed. The HTS lead composed of cylindrically arranged Bi-2223/Ag-1 at5Au tapes and a stainless steel tube. The minimum operating current of the lead is 1.71 kA at 77.3K, self magnetic field, and the heat input to the liquid helium from the clod end of the 36 cm lead is 0.5 W/lead.

  • PDF

고화질소 냉각형 고온초전도마그네트 개발(I) (Development of HTS magnet cooled by solid nitrogen(I))

  • 오상수;하홍수;하동우;권영길;류강식;이해근;;한일용
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.19-21
    • /
    • 2000
  • We are developing portable type HTS magnet system cooled by solid nitrogen. This system have recooling and recharging capabilities. In this paper, we report preliminary test results obtained from the experimental solid nitrogen system and pancake magnet would with Bi-2223/Ag tapes, respectively. The operation period was sensitively dependent on the vacuum rate n the cryostat, size of SUS tube for flowing N_{2}$, and liquid nitrogen to cool the cryostat. The fabricated coil I_{c}$was 75 A at 20 K in self field.

  • PDF

고온초전도변압기 특성시험 (Test of a High Temperature Superconducting Power Transformer)

  • 이희준;차귀수;김우석;한송엽;류경우;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.33-35
    • /
    • 1999
  • This paper describes the test results of the single phase 3kVA high temperature superconducting power trans-former. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used in total. Among them two double pancake windings are connected in series for high voltage winding and two double pancake windings are connected in parallel for low voltage winding. The rated voltages of each winding are 220/110 V. Fundamental characteristics are obtained through short circuit and no load tests. The over load capability and characteristics are investigated.

  • PDF

고온 초전도 선재의 곡률반경에 따른 특성변화 연구 (The study of characteristic change versus a curvature radius of high Tc superconducting wire)

  • 강형곤;김민기;최명호;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.34-37
    • /
    • 1994
  • .In this study, we measured Ic depending on a curvature radios of High Tc superconducting tapes which were made of a single wire, two and three WIT(wire in tube). Wires are manufactured by the process of press ins and sintering (150h, at 845$^{\circ}C$ ) for the growth of 2223 high Tc Bi superconducting phase. We know that Ic of a single wire decrease with reduction of a curvature radius. The maximum Ic of 2 WIT wire is 2.54 (A) and have a better characteristic than a single wire (0.89 A) at a curvature radius 75mm.

  • PDF

High Temperature Superconducting tape(Bi-2223)의 접속시 통전특성 (Characteristics of Joint High Temperature Superconducting tape)

  • 김해준;심기덕;조전욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.244-245
    • /
    • 2007
  • Specially, High Temperature Superconducting power-transmission cable(HTS cable), 3-phase 100m long, 22.9kV class HTS power transmission cable system have been developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. that is one of 21st century frontier project in Korea. This cable was installed in KEPCO(Go-chang) testing site. In case of manufacturing HTS cable, superconducting joint is very important because they need very long tapes. Therefore, this paper gives some investigation of AC Loss in joined HTS tape by using several joint methods. Finally, this paper was shown background data for the form of HTS cable joint.

  • PDF

Bi-2223 고온 초전도 선재의 교류손실에 관한 연구 (The a.c. losses in (Bi,Pb)2Sr2Ca2Cu3Ox silver-sheathed superconducting tapes)

  • 강형구;추용;이찬주;고태국;나완수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.822-824
    • /
    • 2000
  • To apply HTS to AC devices, it is necessary that study theoretically and experimentally to analyze the AC losses. It should be investigated the theoretical mechanisms precede the actual experiments. Because the AC losses cause some complicated troubles in AC machines, we can design the machines properly. In this study, firstly we analyze the basic cause of AC losses by investigating the several loss factors, secondly measure the AC losses of HTS by using Magnetization. Technique and this results show that AC losses of HTS is tenuous than those of general materials used in power system. Consequently we can compare the actual results with the theoretical results. And we find that AC losses of HTS are related to the amplitude of external magnetic field and the frequency. Through this study, we find that it is possible to apply the results by Magnetization. Technique to the AC power system, to the design of AC machine, to design of HTS proper to the foretold AC losses.

  • PDF

Preliminary investigation of Ic homogeneity along the longitudinal direction of YBCO coated conductor tape under tensile loading

  • Dizon, J.R.C.;Oh, S.S.;Sim, K.D.;Shin, H.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.24-28
    • /
    • 2013
  • In this study, the homogeneity of critical current, $I_c$, along the lengthwise direction in the coated conductor (CC) tape under uniaxial tension was investigated using a multiple voltage tap configuration. Initially, a gradual and homogeneous $I_c$ degradation occurred in all subsections of the tape up to a certain strain value. This was followed by an abrupt $I_c$ degradation in some subsections, which caused scattering in $I_c$ values along the length with increasing tension strain. The $I_c$ degradation behaviour was also explained through n-value as well as microstructure analyses. Subsections showed $I_c$ scattering corresponding to damaged areas of the CC tape revealed that transverse cracks were distributed throughout the gauge length. This homogeneous $I_c$ degradation behaviour under tension is similar with the case under torsion strain but different with the case under hard bending which were previously reported. This behaviour is also different with the case using Bi-2223 HTS tapes under tension strain.